Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleTheranostics

The Impact of Monosodium Glutamate on 68Ga-PSMA-11 Biodistribution in Men with Prostate Cancer: A Prospective Randomized, Controlled Imaging Study

Wesley R. Armstrong, Andrei Gafita, Shaojun Zhu, Pan Thin, Kathleen Nguyen, Rejah Alano, Stephanie Lira, Kiara Booker, Linda Gardner, Tristan Grogan, David Elashoff, Martin Allen-Auerbach, Magnus Dahlbom, Johannes Czernin and Jeremie Calais
Journal of Nuclear Medicine September 2021, 62 (9) 1244-1251; DOI: https://doi.org/10.2967/jnumed.120.257931
Wesley R. Armstrong
1Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Andrei Gafita
1Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Shaojun Zhu
1Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pan Thin
1Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kathleen Nguyen
1Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Rejah Alano
1Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stephanie Lira
1Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kiara Booker
1Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Linda Gardner
1Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tristan Grogan
2Department of Medicine Statistics Core, David Geffen School of Medicine, UCLA, Los Angeles, California;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
David Elashoff
2Department of Medicine Statistics Core, David Geffen School of Medicine, UCLA, Los Angeles, California;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Martin Allen-Auerbach
1Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California;
3Institute of Urologic Oncology, UCLA, Los Angeles, California;
4Jonsson Comprehensive Cancer Center, UCLA, Los Angeles, California; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Magnus Dahlbom
1Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California;
5Physics and Biology in Medicine Interdepartmental Graduate Program, David Geffen School of Medicine, UCLA, Los Angeles, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Johannes Czernin
1Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California;
3Institute of Urologic Oncology, UCLA, Los Angeles, California;
4Jonsson Comprehensive Cancer Center, UCLA, Los Angeles, California; and
5Physics and Biology in Medicine Interdepartmental Graduate Program, David Geffen School of Medicine, UCLA, Los Angeles, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jeremie Calais
1Ahmanson Translational Theranostics Division, Department of Molecular and Medical Pharmacology, UCLA, Los Angeles, California;
3Institute of Urologic Oncology, UCLA, Los Angeles, California;
4Jonsson Comprehensive Cancer Center, UCLA, Los Angeles, California; and
5Physics and Biology in Medicine Interdepartmental Graduate Program, David Geffen School of Medicine, UCLA, Los Angeles, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

The prostate-specific membrane antigen (PSMA) has been targeted for PET imaging and radioligand therapy (RLT) in patients with prostate cancer. Xerostomia is a common side effect of RLT because of the high salivary gland uptake of PSMA radioligands. Here, we aimed to determine the impact of monosodium glutamate (MSG) administration on PSMA-radioligand biodistribution within healthy organs and tumor lesions by using 68Ga-PSMA-11 PET imaging. Methods: Sixteen men with prostate cancer were randomized (1:1) into oral ingestion and oral topical application (“swishing”) arms. Each subject underwent 2 68Ga-PSMA-11 PET/CT scans within 14 d under baseline and MSG conditions. The salivary glands and whole-body tumor lesions were segmented using qPSMA software. We quantified tracer uptake via SUVmean and SUVmax and compared parameters within each patient. Results: For the oral ingestion arm, salivary gland SUVmean and SUVmax decreased on average from the control scan to the MSG scan by 45% ± 15% (P = 0.004) and 53% ± 11% (P < 0.001), respectively. Tumor lesion SUVmean and SUVmax also decreased by 38% (interquartile range, −67% to −33%) and −52% (interquartile range, −70% to −49%), respectively (P = 0.018). Swishing had no significant effect on 68Ga-PSMA-11 accumulation in normal organs or tumor lesions. Conclusion: Oral ingestion but not topical application of MSG reduced 68Ga-PSMA-11 uptake in salivary glands. Tumor uptake also declined; therefore, the clinical application of MSG is unlikely to be useful in the framework of RLT.

  • monosodium glutamate
  • PSMA
  • PET/CT
  • xerostomia
  • salivary glands;

Prostate-specific membrane antigen (PSMA) is a transmembrane glycoprotein highly overexpressed by prostate cancer (PCa) cells (1). In recent years, PSMA has become an attractive target for both diagnosis and treatment of PCa (2). After their introduction for whole-body imaging with PET/CT, small-molecule PSMA ligands with a DOTA chelator, such as PSMA I&T or PSMA-617, were labeled with β-emitting (177Lu) or α-emitting (225Ac) isotopes for therapeutic purposes. PSMA-targeted radioligand therapy (RLT) with 177Lu demonstrated significant reductions in serum prostate-specific antigen (PSA) levels in phase 2 trials of metastatic castration-resistant PCa (3) and is currently being investigated in a phase 3 trial (VISION: NCT03511664). PSMA RLT with 225Ac, an α-emitter with a high energy deposition, may have enhanced therapeutic efficacy but has a less favorable toxicity profile (4, 5). The most concerning side effects include xerostomia, long-term nephrotoxicity, and myelosuppression (6–8). In particular, 225Ac-PSMA is associated with grade 2 or higher xerostomia, which often led to treatment cessation despite an initially favorable PSA response (4, 5, 9, 10). After the preliminary effects of 225Ac-PSMA on serum PSA levels, multiple efforts have failed to apply protective measures against salivary gland and kidney toxicity (11–14).

