Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleFEATURED BASIC SCIENCE ARTICLE
Open Access

Substitution of l-Tryptophan by α-Methyl-l-Tryptophan in 177Lu-RM2 Results in 177Lu-AMTG, a High-Affinity Gastrin-Releasing Peptide Receptor Ligand with Improved In Vivo Stability

Thomas Günther, Sandra Deiser, Veronika Felber, Roswitha Beck and Hans-Jürgen Wester
Journal of Nuclear Medicine September 2022, 63 (9) 1364-1370; DOI: https://doi.org/10.2967/jnumed.121.263323
Thomas Günther
Chair of Pharmaceutical Radiochemistry, Technical University of Munich, Garching, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sandra Deiser
Chair of Pharmaceutical Radiochemistry, Technical University of Munich, Garching, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Veronika Felber
Chair of Pharmaceutical Radiochemistry, Technical University of Munich, Garching, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Roswitha Beck
Chair of Pharmaceutical Radiochemistry, Technical University of Munich, Garching, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hans-Jürgen Wester
Chair of Pharmaceutical Radiochemistry, Technical University of Munich, Garching, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

Theranostic applications targeting the gastrin-releasing peptide receptor (GRPR) have shown promising results. When compared with other peptide ligands for radioligand therapy, the most often used GRPR ligand, DOTA-Pip5-d-Phe6-Gln7-Trp8-Ala9-Val10-Gly11-His12-Sta13-Leu14-NH2 (RM2), may be clinically impacted by limited metabolic stability. With the aim of improving the metabolic stability of RM2, we investigated whether the metabolically unstable Gln7-Trp8 bond within the pharmacophore of RM2 can be stabilized via substitution of l-Trp8 by α-methyl-l-tryptophan (α-Me-l-Trp) and whether the corresponding DOTAGA analog might also be advantageous. A comparative preclinical evaluation of 177Lu-α-Me-l-Trp8-RM2 (177Lu-AMTG) and its DOTAGA counterpart (177Lu-AMTG2) was performed using 177Lu-RM2 and 177Lu-NeoBOMB1 as reference compounds. Methods: Peptides were synthesized by solid-phase peptide synthesis and labeled with 177Lu. Lipophilicity was determined at pH 7.4 (logD7.4). Receptor-mediated internalization was investigated on PC-3 cells (37°C, 60 min), whereas GRPR affinity (half-maximal inhibitory concentration) was determined on both PC-3 and T-47D cells. Stability toward peptidases was examined in vitro (human plasma, 37°C, 72 ± 2 h) and in vivo (murine plasma, 30 min after injection). Biodistribution studies were performed at 24 h after injection, and small-animal SPECT/CT was performed on PC-3 tumor–bearing mice at 1, 4, 8, 24, and 28 h after injection. Results: Solid-phase peptide synthesis yielded 9%–15% purified labeling precursors. 177Lu labeling proceeded quantitatively. Compared with 177Lu-RM2, 177Lu-AMTG showed slightly improved GRPR affinity, a similar low internalization rate, slightly increased lipophilicity, and considerably improved stability in vitro and in vivo. In vivo, 177Lu-AMTG exhibited the highest tumor retention (11.45 ± 0.43 percentage injected dose/g) and tumor-to-blood ratio (2,702 ± 321) at 24 h after injection, as well as a favorable biodistribution profile. As demonstrated by small-animal SPECT/CT imaging, 177Lu-AMTG also revealed a less rapid clearance from tumor tissue. Compared with 177Lu-AMTG, 177Lu-AMTG2 did not show any further benefits. Conclusion: The results of this study, particularly the superior metabolic stability of 177Lu-AMTG, strongly recommend a clinical evaluation of this novel GRPR-targeted ligand to investigate its potential for radioligand therapy of GRPR-expressing malignancies.

  • AMTG
  • GRPR
  • RM2
  • prostate cancer
  • increased metabolic stability
  • NeoBOMB1

Radioligand therapy has emerged as a powerful alternative to conventional treatment options in oncology. This emergence can be attributed mainly to the success of DOTATOC- and DOTATATE-based theranostics in the case of neuroendocrine tumors and to prostate-specific membrane antigen (PSMA)–targeted inhibitors in the case of prostate cancer (1,2). In view of the overexpression of the gastrin-releasing peptide receptor (GRPR, bombesin-2 receptor) at a high density and frequency already in early stages of prostate cancer (∼5,000 disintegrations/min [dpm]/mg of tissue, with >2,000 dpm/mg being considered clinically relevant) and breast cancer (∼10,000 dpm/mg), GRPR has been identified as a promising target for both cancer types (3,4).

In a recent study, 50 patients with biochemically recurrent prostate cancer were examined with either 68Ga-PSMA11 or 18F-DCFPyL PET/CT and additionally with 68Ga-RM2 PET/MRI (where RM2 is DOTA-Pip5-d-Phe6-Gln7-Trp8-Ala9-Val10-Gly11-His12-Sta13-Leu14-NH2). Thirty-six lesions were visible only with 68Ga-PSMA11/18F-DCFPyL PET/CT, and 7 only with 68Ga-RM2 PET/MRI, which again suggests a complementary role for GRPR- and PSMA-targeted theranostics (5). Moreover, estrogen receptor–rich breast cancer (estrogen receptor being expressed in over 80% of all breast cancers), in particular, shows high GRPR expression, which is retained in 95% of nodal metastases (6,7). Not surprisingly, successful high-contrast PET imaging of breast cancer using 68Ga-NOTA-RM26 or 68Ga-RM2 has already been described (8,9).

