Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Investigation
Open Access

Phase III Study of 18F-PSMA-1007 Versus 18F-Fluorocholine PET/CT for Localization of Prostate Cancer Biochemical Recurrence: A Prospective, Randomized, Crossover Multicenter Study

Pierre Olivier, Anne-Laure Giraudet, Andrea Skanjeti, Charles Merlin, Pierre Weinmann, Ines Rudolph, Alexander Hoepping and Mathieu Gauthé
Journal of Nuclear Medicine April 2023, 64 (4) 579-585; DOI: https://doi.org/10.2967/jnumed.122.264743
Pierre Olivier
1Nuclear Medicine and Nancyclotep Molecular Imaging Platform, CHRU-Nancy, Université de Lorraine, Nancy, France;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Anne-Laure Giraudet
2Nuclear Medicine, LUMEN, Centre Leon Berard, Lyon, France;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Andrea Skanjeti
3Nuclear Medicine, HCL, Claude Bernard University-Lyon-1, Lyon, France;
4Nuclear Medicine, Centre Hospitalier Sud Francilien, Corbeil Essonne, France;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Charles Merlin
5Department of Nuclear Medicine, Centre Jean Perrin, Clermont-Ferrand, France;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pierre Weinmann
6HEGP-AP-HP, Nuclear Medicine, Université de Paris, Paris, France;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ines Rudolph
7ABX Advanced Biochemical Compounds, Radeberg, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Alexander Hoepping
7ABX Advanced Biochemical Compounds, Radeberg, Germany; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mathieu Gauthé
8Hôpital Tenon-AP-HP, Sorbonne Université, Paris, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

The objective of this study was to compare 18F-PSMA-1007 PET/CT and 18F-fluorocholine PET/CT for the localization of prostate cancer (PCa) biochemical recurrence. Methods: This prospective, open-label, randomized, crossover multicenter study included PCa patients with prior definitive therapy and suspected PCa recurrence. All men underwent both 18F-PSMA-1007 PET/CT and 18F-fluorocholine PET/CT (102 received 18F-PSMA-1007 PET/CT first and 88 received 18F-fluorocholine PET/CT first). All images were assessed independently by 3 readers masked to all clinical information using a 3-point qualitative scale (0 = no recurrence, 1 = undetermined, and 2 = recurrence). Patients were monitored for approximately 6 mo. An independent panel with a urologist, radiologist, and nuclear physician reviewed all clinical data, including imaging and response to therapy, but were masked regarding PET/CT information; acting in consensus, they determined a patient-based and region-based composite standard of truth for PCa lesions. The “correct detection rates” for PCa lesions on a patient basis for each radiopharmaceutical were compared for the 3 readers individually and for the “average reader.” Secondary objectives included determining whether PET/CT findings affected diagnostic thinking (impact of a test result on posttest vs. pretest probability of a correct diagnosis), therapeutic decision making (description and quantification of impact of diagnostic information gained with both radiopharmaceuticals on patient management), and adequacy of management changes. Results: A total of 190 patients were included. The primary endpoint was met. The overall correct detection rates were 0.82 for 18F-PSMA-1007 and 0.65 for 18F-fluorocholine (P < 0.0001) when undetermined findings were considered positive for malignancy and 0.77 and 0.57, respectively (P < 0.0001), when undetermined findings were considered negative for malignancy. A change in diagnostic thinking due to PET/CT was reported in 149 patients; 18F-PSMA-1007 contributed more than 18F-fluorocholine in 93 of these patients. In 122 patients, PET/CT led to an adequate diagnosis that benefited the patient; 18F-PSMA-1007 contributed more than 18F-fluorocholine in 88 of these patients. Conclusion: 18F-PSMA-1007 PET/CT is superior to 18F-fluorocholine PET/CT for the localization of PCa recurrence. Decision making was more beneficial when based on 18F-PSMA-1007 PET/CT results.