The salivary gland binding and uptake mechanism of PSMA radioligands remain unclear. There appears to be limited target expression by the salivary glands (low or intermediate immunohistochemistry PSMA staining intensity; patchy and focal expression, limited in extent [5% of salivary gland tissue]), whereas radioligand uptake is very high (15). In contrast, PSMA-targeted radioantibodies, such as 111In-J591 and 177Lu-J591, do not accumulate in the salivary glands or accumulate only at low levels (16). The high accumulation of the PSMA radioligands in the salivary glands may thus represent an off-target effect (i.e., related not to the PSMA target expression but to the radioligand molecules).

PSMA (also known as glutamate carboxypeptidase II) is targeted by small molecules via interaction of the glutamate moiety of the radioligands (among other features) with its enzymatic region, which has high glutamate affinity (17–19). Therefore, it was hypothesized that the administration of monosodium glutamate (MSG), a well-known food additive, could act as a competitor by blocking the binding of the PSMA-targeting radioligands. In a preclinical model, MSG reduced 68Ga-PSMA-11 salivary gland and renal uptake, whereas tumor accumulation was unaffected, in LNCap-bearing mice (20). Moreover, MSG stimulates salivary flow as shown in a controlled study, with up to a 1 mL/min mean salivary flow compared with 0.25 mL/min at baseline (21). We also hypothesized that MSG could be used as an oral salivary flow stimulant to remove accumulated radioligands from the salivary glands.

68Ga-PSMA-11 PET imaging is a rapid, noninvasive, and safe technique that provides reliable estimates of the biodistribution of therapeutic PSMA ligands.

In this imaging-controlled study on men with PCa, we determined the impact of MSG administration on PSMA-radioligand biodistribution in normal organs and tumors by using 68Ga-PSMA-11 PET/CT with and without MSG administration. We tested 2 administration methods: “swishing” (i.e., oral topical, to increase the salivary flow) and oral ingestion (for competitive binding).

MATERIALS AND METHODS

Study Design and Patient Population

This was a prospective single-center, open-label, randomized, controlled imaging study conducted at UCLA using 16 paired PSMA PET/CT studies with (MSG scan) and without (control scan) MSG administration, with less than 14 d between the 2 scans. The study was investigator-initiated, self-funded, conducted under an investigational new drug application (application 130649), approved by the local institutional review board (approval 18-001776), and registered on clinicaltrial.gov (NCT04282824).

Patients with histopathologically proven PCa who volunteered to undergo 2 PSMA PET/CT scans within 14 d and without any treatment change between the 2 scans were eligible. Patients with prior salivary gland surgery or radiation therapy, a history of salivary gland disease, severe uncontrolled hypertension, or a known allergic responses to MSG or who were unable to comply with the study procedures were excluded (Supplemental Table 1; supplemental materials are available at http://jnm.snmjournals.org). We obtained oral and written informed consent from all patients.

To preclude the potential confounding factor of stimulus effect, patients were initially randomized into 2 arms based on the type of MSG administration: oral ingestion (n = 8) and swishing (n = 8). A second randomization process subdivided the patients into receiving the control or MSG scan first. Figure 1 depicts the study flowchart.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Study flowchart.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Set of images of 73-y-old patient after radiation therapy (initial PSA, 16 ng/mL; biopsy Gleason score, 8; pT2c) and concurrent androgen hormone treatment, currently presenting for rising PSA value (6.27 ng/mL). After enrollment, patient was randomized to oral ingestion arm and received 18.9 g of MSG before second 68Ga-PSMA-11 injection. PSMA PET/CT images revealed multifocal prostate involvement, common iliac right and external iliac right pelvic lymph nodes, and multiple bone lesions. Maximum-intensity-projection images show overall decline in 68Ga-PSMA-11 accumulation within normal organs as well as tumor lesions on MSG scan relative to control scan. Axial view images display relevant case example of bone lesion with significant PSMA decrease after MSG administration (SUVmax from 18.6 to 9.2). p.i. = after injection.

Procedures

MSG Administration

We obtained food-grade MSG as a sealed salt powder (Ajinomoto). The U.S. Food and Drug Administration has designated MSG to be generally recognized as safe. Patients randomized to oral ingestion received a 150 mg/kg dose of food-grade MSG dissolved in 300 mL of drinking-grade water 30 min before 68Ga-PSMA-11 injection. Patients randomized to swishing received 0.5 M MSG, which they swished within the mouth for 30 s before removing the solution without swallowing. The swishing procedure was repeated at 0, 30, and 45 min after 68Ga-PSMA-11 injection.