The 2 most promising GRPR-targeted radiopharmaceuticals, 68Ga-RM2 and 68Ga-NeoBOMB1, have already shown favorable initial results and are being assessed in phase 1 and 2 clinical studies (10–13). A first-in-humans study on 177Lu-RM2 in PSMA-negative/GRPR-positive prostate cancer revealed encouraging dosimetry data (14). Nevertheless, limited metabolic stability of some bombesin derivatives, such as RM2, is well known and caused mainly by the neutral endopeptidase (Enzyme Commission no. 3.4.24.11), which reportedly cleaves linear peptides at the N terminus side of hydrophobic amino acids (15). Incubation of 177Lu-labeled DOTA-4-aminobenzoyl-Gln7- Trp8-Ala9- Val10- Gly11- His12- Leu13-Met14-NH2 (AMBA) in murine and human plasma in vitro revealed several cleavage sites, especially at the C terminus and the Gln7-Trp8 site (16). Similar observations were made in 5 healthy patients, as the administered 68Ga-RM2 showed only 19% intact tracer in blood at 65 min after injection (17). Considering this rather small fraction of intact compound early after injection, a metabolically stabilized RM2 analog could result in improved tumor uptake, tumor retention, and thus tumor dose. In recent years, many groups developed bombesin analogs that were modified at the C or N termini, but not within the pharmacophoric sequence (Gln7-Trp8-Ala9-Val10-Gly11-His12) (18–22).

As we hypothesized that the use of statine (i.e., Sta13) at the C terminus of RM2 and its derivatives would result in sufficient metabolic stabilization at this part of the molecule, we concluded that further improvements might be possible by stabilizing the Gln7-Trp8 sequence. For this purpose, we substituted α-methyl-l-tryptophan (α-Me-l-Trp) for l-Trp8 in 177Lu-RM2 and its DOTAGA analog (Fig. 1) and evaluated these novel compounds alongside the potent reference ligands 177Lu-RM2 and 177Lu-NeoBOMB1. The comparative preclinical evaluation comprises affinity studies (half-maximal inhibitory concentration, or IC50) on PC-3 and T-47D cells, quantification of receptor-mediated internalization on PC-3 cells, determination of lipophilicity at pH 7.4 (logD7.4), investigations of stability against peptidases in vitro in human plasma and in vivo in plasma and urine of mice, and biodistribution studies on PC-3 tumor–bearing mice.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Chemical structure of RM2 and its α-Me-l-Trp (α-Me-l-Trp8) modified derivatives AMTG and AMTG2, as well as reference ligand NeoBOMB1. Structural differences from RM2 are highlighted in red.

MATERIALS AND METHODS

Chemical Synthesis and Labeling Procedures

RM2 derivatives were prepared via standard Fmoc-based solid-phase peptide synthesis using H-Rink amide ChemMatrix resin (35- to 100-mesh particle size, 0.4–0.6 mmol/g loading; Merck KGaA). NeoBOMB1 was synthesized according to a reported procedure (20) and purified by reversed-phase high-performance liquid chromatography (RP-HPLC).

Both natLu and 177Lu labeling was according to a modified procedure (23). The radiolabeled reference, 3-125I-d-Tyr6-MJ9 (Supplemental Figs. 1 and 2; supplemental materials are available at http://jnm.snmjournals.org), was prepared according to a reported procedure (24). A detailed description of the synthesis, labeling, and characterization of RM2 and its analogs is provided in Supplemental Figures 3–12.

In Vitro Experiments

A detailed description of all cell-based experiments is provided in the supplemental materials.

Affinity Determinations (IC50) and Internalization Studies

Competitive binding studies were performed on both PC-3 and T-47D cells (1.5 × 105 cells in 1 mL/well) via incubation at room temperature for 2 h using 3-125I-d-Tyr6-MJ9 (0.2 nM/well) as a radiolabeled reference (n = 3). Internalization studies of the 177Lu-labeled conjugates (1.0 nM/well) were performed on PC-3 cells (1.5 × 105 cells in 1 mL/well) at 37°C for 1 h (n = 6). Data were corrected for nonspecific binding (competition by 10−3 M natLu-RM2).

Determination of Lipophilicity (n-Octanol–Phosphate-Buffered Saline Distribution Coefficient, logD7.4)

Approximately 1 MBq of the 177Lu-labeled compound was dissolved in 1 mL of phosphate-buffered saline (pH 7.4) and n-octanol (v/v = 1/1). After stirring for 3 min at room temperature in a vortex mixer and subsequent centrifugation at 9,000 rpm for 5 min (Biofuge 15; Heraeus Sepatech GmbH), 200-μL aliquots of both layers were measured separately in a γ-counter. The experiment was repeated at least 5 times.

In Vitro Stability Studies

Metabolic stability in vitro was determined through a procedure published by Linder et al. that was slightly modified (16). Immediately after labeling, 200 μL of human plasma were added and the mixture was incubated at 37°C for 72 ± 2 h. Proteins were precipitated by treatment with ice-cold EtOH (150 μL) and ice-cold MeCN (450 μL), followed by centrifugation (13,000 rpm, 20 min). The supernatants were decanted and further centrifuged (13,000 rpm, 10 min) using a Costar Spin-X (Corning) centrifuge tube filter (0.45 μm). The filtrated plasma samples were analyzed using radio–RP-HPLC.

In Vivo Experiments

All animal experiments were conducted in accordance with general animal welfare regulations in Germany (German animal protection act, as amended on 18.05.2018, article 141 G v. 29.3.2017 I 626, approval ROB-55.2-2532.Vet_02-18-109) and the institutional guidelines for the care and use of animals.