  • PET/CT
  • prostatic neoplasms
  • prostate-specific antigen
  • decision making

Prostate cancer (PCa) is the most prevalent cancer in men, with approximately 473,000 new diagnoses and more than 108,000 deaths in Europe in 2020 (1). Although long-term outcomes are good for most men, recurrence after definitive therapy is common. One study found that 37% of patients with radical prostatectomy and 48% of patients with radiation therapy had biochemical recurrence within 15 y of the initial definitive treatment; for both, most relapses occurred within the first 5 y (2). The diagnosis of PCa recurrence after prior definitive therapy is based on an increase in serum prostate-specific antigen (PSA); the threshold level varies by treatment, being higher for patients treated with radiation than for those treated by radical prostatectomy (3). PET/CT imaging is the recommended modality for the localization of PCa recurrence (3). 18F-fluorocholine has been recommended for PET/CT imaging of PCa recurrence since a marketing authorization was granted in France in 2010. The development of radiopharmaceuticals that directly target the extracellular domain of the prostate-specific membrane antigen (PSMA) resulted in an improvement in the detection of PCa lesions, and this approach is now recommended for PET/CT imaging of PCa recurrence.

A recent metaanalysis evaluated the diagnostic efficacy of all PSMA-directed PET agents and reported an overall detection rate of 74.1% with no notable differences among the various tracers (4). The authors concluded that PSMA-directed PET agents were preferable to choline PET, particularly in patients with a serum PSA level of less than 1 ng/mL (4). However, to date, only single-center studies with a limited number of patients have compared 18F-fluorocholine with a radiolabeled PSMA ligand for PET/CT imaging of PCa recurrence localization, and large randomized controlled trials are lacking (5).

18F-PSMA-1007 was developed by Cardinale et al. (6) and Giesel et al. (7) in Heidelberg in 2016 as a PSMA-targeting ligand with low urinary excretion. The compound showed a high detection rate at low PSA values and high sensitivity and specificity in both biochemical recurrence and primary staging (8,9). In some patients, nonspecific bone uptake may be a confounding factor (10).

The ABX-CT-301 study (NCT04102553) aimed to compare 18F-PSMA-1007 PET/CT and 18F-fluorocholine PET/CT for the detection of PCa lesions in patients with biochemical recurrence. Secondary objectives were to compare the detection rates of the clinical investigators for both radiopharmaceuticals in a patient-based analysis; to assess the diagnostic performance of both radiotracers for PCa lesions in a region-based analysis; to assess the impact on diagnostic thinking, therapeutic decision making, and adequacy of therapy changes for both radiotracers; and to assess the safety profile of 18F-PSMA-1007.

MATERIALS AND METHODS

Population

This study was a prospective, open-label, randomized, 2-armed crossover study conducted in 6 study centers in France. Men who were at least 18 y old, who were diagnosed with PCa, and who had prior definitive therapy were considered for enrollment. Eligible patients presented with suspected PCa recurrence, defined as 3 consecutive PSA increases or a PSA rise of greater than or equal to 2.0 ng/mL above the nadir after radiotherapy (external-beam radiation therapy or brachytherapy) or cryotherapy or a PSA rise of greater than or equal to 0.2 ng/mL after prostatectomy. The main exclusion criteria were participation in another therapeutic clinical trial within 5 d of enrollment in the present study and a life expectancy of less than 6 mo.

The study protocol was approved by a national ethics committee certified by the French Ministry of Health (Institutional Review Board: IORG0009855). All patients gave written informed consent before randomization.

Intervention

All men underwent both 18F-PSMA-1007 PET/CT and 18F-fluorocholine PET/CT using a standardized imaging protocol (supplemental materials, available at http://jnm.snmjournals.org). Patients were randomized using a computer-generated block-randomized sequence, stratified by center, to receive either 18F-PSMA-1007 PET/CT or 18F-fluorocholine PET/CT first. Patients underwent both PET/CT examinations within a minimum of 24 h and a maximum of 240 h; depending on the individual site preferences, either low-dose or diagnostic CT could be used, but the use of contrast agents was not permitted. At each PET/CT visit, vital signs were recorded before and after injection of the study drug and again at the end of the PET/CT examination. Samples for laboratory tests, including serum PSA levels, were obtained before the administration of each study drug. Patients were monitored for adverse events for 24 h after the second PET/CT examination (supplemental materials). Then we collected all data related to the treatments, additional diagnostic methods (including biopsy confirmation of detected foci, if feasible) and PSA values obtained in the 6 months during which the patients were followed.