Image Acquisition

68Ga-PSMA-11 (Glu-NH-CO-NH-Lys-(Ahx)-[68Ga(HBED-CC)]) was used as the PSMA ligand and was obtained from the Biomedical Cyclotron Facility at UCLA. 68Ga-PSMA-11 PET/CT imaging was performed according to international guidelines (22). The target injected activity dose was 185 MBq (allowed range, 111–259 MBq). The target uptake period was 60 min (allowed range, 50–100 min). We applied oral but no intravenous CT contrast medium for the control and MSG scans. We acquired images using a 64-detector PET/CT scanner (2007 Biograph 64 Truepoint or 2010 Biograph mCT 64; Siemens). The same scanner was used for both visits. A diagnostic CT scan (200–240 mAs, 120 kV) with a 5-mm slice thickness was obtained. PET images were acquired in 3-dimensional mode from mid thigh to vertex (whole-body scan) with a time of 2–4 min per bed position using a weight-based protocol (22). All PET images were reconstructed using corrections for attenuation, dead time, random events, and scatter. PET images were reconstructed with an iterative algorithm (ordered-subset expectation maximization) in an axial 168 × 168 matrix on the Biograph 64 Truepoint (2-dimensional, 2 iterations, 8 subsets, 5.0-mm gaussian filter) and in a 200 × 200 matrix on the Biograph mCT 64 (3-dimensional, 2 iterations, 24 subsets, 5.0-mm gaussian filter).

Image Analyses

Board-certified nuclear medicine physicians and radiologists used a PSMA PET/CT–based TNM staging system (PROMISE) to generate clinical reports of the control scans by consensus (23).

Two nuclear medicine physicians, who did not know the study condition (control vs. MSG administration and type of MSG application), used qPSMA software to interpret the research MSG and control PSMA PET/CT scans by consensus (24). They segmented all detected tumor lesions and normal organs manually. Normal organs included the lacrimal glands, parotid glands, submandibular glands, liver, spleen, kidneys, and urinary bladder. Output parameters included SUVmean and SUVmax for both tumor lesions and normal organs.

Measurements of Salivary Radioactivity

To assess the effect of MSG on radioligand excretion, we collected saliva from all patients at 5 time points after 68Ga-PSMA-11 injection at 0 min (range, 0–7 min), 10 min (range, 9–17 min), 30 min (range, 28–39 min), 45 min (range, 44–54 min), and 100 min (range, 88–126 min). We transferred saliva collected in disposable medication cups to disposable borosilicate test tubes. Samples were weighed and radioactivity was measured in a γ-well counter (Capintec CAPRAC-t; Mirion Technologies). Background was measured before each patient injection. We assayed 68Ga decay within a range of 10–1,200 keV and recorded the time of radioactivity collection and measurement to adjust for tracer decay. We corrected tracer uptake in saliva for background and radioactive decay.

Safety

We monitored safety before/after injection of the radiotracer, before/after the MSG administration, and before/after the scan procedure. We recorded blood pressure and heart rate before injection of 68Ga-PSMA-11 and directly after completion of the scan. We communicated with all patients within 72 h after the scan and asked whether they had any untoward side effects or symptoms. Adverse events were documented and evaluated according to the Common Terminology Criteria for Adverse Events, version 5.0.

Outcomes

The primary objective of this trial was to compare the degree of 68Ga-PSMA-11 uptake in the salivary glands with and without MSG administration. A 2-fold reduction after MSG administration was a priori defined as a successful reduction in salivary gland PSMA uptake (25). The secondary objectives were to determine the impact of MSG administration on 68Ga-PSMA-11 uptake in normal organs and tumor lesions, to measure whether MSG stimulates 68Ga-PSMA-11 excretion in the saliva, and to assess the safety of oral MSG ingestion and salivary flow stimulation at the proposed doses.

Statistical Analyses

Radiation doses to the salivary glands from 1 cycle of 225Ac-PSMA or 177Lu-PSMA were estimated at 17 and 10 Gy, respectively (9, 10, 26, 27). The commonly applied safe upper limit for external-beam salivary gland radiation therapy is 32 Gy, which can be reached after 2 cycles of 225Ac-PSMA (28). On the basis of these numbers, we aimed to achieve a 2-fold reduction in the 68Ga-PSMA-11 accumulation in the salivary glands after MSG administration. The primary endpoint measure was the mean difference in SUVmax and SUVmean in all assessable salivary glands with and without the administration of MSG interventions. Patients were randomized (1:1) using a computer-generated randomization list. The randomization plan used a permuted block design with 2 blocks of n = 8 (arms A and B, Supplemental Table 2).

We report descriptive values as mean ± SD or median and interquartile range (if data were not normally distributed according to the Shapiro–Wilk test). Because individual patients served as their own control, paired t tests were performed. Differences between paired data that were not normally distributed were determined using the Wilcoxon signed-rank test. The independent t test was used to compare the means between unrelated groups. In each analysis, a P value of less than 0.05 was considered statistically significant. We conducted all analyses using SPSS Statistics, version 26.0 (IBM Corp.), and R Studio, version 3.6.1 (R Foundation for Statistical Computing).

RESULTS

A summary image of each of the 16 patients, with all measurements, is provided in the supplemental materials (Supplemental Fig. 1). One patient example (patient 012) is displayed in Figure 2.

Patient Population

Between December 20, 2019, and April 4, 2020, 17 patients were screened to identify 16 patients who met the eligibility criteria (Fig. 1). One patient declined to participate. The demographics and clinical characteristics of the study population are presented in Table 1. Two of 16 (16%) patients underwent the PSMA PET/CT scan for initial staging of PCa, 7 of 16 (42%) for localization of biochemical recurrence, and 7 of 16 (42%) for restaging of metastatic disease.