In Vivo Stability Studies

Approximately 30–40 MBq (1 nmol, 150 μL) of the 177Lu-labeled compounds were injected into the tail vein of anesthetized CB17-SCID mice (n = 3). After euthanasia at 30 min after injection, blood and urine samples were collected. Blood proteins were precipitated by treatment with ice-cold MeCN (v/v = 1/1), followed by centrifugation (13,000 rpm, 20 min). The supernatants were decanted and further centrifuged (13,000 rpm, 10 min) using a Costar Spin-X centrifuge tube filter (0.45 μm). The filtrated plasma samples and the urine samples were analyzed using radio–RP-HPLC.

Biodistribution and Small-Animal SPECT/CT Imaging Studies

A detailed description of tumor inoculation is provided in the supplemental materials. Approximately 2–5 MBq (100 pmol, 150 μL) of the 177Lu-labeled GRPR ligands were injected into the tail vein of anesthetized (2% isoflurane) PC-3 tumor–bearing mice (biodistribution, n = 4; imaging, n = 1).

For biodistribution studies, organs were removed, weighed, and measured in a γ-counter (Perkin Elmer) after euthanasia at 24 h after injection.

Imaging studies were performed on a MILabs VECTor4 small-animal SPECT/PET/optical imaging/CT device (MILabs). Data were reconstructed using the MILabs Rec software (version 10.02) and a pixel-based algorithm (similarity-regulated ordered-subsets expectation maximization), followed by data analysis using PMOD software (version 4.0; PMOD Technologies LLC). Static images were recorded at t = 1, 4, 8, 24, and 28 h after injection with an acquisition time of t + (45–60 min) using a high-energy general-purpose rat and mouse collimator and a stepwise multiplanar bed movement.

For all competition studies, 3.62 mg/kg (40 nmol) of natLu-RM2 (10−3 M in phosphate-buffered saline) were coadministered.

RESULTS

Synthesis and Radiolabeling

Uncomplexed ligands were synthesized via standard Fmoc-based solid-phase peptide synthesis, yielding 9%–15% of each labeling precursor after purification by RP-HPLC (chemical purity > 98%, determined by RP-HPLC at λ = 220 nm). Complexation of all ligands with a 2.5-fold excess of natLuCl3 resulted in quantitative yields. The remaining free Lu3+ did not affect the cell-based assay in a brief competition study (Supplemental Fig. 13); thus, purification before affinity studies was dispensed with. 125I-iodination of d-Tyr6-MJ9 by means of the Iodo-Gen (Pierce Biotechnology, Inc.) method resulted in 3-125I-d-Tyr6-MJ9 with radiochemical yields of 33%–48% and radiochemical purities of more than 98% after RP-HPLC purification. 177Lu labeling of all compounds was performed manually, each resulting in quantitative radiochemical yields, radiochemical purities of more than 98%, and molar activities of 40 ± 10 GBq/μmol. All 177Lu-labeled ligands were used without further purification.

In Vitro Characterization

In vitro data on the examined bombesin-based ligands are summarized in Figure 2 and Supplemental Table 1. The cold counterpart of 3-125I-d-Tyr6-MJ9 showed an IC50 of 1.3 ± 0.4 nM on PC-3 cells. The natLu-labeled compounds exhibited IC50 values in a range of 3.0–4.7 on PC-3 cells and 1.0–4.6 nM on T-47D cells. 177Lu-α-Me-l-Trp8-RM2 (177Lu-AMTG) and 177Lu-RM2 were internalized by PC-3 cells within 1 h in similar amounts (3.03% ± 0.18% vs. 2.92% ± 0.20%). 177Lu-DOTAGA-α-Me-l-Trp8-RM2 (177Lu-AMTG2) (5.88% ± 0.33%) and 177Lu-NeoBOMB1 (13.91% ± 0.64%) were taken up in higher amounts. Whereas the distribution coefficients (logD7.4) were quite similar for 177Lu-RM2 and its analogs (−2.3 to −2.5), 177Lu-NeoBOMB1 was considerably more lipophilic (−0.57 ± 0.03). The highest amounts of intact compound in vitro in human plasma were found for 177Lu-AMTG (77.7% ± 8.7%). Whereas 177Lu-AMTG2 and 177Lu-NeoBOMB1 exhibited only a slightly reduced stability in vitro (66.2% ± 5.1% vs. 61.9% ± 2.1%), only 38.7% ± 9.3% intact 177Lu-RM2 was found after incubation in human plasma at 37°C for 72 ± 2 h (Fig. 2; Supplemental Fig. 14).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Preclinical data of nat/177Lu-RM2 (red), nat/177Lu-NeoBOMB1 (gray), nat/177Lu-AMTG (green), and nat/177Lu-AMTG2 (blue). (A) Affinity data on PC-3 and T-47D cells (1.5 × 105 cells/mL/well) using 3-125I-d-Tyr6-MJ9 (0.2 nM/well) as radiolabeled reference (2 h, room temperature, Hanks’ balanced salt solution plus 1% bovine serum albumin [v/v]). (B) GRPR-mediated internalization (0.25 pmol/well) on PC-3 cells as percentage of applied activity (incubation at 37°C for 1 h, Dulbecco modified Eagle medium/F-12 plus 5% bovine serum albumin [v/v], 1.5 × 105 cells/mL/well). Data were corrected for nonspecific binding (10−3 M natLu-RM2). (C) Lipophilicity at pH 7.4 (logD7.4). (D) Metabolic stability in vitro in human plasma (left) (37°C, 72 ± 2 h; n = 4), and metabolic stability in vivo in murine plasma (middle) and murine urine (right) at 30 min after injection (n = 3). Data are expressed as mean ± SD. Metabolic stability of 177Lu-RM2 derivatives was determined in vitro and in vivo.