Image Reading and Standard of Truth

PET images were read on-site on the day of acquisition by investigators who were not masked regarding clinical data and were transferred to a core imaging laboratory where they were evaluated by 3 independent masked readers (supplemental materials). 18F-PSMA-1007 and 18F-fluorocholine images were read on separate days, at least 1 wk apart. The results of an “average reader” were determined statistically from the 3 independent reader results and not by a consensus read.

The composite standard of truth (recurrence, no recurrence, or undetermined) at the time of imaging was determined by an independent expert panel that considered all available clinical patient data from before inclusion to the end of the follow-up period, excluding all information from PET/CT (supplemental materials). The expert panel consisted of a urologist, a radiologist, and a nuclear physician; they reached their conclusions by consensus.

Outcomes

The primary objective was to compare 18F-PSMA-1007 with 18F-fluorocholine with regard to the “correct detection rate” for recurrent PCa lesions on a patient basis, as determined by 3 independent readers and confirmed by an independent expert panel on the basis of a composite standard of truth (supplemental materials).

Secondary objectives were to compare the correct detection rates of the clinical investigators; to assess the correct detection rates of both radiotracers for PCa lesions in a region-based analysis; to report the impact on diagnostic thinking (impact of PET/CT result on posttest vs. pretest probability of a correct diagnosis), therapeutic decision making (impact on the comprehensive process by which physicians make decisions about the PCa response), and adequacy of management changes by the Investigators at 3 time points (before PET, immediately after both PET studies, and at the end of follow-up) and by the expert panel (only at the end of follow-up), using 3 dedicated forms (supplemental materials); to compare the masked intra- and interreader agreements; and to assess the safety profile of 18F-PSMA-1007.

Statistical Analysis

Analysis was performed using SAS 9.4 or higher (SAS Institute), detailed in the supplemental materials. A P value of less than or equal to 0.05 was considered statistically significant. Descriptive statistics were calculated for quantitative variables; frequency counts by category were given for qualitative variables. Ninety-five percent CIs or interquartile ranges were given when appropriate. The intention-to-treat (ITT) population was the primary population for the analyses of efficacy endpoints and all baseline characteristics. The correct detection rate was determined for each reader individually. Generalized estimation equations were used to account for the correlations between readers’ assessments and to summarize the overall reader results (average reader). Patients for whom the expert panel could assess the true disease state on a patient level but for whom the affected region could not be identified by the expert panel were included as correct assessments on a patient basis. If, on a region basis, there was no region with a correct detection of recurrence compared with the standard of truth, then the patient was regarded as having a false-negative result. If at least in 1 region the reader and the expert panel detected a recurrence, independent of the other regions, then this result was classified as a true-positive result. Subgroup analyses were performed on the basis of the PSA level at baseline: less than 0.5 ng/mL, 0.5 ng/mL to less than 1.0 ng/mL, greater than or equal to 1.0 ng/mL to less than 2.0 ng/mL, and greater than or equal to 2.0 ng/mL. For the primary analysis on a patient level, 2 distinct analyses were performed by considering undetermined results as positive or negative for PCa recurrence. For subgroup and secondary analyses, undetermined results were considered negative for PCa recurrence. Intra- and interreader agreements were evaluated using pairwise and multiple Cohen κ-statistics. Each masked reader read 10% of the images twice (on separate occasions). Interreader agreement was assessed pairwise and across all 3 readers. The degree of agreement was defined as described by Landis and Koch (11).The sample size was selected to provide a power of at least 80% to detect a 10% difference in correct detection rates between the 2 products.

RESULTS

Population

From March 5, 2019, to October 8, 2020, 200 patients consented to this study; 195 were randomized, and 189 completed all follow-up assessments (Fig. 1). One patient ended study participation prematurely because he died 3.5 mo after PET imaging but was included in the ITT population. Most of the patients had previously undergone prostatectomy, and the median serum PSA level was 1.7 ng/mL. Study population characteristics are summarized in Table 1.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Trial chart.

View this table:
  • View inline
  • View popup
TABLE 1.

Patient Characteristics (Intention-to-Treat Population)

The median follow-up period for the ITT population was 8.3 mo (range, 2.9–16.1 mo), as its duration was extended because of the COVID-19 pandemic.

