Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleFeatured Article of The Month
Open Access

68Ga-NODAGA-Exendin-4 PET/CT Improves the Detection of Focal Congenital Hyperinsulinism

Marti Boss, Christof Rottenburger, Winfried Brenner, Oliver Blankenstein, Vikas Prasad, Sonal Prasad, Paolo de Coppi, Peter Kühnen, Mijke Buitinga, Pirjo Nuutila, Timo Otonkoski, Khalid Hussain, Maarten Brom, Annemarie Eek, Jamshed Bomanji, Pratik Shah and Martin Gotthardt
Journal of Nuclear Medicine February 2022, 63 (2) 310-315; DOI: https://doi.org/10.2967/jnumed.121.262327
Marti Boss
1Department of Medical Imaging, Radboud University Medical Centre, Nijmegen, The Netherlands;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Christof Rottenburger
2Division of Nuclear Medicine, University Hospital Basel, Basel, Switzerland;
3Institute of Nuclear Medicine, University College London, London, United Kingdom;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Winfried Brenner
3Institute of Nuclear Medicine, University College London, London, United Kingdom;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Oliver Blankenstein
4Department of Nuclear Medicine, Charité–Universitätsmedizin, Berlin, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Vikas Prasad
3Institute of Nuclear Medicine, University College London, London, United Kingdom;
5Institute for Experimental Pediatric Endocrinology, Charité–Universitätsmedizin, Berlin, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sonal Prasad
3Institute of Nuclear Medicine, University College London, London, United Kingdom;
6Department of Nuclear Medicine, University Hospital of Ulm, Ulm, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Paolo de Coppi
7Berlin Experimental Radionuclide Imaging Center, Charité–Universitätsmedizin, Berlin, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Peter Kühnen
4Department of Nuclear Medicine, Charité–Universitätsmedizin, Berlin, Germany;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mijke Buitinga
1Department of Medical Imaging, Radboud University Medical Centre, Nijmegen, The Netherlands;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pirjo Nuutila
8Department of Pediatric Surgery, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, United Kingdom;
9Department of Endocrinology, Turku University Hospital, Turku, Finland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Timo Otonkoski
10Turku PET Center, University of Turku, Turku, Finland;
11Stem Cells and Metabolism Research Program, Faculty of Medicine, University of Helsinki, Helsinki, Finland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Khalid Hussain
12Children’s Hospital, University of Helsinki and Helsinki University Hospital, Helsinki, Finland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Maarten Brom
1Department of Medical Imaging, Radboud University Medical Centre, Nijmegen, The Netherlands;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Annemarie Eek
1Department of Medical Imaging, Radboud University Medical Centre, Nijmegen, The Netherlands;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jamshed Bomanji
2Division of Nuclear Medicine, University Hospital Basel, Basel, Switzerland;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pratik Shah
13Department of Pediatric Medicine, Division of Endocrinology, Sidra Medical and Research Center, Doha, Qatar;
14Pediatric Endocrinology Department, Great Ormond Street Hospital for Children, NHS Foundation Trust, London, United Kingdom; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Martin Gotthardt
1Department of Medical Imaging, Radboud University Medical Centre, Nijmegen, The Netherlands;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

Surgery with curative intent can be offered to congenital hyperinsulinism (CHI) patients, provided that the lesion is focal. Radiolabeled exendin-4 specifically binds the glucagonlike peptide 1 receptor on pancreatic β-cells. In this study, we compared the performance of 18F-DOPA PET/CT, the current standard imaging method for CHI, and PET/CT with the new tracer 68Ga-NODAGA-exendin-4 in the preoperative detection of focal CHI. Methods: Nineteen CHI patients underwent both 18F-DOPA PET/CT and 68Ga-NODAGA-exendin-4 PET/CT before surgery. The images were evaluated in 3 settings: a standard clinical reading, a masked expert reading, and a joint reading. The target (lesion)-to-nontarget (normal pancreas) ratio was determined using SUVmax. Image quality was rated by pediatric surgeons in a questionnaire. Results: Fourteen of 19 patients having focal lesions underwent surgery. On the basis of clinical readings, the sensitivity of 68Ga-NODAGA-exendin-4 PET/CT (100%; 95% CI, 77%–100%) was higher than that of 18F-DOPA PET/CT (71%; 95% CI, 42%–92%). Interobserver agreement between readings was higher for 68Ga-NODAGA-exendin-4 than for 18F-DOPA PET/CT (Fleiss κ = 0.91 vs. 0.56). 68Ga-NODAGA-exendin-4 PET/CT provided significantly (P = 0.021) higher target-to-nontarget ratios (2.02 ± 0.65) than did 18F-DOPA PET/CT (1.40 ± 0.40). On a 5-point scale, pediatric surgeons rated 68Ga-NODAGA-exendin-4 PET/CT as superior to 18F-DOPA PET/CT. Conclusion: For the detection of focal CHI, 68Ga-NODAGA-exendin-4 PET/CT has higher clinical sensitivity and better interobserver correlation than 18F-DOPA PET/CT. Better contrast and image quality make 68Ga-NODAGA-exendin-4 PET/CT superior to 18F-DOPA PET/CT in surgeons’ intraoperative quest for lesion localization.