View this table:
  • View inline
  • View popup
TABLE 1

Patient Characteristics

PSMA PET/CT Images

In the oral ingestion arm, the mean injected activity was 184 ± 1 and 183 ± 2 MBq for the MSG and control scans, respectively (P = 0.18). Image acquisition commenced at 61 ± 8 and 61 ± 7 min, respectively, after tracer injection (P = 0.87).

In the swishing arm, the mean injected activity was 184 ± 1 and 184 ± 1 MBq for the MSG and control scans, respectively (P = 0.40). Image acquisition commenced at 67 ± 15 and 66 ± 14 min, respectively, after tracer injection (P = 0.87).

Table 2 summarizes the scan findings and PSMA PET–based staging. Three patients had no visible PCa lesions (1 in the oral ingestion arm and 2 in the swishing arm). There was no change in stage between the control and MSG scans.

View this table:
  • View inline
  • View popup
TABLE 2

PSMA PET Findings

View this table:
  • View inline
  • View popup
TABLE 3

Comparison of 68Ga-PSMA11 Uptake in Normal Organs in Control and MSG Scans

68Ga-PSMA-11 Uptake in Normal Organs

In the oral ingestion arm, MSG administration was associated with a significant decrease in 68Ga-PSMA-11 accumulation in all normal organs (P < 0.05) and a large increase in bladder activity (mean difference, +372% SUVmean and +593% SUVmax; Table 3). 68Ga-PSMA-11 uptake decreased by more than 50% in the salivary glands (mean difference, −46% SUVmean and −53% SUVmax), with a more prominent effect on the submandibular glands (mean difference, −59% SUVmean and −63% SUVmax) than on the parotid glands (mean difference, −33% SUVmean and −34% SUVmax).

In the swishing arm, no statistically significant difference in 68Ga-PSMA-11 accumulation measured by either SUVmean and SUVmax was observed in normal organs after MSG administration (P > 0.05) (Table 3).

68Ga-PSMA-11 Uptake in Tumor Lesions

In the oral ingestion arm, MSG administration was associated with a significant decline in 68Ga-PSMA-11 accumulation in tumor lesions (median difference, −38% SUVmean and −52% SUVmax; Table 4). One pelvic bone lesion showed a dramatic decrease in SUVmax (from 46.8 to 4.3) after MSG administration (case MSG05 in the supplemental materials).

View this table:
  • View inline
  • View popup
TABLE 4

Comparison of SUVmean and SUVmax Derived from Control and MSG Scans

In the swishing arm, no significant difference in tumor accumulation of 68Ga-PSMA-11 as measured by SUVmean and SUVmax was observed between the 2 PET scans (P = 0.11 and P = 0.17, respectively) (Table 4).

A comparison of pooled SUVmean and SUVmax between the control and MSG studies for each arm is depicted in Figure 3.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

SUVmean (A) and SUVmax (B) of salivary glands, kidneys, and tumor lesions in control and MSG studies in oral ingestion and swishing arms.

Saliva Radioactivity Measurements

Salivary radioactivity increased over time, demonstrating 68Ga-PSMA-11 salivary excretion. The median activity counts after tracer injection for both arms are provided in Supplemental Table 3. Figure 4 shows the median saliva counts over time.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Median changes in 68Ga-PSMA11 activity in saliva between control and MSG groups at 0, 10, 30, 45, and 100 min after tracer injection for oral ingestion arm (A) and swishing arm (B).

In the oral ingestion arm, a significant decrease in salivary activity counts was observed at 45 and 100 min, with median reductions of −42% and −53%, respectively. In the swishing arm, no significant difference in salivary activity was observed at any time point (P > 0.05).

Adverse Events

Grade 1 nausea after administration was recorded in 1 (6%) of 16 patients after oral ingestion of MSG. Five non–study-related events were recorded (diarrhea [n = 2 in each arm] and abdominal discomfort [n = 1 in the swishing arm]; Supplemental Table 4).

DISCUSSION

This prospective randomized imaging study revealed that oral ingestion of MSG, a food additive, is associated with a significant decrease in 68Ga-PSMA-11 accumulation within normal organs and tumor lesions, whereas topical oral application of MSG has no impact on 68Ga-PSMA-11 biodistribution. The primary endpoint of at least a 50% decrease in 68Ga-PSMA-11 accumulation in the salivary glands was met when expressed as change in SUVmax (53%). However, oral administration of MSG also significantly diminished 68Ga-PSMA-11 uptake in tumor lesions (52% and 39% decline in SUVmax and SUVmean, respectively) and all other organs. A 3-fold increase in 68Ga-PSMA-11 signal in the urinary bladder highlighted rapidly increased urinary excretion after oral MSG administration. Previous work found a repeatability coefficient of 33%–38% for SUV measurements in PSMA PET/CT, indicating that the reduction in tumor uptake in our patients (>45%) is related to MSG administration (29). The application of MSG to reduce salivary gland toxicity (xerostomia) induced by PSMA RLT is therefore unlikely to be a successful clinical strategy.