In Vivo Characterization

In vivo stability in murine plasma at 30 min after injection was highest for 177Lu-AMTG (92.9% ± 0.7% intact tracer). Again, slightly decreased metabolic stability was observed for 177Lu-NeoBOMB1 (75.9% ± 0.6%) and 177Lu-AMTG2 (77.6% ± 3.1%), whereas 177Lu-RM2 was quite unstable (11.4% ± 3.7%). In addition to these findings, 177Lu-AMTG and 177Lu-AMTG2 were excreted into the urine at 30 min after injection, predominantly as intact tracers (68.2% ± 3.1% and 61.6% ± 1.6%, respectively) (Fig. 2; Supplemental Figs. 15 and 16). Interestingly, after injection of 177Lu-RM2 and 177Lu-NeoBOMB1, radioactivity appeared in the urine almost quantitatively in the form of their metabolites (0.5% ± 0.1% vs. 3.9% ± 1.3% intact tracer).

Biodistribution studies on PC-3 tumor–bearing mice were performed at 24 h after injection (Table 1). 177Lu-RM2 and its derivatives showed low activity levels in most organs at 24 h after injection, indicating a rapid clearance from nontumor tissue, as is especially important for blood and GRPR-positive organs such as pancreas and intestine. 177Lu-NeoBOMB1 showed increased activity levels in several nontumor organs at 24 h after injection, particularly in lung, liver, spleen, pancreas, intestine, and adrenals. Bone uptake was slightly enhanced for 177Lu-RM2, a finding that was attributed to incomplete labeling (radiochemical yield, ∼95%; chromatogram not shown) and thus free 177LuCl3. Tumor retention was comparable for all compounds except 177Lu-AMTG, which exhibited distinctly increased values at 24 h after injection (7.2–8.5 vs. 11.5 percentage injected dose per gram; %ID/g). Not surprisingly, 177Lu-AMTG showed the highest tumor-to-background ratios at 24 h after injection. The tumor-to-blood ratio of 177Lu-AMTG (2,702 ± 321) was almost 4 times higher than that of 177Lu-RM2 and 177Lu-AMTG2 and approximately 15 times higher than that of 177Lu-NeoBOMB1 (Supplemental Table 2).

View this table:
  • View inline
  • View popup
TABLE 1.

Biodistribution of 177Lu-RM2, 177Lu-NeoBOMB1, 177Lu-AMTG, and 177Lu-AMTG2 in Selected Organs at 24 Hours After Injection in PC-3 Tumor–Bearing CB17-SCID Mice (100 pmol Each)

Small-animal SPECT/CT studies with 177Lu-RM2 and 177Lu-AMTG at 1, 4, 8, 24, and 28 h after injection in PC-3 tumor–bearing mice revealed low background activity for both tracers at 4 h and beyond and, for 177Lu-AMTG, considerably higher activity in both tumor and pancreas (Fig. 3). For both tracers, specificity of tumor uptake was confirmed via competition experiments with an excess of natLu-RM2 (Table 1; Supplemental Fig. 17).

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Maximum-intensity projection of PC-3 tumor–bearing CB17-SCID mice injected with 177Lu-RM2 and 177Lu-AMTG (100 pmol each). Images were acquired at 1, 4, 8, 24, and 28 h after injection into PC-3 tumors (arrows). p.i. = after injection.

DISCUSSION

With regard to radioligand therapy, the 2 most promising GRPR ligands, 68Ga-RM2 and 68Ga-NeoBOMB1, present some disadvantages: 68Ga-RM2 suffers from rapid metabolic degradation (17), which is why tumor accumulation and tumor dose for 177Lu-RM2 are likely limited as well—especially important in the context of radioligand therapy. In contrast, 177Lu-NeoBOMB1, which exhibits a higher metabolic stability in vivo, shows enhanced activity retention in tumor tissue but also in blood (19). This characteristic results in unfavorable dosimetry and higher doses to the red bone marrow (25). With the aim of retaining the excellent pharmacokinetics of RM2, we substituted the unnatural amino acid α-Me-l-Trp for the metabolically less stable Gln7-Trp8 sequence of 177Lu-RM2 and its DOTAGA analog and compared these new ligands with 177Lu-RM2 and 177Lu-NeoBOMB1 as references.

Synthesis was easily accessible via solid-phase peptide synthesis, and complexation with natLu or 177Lu proceeded quantitatively. All 4 compounds contain a similar pharmacophore typical of bombesin analogs, resulting in high affinities that were in the range of IC50 values reported for natIn-RM2 (9.3 nM), several natGa-RM26 derivatives (2.3–10.0 nM), natGa-NeoBOMB1 (2.5 nM), and SB3 (3.5 nM) (18,19,21,26). Apart from natLu-AMTG2, higher cellular uptake of 3-125I-d-Tyr6-MJ9, as well as slightly higher IC50 values on PC-3 cells than on T-47D cells, was observed (Supplemental Figs. 18 and 19). These findings were attributed to an increased number of receptors on PC-3 cells.

We could show that α-Me-l-Trp–for–l-Trp8 and DOTAGA-for-DOTA substitution had only minimal impact on GRPR affinity, lipophilicity (logD7.4), and receptor-mediated internalization, demonstrating that these modifications might allow the in vivo kinetics of 177Lu-RM2 to be kept almost unaffected. In contrast, higher internalization levels and lipophilicity already indicate the in vivo limitations of 177Lu-NeoBOMB1.