  • congenital hyperinsulinism
  • focal CHI
  • diagnostic imaging
  • 68Ga-NODAGA-exendin-4 PET/CT
  • 18F-DOPA PET/CT

Congenital hyperinsulinism (CHI) is the most common cause of persistent and recurrent hypoglycemia in neonates. It occurs with an incidence of 1 in 35,000–40,000 births (1). CHI often presents in neonates as poor feeding, seizures, jitteriness, hypotonia, apnea, cyanosis, hypothermia, or a hypoglycemia-induced life-threatening event (2). CHI can also manifest in infancy or childhood and, in rare cases, even in adolescents or young adults (3). To avoid brain injury, early diagnosis and proper treatment of CHI are crucial. The diagnosis of CHI is based on clinical findings and hypoglycemic events, combined with inappropriately high insulin or C-peptide levels or low insulinlike growth factor– binding protein 1 levels (4,5). In diffuse CHI, which accounts for 60%–70% of all cases, there is diffuse involvement of the pancreatic β-cells, with enlarged hyperfunctioning cells that have abnormally large nuclei and abundant cytoplasm (6,7). This subform is caused by recessive or dominant mutations in the ABCC8 or KCNJ11 genes, encoding for the β-cell adenosine triphosphate– sensitive potassium channels. Diffuse CHI is treated primarily with medication, such as octreotide and diazoxide. However, many patients with recessive mutations in the ABCC8 and KCNJ11 genes are unresponsive to this therapy, and near-total pancreatectomy may then be the only option to avoid devastating hypoglycemia. Even after such an invasive procedure, some children present with recurring hypoglycemia, requiring further treatment with medication or even reoperation (8).

Focal CHI accounts for 30%–40% of all CHI cases associated with the adenosine triphosphate–sensitive potassium channel genes. This form is characterized by focal adenomatous islet cell hyperplasia caused by the concurrence of a paternal mutation in the ABCC8 or KCNJ11 gene and somatic loss of heterozygosity of the maternal chromosome 11p15 region within a limited pancreatic region (9,10). Because there is involvement of only a specific pancreatic area, focal CHI can be treated successfully by partial pancreatectomy or limited lesionectomy, which can cure the disease in cases of complete removal of the lesion (7). Since focal CHI can be treated with much less invasive surgery than diffuse CHI, correct differentiation between these subforms is of great importance. Also, precise presurgical localization of the focal lesion is important for correct surgical planning and optimization of surgical outcomes. If the lesion resides in the body or tail of the pancreas, a minimally invasive, laparoscopic, procedure may be performed (11).

The current standard imaging technique for noninvasive detection of focal CHI is 18F-DOPA PET/CT (12). Because this technique has a sensitivity of only 85%–89% for the detection of focal CHI (13), focal lesions are still missed in some cases. In this study, we used a new radiotracer based on the peptide exendin-4, which binds with high affinity specifically to the glucagonlike peptide 1 receptor expressed on pancreatic β-cells (14). 68Ga-labeled exendin has been shown to detect insulinomas with high sensitivity (15,16). The specific tracer used in the current study, 68Ga-NODAGA-exendin-4, is being assessed in a large prospective trial for insulinoma imaging (NCT03189953). We have analyzed the data of patients with CHI who underwent both 18F-DOPA PET/CT and 68Ga-NODAGA-exendin-4 PET/CT to compare the effectiveness of these 2 imaging techniques for the detection and localization of focal CHI.

MATERIALS AND METHODS

Study Design and Patients

This prospective multicenter study (NCT03768518) included consecutive eligible patients at the Great Ormond Street Hospital in the United Kingdom (7 patients) and at the Radboud University Medical Centre in The Netherlands (1 patient). Patients were recruited directly by these centers and by referral from several tertiary centers across Europe.

Patients were enrolled with biochemically proven, endogenous CHI who were unresponsive to medical treatment and qualified for 18F-DOPA PET/CT on the basis of mutation analysis (no genetically proven diffuse CHI based on a homozygous or compound heterozygous ABCC8/KCNJ11 mutation). Exclusion criteria were renal insufficiency (creatinine clearance < 40 mL/min) and evidence of malignancies other than insulin-producing lesions. The study was approved by the local institutional review board of both participating institutes. The parents of all included patients provided written informed consent in accordance with provisions of the Declaration of Helsinki.

In addition, real-world evidence data from CHI patients diagnosed and treated at the Charité University Hospital in Germany (11 patients) were analyzed in accordance with national drug regulations. Parents of these patients provided written informed consent to the use of the new radiotracer.

Procedures

In all patients, 18F-DOPA PET/CT was performed according to the local guidelines for focal-CHI detection. 18F-DOPA (3 MBq/kg; lower limit, 40 MBq) was injected as a slow bolus over 1 min. Patients had not fasted and were not pretreated with carbidopa. A PET/CT acquisition at 1 bed position for 10 min was started 20 min after tracer injection. Depending on the assessment of the first scan, additional PET acquisitions were performed at 40 or 60 min after tracer injection.