Various direct attempts to reduce the salivary gland toxicity of 225Ac-PSMA have been reported: salivary gland duct dilation and clearance via sialendoscopy (30), vasoconstriction of parotid gland blood vessels through external cooling with ice packs (11, 13), and local injection of botulinum toxin A to suppress saliva formation metabolically (31). Indirect attempts to alter the biochemical mechanism of off-target binding by competition included PSMA inhibitors such as 2-(phosphonomethyl) pentanedioic acid or serum glutamate–elevating approaches (20, 32–35). Dosimetry data showed that coadministration of oral polyglutamate administration may reduce salivary gland ligand uptake. However, the impact on tumor uptake has not yet been determined (36).

Application of MSG in murine models reduced salivary PSMA radioligand uptake in a dose-dependent matter without affecting tumor uptake (20). In contrast, oral MSG administration in humans led to significant decreases in tumor uptake. Consistent with our findings, a significant decrease in 18F-DCFPyL accumulation in normal organs and tumor lesions after oral administration of MSG was also observed by others (32). Harsini et al. (32) applied a fix dose of 12.7 g, whereas our patients received a 150 mg/kg dose of MSG, which led to higher average dose of 15.1 g. This difference might explain the higher impact of MSG on tracer biodistribution observed in our study, a finding that suggests a dose-dependent effect of MSG. Although the MSG dosages were 10-fold higher than the MSG concentration in a normal meal (37), intake of food containing glutamate (e.g., MSG, umami, tomatoes, cheese, and mushrooms) may impact the biodistribution of PSMA radioligands, and a potential impact on diagnostic or therapy efficacy cannot be formally excluded. Further studies investigating the impact of food containing glutamate on imaging-and-therapy PSMA radioligands may be warranted.

68Ga-PSMA-11 is excreted in the saliva, as shown by our measurements. Oral ingestion of MSG led to diminished salivary excretion of 68Ga-PSMA-11. This finding suggests that its off-target accumulation in the salivary glands interacts with saliva formation, potentially impacting ductal cell transporters within the glands (15, 38). Alternatively, the macromolecular composition of saliva itself may be interacting with PSMA and glutamate, trapping or binding to the molecules and causing an accumulation in the salivary glands within saliva.

Our study had limitations. First, both the dosing and the timing of MSG administration were chosen empirically on the basis of studies largely concerned with safe dosing of MSG rather than application as a blood glutamate–modulating tool (39). Second, although not evaluated in this study, tumor burden may play a role in the efficacy of MSG’s impact on radioligand distribution. Although PSMA RLT is currently offered in heavily metastasized patients with late-stage metastatic castration-resistant PCa, our patients were mainly in earlier disease stages that have a low tumor burden. Nevertheless, considering the tumor sink effect, we expect a higher impact of MSG administration on tumor uptake in patients with a high tumor burden (40).

CONCLUSION

Oral administration of MSG successfully decreased 68Ga-PSMA-11 uptake in normal organs, including the salivary glands and kidneys, in human subjects but also reduced tumor uptake significantly. This result suggests that MSG strategies reducing the salivary gland toxicity of PSMA RLT will negatively impact tumor PSMA uptake. Thus, clinical applicability is unlikely. Future investigations evaluating different doses and timings of MSG administration are warranted, considering the possibility that a lower dose may show differential preference for tumor or normal tissue.

DISCLOSURE

No potential conflict of interest relevant to this article was reported.

KEY POINTS

  • QUESTION: What is the impact of MSG administration on 68Ga-PSMA11 biodistribution?

  • PERTINENT FINDINGS: This prospective single-center, randomized imaging study, which included 16 men with PCa, met its primary endpoint, defined as a 50% reduction in 68Ga-PSMA11 accumulation in the salivary glands when MSG was administered orally (−53.4% SUVmax, P < 0.001). However, the radiotracer reduction in normal organs was accompanied by a significant reduction within tumor lesions (−55.7% SUVmax, P = 0.061).

  • IMPLICATIONS FOR PATIENT CARE: MSG is capable of modulating 68Ga-PSMA-11 biodistribution, including tumor uptake, which limits its clinical application in the setting of PSMA RLT.

Footnotes

  • ↵* Contributed equally to this work.

  • Published online January 28, 2021.

  • © 2021 by the Society of Nuclear Medicine and Molecular Imaging.

