Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleBasic Science Investigation

Patient Size-Dependent Dosimetry Methodology Applied to 18F-FDG Using New ICRP Mesh Phantoms

Lukas M. Carter, Chansoo Choi, Simone Krebs, Bradley J. Beattie, Chan Hyeong Kim, Heiko Schoder, Wesley E. Bolch and Adam L. Kesner
Journal of Nuclear Medicine December 2021, 62 (12) 1805-1814; DOI: https://doi.org/10.2967/jnumed.120.256719
Lukas M. Carter
1Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chansoo Choi
2Department of Nuclear Engineering, Hanyang University, Seoul, Republic of Korea;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Simone Krebs
3Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Bradley J. Beattie
1Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chan Hyeong Kim
2Department of Nuclear Engineering, Hanyang University, Seoul, Republic of Korea;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Heiko Schoder
3Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wesley E. Bolch
4J. Crayton Pruitt Department of Biomedical Engineering, University of Florida, Gainesville, Florida
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Adam L. Kesner
1Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

Despite the known influence of anatomic variability on internal dosimetry, dosimetry for 18F-FDG and other diagnostic radiopharmaceuticals is routinely derived using reference phantoms, which embody population-averaged morphometry for a given age and sex. Moreover, phantom format affects dosimetry estimates to a varying extent. Here, we applied newly developed mesh format reference phantoms and a patient-dependent phantom library to assess the impact of height, weight, and body contour variation on dosimetry of 18F-FDG. We compared the mesh reference phantom dosimetry estimates with corresponding estimates from common software to identify differences related to phantom format or software implementation. Our study serves as an example of how more precise patient size–dependent dosimetry methodology could be performed. Methods: Absorbed dose coefficients were computed for the adult mesh reference phantoms and for a derivative patient-dependent phantom series by Monte Carlo simulation using the Particle and Heavy Ion Transport Code System (PHITS) within the software called PARaDIM (PHITS-Based Application for Radionuclide Dosimetry in Meshes). The dose coefficients were compared with reference absorbed dose coefficients obtained from International Commission on Radiological Protection publication 128 or were generated using software including OLINDA 2.1, OLINDA 1.1, and IDAC-Dose 2.1. Results: Differences in dosimetry arising from anatomic variations were shown to be significant, with detriment-weighted dose coefficients for the percentile-specific phantoms varying by up to ±40% relative to the corresponding reference phantom effective dose coefficients, irrespective of phantom format. Similar variations were seen in the individual organ absorbed dose coefficients for the percentile-specific phantoms relative to the reference phantoms. The effective dose coefficient for the mesh reference adult was 0.017 mSv/MBq, which was 5% higher than estimated by a corresponding voxel phantom and 10% lower than estimated by the stylized phantom format. Conclusion: We observed notable variability in 18F-FDG dosimetry across morphometrically different patients, supporting the use of patient-dependent phantoms for more accurate dosimetric estimations relative to standard reference dosimetry. The methodology employed may help in optimizing imaging protocols and research studies, in particular when longer-lived isotopes are used.

  • FDG
  • patient-dependent dosimetry
  • PARaDIM
  • PHITS
  • phantom

The most widely used diagnostic radiopharmaceutical in oncology is 18F-FDG, with 2.2 million clinical PET scans performed across U.S. facilities in 2019 (1). The typical effective dose from 18F-FDG imaging is approximately 10mSv and is considered low (2,3). Nevertheless, the increasing use of radiation-based medical imaging over the past several decades has led to concerns about possible detriment, and these concerns have precipitated campaigns such as Image Wisely (adult patients) and Image Gently (pediatric patients) (4,5). A cornerstone of those campaigns is attention to optimization. Accurate dosimetry is fundamental to understanding relationships between radiation dose and patient detriment and is needed to provide objective recommendations for administered activity for different patient populations (6).

Dosimetry estimates in nuclear medicine are derived using Monte Carlo–based dose calculations incorporating computerized representations of anatomy known as computational phantoms. The accuracy of these estimates depends on the degree to which anatomic features of the patient are modeled within the phantom. Virtually all routine dosimetry estimates for 18F-FDG in adult patients have used standard reference (i.e., non–patient-specific) phantoms to represent patient anatomy. Reference phantoms serve to define an average patient based on only age and sex criteria; they do not consider differing body sizes and organ dimensions, which may influence absorbed dose calculations by 20%–60% (7). The geometric format (e.g., mesh, voxel, stylized, or hybrid) used to define the phantom anatomy further influences dose calculations. Despite the availability of more modern formats, stylized adult phantoms (8,9) as described in International Commission on Radiological Protection (ICRP) publication 23 (10) continue to be routinely used in nuclear medicine dosimetry software and provide the underpinning for dose coefficients promulgated in currently accepted sources of radiopharmaceutical reference data (7). Limitations of stylized phantoms include reliance on simple linear and quadratic surface equations, which coarsely approximate human anatomy and generally underestimate organ cross-dose contributions for low-energy photons. Progress in computational phantom and Monte Carlo code development (11–18) now enables more accurate dosimetry protocols, which will support dosimetry research, optimization of clinical imaging protocols, and planning of research studies.