For 68Ga-NODAGA-exendin-4 PET/CT, a 1.6 ± 0.1 MBq/kg dose of the tracer (lower limit, 20 MBq), corresponding to a peptide dose of maximally 0.08–0.12 µg/kg (lower limit, 1.4 µg), was injected intravenously as a slow bolus over 5 min. Details on radiopharmaceutical preparation are provided in the supplemental materials. The patients had fasted for 1 h before tracer injection to reduce endogenous glucagonlike peptide 1 production. Blood glucose levels were monitored before tracer injection and at least at 5, 10, 15, 30, 60, 90, and 120 min after tracer injection. Since blood glucose levels may decrease after 68Ga-NODAGA-exendin-4 injection, they were closely monitored. Intravenous glucose injection with a case-specific infusion rate was given to all patients to manage glucose levels during the procedure.

PET acquisition methods varied because of differences in the institutional standard of care for CHI patients. Details on 68Ga-NODAGA-exendin-4 PET/CT and PET/MRI acquisition procedures for all centers and reconstruction parameters are given in Supplemental Table 1 (supplemental materials are available at http://jnm.snmjournals.org). At the Great Ormond Street Hospital, a protocol has been developed for 18F-DOPA PET/CT/CT to be performed under oral sedation with chloral hydrate in children with CHI to avoid general anesthesia (Sarah Kiff et al., unpublished data, 2021). This protocol was adopted for 68Ga-NODAGA-exendin-4 PET/CT acquisitions at the Great Ormond Street Hospital.

At the Radboud University Medical Centre, 1 patient was included. Scans there were performed without anesthesia with a vacuum mattress.

Real-world evidence from an institutional database of 11 CHI patients who underwent 68Ga-NODAGA-exendin-4 PET/CT for diagnostic purposes at the Charité University Hospital were included retrospectively. Younger children were imaged while receiving inhalation anesthesia with isoflurane under the supervision of an anesthesiologist; older children were able to undergo the procedure without sedation.

Evaluation

Histologic evaluation and clinical outcome (normalization of blood glucose levels after surgery) were used as a reference standard. 18F-DOPA PET/CT and 68Ga-NODAGA-exendin-4 PET/CT scans were clinically read at the site of patient inclusion by nonmasked observers. The clinical reading was performed by a pediatric endocrinologist (hyperinsulinism expert) together with a nuclear medicine physician and a pediatric surgeon at the site of the PET scan. After completion of data collection, all 18F-DOPA and 68Ga-NODAGA-exendin-4 PET/CT images were reevaluated by 1 masked 68Ga-NODAGA-exendin-4–experienced nuclear medicine physician (expert reading). Additionally, a joint reevaluation of all images was performed by this nuclear medicine physician together with a pediatric endocrinologist highly experienced in 18F-DOPA PET/CT reading. All images were evaluated in terms of disease subform and, if detected, the size and location of the focal lesion. For exact localization of the focal lesion, the pancreas was divided into 6 areas based on anatomic relation to the pancreatic duct and portal vein (Supplemental Fig. 1). Images from all time points were used for interpretation.

Quantitative analysis of the 18F-DOPA PET/CT and 68Ga-NODAGA-exendin-4 PET/CT or PET/MRI scans in which focal lesions had been confirmed by histopathology was performed by a nonmasked expert. Volumes of interest (VOIs) were drawn to determine tracer uptake, expressed as SUVmax, in different parts of the pancreas and visible focal lesions. The SUVmax ratios of the focal lesion or area with the highest tracer uptake (for 18F-DOPA PET/CT scans in which the focal lesion was not detected) and the area with the next highest tracer uptake were determined. VOIs were drawn over the head, body, and tail of the pancreas. Within these VOIs, isocontour VOIs were created consisting of the voxels with the 30% highest intensity (examples of resulting VOIs are depicted in Supplemental Fig. 2). For quantification of the dynamic PET scans, reconstructed images of the time frames from 30 to 40 min (Charité University Hospital) and from 40 to 45 min (University College London) after injection were used.

To estimate the optimal imaging time point for 68Ga-NODAGA-exendin-4 PET/CT, SUVmax ratios in reconstructed images of 5-min intervals over the imaging period from 0 to 45 min after tracer injection were determined in 4 patients with focal disease.

To evaluate image quality and correlation of imaging results with the intraoperative findings, 18F-DOPA PET/CT and 68Ga-NODAGA-exendin-4 PET/CT images of 13 patients with a detected focal lesion were rated by the involved pediatric surgeon using a questionnaire based on the Leiden surgical rating scale (supplemental materials).