REFERENCES

  1. 1.↵
    1. Silver DA,
    2. Pellicer I,
    3. Fair WR,
    4. Heston WD,
    5. Cordon-Cardo C.
    Prostate-specific membrane antigen expression in normal and malignant human tissues. Clin Cancer Res. 1997;3:81–85.
    OpenUrlAbstract
  2. 2.↵
    1. Eiber M,
    2. Fendler WP,
    3. Rowe SP,
    4. et al
    . Prostate-specific membrane antigen ligands for imaging and therapy. J Nucl Med. 2017;58(suppl):67S–76S.
    OpenUrlAbstract/FREE Full Text
  3. 3.↵
    1. Hofman MS,
    2. Violet J,
    3. Hicks RJ,
    4. et al
    . [177Lu]-PSMA-617 radionuclide treatment in patients with metastatic castration-resistant prostate cancer (LuPSMA trial): a single-centre, single-arm, phase 2 study. Lancet Oncol. 2018;19:825–833.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Kratochwil C,
    2. Bruchertseifer F,
    3. Rathke H,
    4. et al
    . Targeted alpha-therapy of metastatic castration-resistant prostate cancer with 225Ac-PSMA-617: swimmer-plot analysis suggests efficacy regarding duration of tumor control. J Nucl Med. 2018;59:795–802.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Sathekge M,
    2. Bruchertseifer F,
    3. Knoesen O,
    4. et al
    . 225Ac-PSMA-617 in chemotherapy-naive patients with advanced prostate cancer: a pilot study. Eur J Nucl Med Mol Imaging. 2019;46:129–138.
    OpenUrl
  6. 6.↵
    1. Okamoto S,
    2. Thieme A,
    3. Allmann J,
    4. et al
    . Radiation dosimetry for 177Lu-PSMA I&T in metastatic castration-resistant prostate cancer: absorbed dose in normal organs and tumor lesions. J Nucl Med. 2017;58:445–450.
    OpenUrlAbstract/FREE Full Text
  7. 7.
    1. Fendler WP,
    2. Reinhardt S,
    3. Ilhan H,
    4. et al
    . Preliminary experience with dosimetry, response and patient reported outcome after 177Lu-PSMA-617 therapy for metastatic castration-resistant prostate cancer. Oncotarget. 2017;8:3581–3590.
    OpenUrl
  8. 8.↵
    1. Baum RP,
    2. Kulkarni HR,
    3. Schuchardt C,
    4. et al
    . 177Lu-labeled prostate-specific membrane antigen radioligand therapy of metastatic castration-resistant prostate cancer: safety and efficacy. J Nucl Med. 2016;57:1006–1013.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Kratochwil C,
    2. Bruchertseifer F,
    3. Rathke H,
    4. et al
    . Targeted alpha-therapy of metastatic castration-resistant prostate cancer with 225Ac-PSMA-617: dosimetry estimate and empiric dose finding. J Nucl Med. 2017;58:1624–1631.
    OpenUrlAbstract/FREE Full Text
  10. 10.↵
    1. Kratochwil C,
    2. Bruchertseifer F,
    3. Giesel FL,
    4. et al
    . 225Ac-PSMA-617 for PSMA-targeted alpha-radiation therapy of metastatic castration-resistant prostate cancer. J Nucl Med. 2016;57:1941–1944.
    OpenUrlAbstract/FREE Full Text
  11. 11.↵
    1. van Kalmthout LWM,
    2. Lam M,
    3. de Keizer B,
    4. et al
    . Impact of external cooling with icepacks on 68Ga-PSMA uptake in salivary glands. EJNMMI Res. 2018;8:56.
    OpenUrl
  12. 12.
    1. Langbein T,
    2. Chausse G,
    3. Baum RP.
    Salivary gland toxicity of PSMA radioligand therapy: relevance and preventive strategies. J Nucl Med. 2018;59:1172–1173.
    OpenUrlFREE Full Text
  13. 13.↵
    1. Yilmaz B,
    2. Nisli S,
    3. Ergul N,
    4. Gursu RU,
    5. Acikgoz O,
    6. Cermik TF.
    Effect of external cooling on 177Lu-PSMA uptake by the parotid glands. J Nucl Med. 2019;60:1388–1393.
    OpenUrlAbstract/FREE Full Text
  14. 14.↵
    1. Bander NH,
    2. Milowsky MI,
    3. Nanus DM,
    4. Kostakoglu L,
    5. Vallabhajosula S,
    6. Goldsmith SJ.
    Phase I trial of 177lutetium-labeled J591, a monoclonal antibody to prostate-specific membrane antigen, in patients with androgen-independent prostate cancer. J Clin Oncol. 2005;23:4591–4601.
    OpenUrlAbstract/FREE Full Text
  15. 15.↵
    1. Rupp NJ,
    2. Umbricht CA,
    3. Pizzuto DA,
    4. et al
    . First clinicopathologic evidence of a non-PSMA-related uptake mechanism for 68Ga-PSMA-11 in salivary glands. J Nucl Med. 2019;60:1270–1276.
    OpenUrl
  16. 16.↵
    1. Tagawa ST,
    2. Vallabhajosula S,
    3. Christos PJ,
    4. et al
    . Phase 1/2 study of fractionated dose lutetium-177-labeled anti-prostate-specific membrane antigen monoclonal antibody J591 (177Lu-J591) for metastatic castration-resistant prostate cancer. Cancer. 2019;125:2561–2569.
    OpenUrl
  17. 17.↵
    1. Wang H,
    2. Byun Y,
    3. Barinka C,
    4. et al
    . Bioisosterism of urea-based GCPII inhibitors: synthesis and structure-activity relationship studies. Bioorg Med Chem Lett. 2010;20:392–397.
    OpenUrlPubMed
  18. 18.
    1. Eder M,
    2. Schafer M,
    3. Bauder-Wust U,
    4. et al
    . 68Ga-complex lipophilicity and the targeting property of a urea-based PSMA inhibitor for PET imaging. Bioconjug Chem. 2012;23:688–697.
    OpenUrlCrossRefPubMed
  19. 19.↵
    1. Navrátil M,
    2. Ptacek J,
    3. Sacha P,
    4. et al
    . Structural and biochemical characterization of the folyl-poly-gamma-l-glutamate hydrolyzing activity of human glutamate carboxypeptidase II. FEBS J. 2014;281:3228–3242.
    OpenUrlCrossRefPubMed
  20. 20.↵
    1. Rousseau E,
    2. Lau J,
    3. Kuo HT,
    4. et al
    . Monosodium glutamate reduces 68Ga-PSMA-11 uptake in salivary glands and kidneys in a preclinical prostate cancer model. J Nucl Med. 2018;59:1865–1868.
    OpenUrlAbstract/FREE Full Text
  21. 21.↵
    1. Hodson NA,
    2. Linden RW.
    The effect of monosodium glutamate on parotid salivary flow in comparison to the response to representatives of the other four basic tastes. Physiol Behav. 2006;89:711–717.
    OpenUrlCrossRefPubMed
  22. 22.↵
    1. Fendler WP,
    2. Eiber M,
    3. Beheshti M,
    4. et al