The ICRP recently developed mesh format reference computational phantoms for the adult male and female, and these phantoms provide anatomically more realistic representations of the human body (Fig. 1) (19). For example, these phantoms define numerous additional source and target regions and define small, thin, or complex radiosensitive target regions impractical to treat using voxel or stylized phantom formats. More recently, the adult mesh reference phantoms were reshaped and scaled to match Caucasian patient population-dependent parameters extracted from anthropometric survey data (20,21)––culminating in an additional 9 male and 9 female phantoms representing the 10th, 50th, and 90th percentiles of standing height and weight for the adult Caucasian population. Termed the percentile-specific phantom series, these 18 phantoms are morphometrically considered patient-dependent phantoms and foster research into dosimetric implications of adult patient size variability across population subsets (22).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Comparison of phantom formats. (Left) MIRD 5 era stylized adult anthropomorphic phantom (1969; ∼25 source/target organs) used in OLINDA 1.0 and ICRP 128. (Middle) ICRP 110 adult male voxel phantom (2009; 79 source regions, 43 target regions) used in IDAC-Dose 2.1. (Right) ICRP mesh reference adult male (2020; 190 source regions, 153 target regions) archetypal example used in this work.

A primary objective of this work was to assess differences in 18F-FDG dose coefficient estimations using a patient-dependent dosimetry paradigm, in comparison to standard one-size-fits-all reference dosimetry. We therefore calculated dosimetry estimates across a series of current-generation mesh patient-dependent phantoms to evaluate the differences arising from anatomic variability. We also investigated differences due to phantom format by comparing dose coefficients derived using the mesh reference phantoms with those obtained using stylized reference phantoms, voxel reference phantoms, or hybrid reference phantoms.

MATERIALS AND METHODS

Biokinetic Data for 18F-FDG

Biokinetic data for 18F-FDG, in the form of time-integrated activity coefficients (TIACs) (23) for the brain, heart wall, lungs, liver, urinary bladder contents, and rest of body, were obtained from the ICRP 128 (7) radiopharmaceutical data compendium (Table 1). The TIAC for the lung region provided in ICRP 128 applies to both lungs jointly; however, in the mesh phantoms, the lungs are modeled as separate regions, with each requiring an input TIAC. Therefore, the lung TIAC was divided between the right and left lung regions by mass fraction (relative to the total lung mass). Similarly, the rest-of-body TIAC was divided among the regions it comprises by tissue mass fraction (relative to the total tissue mass of the rest of the body).

View this table:
  • View inline
  • View popup
TABLE 1

ICRP 128 Reference Organ TIACs Used in Present Study

Absorbed Dose Calculations with Reference- and Patient-Dependent Mesh Phantoms

Absorbed dose coefficients (in units of mGy/MBq administered activity) for the explicitly defined mesh reference and percentile-specific phantom regions were computed by direct Monte Carlo simulation using the Particle and Heavy Ion Transport Code System (PHITS) (c)–based (14) PHITS Application for Radionuclide Dosimetry in Meshes (PARaDIM) software (17). Each simulation was configured using the multisource absorbed dose mode of PARaDIM, which generates both region-level mean absorbed dose coefficients and a 3-dimensional voxelized dose map (here, sampled at 1.0-cm isotropic spatial resolution). The material surrounding the phantom was defined as void. In total, 107 histories were simulated for each phantom. PARaDIM defaults for physical models were used, which specified the PHITS–electron γ-shower 5 method for treatment of multiple scattering, explicit treatment of fluorescent x-rays, consideration of Rayleigh and incoherent scattering, and consideration of electron-impact ionization. Sampling was used for determination of bremsstrahlung polar angles, pair electron polar angles, and distribution of photoelectrons. Cutoff energies of 1.0 keV were used for both positrons and photons.

The ICRP defines several target regions that comprise multiple uniquely defined target regions within the phantoms (e.g., lungs, comprising left and right lung; kidneys, comprising left and right renal pelvis, cortex, and medulla). The mean dose to such regions was computed as a mass-weighted combination of absorbed doses to each subregion: Embedded Image Eq. 1 where Embedded Image is the absorbed dose coefficient for a multiregion target mreg; Embedded Image is the mass of a region Embedded Image comprising the multiregion target; Embedded Image is the total mass of the multiregion target; and Embedded Image is the absorbed dose coefficient for a subregion.