Statistical Analysis

Imaging results confirmed by histopathology were regarded as true-positives or true-negatives. Imaging results with competing histopathology results were regarded as false-positives or false-negatives. Ninety-five percent CIs for sensitivity were calculated using the Clopper–Pearson method. Interobserver variation was calculated using the Fleiss κ. SUVmax ratios in 18F-DOPA PET/CT and 68Ga-NODAGA-exendin-4 PET/CT scans were compared using paired-sample t tests. Surgeon scores of image quality were compared using Wilcoxon signed-rank tests. Statistical analyses were performed using SPSS (version 22; IBM).

RESULTS

Patients

We included the data of 19 CHI patients. Baseline characteristics of the patients are given in Table 1, and clinical details are in Supplemental Table 2. All patients underwent 18F-DOPA PET/CT and 68Ga-NODAGA-exendin-4 PET/CT, with a median time of 13 d (range, 4–72 d) between the procedures. On clinical reading, 18F-DOPA PET/CT revealed focal areas of high tracer uptake suggestive of focal lesions in 10 patients (53%), and 68Ga-NODAGA-exendin-4 PET/CT revealed such areas in 14 patients (74%) (Table 2). The study profile is depicted in Supplemental Figure 3.

View this table:
  • View inline
  • View popup
TABLE 1

Patient Characteristics

View this table:
  • View inline
  • View popup
TABLE 2

Sensitivity of 18F-DOPA PET/CT and 68Ga-NODAGA-Exendin-4 PET/CT Based on Clinical and Study Readings

Tolerability

One patient (5%) experienced vomiting after injection of 68Ga-NODAGA-exendin-4. In 2 patients (11%), episodes of mild hypoglycemia requiring increased glucose infusion occurred after injection of 68Ga-NODAGA-exendin-4. In the other patients, glucose levels were stable (>3.5 mmol/L) under regular monitoring and intravenous glucose infusion. No other adverse events occurred in any of the patients.

Surgery

The results of both imaging procedures were used for surgical planning. Suggestive lesions were detected by clinical reading of the PET images in 14 patients. These patients underwent surgery, and the presence of focal lesions was confirmed by histopathologic evaluation. All surgically treated patients with focal lesions were cured after surgery (normalization of blood glucose levels in long-term follow-up).

Of the remaining 5 patients, in whom no focal lesion was detected by clinical reading (diffuse tracer uptake on both 18F-DOPA and 68Ga-NODAGA-exendin-4 PET/CT), 1 patient underwent near-total pancreatectomy because of an insufficient response to medication. In line with the imaging results, histopathology indicated diffuse disease in this patient. The 4 patients who did not undergo surgery (aged 10, 18, 68, and 125 mo) could be sufficiently managed with diet and medication.

Since histopathology and clinical follow-up were the reference standard, patients who did not undergo surgery were excluded from analysis.

Diagnostic Performance

Imaging results are summarized in Table 2. In this patient population, 68Ga-NODAGA-exendin-4 PET/CT had a sensitivity of 100% (95% CI, 77%–100%) for detection of focal lesions, compared with a sensitivity of 71% (95% CI, 42%–92%) for 18F-DOPA PET/CT, based on clinical readings of the images. In 4 of 15 patients (27%), focal lesions were identified only using 68Ga-NODAGA-exendin-4 PET/CT. In these patients, the surgery planning was based solely on the results of the 68Ga-NODAGA-exendin-4 PET/CT. 18F-DOPA PET/CT and 68Ga-NODAGA-exendin-4 PET/CT images of these 4 patients are shown in Figure 1. On the basis of the clinical readings, 68Ga-NODAGA-exendin-4 PET/CT performed better for detection of focal lesions.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

68Ga-NODAGA-exendin-4 PET/CT and 18F-DOPA PET/CT images of patients 2 (A), 4 (B), 6 (C), and 9 (D), for whom 68Ga-NODAGA-exendin-4 PET/CT scans were reported as focal in clinical readings whereas 18F-DOPA PET/CT scans were reported as diffuse. Locations of focal lesions (for 18F-DOPA PET/CT detected during joint readings) are indicated with green arrows. In D, focal lesion in head is indicated with green arrows, and for comparison, red arrows indicate areas with the next highest tracer uptake in all images. Presence of focal lesions was confirmed by histopathology in all 4 patients.

Interobserver Correlation

On reevaluation of the 18F-DOPA PET/CT images by an expert nuclear medicine physician, 2 additional focal lesions were identified, increasing the sensitivity to 86% (range, 57%–98%). In the expert readings of the 68Ga-NODAGA-exendin-4 PET/CT images, 1 focal lesion was missed, decreasing the sensitivity to 93% (range, 66%–100%). Through joint reading of the images by an expert nuclear medicine physician and a pediatric endocrinologist, all focal lesions were detected on both 68Ga-NODAGA-exendin-4 PET/CT and 18F-DOPA PET/CT. Although the sensitivity of both techniques reached 100%, the interobserver agreement was higher for 68Ga-NODAGA-exendin-4 PET/CT than for 18F-DOPA PET/CT (Fleiss κ = 0.91 vs. 0.56). For 68Ga-NODAGA-exendin-4 PET/CT, there was almost perfect agreement, whereas for 18F-DOPA PET/CT, the level of agreement between the readings was only moderate. The increased sensitivity of 18F-DOPA PET/CT on only reevaluation of the images, together with the higher interobserver agreement in evaluation of the 68Ga-NODAGA-exendin-4 PET/CT images, clearly indicates a facilitated and more reliable interpretation of the 68Ga-NODAGA-exendin-4 PET/CT images, resulting in less equivocal results.