Primary Objective

Per-patient and per-region PET findings are detailed in the supplemental materials. At the patient level, the masked readers found evidence for PCa recurrence in 145–162 patients (76.3%–85.3%) with 18F-PSMA-1007 and 99–128 patients (52.1%–67.4%) with 18F-fluorocholine. Findings remained undetermined in 6–12 patients (3.2%–6.3%) with 18F-PSMA-1007 and 10–21 patients (5.3%–11.1%) with 18F-fluorocholine (supplemental materials). The expert panel confirmed PCa recurrence according to the standard of truth in 179 of 190 cases (94%).

The overall proportion of patients with correct detection rates for PCa lesions with 18F-PSMA-1007 was 0.82 (95% CI, 0.78–0.86) or 0.77 (95% CI, 0.72–0.82) when undetermined results were considered positive or negative for malignancy, respectively; these values were statistically superior to the value 0.65 (95% CI, 0.60–0.71) or 0.57 (95% CI, 0.51–0.62) obtained with 18F-fluorocholine when undetermined results were considered positive or negative for PCa, respectively (P < 0.0001) (Table 2). Thus, the primary endpoint was reached.

View this table:
  • View inline
  • View popup
TABLE 2.

Patient-Level Overall Proportion of Patients With Correct Rate of Detection of Recurrent PCa According to Standard of Truth and Positive Predictive Value (ITT Population) (n = 190)

For both study drugs, the correct detection rate for PCa recurrence was higher for patients with higher PSA levels. For all examined PSA-level subgroups, the correct detection rate was statistically higher for 18F-PSMA-1007 (Table 3).

View this table:
  • View inline
  • View popup
TABLE 3.

Patient-Level Proportion of Patients With Correct Rate of Detection of PCa Lesions by PSA Level at Baseline (ITT Population) (n = 190)

Masked intra- and interreader agreements for the detection of metastases (patient level) ranged from 0.24 to 0.73 and from 0.30 to 0.36 for 18F-PSMA-1007 and from 0.48 to 0.72 and 0.34 to 0.40 for 18F-fluorocholine, respectively (supplemental materials).

Secondary Objectives

Comparison of Patient-Based Correct Detection Rates According to Investigator Findings

On the basis of the clinical investigators’ overall findings, the correct detection rates were 0.80 (95% CI, 0.74–0.86) for 18F-PSMA-1007 and 0.50 (95% CI, 0.42–0.57) for 18F-fluorocholine (P < 0.0001).

Comparison of Region-Based Correct Detection Rates According to Masked Readers’ Findings

In the 72 patients for whom 1 or more regions could be assessed by the expert panel, there were 78 regions with confirmed PCa lesions. The most common sites for PCa lesions were the pelvis (59 patients) and the spine (6 patients) (supplemental materials). In the patients considered to have a positive PET result, more suggestive lesions were detected with 18F-PSMA-1007 than with 18F-fluorocholine, especially in patients with 3 or more lesions.

Overall composite region-level sensitivities were 0.77 (95% CI, 0.69–0.84) for 18F-PSMA-1007 PET and 0.57 (95% CI, 0.48–0.67) for 18F-fluorocholine PET (P < 0.0001).

Impact on Diagnostic Thinking, Therapeutic Decision Making, and Adequacy of Therapy Changes

The investigator assessments of the changes in diagnostic thinking after both PET/CT examinations and at the end of follow-up are summarized in Tables 4 and 5 and the supplemental materials. Treatment plans before and after PET/CT examinations were available in 187 patients. Treatment plans were changed in 100 patients; 89 of the changes were major (supplemental materials). Changes in diagnostic thinking due to PET/CT were reported in 149 patients. Diagnostic thinking was unchanged in 41 patients (including 3 with no reported answer in the questionnaire). In the 149 patients for whom there were changes in diagnostic thinking, 18F-PSMA-1007 contributed more in 93 patients (62%), both tracers contributed equally in 49 patients (33%), and 18F-fluorocholine contributed more in 4 patients (3%).

View this table:
  • View inline
  • View popup
TABLE 4.

Change in Diagnostic Thinking After Both PET/CT Scans (ITT Population) (n = 190)*

View this table:
  • View inline
  • View popup
TABLE 5.