The active marrow and endosteum are implicitly defined within the spongiosa and marrow cavity regions of the mesh reference and percentile-specific phantoms; the absorbed dose coefficients for these specific tissues were derived from those for the corresponding spongiosa and marrow cavities per the recommendations in ICRP 116, namely: Embedded Image Eq. 2 Embedded Image Eq. 3 where Embedded Image and Embedded Image are the skeletal-averaged absorbed dose coefficients for the active marrow and endosteal cells, respectively; Embedded Image and Embedded Image are the masses of these tissues in skeletal target region Embedded Image; Embedded Image and Embedded Image are the total masses of active marrow and endosteal cells contained within the entire skeleton; and Embedded Image and Embedded Image are the absorbed dose coefficients for the spongiosa and medullary marrow regions that encompass the active marrow and endosteal cells in skeletal region Embedded Image.

The effective dose quantity is derived from absorbed dose calculations and is a widely used concept in diagnostic radiation dosimetry; it provides a strategy for combining the variable organ doses into a single stochastic risk-relevant number (24–26). Effective dose coefficients (27) were computed using the methodology and tissue-specific weighting factors promulgated in ICRP 103 and ICRP 133, namely: Embedded Image Eq. 4 where e is the effective dose coefficient, Embedded Image is the tissue-specific weighting factor for tissue T, and Embedded Image is the radiation weighting factor for radiation type R (here, taken as unity for 18F positrons and photons).

By definition, the effective dose is relevant only for the reference person (i.e., it does not formally apply to height, weight, or otherwise constrained subsets of the patient population) (23,24). It is also restricted to the use of sex-averaged organ absorbed doses as per Equation 4. To gain insight into a similar single-value risk characterization, a related quantity—the detriment-weighted dose (28–30)—has been previously introduced; this quantity applies ICRP tissue and radiation weighting factors but removes the requirement of sex-averaging of organ absorbed doses, as well as the restriction of nonreference phantom dose values. The detriment-weighted dose provides a basis for consideration of risk from stochastic effects of radiation, as relevant to population subsets (as used here) or potentially individuals, and is used with the justification that absorbed dose, not patient geometry, is the relevant seat for quantifying risk: Embedded Image Eq. 5 where Embedded Image is the detriment-weighted dose coefficient for a phantom of sex S, height H, and total-body mass M.

Absorbed Dose Calculations with Reference Voxel, Stylized, and Hybrid Phantoms

The ICRP 89 adult male and female hybrid reference phantoms (18) were used in OLINDA 2.1. The adult male and female stylized reference phantoms were used in OLINDA 1.1, and the ICRP 110 adult voxel reference phantoms were used in IDAC-Dose 2.1 software. The default organ masses were used for each phantom in all software. Further details on the phantoms used are provided in Table 2.

View this table:
  • View inline
  • View popup
TABLE 2

Characteristics of Phantoms as Implemented in Software Used in Present Study

Hardware and Software Specification

An HP Z8 workstation running the Microsoft Windows 10 operating system and using a 3.6-GHz Intel Xeon 5122 processor was used for all Monte Carlo calculations.

3D Slicer (version 4.11; www.slicer.org) was used for dose map visualization, and Paraview (version 5.6.2; www.paraview.org) was used for 3-dimensional rendering of phantom geometry. Statistical analysis was performed with GraphPad Prism (version 8.3.1; GraphPad Software, Inc.).

RESULTS

Figure 2 shows voxel-level absorbed dose coefficients for the mesh reference and percentile-specific phantom series. These 3-dimensional dose maps are volume-rendered as maximum-intensity projections, and as they were derived under the assumption of uniformly distributed activity within whole organs, they are intended to reflect spatial nonuniformity of dose deposition averaged across a patient subpopulation matching the specified height and weight. Region-level mean absorbed dose coefficients for selected target organs of the phantoms are presented in Figures 3 and 4. A comprehensive list of dose coefficients for all defined target regions is provided in Supplemental Tables 1–8 (supplemental materials are available at http://jnm.snmjournals.org). The highest absorbed dose coefficients were observed in the heart wall, followed by the urinary bladder wall and brain, for the male and female mesh phantoms and their voxel analogs implemented in IDAC-Dose 2.1 (Fig. 5). In contrast, the urinary bladder wall was identified as the critical organ in the stylized and hybrid reference phantom dose estimates, with the bladder wall absorbed dose coefficients being approximately 2-fold higher than those for the heart wall (the next most irradiated tissue) and were approximately 2.5-fold higher than estimated with the mesh reference phantoms. This discrepancy has been noted previously (17), and here, was the largest relative deviation in the dose coefficient estimated by the mesh reference phantoms in comparison to the corresponding stylized and hybrid phantom estimates. The disagreement can be partially explained by the methodology applied for determination of specific absorbed fractions used in derivation of self-irradiation S values (and correspondingly, absorbed dose coefficients) for the urinary bladder of the stylized phantoms (31,32). Absorbed dose coefficients for the basal cell layer of the urinary bladder of the mesh reference adults (0.089 mGy/MBq and 0.091 mGy/MBq for adult male and female, respectively; Supplemental Tables 1 and 2) were more consistent with the stylized and hybrid phantom bladder dose estimates.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Voxel-level absorbed dose coefficients for 18F-FDG. (A) Adult female reference and percentile-specific phantom series juxtaposed with maximum-intensity projections of their corresponding 18F-FDG voxel dose coefficient maps. (B) Same as A but for adult male. Hx = xth percentile standing height; Wy = yth weight percentile within preceding standing height percentile.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