Semiquantitative Analysis

In patients with histopathologically proven focal CHI, the SUVmax ratios of the focal lesion to the area of the pancreas with the next highest tracer uptake are significantly higher in 68Ga-NODAGA-exendin-4 PET/CT than in 18F-DOPA PET/CT (2.03 ± 0.63 and 1.03 ± 0.35, respectively; P = 0.0026) (Fig. 2). These quantitative data show that 68Ga-NODAGA-exendin-4 PET/CT provides better contrast to discriminate between focal and diffuse disease and thus explains the difference in interobserver agreement levels.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

(A) SUVmax ratios between focal lesion and area with next highest tracer uptake. Data are given as mean ± SD, as well as individual datapoints. Scans with focal lesions identified during clinical reading are depicted in red. Scans reported to show diffuse disease are depicted in blue. (B and C) Rating scores of 68Ga-NODAGA-exendin-4 and 18F-DOPA PET/CT images by pediatric surgeons. Scores are on preoperative image quality for decision to perform surgery (B) and correlation of imaging results with intraoperative findings (C). *P < 0.05.

Quantification of reconstructed images of 5-min intervals over the imaging period shows some variability between patients in the time point of the highest SUVmax ratio. SUVmax ratios over time are depicted in Supplemental Figure 4. For all 4 patients, the highest SUVmax ratio was between 30 and 45 min after tracer injection. This therefore seems to be the best time frame for 68Ga-NODAGA-exendin-4 PET/CT imaging.

Surgical Ease

The influence of PET image quality on surgical ease was measured by rating of the DOPA and 68Ga-NODAGA-exendin-4 PET/CT images by the involved pediatric surgeons. These were all experienced surgeons who had performed more than 10 CHI surgeries during their career and more than 5 during the last 3 y. The surgeons’ rating of PET image quality showed significantly higher scores for 68Ga-NODAGA-exendin-4 PET/CT than for 18F-DOPA PET/CT regarding the decision to perform surgery (4.5 vs. 3.8, respectively; P = 0.025; Fig. 2B), as well as regarding correlation of the imaging results with intraoperative findings (4.4 vs. 3.7, respectively; P = 0.0083; Fig. 2C). Of 13 cases, the surgeons reported preferring 68Ga-NODAGA-exendin-4 PET/CT imaging for future CHI patients in 9 cases, versus 18F-DOPA PET/CT in only 1 case and no preference in 3 cases. This finding implies a better image quality for 68Ga-NODAGA-exendin-4 PET/CT than for 18F-DOPA PET/CT and a possible benefit for the surgical treatment of CHI patients.

DISCUSSION

The results of the present study indicate that 68Ga-NODAGA-exendin-4 PET/CT is a promising tool for detection and localization of focal CHI, providing a high sensitivity and diagnostic accuracy. The higher interreader agreement of 68Ga-NODAGA-exendin-4 PET/CT than of 18F-DOPA PET/CT indicates superior performance of 68Ga-NODAGA-exendin-4 PET/CT in some patients by providing less equivocal results.

Quantitative analysis of scans of patients with histopathologically confirmed focal CHI showed significantly higher SUVmax ratios on 68Ga-NODAGA-exendin-4 PET/CT than on 18F-DOPA PET/CT. The higher contrast between uptake in the focal lesion and in the remainder of the pancreas on 68Ga-NODAGA-exendin-4 PET/CT scans enables easier detection of focal lesions. This finding explains the increased sensitivity of 68Ga-NODAGA-exendin-4 PET/CT based on the initial clinical reading, and the increased rate of agreement in readings of 68Ga-NODAGA-exendin-4 PET/CT images between clinical and expert readers, in comparison to 18F-DOPA PET/CT images. This increased sensitivity and agreement are of importance, especially in cases with a heterogeneous pattern of tracer uptake in the pancreas—cases that are usually difficult to diagnose (13).

The superior image quality of 68Ga-NODAGA-exendin-4 PET/CT is important for both the scan reading and the surgical procedure, since successful surgery depends on precise presurgical detection of focal CHI and the subsequent discovery and complete removal of the focal lesion intraoperatively, as reflected by pediatric surgeons’ image ratings. 68Ga-NODAGA-exendin-4 PET/CT could benefit the surgical treatment of CHI patients by facilitating the decision to perform surgery, as well as the intraoperative localization of the focal lesion.