Change in Diagnostic Thinking After Both PET Scans and Influence at End of Follow-up (ITT Population) (n = 190)*

In 122 patients, PET/CT led to a more accurate diagnosis that benefited them. In 11 patients, PET/CT was not to the benefit of the patient, and in 45 patients, PET/CT did not exert a positive or negative influence. In the 122 patients with a more accurate diagnosis after PET/CT that benefited them, 18F-PSMA-1007 contributed more in 88 patients, 18F-fluorocholine contributed more in only 6 patients, and both contributed equally in 27 patients.

Safety Profile of 18F-PSMA-1007

There were no serious adverse events. No patient discontinued study participation because of an adverse event. Four patients had 4 events (toothache, diarrhea, chest discomfort, and arterial hypertension) after the administration of 18F-PSMA-1007, and 1 patient had 1 event (shoulder pain) after the administration of 18F-fluorocholine. None of the adverse events was considered to be attributable to the study drug.

DISCUSSION

To our knowledge, the present study is the first multicenter, crossover randomized study to compare 18F-PSMA-1007 and 18F-fluorocholine for the localization of biochemical recurrence of PCa. The correct detection rate was significantly higher with 18F-PSMA-1007 PET/CT than with 18F-fluorocholine PET/CT. Results were similar for the population as a whole and for the 72 patients for whom individual lesions could be verified, either by biopsy or response to local treatment. The difference was especially pronounced in patients with lower serum PSA levels, allowing earlier, targeted salvage treatment. Our results for 18F-PSMA-1007 are in agreement with those reported in the literature for 68Ga-PSMA-11 (4,12–18). In a metaanalysis, Treglia et al. (19) also found similar results when comparing a PSMA tracer (68Ga-PSMA-11 or 64Cu-PSMA-617) and radiocholine. Because the results obtained with the various PSMA ligands are generally similar, it is generally accepted that the PSMA ligands are interchangeable for this indication. PSMA ligands radiolabeled with 18F have wider accessibility than those radiolabeled with 68Ga.

The investigator assessments after PET/CT and at the end of follow-up demonstrated the superiority of 18F-PSMA-1007 over 18F-fluorocholine in identifying sites of recurrence. The impact of 18F-PSMA-1007 was to benefit the patient in most cases. These results are likely linked to the higher correct detection rate for 18F-PSMA-1007. In previous studies with 18F-fluorocholine (13,20) and 68Ga-PSMA-11 (5,21), rates of impact on patient management of 39%–58% were reported. Our study is consistent with published data on 18F-fluorocholine and demonstrates a higher impact of 18F-PSMA-1007 on patient management.

The strengths of our study are its prospective, multicenter, randomized crossover design. Limitations include the lack of histopathology for most lesions. Because obtaining histopathology is often ethically questionable or medically impractical, our standard of truth was a composite based on biopsy, response to local therapy, imaging, and changes in serum PSA levels during 6 mo of follow-up, as established by an independent panel of experts. The use of the independent panel removed potential bias in determining “truth” while modeling what is done in “real-life” practice.

In this work, we found that 18F-PSMA-1007 had an impact on diagnostic thinking and therapeutic decision making and that therapy changes were more beneficial when based on 18F-PSMA-1007 PET/CT findings than when based on 18F-fluorocholine PET/CT findings (Fig. 2). However, we did not make a statistical comparison of these data because the study was not powered for this purpose.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

62-y-old patient with history of PCa (International Society of Urological Pathology grade 3; PSA level of 5.7 ng/mL), initially treated with prostatectomy (pT3N0R0), prostate bed radiation therapy, and 6 mo of androgen deprivation therapy (ADT), presenting with PSA recurrence (0.72 ng/mL). 18F-PSMA-1007 PET/CT detected pelvic lymph nodes (red arrow) and bone metastases (green arrow) that were not detected by 18F-fluorocholine PET/CT. Therapeutic management changed from targeted radiation therapy before PET to ADT after PET, leading to drop in PSA level to 0.1 ng/mL at 6 mo. BW = body weight.

CONCLUSION

This prospective, multicenter, open-label, crossover randomized study demonstrated that 18F-PSMA-1007 PET/CT localizes PCa recurrence in significantly more patients than 18F-fluorocholine PET/CT, especially in patients with low PSA serum levels. 18F-PSMA-1007 PET/CT also had a higher impact on diagnostic thinking, therapeutic decision making, and therapy changes than 18F-fluorocholine PET/CT.