Besides retaining the favorable in vitro data of 177Lu-RM2, the primary aim of this study was to chemically stabilize the Gln-Trp bond to potentially improve its longtime behavior in vivo. Comparative stability studies in vitro and in vivo, as well as the resulting biodistribution profiles, substantiated our working hypothesis of addressing the major metabolic instability at the Gln-Trp site in RM2 and other bombesinlike compounds. Both 177Lu-AMTG and 177Lu-AMTG2 exhibited equal or even increased amounts of intact compound in human plasma in vitro and in murine plasma and urine in vivo, in comparison with the 2 references. For 68Ga-RM2 and 177Lu-NeoBOMB1, the fraction of intact tracer in murine blood was reported to be 55% (15 min after injection) (27) and 90% (30 min after injection) (19), respectively, which are lower than the value we determined for 177Lu-AMTG (30 min after injection).

Unlike Linder et al. in a stability study on 177Lu-AMBA (16), we observed fewer metabolites for each ligand after incubation in human plasma (Supplemental Fig. 14), as can be explained by the C terminus modifications present in each of the 4 compounds tested in this study. Popp et al. observed 1 major and 2 minor metabolites for 68Ga-RM2 in murine plasma at 15 min after injection (27), whereas we detected only 1 major and 1 minor metabolite for 177Lu-RM2 at 30 min after injection. This difference could be due either to our analysis method or to the effect reported by Linder et al. that the minor metabolites can be further metabolized to yield the major metabolite, the longer the circulation in vivo takes place.

Not surprisingly, increased metabolic stability observed in human and murine plasma for 177Lu-AMTG resulted in a 35% higher activity level in PC-3 tumor for 177Lu-AMTG than for 177Lu-RM2 at 24 h after injection (Fig. 4). Both 177Lu-AMTG and 177Lu-AMTG2 exhibited excellent clearance kinetics and thus low activity levels in nontumor organs, with the highest values obtained for the kidneys (1.2–1.9 %ID/g). Both compounds were cleared mostly intact (Supplemental Fig. 16), a finding that could favor 177Lu-AMTG and 177Lu-AMTG2 over 177Lu-RM2 and 177Lu-NeoBOMB1, as charged metabolites tend to be taken up by and retained in the kidneys. Most importantly, the activity concentration in the blood and in the GRPR-positive pancreas was low for all 177Lu-RM2 analogs at 24 h after injection (<0.01 and <1 %ID/g, respectively), which we considered another prerequisite for successful translation into humans.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

(A) Biodistribution of 177Lu-RM2 (red) and 177Lu-AMTG (green) in selected organs at 24 h after injection in PC-3 tumor–bearing CB17-SCID mice (100 pmol each). Data are %ID/g, mean ± SD (n = 4). (B) Tumor-to-background ratios for selected organs for 177Lu-RM2 (red) and 177Lu-AMTG (green) at 24 h after injection in PC-3 tumor–bearing CB17-SCID mice. Data are mean ± SD (n = 4).

In contrast, 177Lu-NeoBOMB1 displayed enhanced activity in most nontumor organs and thus the lowest tumor-to-background ratios in most organs, especially in blood, liver, spleen, pancreas, and adrenals, a finding that was also observed by other groups (19,25). The biodistribution profiles confirmed our concerns about increased lipophilicity and internalization rates. It might be speculated that retention in the GRPR-positive pancreas could be caused by a partial agonistic behavior observed in our internalization study, since GRPR agonists such as PESIN or AMBA that exhibit internalization rates of more than 25% at 1 h in vitro typically show a slow clearance from the pancreas over time (28,29).

Although reduced internalization might have other causes, the high structural similarity of 177Lu-AMTG/177Lu-AMTG2 to the known GRPR antagonist 177Lu-RM2 and the comparably low internalization pattern observed in our studies are strong indicators of antagonistic behavior by these new compounds. This assumption is further corroborated by rapid pancreatic clearance within 24 h after injection and the resulting favorable biodistribution profiles. Evidence was also provided by small-animal SPECT/CT scans with 177Lu-RM2 and 177Lu-AMTG over time, both of which showed high tumor retention and fast clearance from nontumor organs, even the GRPR-positive pancreas. It is noteworthy that clearance from pancreas and tumor was less rapid for 177Lu-AMTG, confirming our hypothesis on increased metabolic stability in vivo generated by a simple modification at the Trp8 site. Thus, it is not surprising that tumor-to-background ratios for 177Lu-AMTG were highest in all organs, except for the tumor-to-muscle ratio (Fig. 5).

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

Graphic comparison of tumor-to-background ratios for selected organs for 177Lu-RM2 (red), 177Lu-NeoBOMB1 (gray), 177Lu-AMTG (green), and 177Lu-AMTG (blue). Biodistribution studies were performed at 24 h after injection in PC-3 tumor–bearing CB17-SCID mice. Data are mean ± SD (n = 4).

Regarding dose-limiting organs in the context of radioligand therapy, the excellent tumor-to-kidney and tumor-to-blood ratios make 177Lu-AMTG a highly attractive alternative to 177Lu-RM2 (30). In fact, 177Lu-AMTG seems to synergistically combine the advantages of 177Lu-RM2 and 177Lu-NeoBOMB1 regarding pharmacokinetics and stability while simultaneous offering the best GRPR affinity, both on PC-3 cells and on T-47D cells. Thus, a clinical assessment (e.g., clinical phase I study) with 177Lu-AMTG seems warranted.