In our limited population of 19 CHI patients, 4 cases of focal CHI were clinically not identified using 18F-DOPA PET/CT. This is a high number compared with a previous large prospective study with 50 cases and retrospective reviews of 105 and 195 cases, which reported sensitivities of 88%, 85%, and 89%, respectively, for detection of focal CHI using 18F-DOPA PET/CT (13,17,18). This result is suggestive of a high complexity in the cases in this study. An overrepresentation of such difficult cases in our study population could stem from an increased incentive to refer patients with complex and equivocal 18F-DOPA PET/CT imaging results for an investigative diagnostic procedure. In this population, 68Ga-NODAGA-exendin-4 PET/CT outperformed 18F-DOPA PET/CT in the clinical nonexpert setting, facilitating curative surgery without the need for further medicinal treatment or near-total pancreatectomy in 4 additional patients. 68Ga-NODAGA-exendin-4 PET/CT therefore had a major positive impact on the clinical management of these patients.

A limitation of the current study was the inability to exclude the possibility of missed focal lesions. All focal lesions that were identified by 68Ga-NODAGA-exendin-4 PET/CT were confirmed by histopathology. However, 4 patients in whom diffuse disease was indicated on both 18F-DOPA PET/CT and 68Ga-NODAGA-exendin-4 PET/CT did not undergo surgery but instead received continued medical treatment. In these patients, diffuse disease was not confirmed.

Another possible limitation of this study was the inclusion of patients from 3 centers with differences in the 68Ga-NODAGA-exendin-4 PET/CT acquisition procedure (Supplemental Table 1). However, the high degree of diagnostic accuracy and interreader agreement for 68Ga-NODAGA-exendin-4 PET/CT in all included patients shows the robustness of this technique in clinical practice.

On the basis of the data in this study, the expected optimal time frame for 68Ga-NODAGA-exendin-4 PET/CT imaging is between 30 and 45 min after tracer injection. In the tail of the pancreas, focal lesions that overlap the contour of the left kidney pose a diagnostic challenge with 18F-DOPA PET/CT, as has been described previously (13). Because of the high renal accumulation of 68Ga-NODAGA-exendin-4 PET/CT, this issue also occurs with PET/CT using this tracer. In such cases, performing additional scans at later time points could be beneficial, since uptake of 68Ga-NODAGA-exendin-4 PET/CT in the kidneys was shown to decrease over time in adults (19).

The introduction of 18F-DOPA PET/CT to discriminate between focal and diffuse CHI has had a major impact on the clinical approach by obviating more invasive diagnostic procedures, such as selective arterial calcium stimulation with simultaneous venous sampling or transhepatic portal venous insulin sampling, and by optimizing surgical treatment because of increased diagnostic accuracy. This study showed that 68Ga-NODAGA-exendin-4 PET/CT has the potential to even further improve the treatment of patients with focal CHI by improving diagnostic accuracy and certainty. This improvement could enable curative surgery in more patients and could benefit surgical planning by providing more precise and reliable preoperative images.

In addition to the better image quality of 68Ga-NODAGA-exendin-4 PET/CT than of 18F-DOPA PET/CT, another important advantage to 68Ga-NODAGA-exendin-4 PET/CT is the production of 68Ga by a generator. Because of the short half-life of 68Ga (68 min), it cannot be transported between centers. However, production by a generator enables on-site production of the radiotracer even at PET centers without a cyclotron, thereby enabling broad availability. Since 18F-DOPA is often difficult to obtain, this capability could transform the care of focal-CHI patients at such centers. In addition, the equivocal results provided by 68Ga-NODAGA-exendin-4 PET/CT will also enable correct image interpretation at less experienced centers. An additional important advantage to 68Ga-NODAGA-exendin-4 is the very low PET radiation dose to the patients, which we previously calculated to be about 4-fold lower for newborn patients than the radiation dose from 18F-DOPA (19).

CONCLUSION

Through this study, we provided the first (to our knowledge) clinical evidence of detection and localization of focal CHI using 68Ga-NODAGA-exendin-4 PET/CT. These first results show that image quality is better for 68Ga-NODAGA-exendin-4 PET/CT than for the standard 18F-DOPA PET/CT, resulting in an excellent sensitivity and diagnostic accuracy, which changed the surgical management in 4 of 19 patients. Although the performance of 68Ga-NODAGA-exendin-4 PET/CT needs to be further assessed in a larger patient population, we believe that it has the potential to replace 18F-DOPA PET/CT as the primary imaging tool for detection and localization of focal CHI.

DISCLOSURE

This work was supported by BetaCure (FP7/2014-2018, grant 602812). PET/MRI use at Charité University Hospital was supported by Deutsche Forschungsgemeinschaft (INST 335/543-1 FUGG). Martin Gotthardt is an inventor on, and holder of, the patent “Invention Affecting GLP-1 and Exendin” (Philipps-Universität Marburg, June 17, 2009). Paolo De Coppi is supported by NIHR BRC Great Ormond Street Hospital. No other potential conflict of interest relevant to this article was reported.

KEY POINTS

QUESTION: Is 68Ga-NODAGA-exendin-4 PET/CT effective for preoperative detection and localization of focal CHI?