(A) Organ-level absorbed dose coefficients for 18F-FDG for female mesh reference computational phantom (MRCP) and comparison with percentile-specific phantom series. (B) Percentile specific dose coefficients presented as fractional differences relative to reference female. Hx = xth percentile standing height; Wy = yth weight percentile within preceding standing height percentile.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

(A) Organ-level absorbed dose coefficients for 18F-FDG for male mesh reference computational phantom and comparison with percentile-specific phantom series. (B) Percentile-specific dose coefficients presented as fractional differences relative to reference male. Hx = xth percentile standing height; MRCP = mesh reference computational phantom; Wy = yth weight percentile within preceding standing height percentile.

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

Comparison of organ-level dosimetry computed with reference phantoms in modern and legacy dosimetry software. Note overall improved agreement between mesh reference adults and output of IDAC-Dose 2.1, where anatomically equivalent phantoms were represented by different formats (i.e., mesh vs. voxel). MRCP = mesh reference computational phantom.

Relative to the reference mesh phantoms of the corresponding sex, absorbed dose coefficients for most target organs of the percentile-specific phantom series deviated by 20%–30% for the 10th and 90th weight percentile extremes. The reference and percentile-specific estimates converged near the 50th standing-height percentile/50th weight percentile within the 50th standing-height percentile; this finding was expected because of the similar body morphometry of the reference phantoms (176.0 cm/73 kg male; 163 cm/60.0 kg female) and the 50th standing-height percentile/50th weight percentile within the 50th standing-height percentile analogs (176.5 cm/79.3 kg male; 163.3 cm/64.1 kg female). Of all target tissues, absorbed dose coefficients for the brain varied the least (in relative terms) among phantoms of the same sex, primarily because of the weak dependence of brain mass on body morphometry—particularly, body mass for a given height.

The effective dose coefficient was calculated as 0.017 mSv/MBq using the male and female mesh reference phantoms in combination with the tissue-specific weighting factors of ICRP 103. This represents an approximately 10% decrease relative to the ICRP 128 estimate of 0.019 mSv/MBq and reflects geometric differences in the phantoms, tissue-specific weighting factors (Table 2), and lack of sex-averaging of the ICRP 128 organ doses used to derive the effective dose. The effective dose coefficient for the ICRP 110 voxel phantoms was 0.016 mSv/MBq (sex-averaged), which agrees within approximately 5% with the mesh reference phantom estimates; of note, these phantoms were designed to represent identical geometry but in different formats.

The detriment-weighted dose coefficient for each of the percentile-specific phantoms was computed by applying ICRP 103 tissue-specific weighting factors directly to the associated tissue equivalent dose coefficients (i.e., not using reference male/female equivalent dose averaging; Eq. 5). The patient dependence of the detriment-weighted dose is provided in Figure 6 for the percentile-specific phantoms. Though the relationships depend on height, weight, sex, and underlying physical factors (linear energy transfer, attenuation), the detriment-weighted dose negatively correlates strongly with body mass (Spearman r = −0.9505; P < 0.0001) but less strongly with BMI (Spearman r = −0.7049; P = 0.0011). Notably, given a particular sex, the detriment-weighted dose-versus-mass curves for different height classifications were observed to decrease monotonically. For a given mass, detriment-weighted dose coefficients for females were larger than for males. Together, these results suggest that consideration of body morphometry, rather than only body mass, will further improve dose estimates and optimization strategies.

FIGURE 6.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 6.

Dependence on body mass (A), and dependence on body mass index (BMI) (B), of detriment-weighted dose coefficients (eDW) for male and female percentile-specific phantom series. Hx = xth percentile standing height; Wy = yth weight percentile within preceding standing height percentile.