In summary, we were able to successfully introduce an α-Me-l-Trp–for–l-Trp8 substitution within the pharmacophore of 177Lu-RM2 that not only resulted in a new tracer (177Lu-AMTG) with comparable affinity, internalization, and lipophilicity but also resulted in considerably improved metabolic stability. Hence, improved tumor uptake and pharmacokinetics superior to those of the parent peptide, 177Lu-RM2, or the second reference compound, 177Lu-NeoBOMB1, were observed for 177Lu-AMTG. A noteworthy finding is that improved metabolic stability was achieved without coadministration of peptidase inhibitors (21), such as phosphoramidon; this finding could facilitate clinical translation. It seems legitimate to conclude that other bombesin derivatives published in recent years, which have been modified at the N or C terminus but not at the unstable dipeptide sequence Gln7-Trp8 (20–22), would also benefit from an α-Me-l-Trp–for–l-Trp8 substitution. Nevertheless, studies on prostate and breast cancer patients have to be performed to show whether these promising preclinical results are reflected on a clinical level.

CONCLUSION

We could demonstrate that the new 177Lu-RM2 derivative 177Lu-AMTG offers better overall preclinical performance than 177Lu-RM2 or 177Lu-NeoBOMB1. On the basis of these results, a clinical translation of 177Lu-AMTG is highly recommended to assess a potential improved therapeutic value for radioligand therapy of GRPR-expressing malignancies, such as prostate and breast cancer. In addition, we expect that substitution of L-amino acids by their corresponding α-alkyl-l-amino acid analogs could also be a valuable approach to stabilize the pharmacophore of other peptidic ligands that suffer from insufficient stability in vivo.

DISCLOSURE

A patent application has been filed on modified GRPR-targeted ligands, including AMTG, with Thomas Günther and Hans-Jürgen Wester as inventors. Parts of this study were funded by the SFB 824 (DFG Sonderforschungsbereich 824, project Z [Hans-Jürgen Wester]) from the Deutsche Forschungsgemeinschaft, Bonn, Germany. Hans-Jürgen Wester is founder and shareholder of Scintomics GmbH, Munich, Germany. No other potential conflict of interest relevant to this article was reported.

KEY POINTS

QUESTION: Is it possible to overcome the major limitation of 177Lu-RM2, its metabolic instability, with regard to future GRPR-targeted radioligand therapy by means of a tiny modification without negatively influencing overall pharmacokinetics?

PERTINENT FINDINGS: Substitution of l-Trp8 by α-Me-l-Trp8 in the pharmacophoric sequence of 177Lu-RM2 retains the favorable tracer pharmacokinetics while enhancing metabolic stability, making 177Lu-AMTG a highly promising novel GRPR-targeted radiopharmaceutical for radioligand therapy.

IMPLICATIONS FOR PATIENT CARE: Although the clinical value of 177Lu-AMTG has to be determined in clinical studies, this study could open new possibilities for complementary treatment of prostate and breast cancer.

ACKNOWLEDGMENTS

We thank Sandra te Heesen for her help with the evaluation of our compounds on T-47D cells, and we thank Daniel Di Carlo and Leon Stopper for their help with the graphics.

Footnotes

  • Published online Jan. 13, 2022.

  • © 2022 by the Society of Nuclear Medicine and Molecular Imaging.

Immediate Open Access: Creative Commons Attribution 4.0 International License (CC BY) allows users to share and adapt with attribution, excluding materials credited to previous publications. License: https://creativecommons.org/licenses/by/4.0/. Details: http://jnm.snmjournals.org/site/misc/permission.xhtml.

