Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleFocus on Molecular Imaging

Imaging Microglial Activation with TSPO PET: Lighting Up Neurologic Diseases?

Lucy Vivash and Terence J. O’Brien
Journal of Nuclear Medicine February 2016, 57 (2) 165-168; DOI: https://doi.org/10.2967/jnumed.114.141713
Lucy Vivash
Department of Medicine, Royal Melbourne Hospital, University of Melbourne, Royal Parade, Parkville, Victoria, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Terence J. O’Brien
Department of Medicine, Royal Melbourne Hospital, University of Melbourne, Royal Parade, Parkville, Victoria, Australia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Neuroinflammation is implicated in the pathogenesis of a wide range of neurologic and neuropsychiatric diseases. For over 20 years, 11C-PK11195 PET, which aims to image expression of the translocator protein (TSPO) on activated microglia in the brain, has been used in preclinical and clinical research to investigate neuroinflammation in vivo in patients with brain diseases. However, 11C-PK11195 suffers from two major limitations: its low brain permeability and high nonspecific and plasma binding results in a low signal-to-noise ratio, and the use of 11C restricts its use to PET research centers and hospitals with an on-site cyclotron. In recent years, there has been a great deal of work into the development of new TSPO-specific PET radiotracers. This work has focused on fluorinated radiotracers, which would enable wider use and improved signal-to-noise ratios. These radiotracers have been utilized in preclinical and clinical studies of several neurologic diseases with varying degrees of success. Unfortunately, the application of these second-generation TSPO radiotracers has revealed additional problems, including a polymorphism that affects TSPO binding. In this review, the developments in TSPO imaging are discussed, and current limitations and suggestions for future directions are explored.

  • positron emission tomography
  • TSPO
  • microglia
  • neurology
  • 11C-PK11195

The translocator protein (TSPO), originally designated the peripheral benzodiazepine receptor, is an 18-kDa protein found on the outer mitochondrial membrane. TSPO is expressed in a variety of tissues throughout the body but is prominently upregulated with inflammation. In the healthy brain there is low TSPO expression on microglia, the primary immune cells in the central nervous system. However, when microglia are activated in response to an injury, TSPO expression is markedly upregulated. As a result, the expression of TSPO has been considered a marker of neuroinflammation, and its increased brain expression is associated with numerous neurologic diseases (1). For this reason, imaging expression of TSPO with PET has been developed as a potentially clinically applicable tool for in vivo imaging of the patterns of neuroinflammation. TSPO PET imaging holds promise both for increasing understanding of the role of neuroinflammation in brain diseases and as a tool for assessing the efficacy of novel therapies. The structure and pharmacology of TSPO have been reviewed in detail by Scarf and Kassiou (2).

11C-PK11195

The most widely used TSPO PET tracer has been 11C-PK11195, an isoquinoline carboxamide that is a selective antagonist for TSPO. 11C-PK11195 was initially used as a racemate, but later studies found that the R-enantiomer binds with a 2-fold greater affinity than the S-enantiomer. Therefore, subsequent studies have utilized 11C-(R)-PK11195 PET to investigate neuroinflammation in several neurologic and neurooncologic diseases (3).

However, several major limitations have restricted the widespread use of 11C-PK11195 in the imaging of neuroinflammation in research and clinical practice. First, 11C-PK11195 has relatively low brain permeability and high nonspecific and plasma protein binding, which result in a low signal-to-noise ratio and low specificity in PET images. This means that 11C-PK11195 PET is not able to detect subtle alterations in neuroinflammation or to accurately track temporal changes in neuroinflammation. Second, the use of the short-half-life 11C as the radioisotope restricts use of the radiotracer to PET centers with an on-site cyclotron. Thus, recent studies have focused on the development of fluorinated (18F) TSPO radiotracers, which have the advantage of a longer half-life and therefore do not require an on-site cyclotron, improving accessibility of the radioisotope to researchers and clinicians, considerably reducing costs, and improving signal-to-noise ratios.