DISCLOSURE

This study was funded and supported by ABX Advanced Biochemical Compounds, Radeberg, Germany. Ines Rudolph and Alexander Hoepping work for ABX Advanced Biochemical Compounds. Charles Merlin has received personal fees and nonfinancial support from Curium Pharma and Novartis. Mathieu Gauthé has received personal fees and nonfinancial support from Astellas, Curium Pharma, and Novartis. The manuscript was edited for English language by Dr. Jay R Wiggins, PhD, and Dr. Kelsey L. Pomykala, MD, supported by ABX Advanced Biochemical Compounds. The ABX-CT-301 ClinicalTrials.gov number is NCT04102553. No other potential conflict of interest relevant to this article was reported.

KEY POINTS

QUESTION: Is 18F-PSMA-1007 superior to 18F-fluorocholine PET/CT for the localization of biochemical recurrence in PCa patients?

PERTINENT FINDINGS: In this prospective, open-label, randomized, crossover multicenter study that included 190 patients with PCa biochemical recurrence, we demonstrated that 18F-PSMA-1007 PET/CT localizes significantly more PCa lesions than 18F-fluorocholine PET/CT, especially when serum PSA levels are low.

IMPLICATIONS FOR PATIENT CARE: More accurate staging of recurrent PCa might lead to more beneficial decision making and patient management; a theranostic use of PSMA radioligands should be considered in recurrent PCa.

ACKNOWLEDGMENTS

We thank the following institutions and people for participating in this study: Hôpital Tenon—F. Montravers, C. Aveline, J.N. Talbot, T. Rusu, B. Mugnier, and N. Cailleux; HEGP—B. Clara, M. Bernardini, C. Smadja, H. Slimani, B. Truffault, and M. Homo Seban; CHRU Nancy—G. Karcher, P. Eschwege, M. Claudin, and D. Peiffert; Centre Léon Bérard—P. Pommier, C. Carrie, C. Laude, A. Serre, J.N. Badel, T. Mognetti, A. Lauret, and O. Osman; HCL—I. Morelec, A. Dhomps, J. Tordo, P. Got, C. Darcissac, F. Hallouard, P. Bonazza, and H. Belhouli; and Centre Jean Perrin—C. Bouvet, B. Barres, E. Villeneuve, C. Valla, M. Tempier, G. Loos, M. Chanchou, A. Kelly, J. Amat, P. Bouyon, L. Viala, F. Luzuy, J. Miroir, and F. Cachin.

Footnotes

  • Published online Nov. 23, 2022.

  • © 2023 by the Society of Nuclear Medicine and Molecular Imaging.

Immediate Open Access: Creative Commons Attribution 4.0 International License (CC BY) allows users to share and adapt with attribution, excluding materials credited to previous publications. License: https://creativecommons.org/licenses/by/4.0/. Details: http://jnm.snmjournals.org/site/misc/permission.xhtml.