REFERENCES

  1. 1.↵
    1. Maqsood MH,
    2. Tameez Ud Din A,
    3. Khan AH
    . Neuroendocrine tumor therapy with lutetium-177: a literature review. Cureus. 2019;11:e3986.
    OpenUrl
  2. 2.↵
    1. Rahbar K,
    2. Afshar-Oromieh A,
    3. Jadvar H,
    4. Ahmadzadehfar H
    . PSMA theranostics: current status and future directions. Mol Imaging. 2018;17:1536012118776068.
    OpenUrl
  3. 3.↵
    1. Reubi JC,
    2. Wenger S,
    3. Schmuckli-Maurer J,
    4. Schaer JC,
    5. Gugger M
    . Bombesin receptor subtypes in human cancers: detection with the universal radioligand 125I-[D-TYR6, beta-ALA11, PHE13, NLE14] bombesin(6-14). Clin Cancer Res. 2002;8:1139–1146.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    1. Reubi C,
    2. Gugger M,
    3. Waser B
    . Co-expressed peptide receptors in breast cancer as a molecular basis for in vivo multireceptor tumour targeting. Eur J Nucl Med Mol Imaging. 2002;29:855–862.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Baratto L,
    2. Song H,
    3. Duan H,
    4. et al
    . PSMA- and GRPR-targeted PET: results from 50 patients with biochemically recurrent prostate cancer. J Nucl Med. 2021;62:1545–1549.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    1. Dalm SU,
    2. Sieuwerts AM,
    3. Look MP,
    4. et al
    . Clinical relevance of targeting the gastrin-releasing peptide receptor, somatostatin receptor 2, or chemokine C-X-C motif receptor 4 in breast cancer for imaging and therapy. J Nucl Med. 2015;56:1487–1493.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. Morgat C,
    2. MacGrogan G,
    3. Brouste V,
    4. et al
    . Expression of gastrin-releasing peptide receptor in breast cancer and its association with pathologic, biologic, and clinical parameters: a study of 1,432 primary tumors. J Nucl Med. 2017;58:1401–1407.
    OpenUrlAbstract/FREE Full Text
  8. 8.↵
    1. Zang J,
    2. Mao F,
    3. Wang H,
    4. et al
    . 68Ga-NOTA-RM26 PET/CT in the evaluation of breast cancer: a pilot prospective study. Clin Nucl Med. 2018;43:663–669.
    OpenUrl
  9. 9.↵
    1. Stoykow C,
    2. Erbes T,
    3. Maecke HR,
    4. et al
    . Gastrin-releasing peptide receptor imaging in breast cancer using the receptor antagonist 68Ga-RM2 and PET. Theranostics. 2016;6:1641–1650.
    OpenUrl
  10. 10.↵
    68-Ga-RM2 PET/MRI in imaging patients with estrogen receptor-positive breast cancer. https://ClinicalTrials.gov/show/NCT03831711. ClinicalTrials.gov website. Published February 6, 2019. Updated December 13, 2021. Accessed June 9, 2022.
  11. 11.
    68Ga-RM2 PET/CT in detecting regional nodal and distant metastases in patients with intermediate or high-risk prostate cancer. ClinicalTrials.gov website. https://ClinicalTrials.gov/show/NCT03113617. Published April 13, 2017. Updated December 7, 2020. Accessed June 9, 2022.
  12. 12.
    68Ga-RM2 PET/MRI in biochemically recurrent prostate cancer. ClinicalTrials.gov website. https://ClinicalTrials.gov/show/NCT02624518. Published December 8, 2015. Updated May 3, 2022. Accessed June 9, 2022.
  13. 13.↵
    177Lu-NeoB in patients with advanced solid tumors and with 68Ga-NeoB lesion uptake. ClinicalTrials.gov website. https://ClinicalTrials.gov/show/NCT03872778. Published March 13, 2019. Updated February 3, 2022. Accessed June 9, 2022.
  14. 14.↵
    1. Kurth J,
    2. Krause BJ,
    3. Schwarzenböck SM,
    4. Bergner C,
    5. Hakenberg OW,
    6. Heuschkel M
    . First-in-human dosimetry of gastrin-releasing peptide receptor antagonist [177Lu]Lu-RM2: a radiopharmaceutical for the treatment of metastatic castration-resistant prostate cancer. Eur J Nucl Med Mol Imaging. 2020;47:123–135.
    OpenUrl
  15. 15.↵
    1. Shipp MA,
    2. Tarr GE,
    3. Chen CY,
    4. et al
    . CD10/neutral endopeptidase 24.11 hydrolyzes bombesin-like peptides and regulates the growth of small cell carcinomas of the lung. Proc Natl Acad Sci USA. 1991;88:10662–10666.
    OpenUrlAbstract/FREE Full Text
  16. 16.↵
    1. Linder KE,
    2. Metcalfe E,
    3. Arunachalam T,
    4. et al
    . In vitro and in vivo metabolism of Lu-AMBA, a GRP-receptor binding compound, and the synthesis and characterization of its metabolites. Bioconjug Chem. 2009;20:1171–1178.
    OpenUrlCrossRefPubMed
  17. 17.↵
    1. Roivainen A,
    2. Kahkonen E,
    3. Luoto P,
    4. et al
    . Plasma pharmacokinetics, whole-body distribution, metabolism, and radiation dosimetry of 68Ga bombesin antagonist BAY 86-7548 in healthy men. J Nucl Med. 2013;54:867–872.
    OpenUrlAbstract/FREE Full Text
  18. 18.↵
    1. Mansi R,
    2. Wang X,
    3. Forrer F,
    4. et al
    . Development of a potent DOTA-conjugated bombesin antagonist for targeting GRPr-positive tumours. Eur J Nucl Med Mol Imaging. 2011;38:97–107.
    OpenUrlCrossRefPubMed
  19. 19.↵
    1. Kaloudi A,
    2. Lymperis E,
    3. Giarika A,
    4. et al
    . NeoBOMB1, a GRPR-antagonist for breast cancer theragnostics: first results of a preclinical study with [67Ga]NeoBOMB1 in T-47D cells and tumor-bearing mice. Molecules. 2017;22:1950.
  20. 20.↵
    1. Lau J,
    2. Rousseau E,
    3. Zhang Z,
    4. et al
    . Positron emission tomography imaging of the gastrin-releasing peptide receptor with a novel bombesin analogue. ACS Omega. 2019;4:1470–1478.
    OpenUrl
  21. 21.↵
    1. Bakker IL,
    2. van Tiel ST,
    3. Haeck J,
    4. et al
    . In vivo stabilized SB3, an attractive GRPR antagonist, for pre- and intra-operative imaging for prostate cancer. Mol Imaging Biol. 2018;20:973–983.
    OpenUrl
  22. 22.↵
    1. Mitran B,
    2. Thisgaard H,
    3. Rosenstrom U,
    4. et al
    . High contrast PET imaging of GRPR expression in prostate cancer using cobalt-labeled bombesin antagonist RM26. Contrast Media Mol Imaging. 2017;2017:6873684.
    OpenUrl
  23. 23.↵
    1. Weineisen M,
    2. Simecek J,
    3. Schottelius M,
    4. Schwaiger M,
    5. Wester HJ
    . Synthesis and preclinical evaluation of DOTAGA-conjugated PSMA ligands for functional imaging and endoradiotherapy of prostate cancer. EJNMMI Res. 2014;4:63.
    OpenUrlCrossRefPubMed
  24. 24.↵
    1. Nakagawa T,
    2. Hocart SJ,
    3. Schumann M,
    4. et al
    . Identification of key amino acids in the gastrin-releasing peptide receptor (GRPR) responsible for high affinity binding of gastrin-releasing peptide (GRP). Biochem Pharmacol. 2005;69:579–593.
    OpenUrlCrossRefPubMed
  25. 25.↵
    1. Dalm SU,
    2. Bakker IL,
    3. de Blois E,
    4. et al
    . 68Ga/177Lu-NeoBOMB1, a novel radiolabeled GRPR antagonist for theranostic use in oncology. J Nucl Med. 2017;58:293–299.
    OpenUrlAbstract/FREE Full Text
  26. 26.↵
    1. Varasteh Z,
    2. Mitran B,
    3. Rosenstrom U,
    4. et al
    . The effect of macrocyclic chelators on the targeting properties of the 68Ga-labeled gastrin releasing peptide receptor antagonist PEG2-RM26. Nucl Med Biol. 2015;42:446–454.
    OpenUrl
  27. 27.↵
    1. Popp I,
    2. Del Pozzo L,
    3. Waser B,
    4. et al
    . Approaches to improve metabolic stability of a statine-based GRP receptor antagonist. Nucl Med Biol. 2017;45:22–29.
    OpenUrl
  28. 28.↵
    1. Mansi R,
    2. Wang X,
    3. Forrer F,
    4. et al
    . Evaluation of a 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid-conjugated bombesin-based radioantagonist for the labeling with single-photon emission computed tomography, positron emission tomography, and therapeutic radionuclides. Clin Cancer Res. 2009;15:5240–5249.
    OpenUrlAbstract/FREE Full Text
  29. 29.↵
    1. Zhang H,
    2. Schuhmacher J,
    3. Waser B,
    4. et al
    . DOTA-PESIN, a DOTA-conjugated bombesin derivative designed for the imaging and targeted radionuclide treatment of bombesin receptor-positive tumours. Eur J Nucl Med Mol Imaging. 2007;34:1198–1208.
    OpenUrlCrossRefPubMed
  30. 30.↵
    1. Coleman CN,
    2. Blakely WF,
    3. Fike JR,
    4. et al
    . Molecular and cellular biology of moderate-dose (1-10 Gy) radiation and potential mechanisms of radiation protection: report of a workshop at Bethesda, Maryland, December 17-18, 2001. Radiat Res. 2003;159:812–834.
    OpenUrlCrossRefPubMed
  • Received for publication October 4, 2021.
  • Revision received December 28, 2021.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 63 (9)
Journal of Nuclear Medicine
Vol. 63, Issue 9
September 1, 2022
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Substitution of l-Tryptophan by α-Methyl-l-Tryptophan in 177Lu-RM2 Results in 177Lu-AMTG, a High-Affinity Gastrin-Releasing Peptide Receptor Ligand with Improved In Vivo Stability
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Substitution of l-Tryptophan by α-Methyl-l-Tryptophan in 177Lu-RM2 Results in 177Lu-AMTG, a High-Affinity Gastrin-Releasing Peptide Receptor Ligand with Improved In Vivo Stability
Thomas Günther, Sandra Deiser, Veronika Felber, Roswitha Beck, Hans-Jürgen Wester
Journal of Nuclear Medicine Sep 2022, 63 (9) 1364-1370; DOI: 10.2967/jnumed.121.263323