PERTINENT FINDINGS: 68Ga-NODAGA-exendin-4 PET/CT has higher clinical sensitivity and a better interobserver correlation for the detection of focal CHI than does 18F-DOPA PET/CT. 68Ga-NODAGA-exendin-4 PET/CT provided significantly higher target-to-nontarget ratios than did 18F-DOPA PET/CT, and pediatric surgeons rated 68Ga-NODAGA-exendin-4 PET/CT superior to 18F-DOPA PET/CT.

IMPLICATIONS FOR PATIENT CARE: 68Ga-NODAGA-exendin-4 PET/CT has the potential to benefit the treatment of patients with focal CHI by improving diagnostic accuracy and certainty. This advantage could enable curative surgery in more patients and benefit surgical planning by providing more precise and reliable preoperative images.

ACKNOWLEDGMENTS

We thank all patients and their parents or caretakers for participating in the study. We also thank the technical staff at the Radboud University Medical Centre, Charité University Hospital, and University College London for their support with radiochemical preparations and PET investigations.

Footnotes

  • Published online July 02, 2021.

  • © 2022 by the Society of Nuclear Medicine and Molecular Imaging.

Immediate Open Access: Creative Commons Attribution 4.0 International License (CC BY) allows users to share and adapt with attribution, excluding materials credited to previous publications. License: https://creativecommons.org/licenses/by/4.0/. Details: http://jnm.snmjournals.org/site/misc/permission.xhtml.

REFERENCES

  1. 1.↵
    1. Senniappan S,
    2. Shanti B,
    3. James C,
    4. Hussain K.
    Hyperinsulinaemic hypoglycaemia: genetic mechanisms, diagnosis and management. J Inherit Metab Dis. 2012;35:589–601.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Demirbilek H,
    2. Hussain K.
    Congenital hyperinsulinism: diagnosis and treatment update. J Clin Res Pediatr Endocrinol. 2017;9:69–87.
    OpenUrl
  3. 3.↵
    1. Gutgold A,
    2. Gross DJ,
    3. Glaser B,
    4. Szalat A.
    Diagnosis of ABCC8 congenital hyperinsulinism of infancy in a 20-year-old man evaluated for factitious hypoglycemia. J Clin Endocrinol Metab. 2017;102:345–349.
    OpenUrl
  4. 4.↵
    1. Galcheva S,
    2. Al-Khawaga S,
    3. Hussain K.
    Diagnosis and management of hyperinsulinaemic hypoglycaemia. Best Pract Res Clin Endocrinol Metab. 2018;32:551–573.
    OpenUrl
  5. 5.↵
    1. Ferrara C,
    2. Patel P,
    3. Becker S,
    4. Stanley CA,
    5. Kelly A.
    Biomarkers of insulin for the diagnosis of hyperinsulinemic hypoglycemia in infants and children. J Pediatr. 2016;168:212–219.
    OpenUrlPubMed
  6. 6.↵
    1. Han B,
    2. Newbould M,
    3. Batra G,
    4. et al
    . Enhanced islet cell nucleomegaly defines diffuse congenital hyperinsulinism in infancy but not other forms of the disease. Am J Clin Pathol. 2016;145:757–768.
    OpenUrlCrossRefPubMed
  7. 7.↵
    1. Lord K,
    2. Dzata E,
    3. Snider KE,
    4. Gallagher PR,
    5. De Leon DD.
    Clinical presentation and management of children with diffuse and focal hyperinsulinism: a review of 223 cases. J Clin Endocrinol Metab. 2013;98:E1786–E1789.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Beltrand J,
    2. Caquard M,
    3. Arnoux JB,
    4. et al
    . Glucose metabolism in 105 children and adolescents after pancreatectomy for congenital hyperinsulinism. Diabetes Care. 2012;35:198–203.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Fournet JC,
    2. Mayaud C,
    3. de Lonlay P,
    4. et al
    . Unbalanced expression of 11p15 imprinted genes in focal forms of congenital hyperinsulinism: association with a reduction to homozygosity of a mutation in ABCC8 or KCNJ11. Am J Pathol. 2001;158:2177–2184.
    OpenUrlCrossRefPubMed
  10. 10.↵
    1. Verkarre V,
    2. Fournet JC,
    3. de Lonlay P,
    4. et al
    . Paternal mutation of the sulfonylurea receptor (SUR1) gene and maternal loss of 11p15 imprinted genes lead to persistent hyperinsulinism in focal adenomatous hyperplasia. J Clin Invest. 1998;102:1286–1291.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Bax KN,
    2. van der Zee DC.
    The laparoscopic approach toward hyperinsulinism in children. Semin Pediatr Surg. 2007;16:245–251.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Otonkoski T,
    2. Nanto-Salonen K,
    3. Seppanen M,
    4. et al
    . Noninvasive diagnosis of focal hyperinsulinism of infancy with [18F]-DOPA positron emission tomography. Diabetes. 2006;55:13–18.
    OpenUrlAbstract/FREE Full Text
  13. 13.↵
    1. Laje P,
    2. States LJ,
    3. Zhuang H,
    4. et al
    . Accuracy of PET/CT scan in the diagnosis of the focal form of congenital hyperinsulinism. J Pediatr Surg. 2013;48:388–393.
    OpenUrl
  14. 14.↵
    1. Brom M,
    2. Oyen WJ,
    3. Joosten L,
    4. Gotthardt M,
    5. Boerman OC.
    68Ga-labelled exendin-3, a new agent for the detection of insulinomas with PET. Eur J Nucl Med Mol Imaging. 2010;37:1345–1355.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Antwi K,
    2. Fani M,
    3. Heye T,
    4. et al
    . Comparison of glucagon-like peptide-1 receptor (GLP-1R) PET/CT, SPECT/CT and 3T MRI for the localisation of occult insulinomas: evaluation of diagnostic accuracy in a prospective crossover imaging study. Eur J Nucl Med Mol Imaging. 2018;45:2318–2327.
    OpenUrl
  16. 16.↵
    1. Antwi K,
    2. Fani M,
    3. Nicolas G,
    4. et al
    . Localization of hidden insulinomas with 68Ga-DOTA-exendin-4 PET/CT: a pilot study. J Nucl Med. 2015;56:1075–1078.
    OpenUrlAbstract/FREE Full Text
  17. 17.↵
    1. Hardy OT,
    2. Hernandez-Pampaloni M,
    3. Saffer JR,
    4. et al
    . Diagnosis and localization of focal congenital hyperinsulinism by 18F-fluorodopa PET scan. J Pediatr. 2007;150:140–145.
    OpenUrlCrossRefPubMed
  18. 18.↵
    1. Treglia G,
    2. Mirk P,
    3. Giordano A,
    4. Rufini V.
    Diagnostic performance of fluorine-18-dihydroxyphenylalanine positron emission tomography in diagnosing and localizing the focal form of congenital hyperinsulinism: a meta-analysis. Pediatr Radiol. 2012;42:1372–1379.
    OpenUrlPubMed
  19. 19.↵
    1. Boss M,
    2. Buitinga M,
    3. Jansen TJP,
    4. Brom M,
    5. Visser EP,
    6. Gotthardt M.
    PET-based human dosimetry of 68Ga-NODAGA-exendin-4, a tracer for beta-cell imaging. J Nucl Med. 2020;61:112–116.
    OpenUrlAbstract/FREE Full Text
  • Received for publication March 17, 2021.
  • Revision received May 5, 2021.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 63 (2)
Journal of Nuclear Medicine
Vol. 63, Issue 2
February 1, 2022
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
68Ga-NODAGA-Exendin-4 PET/CT Improves the Detection of Focal Congenital Hyperinsulinism
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
68Ga-NODAGA-Exendin-4 PET/CT Improves the Detection of Focal Congenital Hyperinsulinism
Marti Boss, Christof Rottenburger, Winfried Brenner, Oliver Blankenstein, Vikas Prasad, Sonal Prasad, Paolo de Coppi, Peter Kühnen, Mijke Buitinga, Pirjo Nuutila, Timo Otonkoski, Khalid Hussain, Maarten Brom, Annemarie Eek, Jamshed Bomanji, Pratik Shah, Martin Gotthardt
Journal of Nuclear Medicine Feb 2022, 63 (2) 310-315; DOI: 10.2967/jnumed.121.262327