    . 68Ga-PSMA PET/CT: joint EANM and SNMMI procedure guideline for prostate cancer imaging: version 1.0. Eur J Nucl Med Mol Imaging. 2017;44:1014–1024.
    OpenUrl
  23. 23.↵
    1. Eiber M,
    2. Herrmann K,
    3. Calais J,
    4. et al
    . Prostate Cancer Molecular Imaging Standardized Evaluation (PROMISE): proposed miTNM classification for the interpretation of PSMA-ligand PET/CT. J Nucl Med. 2018;59:469–478.
    OpenUrlAbstract/FREE Full Text
  24. 24.↵
    1. Gafita A,
    2. Bieth M,
    3. Krönke M,
    4. et al
    . qPSMA: semiautomatic software for whole-body tumor burden assessment in prostate cancer using 68Ga-PSMA11 PET/CT. J Nucl Med. 2019;60:1–1283.
    OpenUrlFREE Full Text
  25. 25.↵
    1. Kratochwil C,
    2. Fendler WP,
    3. Eiber M,
    4. et al
    . EANM procedure guidelines for radionuclide therapy with 177Lu-labelled PSMA-ligands (177Lu-PSMA-RLT). Eur J Nucl Med Mol Imaging. 2019;46:2536–2544.
    OpenUrl
  26. 26.↵
    1. Delker A,
    2. Fendler WP,
    3. Kratochwil C,
    4. et al
    . Dosimetry for 177Lu-DKFZ-PSMA-617: a new radiopharmaceutical for the treatment of metastatic prostate cancer. Eur J Nucl Med Mol Imaging. 2016;43:42–51.
    OpenUrlCrossRefPubMed
  27. 27.↵
    1. Yadav MP,
    2. Ballal S,
    3. Tripathi M,
    4. et al
    . Post-therapeutic dosimetry of 177Lu-DKFZ-PSMA-617 in the treatment of patients with metastatic castration-resistant prostate cancer. Nucl Med Commun. 2017;38:91–98.
    OpenUrl
  28. 28.↵
    1. Emami B,
    2. Lyman J,
    3. Brown A,
    4. et al
    . Tolerance of normal tissue to therapeutic irradiation. Int J Radiat Oncol Biol Phys. 1991;21:109–122.
    OpenUrlCrossRefPubMed
  29. 29.↵
    1. Pollard JH,
    2. Raman C,
    3. Zakharia Y,
    4. et al
    . Quantitative test-retest measurement of 68Ga-PSMA-HBED-CC in tumor and normal tissue. J Nucl Med. 2020;61:1145–1152.
    OpenUrl
  30. 30.↵
    1. Rathke H,
    2. Kratochwil C,
    3. Hohenberger R,
    4. et al
    . Initial clinical experience performing sialendoscopy for salivary gland protection in patients undergoing 225Ac-PSMA-617 RLT. Eur J Nucl Med Mol Imaging. 2019;46:139–147.
    OpenUrl
  31. 31.↵
    1. Baum RP,
    2. Langbein T,
    3. Singh A,
    4. et al
    . Injection of botulinum toxin for preventing salivary gland toxicity after PSMA radioligand therapy: an empirical proof of a promising concept. Nucl Med Mol Imaging. 2018;52:80–81.
    OpenUrl
  32. 32.↵
    1. Harsini S,
    2. Saprunoff H,
    3. Alden T,
    4. Mohammadi B,
    5. Wilson D,
    6. Bénard F.
    The effects of monosodium glutamate on PSMA radiotracer uptake in men with recurrent prostate cancer: a prospective, randomized, double-blind, placebo-controlled intraindividual imaging study. J Nucl Med. 2021;62:81–87.
    OpenUrlAbstract/FREE Full Text
  33. 33.
    1. Paganelli G,
    2. Sarnelli A,
    3. Severi S,
    4. et al
    . Dosimetry and safety of 177Lu PSMA-617 along with polyglutamate parotid gland protector: preliminary results in metastatic castration-resistant prostate cancer patients. Eur J Nucl Med Mol Imaging. 2020;47:3008–3017.
  34. 34.
    1. Majer P,
    2. Jancarik A,
    3. Krecmerova M,
    4. et al
    . Discovery of orally available prodrugs of the glutamate carboxypeptidase II (GCPII) inhibitor 2-phosphonomethylpentanedioic acid (2-PMPA). J Med Chem. 2016;59:2810–2819.
    OpenUrl
  35. 35.↵
    1. Kratochwil C,
    2. Giesel FL,
    3. Leotta K,
    4. et al
    . PMPA for nephroprotection in PSMA-targeted radionuclide therapy of prostate cancer. J Nucl Med. 2015;56:293–298.
    OpenUrlAbstract/FREE Full Text
  36. 36.↵
    1. Sarnelli A,
    2. Belli ML,
    3. Di Iorio V,
    4. et al
    . Dosimetry of 177Lu-PSMA-617 after mannitol infusion and glutamate tablet administration: preliminary results of EUDRACT/RSO 2016-002732-32 IRST protocol. Molecules. 2019;24:621.
  37. 37.↵
    1. He K,
    2. Du S,
    3. Xun P,
    4. et al
    . Consumption of monosodium glutamate in relation to incidence of overweight in Chinese adults: China Health and Nutrition Survey (CHNS). Am J Clin Nutr. 2011;93:1328–1336.
    OpenUrlAbstract/FREE Full Text
  38. 38.↵
    1. Sunavala-Dossabhoy G.
    Radioactive iodine: an unappreciated threat to salivary gland function. Oral Dis. 2018;24:198–201.
    OpenUrl
  39. 39.↵
    1. Fernstrom JD,
    2. Cameron JL,
    3. Fernstrom MH,
    4. McConaha C,
    5. Weltzin TE,
    6. Kaye WH.
    Short-term neuroendocrine effects of a large oral dose of monosodium glutamate in fasting male subjects. J Clin Endocrinol Metab. 1996;81:184–191.
    OpenUrlCrossRefPubMed
  40. 40.↵
    1. Gaertner FC,
    2. Halabi K,
    3. Ahmadzadehfar H,
    4. et al
    . Uptake of PSMA-ligands in normal tissues is dependent on tumor load in patients with prostate cancer. Oncotarget. 2017;8:55094–55103.
    OpenUrl
  • Received for publication October 1, 2020.
  • Accepted for publication December 29, 2020.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 62 (9)
Journal of Nuclear Medicine
Vol. 62, Issue 9
September 1, 2021
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The Impact of Monosodium Glutamate on 68Ga-PSMA-11 Biodistribution in Men with Prostate Cancer: A Prospective Randomized, Controlled Imaging Study
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
The Impact of Monosodium Glutamate on 68Ga-PSMA-11 Biodistribution in Men with Prostate Cancer: A Prospective Randomized, Controlled Imaging Study
Wesley R. Armstrong, Andrei Gafita, Shaojun Zhu, Pan Thin, Kathleen Nguyen, Rejah Alano, Stephanie Lira, Kiara Booker, Linda Gardner, Tristan Grogan, David Elashoff, Martin Allen-Auerbach, Magnus Dahlbom, Johannes Czernin, Jeremie Calais
Journal of Nuclear Medicine Sep 2021, 62 (9) 1244-1251; DOI: 10.2967/jnumed.120.257931