DISCUSSION

Diagnostic dose measurement has roles in optimization, comparison of techniques and modalities, quality assurance, research and development, and support of regulatory standards and public health protection (24). Understanding the variability and uncertainty in dose estimates is of heightened importance considering repeat oncologic imaging sessions in which uncertainties must be propagated across multiple imaging sessions throughout disease management. The contributing factors for uncertainty in organ-level absorbed dose calculations (33–35) can include uncertainty in radionuclide physical decay data, system calibration, Monte Carlo calculation of energy deposition, body morphometry of the patient in comparison to the phantom representing the patient, and radiopharmaceutical biokinetics and intraorgan distribution. Of these, the uncertainty in radionuclide decay data is negligible in most cases, and uncertainty in Monte Carlo simulations can be minimized with adequate sampling. In contrast, body morphometry and radiopharmaceutical biokinetics and intraorgan distribution represent the principal organ-level dosimetric uncertainties.

Our study addresses uncertainty and variability in body morphometry for specific subsets of the Caucasian patient population, and we provide patient-dependent dose estimates (with a broad approximation of the anatomy of height- and weight-defined subsets of the patient population), in contrast to patient-specific calculations (which account for the unique anatomy of a specific patient) (22). In doing so, we have used reference 18F-FDG biokinetic data in order to ensure that the variability in the results originates plainly from the underlying anatomic differences. The biokinetics of 18F-FDG may vary across patients, such as because of dietary conditions, presence of tumors, and kidney dysfunction. To our knowledge, the biokinetic dependence on adult body morphometry has not been comprehensively investigated. Considering the uncertainty in biokinetics, as well as the impracticality of creating patient-specific phantoms for routine imaging procedures, there is some rationale for applying these dose estimates to specific patients by matching them to the appropriate height and weight percentiles. Such strategies could support scan-specific dose reporting in nuclear medicine in the near future.

Role of Patient-Dependent Dose Coefficients in Diagnostic Nuclear Medicine

Optimization strategies for 18F-FDG should continue to prioritize the delivery of images of diagnostic quality. The Image Wisely and Image Gently initiatives (4,5) espouse safe and efficacious imaging by striving to deliver diagnostic images while maintaining radiation doses as low as reasonably achievable. Our calculations provide supporting data for patient size–based 18F-FDG administration and related optimization strategies. At 18F-FDG dose levels expected clinically, the CIs in risk–dose relationships are currently too broad to justify the consideration of risk in management of individual patients (36,37). Therefore, the dose coefficients we have provided should be used primarily for improved scan-specific dose reporting, which will enable better elucidation of dose–risk relationships in epidemiologic studies. Incorporating patient size–dependent variation in 18F-FDG biokinetics would allow further refinement of the present dose coefficient estimates and would allow them to be more confidently used in setting guidelines for administered activity as a function of adult body morphometry. A greater impact of morphometry-dependent variation in absorbed dose and detriment-weighted dose coefficients can be expected with longer-half-life diagnostic radiopharmaceuticals.

Methodologic Considerations

In contrast to the orthodox method of computing dose coefficients from specific absorbed fraction–derived S-value lookup tables, here we have computed task-specific dose coefficients via direct Monte Carlo simulation. The derivation of a complete set of phantom organ–specific absorbed fractions requires a monumental computational effort. For example, ICRP 133 provides specific absorbed fractions for the ICRP 110 series of adult phantoms in 79 unique source regions across 3 corpuscular radiation types plus photons, and approximately 20 discrete energies are necessary for interpolation—effectively requiring over 6,000 individual Monte Carlo simulations per phantom—but thereafter enabling dose from any radionuclide or biokinetic dataset to be immediately computed. For the direct approach used here, a single phantom requires a new Monte Carlo simulation for every biokinetic dataset, but the simulation can be run on a standard desktop computer on a clinically acceptable timescale. Thus, future availability of specific absorbed fractions for the mesh reference–specific and percentile-specific phantoms will increase flexibility and computation speed, but their current unavailability should not present a barrier to implementation of these phantoms.

Some organ-level dosimetry software, including OLINDA, allows users to modify reference phantom organ masses to approximate patient-specific dose calculations. These approaches typically involve linearly scaling the self-S contributions from weakly penetrating radiations (α-particles and electrons) with inverse mass, whereas photon self-S contributions are scaled inversely with the two-thirds power of the mass (32). This approach assumes that source–target proximity is invariant on changes in organ mass or patient shape. This approach is reasonable when the phantom already recapitulates the salient morphometry of the patient or patient population subset (e.g., for small mass variation in larger spheric organs) but may be subject to considerable errors when, for example, scaling reference phantom S values to match patients of much smaller or much larger overall size. As the percentile-specific phantoms account for gross size variation across patients, they would serve as a better basis for patient-specific organ S-value scaling.