REFERENCES

  1. 1.↵
    1. Dyba T,
    2. Randi G,
    3. Bray F,
    4. et al
    . The European cancer burden in 2020: incidence and mortality estimates for 40 countries and 25 major cancers. Eur J Cancer. 2021;157:308–347.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Uchio EM,
    2. Aslan M,
    3. Wells CK,
    4. Calderone J,
    5. Concato J
    . Impact of biochemical recurrence in prostate cancer among US veterans. Arch Intern Med. 2010;170:1390–1395.
    OpenUrlCrossRefPubMed
  3. 3.↵
    European Association of Urology. EAU guidelines: oncology guidelines. https://uroweb.org/individual-guidelines/oncology-guidelines/. Accessed January 9, 2023.
  4. 4.↵
    1. Crocerossa F,
    2. Marchioni M,
    3. Novara G,
    4. et al
    . Detection rate of prostate specific membrane antigen tracers for positron emission tomography/computerized tomography in prostate cancer biochemical recurrence: a systematic review and network meta-analysis. J Urol. 2021;205:356–369.
    OpenUrl
  5. 5.↵
    1. Morigi JJ,
    2. Stricker PD,
    3. van Leeuwen PJ,
    4. et al
    . Prospective comparison of 18F-fluoromethylcholine versus 68Ga-PSMA PET/CT in prostate cancer patients who have rising prostate-specific antigen after curative treatment and are being considered for targeted therapy. J Nucl Med. 2015;56:1185–1190.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    1. Cardinale J,
    2. Schäfer M,
    3. Benešová M,
    4. et al
    . Preclinical evaluation of 18F-PSMA-1007, a new prostate-specific membrane antigen ligand for prostate cancer imaging. J Nucl Med. 2017;58:425–431.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. Giesel FL,
    2. Hadaschik B,
    3. Cardinale J,
    4. et al
    . F-18 labelled PSMA-1007: biodistribution, radiation dosimetry and histopathological validation of tumor lesions in prostate cancer patients. Eur J Nucl Med Mol Imaging. 2017;44:678–688.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Giesel FL,
    2. Knorr K,
    3. Spohn F,
    4. et al
    . Detection efficacy of 18F-PSMA-1007 PET/CT in 251 patients with biochemical recurrence of prostate cancer after radical prostatectomy. J Nucl Med. 2019;60:362–368.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Sprute K,
    2. Kramer V,
    3. Koerber SA,
    4. et al
    . Diagnostic accuracy of 18F-PSMA-1007 PET/CT imaging for lymph node staging of prostate carcinoma in primary and biochemical recurrence. J Nucl Med. 2021;62:208–213.
    OpenUrlAbstract/FREE Full Text
  10. 10.↵
    1. Grünig H,
    2. Maurer A,
    3. Thali Y,
    4. et al
    . Focal unspecific bone uptake on [18F]-PSMA-1007 PET: a multicenter retrospective evaluation of the distribution, frequency, and quantitative parameters of a potential pitfall in prostate cancer imaging. Eur J Nucl Med Mol Imaging. 2021;48:4483–4494.
    OpenUrl
  11. 11.↵
    1. Landis JR,
    2. Koch GG
    . The measurement of observer agreement for categorical data. Biometrics. 1977;33:159–174.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Marzola MC,
    2. Chondrogiannis S,
    3. Ferretti A,
    4. et al
    . Role of 18F-choline PET/CT in biochemically relapsed prostate cancer after radical prostatectomy: correlation with trigger PSA, PSA velocity, PSA doubling time, and metastatic distribution. Clin Nucl Med. 2013;38:e26–e32.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. Gillebert Q,
    2. Huchet V,
    3. Rousseau C,
    4. et al
    . 18F-fluorocholine PET/CT in patients with occult biochemical recurrence of prostate cancer: detection rate, impact on management and adequacy of impact—a prospective multicentre study. PLoS One. 2018;13:e0191487.
    OpenUrl
  14. 14.
    1. Perera M,
    2. Papa N,
    3. Roberts M,
    4. et al
    . Gallium-68 prostate-specific membrane antigen positron emission tomography in advanced prostate cancer: updated diagnostic utility, sensitivity, specificity, and distribution of prostate-specific membrane antigen-avid lesions—a systematic review and meta-analysis. Eur Urol. 2020;77:403–417.
    OpenUrlCrossRefPubMed
  15. 15.
    1. Mapelli P,
    2. Incerti E,
    3. Ceci F,
    4. Castellucci P,
    5. Fanti S,
    6. Picchio M
    . 11C- or 18F-choline PET/CT for imaging evaluation of biochemical recurrence of prostate cancer. J Nucl Med. 2016;57(suppl):43S–48S.
    OpenUrlAbstract/FREE Full Text
  16. 16.
    1. Mingels C,
    2. Bohn KP,
    3. Rominger A,
    4. Afshar-Oromieh A,
    5. Alberts I
    . Diagnostic accuracy of [18F]PSMA-1007 PET/CT in biochemical recurrence of prostate cancer. Eur J Nucl Med Mol Imaging. 2022;49:2436–2444.
    OpenUrl
  17. 17.
    1. Lecouvet FE,
    2. Oprea-Lager DE,
    3. Liu Y,
    4. et al
    . Use of modern imaging methods to facilitate trials of metastasis-directed therapy for oligometastatic disease in prostate cancer: a consensus recommendation from the EORTC Imaging Group. Lancet Oncol. 2018;19:e534–e545.
    OpenUrlCrossRefPubMed
  18. 18.↵
    1. Chevalme Y-M,
    2. Boudali L,
    3. Gauthé M,
    4. et al
    . Survey by the French Medicine Agency (ANSM) of the imaging protocol, detection rate, and safety of 68Ga-PSMA-11 PET/CT in the biochemical recurrence of prostate cancer in case of negative or equivocal 18F-fluorocholine PET/CT: 1084 examinations. Eur J Nucl Med Mol Imaging. 2021;48:2935–2950.
    OpenUrl
  19. 19.↵
    1. Treglia G,
    2. Pereira Mestre R,
    3. Ferrari M,
    4. et al
    . Radiolabelled choline versus PSMA PET/CT in prostate cancer restaging: a meta-analysis. Am J Nucl Med Mol Imaging. 2019;9:127–139.
    OpenUrl
  20. 20.↵
    1. Soyka JD,
    2. Muster MA,
    3. Schmid DT,
    4. et al
    . Clinical impact of 18F-choline PET/CT in patients with recurrent prostate cancer. Eur J Nucl Med Mol Imaging. 2012;39:936–943.
    OpenUrlCrossRefPubMed
  21. 21.↵
    1. Han S,
    2. Woo S,
    3. Kim YJ,
    4. Suh CH
    . Impact of 68Ga-PSMA PET on the management of patients with prostate cancer: a systematic review and meta-analysis. Eur Urol. 2018;74:179–190.
    OpenUrlCrossRef
  • Received for publication July 30, 2022.
  • Revision received October 27, 2022.
View Abstract
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 64 (4)
Journal of Nuclear Medicine
Vol. 64, Issue 4
April 1, 2023
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Phase III Study of 18F-PSMA-1007 Versus 18F-Fluorocholine PET/CT for Localization of Prostate Cancer Biochemical Recurrence: A Prospective, Randomized, Crossover Multicenter Study
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Phase III Study of 18F-PSMA-1007 Versus 18F-Fluorocholine PET/CT for Localization of Prostate Cancer Biochemical Recurrence: A Prospective, Randomized, Crossover Multicenter Study
Pierre Olivier, Anne-Laure Giraudet, Andrea Skanjeti, Charles Merlin, Pierre Weinmann, Ines Rudolph, Alexander Hoepping, Mathieu Gauthé
Journal of Nuclear Medicine Apr 2023, 64 (4) 579-585; DOI: 10.2967/jnumed.122.264743