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
The Impact of Monosodium Glutamate on 68Ga-PSMA-11 Biodistribution in Men with Prostate Cancer: A Prospective Randomized, Controlled Imaging Study
Wesley R. Armstrong, Andrei Gafita, Shaojun Zhu, Pan Thin, Kathleen Nguyen, Rejah Alano, Stephanie Lira, Kiara Booker, Linda Gardner, Tristan Grogan, David Elashoff, Martin Allen-Auerbach, Magnus Dahlbom, Johannes Czernin, Jeremie Calais
Journal of Nuclear Medicine Sep 2021, 62 (9) 1244-1251; DOI: 10.2967/jnumed.120.257931
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Theranostics

  • Determination of the Intralesional Distribution of Theranostic 124I-Omburtamab Convection-Enhanced Delivery in Treatment of Diffuse Intrinsic Pontine Glioma
  • Evidence-Based Clinical Protocols to Monitor Efficacy of [177Lu]Lu-PSMA Radiopharmaceutical Therapy in Metastatic Castration-Resistant Prostate Cancer Using Real-World Data
  • 177Lu-Labeled Anticlaudin 6 Monoclonal Antibody for Targeted Therapy in Esophageal Cancer
Show more Theranostics

Clinical

  • TauIQ: A Canonical Image Based Algorithm to Quantify Tau PET Scans
  • Dual PET Imaging in Bronchial Neuroendocrine Neoplasms: The NETPET Score as a Prognostic Biomarker
  • Addition of 131I-MIBG to PRRT (90Y-DOTATOC) for Personalized Treatment of Selected Patients with Neuroendocrine Tumors
Show more Clinical

Similar Articles

Keywords

  • monosodium glutamate
  • PSMA
  • PET/CT
  • xerostomia
  • salivary glands;
SNMMI

© 2025 SNMMI

Powered by HighWire