CONCLUSION

Using newly developed computational phantoms, we provide patient-dependent dose coefficients and revised reference dose coefficients for 18F-FDG. Differences in patient morphometry imparted large deviations in dose coefficients for the upper and lower 10th percentile extremes of patient height and weight (up to ±40% relative to the reference patient). Although our work was limited to 18F-FDG, greater impact is expected for longer-lived isotopes in imaging. These data pertain to stochastic risk estimates and should not be used for individual patient management, but the methodology described may support optimization of administered activities in clinical practice.

DISCLOSURE

This research was funded in part through the NIH/NCI Cancer Center support grant P30 CA008748 and by NIH U01 EB028234. Lukas Carter acknowledges support from the Ruth L. Kirschstein NRSA Postdoctoral Fellowship (NIH F32 EB025050). Simone Krebs was supported in part by the NIH/NCI Paul Calabresi Career Development Award for Clinical Oncology (K12 CA184746). No other potential conflict of interest relevant to this article was reported.

ACKNOWLEDGMENTS

We are enormously grateful for technical support from the PHITS team of the Japanese Atomic Energy Administration, including Drs. Tatsuhiko Sato and Takuya Furuta.

KEY POINTS

QUESTION: Can the influence of patient size on 18F-FDG dosimetry be elucidated using newly developed patient-dependent phantoms?

PERTINENT FINDINGS: Dose coefficients for 18F-FDG were shown to vary by up to ±40% across the 10th–90th percentiles for standing height and weight across the Caucasian adult patient population.

IMPLICATIONS FOR PATIENT CARE: Implementation of the current state-of-the-art phantom libraries into modernized dosimetry software will foster greater accuracy in dosimetry and ultimately support optimized strategies for personalized nuclear medicine.

Footnotes

  • Published online April 16, 2021.

  • © 2021 by the Society of Nuclear Medicine and Molecular Imaging.