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
68Ga-NODAGA-Exendin-4 PET/CT Improves the Detection of Focal Congenital Hyperinsulinism
Marti Boss, Christof Rottenburger, Winfried Brenner, Oliver Blankenstein, Vikas Prasad, Sonal Prasad, Paolo de Coppi, Peter Kühnen, Mijke Buitinga, Pirjo Nuutila, Timo Otonkoski, Khalid Hussain, Maarten Brom, Annemarie Eek, Jamshed Bomanji, Pratik Shah, Martin Gotthardt
Journal of Nuclear Medicine Feb 2022, 63 (2) 310-315; DOI: 10.2967/jnumed.121.262327
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • ACKNOWLEDGMENTS
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • PubMed
  • Google Scholar

Cited By...

  • Improved Localization of Insulinomas Using 68Ga-NODAGA-Exendin-4 PET/CT
  • Quantifying stem cell derived islet graft volume and composition with [18F]F-DBCO-exendin and [18F]FDOPA positron emission tomography
  • Google Scholar

More in this TOC Section

  • MHC-I–Driven Antitumor Immunity Counterbalances Low Absorbed Doses of Radiopharmaceutical Therapy
  • IL13Rα2-Targeting Antibodies for Immuno-PET in Solid Malignancies
  • Pilot Study of Nectin-4–Targeted PET Imaging Agent 68Ga-FZ-NR-1 in Triple-Negative Breast Cancer from Bench to First-in-Human
Show more FEATURED ARTICLE OF THE MONTH

Similar Articles

Keywords

  • congenital hyperinsulinism
  • focal CHI
  • diagnostic imaging
  • 68Ga-NODAGA-exendin-4 PET/CT
  • 18F-DOPA PET/CT
SNMMI

© 2025 SNMMI

Powered by HighWire