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Substitution of l-Tryptophan by α-Methyl-l-Tryptophan in 177Lu-RM2 Results in 177Lu-AMTG, a High-Affinity Gastrin-Releasing Peptide Receptor Ligand with Improved In Vivo Stability
Thomas Günther, Sandra Deiser, Veronika Felber, Roswitha Beck, Hans-Jürgen Wester
Journal of Nuclear Medicine Sep 2022, 63 (9) 1364-1370; DOI: 10.2967/jnumed.121.263323
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • ACKNOWLEDGMENTS
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • First-in-Human Serum Stability Studies of [177Lu]Lu-AMTG: A Step Toward Improved GRPR-Targeted Radiopharmaceutical Therapy
  • Preclinical Evaluation of Gastrin-Releasing Peptide Receptor Antagonists Labeled with 161Tb and 177Lu: A Comparative Study
  • Preclinical Evaluation of Minigastrin Analogs and Proof-of-Concept [68Ga]Ga-DOTA-CCK-66 PET/CT in 2 Patients with Medullary Thyroid Cancer
  • Preclinical Comparison of the 64Cu- and 68Ga-Labeled GRPR-Targeted Compounds RM2 and AMTG, as Well as First-in-Humans [68Ga]Ga-AMTG PET/CT
  • Google Scholar

More in this TOC Section

  • RadioFlow Cytometry Reveals That [18F]FDG Uptake in K-RAS Lung Cancer Is Driven by Immune Cells: An Analysis on a Single-Cell Level
  • Comparison Between Brain and Cerebellar Autoradiography Using [18F]Flortaucipir, [18F]MK6240, and [18F]PI2620 in Postmortem Human Brain Tissue
  • Preclinical Evaluation of 226Ac as a Theranostic Agent: Imaging, Dosimetry, and Therapy
Show more FEATURED BASIC SCIENCE ARTICLE

Similar Articles

Keywords

  • AMTG
  • GRPR
  • RM2
  • prostate cancer
  • increased metabolic stability
  • NeoBOMB1
SNMMI

© 2025 SNMMI

Powered by HighWire