REFERENCES

  1. 1.↵
    2020 PET Imaging Market Summary Report. IMV; 2020.
  2. 2.↵
    Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2. National Academies Press; 2006:2.
  3. 3.↵
    ICRP publication 103: The 2007 Recommendations of the International Commission on Radiological Protection. Ann ICRP. 2007;37:43.
  4. 4.↵
    1. Brink JA,
    2. Amis ES.
    Image Wisely: a campaign to increase awareness about adult radiation protection. Radiology. 2010;257:601–602.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Applegate KE,
    2. Cost NG.
    Image Gently: a campaign to reduce children’s and adolescents’ risk for cancer during adulthood. J Adolesc Health. 2013;52(suppl):S93–S97.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Sgouros G,
    2. Frey EC,
    3. Bolch WE,
    4. Wayson MB,
    5. Abadia AF,
    6. Treves ST.
    An approach for balancing diagnostic image quality with cancer risk: application to pediatric diagnostic imaging of 99mTc-dimercaptosuccinic acid. J Nucl Med. 2011;52:1923–1929.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. Mattsson S,
    2. Johansson L,
    3. Leide Svegborn S,
    4. et al
    . Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances. Ann ICRP. 2015;44:7–321.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Cristy M,
    2. Eckerman KF.
    Specific Absorbed Fractions of Energy at Various Ages from Internal Photon Sources: 7, Adult Male. Oak Ridge National Laboratory; 1987.
  9. 9.↵
    1. Snyder WS,
    2. Fisher HL,
    3. Ford MR,
    4. Warner GG.
    Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. J Nucl Med. 1969;10(suppl 3):7–52.
    OpenUrl
  10. 10.↵
    ICRP publication 23: Report of the Task Group on Reference Man. Pergamon Press; 1975.
  11. 11.↵
    1. Zubal IG,
    2. Harrell CR,
    3. Smith EO,
    4. Rattner Z,
    5. Gindi G,
    6. Hoffer PB.
    Computerized three-dimensional segmented human anatomy. Med Phys. 1994;21:299–302.
    OpenUrlCrossRefPubMed
  12. 12.
    1. Zaidi H,
    2. Xu XG.
    Computational anthropomorphic models of the human anatomy: the path to realistic Monte Carlo modeling in radiological sciences. Annu Rev Biomed Eng. 2007;9:471–500.
    OpenUrlCrossRefPubMed
  13. 13.
    1. Geyer AM,
    2. O’Reilly S,
    3. Lee C,
    4. Long DJ,
    5. Bolch WE.
    The UF/NCI family of hybrid computational phantoms representing the current US population of male and female children, adolescents, and adults: application to CT dosimetry. Phys Med Biol. 2014;59:5225–5242.
    OpenUrl
  14. 14.↵
    1. Sato T,
    2. Iwamoto Y,
    3. Hashimoto S,
    4. et al
    . Features of Particle and Heavy Ion Transport code System (PHITS) version 3.02. J Nucl Sci Technol. 2018;55:684–690.
    OpenUrl
  15. 15.
    1. Furuta T,
    2. Sato T,
    3. Han MC,
    4. et al
    . Implementation of tetrahedral-mesh geometry in Monte Carlo radiation transport code PHITS. Phys Med Biol. 2017;62:4798–4810.
    OpenUrl
  16. 16.
    1. Agostinelli S,
    2. Allison J,
    3. Amako K,
    4. et al
    . Geant4: a simulation toolkit. Nucl Instrum Methods Phys Res A. 2003;506:250–303.
    OpenUrlCrossRef
  17. 17.↵
    1. Carter LM,
    2. Crawford TM,
    3. Sato T,
    4. et al
    . PARaDIM: a PHITS-based Monte Carlo tool for internal dosimetry with tetrahedral mesh computational phantoms. J Nucl Med. 2019;60:1802–1811.
    OpenUrlAbstract/FREE Full Text
  18. 18.↵
    1. Stabin MG,
    2. Xu XG,
    3. Emmons MA,
    4. Segars WP,
    5. Shi C,
    6. Fernald MJ.
    RADAR reference adult, pediatric, and pregnant female phantom series for internal and external dosimetry. J Nucl Med. 2012;53:1807–1813.
    OpenUrlAbstract/FREE Full Text
  19. 19.↵
    1. Kim CH,
    2. Yeom YS,
    3. Petoussi-Henss N,
    4. et al
    . ICRP publication 145: adult mesh-type reference computational phantoms. Ann ICRP. 2020;49:13–201.
    OpenUrl
  20. 20.↵
    1. Cassola VF,
    2. Milian FM,
    3. Kramer R,
    4. de Oliveira Lira CAB,
    5. Khoury HJ.
    Standing adult human phantoms based on 10th, 50th and 90th mass and height percentiles of male and female Caucasian populations. Phys Med Biol. 2011;56:3749–3772.
    OpenUrlPubMed
  21. 21.↵
    1. Lee H,
    2. Yeom YS,
    3. Nguyen TT,
    4. et al
    . Percentile-specific computational phantoms constructed from ICRP mesh-type reference computational phantoms (MRCPs). Phys Med Biol. 2019;64:045005.
    OpenUrl
  22. 22.↵
    1. Bolch W,
    2. Lee C,
    3. Wayson M,
    4. Johnson P.
    Hybrid computational phantoms for medical dose reconstruction. Radiat Environ Biophys. 2010;49:155–168.
    OpenUrlCrossRefPubMed
  23. 23.↵
    1. Bolch WE,
    2. Eckerman KF,
    3. Sgouros G,
    4. Thomas SR.
    MIRD pamphlet no. 21: a generalized schema for radiopharmaceutical dosimetry—standardization of nomenclature. J Nucl Med. 2009;50:477–484.
    OpenUrlAbstract/FREE Full Text
  24. 24.↵
    1. Martin CJ,
    2. Harrison JD,
    3. Rehani MM.
    Effective dose from radiation exposure in medicine: past, present, and future. Phys Med. 2020;79:87–92.
    OpenUrlPubMed
  25. 25.
    1. Harrison JD,
    2. Balonov M,
    3. Bochud F,
    4. et al
    . ICRP publication 147: use of dose quantities in radiological protection. Ann ICRP. 2021;50:9–82.
    OpenUrl
  26. 26.↵
    1. Harrison JD,
    2. Balonov M,
    3. Bochud F,
    4. et al
    . The use of dose quantities in radiological protection: ICRP publication 147 Ann ICRP 50(1) 2021. J Radiol Prot. 2021;41:410.
  27. 27.↵
    1. Bolch WE,
    2. Jokisch D,
    3. Zankl M,
    4. et al
    . ICRP publication 133: the ICRP computational framework for internal dose assessment for reference adults: specific absorbed fractions. Ann ICRP. 2016;45:5–73.
    OpenUrlCrossRefPubMed
  28. 28.↵
    1. Kofler C,
    2. Domal S,
    3. Satoh D,
    4. Dewji S,
    5. Eckerman K,
    6. Bolch WE.
    Organ and detriment-weighted dose rate coefficients for exposure to radionuclide-contaminated soil considering body morphometries that differ from reference conditions: adults and children. Radiat Environ Biophys. 2019;58:477–492.
    OpenUrl
  29. 29.
    1. Brown JL,
    2. Sexton-Stallone B,
    3. Li Y,
    4. et al
    . Body morphometry appropriate computational phantoms for dose and risk optimization in pediatric renal imaging with Tc-99m DMSA and Tc-99m MAG3. Phys Med Biol. 2020;65:235026.
    OpenUrl
  30. 30.↵
    1. Brown J,
    2. Sexton-Stallone B,
    3. Li Y,
    4. et al
    . Dosimetric considerations of Tc-99m MDP uptake within the epiphyseal plates of the long bones of pediatric patients. Phys Med Biol. 2020;65:235025.
    OpenUrl
  31. 31.↵
    1. Stabin MG.
    MIRDOSE: personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 1996;37:538–546.
    OpenUrlFREE Full Text
  32. 32.↵
    1. Stabin MG,
    2. Sparks RB,
    3. Crowe E.
    OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–1027.
    OpenUrlAbstract/FREE Full Text
  33. 33.↵
    1. Stabin MG.
    Uncertainties in internal dose calculations for radiopharmaceuticals. J Nucl Med . 2008;49:853–860.
    OpenUrlAbstract/FREE Full Text
  34. 34.
    1. Gear JI,
    2. Cox MG,
    3. Gustafsson J,
    4. et al
    . EANM practical guidance on uncertainty analysis for molecular radiotherapy absorbed dose calculations. Eur J Nucl Med Mol Imaging. 2018;45:2456–2474.
    OpenUrl
  35. 35.↵
    1. Zvereva A,
    2. Kamp F,
    3. Schlattl H,
    4. Zankl M,
    5. Parodi K.
    Impact of interpatient variability on organ dose estimates according to MIRD schema: uncertainty and variance-based sensitivity analysis. Med Phys. 2018;45:3391–3403.
    OpenUrl
  36. 36.↵
    1. Weber W,
    2. Zanzonico P.
    The controversial linear no-threshold model. J Nucl Med. 2017;58:7–8.
    OpenUrlFREE Full Text
  37. 37.↵
    1. Siegel JA,
    2. Pennington CW,
    3. Sacks B.
    Subjecting radiologic imaging to the linear no-threshold hypothesis: a non sequitur of non-trivial proportion. J Nucl Med. 2017;58:1–6.
    OpenUrlAbstract/FREE Full Text
  38. 38.
    1. Stabin MG,
    2. Emmons MA,
    3. Segars WP,
    4. Fernald MJ.
    Realistic reference adult and paediatric phantom series for internal and external dosimetry. Radiat Prot Dosimetry. 2012;149:56–59.
    OpenUrlCrossRefPubMed
  39. 39.
    1. Menzel H-G,
    2. Clement C,
    3. DeLuca P.
    ICRP publication 110: realistic reference phantoms—an ICRP/ICRU joint effort: a report of adult reference computational phantoms. Ann ICRP. 2009;39:1–164.
    OpenUrlPubMed
  40. 40.
    1. Andersson M,
    2. Johansson L,
    3. Eckerman K,
    4. Mattsson S.
    IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms. EJNMMI Res. 2017;7:88.
    OpenUrl
  • Received for publication September 10, 2020.
  • Revision received March 16, 2021.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 62 (12)
Journal of Nuclear Medicine
Vol. 62, Issue 12
December 1, 2021
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Patient Size-Dependent Dosimetry Methodology Applied to 18F-FDG Using New ICRP Mesh Phantoms
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Patient Size-Dependent Dosimetry Methodology Applied to 18F-FDG Using New ICRP Mesh Phantoms
Lukas M. Carter, Chansoo Choi, Simone Krebs, Bradley J. Beattie, Chan Hyeong Kim, Heiko Schoder, Wesley E. Bolch, Adam L. Kesner
Journal of Nuclear Medicine Dec 2021, 62 (12) 1805-1814; DOI: 10.2967/jnumed.120.256719