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Phase III Study of 18F-PSMA-1007 Versus 18F-Fluorocholine PET/CT for Localization of Prostate Cancer Biochemical Recurrence: A Prospective, Randomized, Crossover Multicenter Study
Pierre Olivier, Anne-Laure Giraudet, Andrea Skanjeti, Charles Merlin, Pierre Weinmann, Ines Rudolph, Alexander Hoepping, Mathieu Gauthé
Journal of Nuclear Medicine Apr 2023, 64 (4) 579-585; DOI: 10.2967/jnumed.122.264743
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • ACKNOWLEDGMENTS
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • Reply: One Bite from the Apple, One Bite from the Orange in the PRECISE-MDT Study and Limitations of Retrospective Study Design and Potential Bias in the PRECISE-MDT Study
  • FAP and PSMA Expression by Immunohistochemistry and PET Imaging in Castration-Resistant Prostate Cancer: A Translational Pilot Study
  • Diagnostic Efficacy of Various Imaging Modalities Across Different Stages of Prostate Cancer: A Network Meta-Analysis of Diagnostic Studies
  • Google Scholar

More in this TOC Section

  • First-in-Human Study of 18F-Labeled PET Tracer for Glutamate AMPA Receptor [18F]K-40: A Derivative of [11C]K-2
  • Detection of HER2-Low Lesions Using HER2-Targeted PET Imaging in Patients with Metastatic Breast Cancer: A Paired HER2 PET and Tumor Biopsy Analysis
  • [11C]Carfentanil PET Whole-Body Imaging of μ-Opioid Receptors: A First in-Human Study
Show more Clinical Investigation

Similar Articles

Keywords

  • PET/CT
  • prostatic neoplasms
  • prostate-specific antigen
  • decision making
SNMMI

© 2025 SNMMI

Powered by HighWire