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Patient Size-Dependent Dosimetry Methodology Applied to 18F-FDG Using New ICRP Mesh Phantoms
Lukas M. Carter, Chansoo Choi, Simone Krebs, Bradley J. Beattie, Chan Hyeong Kim, Heiko Schoder, Wesley E. Bolch, Adam L. Kesner
Journal of Nuclear Medicine Dec 2021, 62 (12) 1805-1814; DOI: 10.2967/jnumed.120.256719
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • ACKNOWLEDGMENTS
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • MIRD Pamphlet No. 28, Part 1: MIRDcalc--A Software Tool for Medical Internal Radiation Dosimetry
  • Google Scholar

More in this TOC Section

  • [11C]ZTP-1: An Effective Short-Lived Radioligand for PET of Rat and Monkey Brain Phosphodiesterase Type 4 Subtype B
  • Reduced Renal Uptake of Various Radiopharmaceuticals with Sodium Paraaminohippurate Coadministration in a Rat Model
  • In Vivo Visualization and Quantification of Brain Heat Shock Protein 90 with [11C]HSP990 in Healthy Aging and Neurodegeneration
Show more Basic Science Investigation

Similar Articles

Keywords

  • FDG
  • patient-dependent dosimetry
  • PARaDIM
  • PHITS
  • phantom
SNMMI

© 2025 SNMMI