SECOND- AND THIRD-GENERATION TSPO RADIOTRACERS IN NEUROLOGIC DISEASES

After the synthesis of multiple different fluorinated TSPO-specific radiotracers (Table 1 (4)), numerous preclinical and early clinical studies were conducted on a range of neurologic and oncologic diseases. Preclinical studies on rat glioma models have shown high uptake of 18F-PBR06 and 18F-DPA714 in tumor compared with the contralateral hemisphere (5,6). Both tracers have shown a high degree of specific binding to TSPO (75% displaceable binding for 18F-PBR06, 60% for 18F-DPA714). However, TSPO imaging is unable to differentiate expression on tumor cells from expression on inflammatory cells surrounding the tumor—a major limitation for the clinical application of TSPO imaging of brain tumors.

View this table:
  • View inline
  • View popup
TABLE 1

A Summary of the Newer Generation of TSPO Radiotracers

TSPO expression has also been investigated using PET in preclinical and clinical studies of Alzheimer disease. Microglial activation has been observed in mouse models of Alzheimer disease and in patients (7,8). However, it has yet to be firmly established whether the microglial activation observed corresponds with amyloid or tau distribution or represents an independent pathologic distribution. Further, other clinical studies have failed to differentiate Alzheimer disease patients from age-matched controls (9,10). This disparity indicates the importance of trialing a variety of radiotracers for appropriate sensitivity and specificity.

TSPO PET imaging has also been used by stroke researchers to investigate the role and time course of neuroinflammation after an acute cerebral infarction. Numerous TSPO-specific radiotracers have been used to image the core and periinfarct region in rat models of ischemia, demonstrating specific uptake in the region of an ischemic infarct, in agreement with ex vivo autoradiography studies (11). In patients, increased uptake of the tracer 11C-vinpocetine has been observed in both the infarct region and the periinfarct region compared with the contralateral hemisphere (12). Uptake of 11C-vinpocetine was higher than that of 11C-PK11195 and, unlike 11C-PK11195, was also able to differentiate the infarct from the periinfarct region (with greater uptake observed in the periinfarct region than in the infarct). However, the authors commented on the low affinity of 11C-vinpocetine for TSPO, which may limit its future clinical use.

Possibly the greatest clinical opportunity for in vivo imaging of neuroinflammation with TSPO PET is in patients with multiple sclerosis. Both acute inflammation and chronic neuroinflammation are implicated in the pathogenesis and clinical manifestation of this disease; however, this correlation has been difficult to study directly because of a lack of methods to assess neuroinflammation in vivo in humans. Therapies for patients with multiple sclerosis are directed against aspects of the inflammatory process, and therefore an accurate, clinically applicable tool to measure neuroinflammation could provide a valuable biomarker to assess the efficacy of treatment against disease progression. Such a biomarker would have great value both in drug development and in managing the treatment of individual patients. To date, a small number of preclinical and clinical studies have been reported. In the experimental autoimmune encephalomyelitis animal model, spinal TSPO expression has been imaged using numerous different PET radiotracers. When the radiotracers 11C-DAC and 18F-GE180 were used with PET, increased TSPO expression was observed in the brains of these mice, compared with controls, and this expression was shown to correlate with expression on ex vivo autoradiography and immunohistochemistry studies (13). Importantly, after treatment with immunosuppressant drugs, radiotracer uptake was greatly reduced, indicating the future use of TSPO PET as a noninvasive biomarker for evaluating and monitoring the effect of multiple sclerosis therapies on disease activity (13,14). Clinical studies on patients with multiple sclerosis have shown increased radiotracer uptake in lesional and perilesional white matter compared with nonlesional white matter using 18F-PBR111 and 11C-PBR28 but not 18F-FEDAA1106 (15–17), with radiotracer uptake shown to correlate positively with disease duration or severity, indicating potential utility for TSPO PET in monitoring disease activity.

LIMITATIONS OF NEW TSPO RADIOTRACERS

Despite studies showing promise for these newer TSPO radiotracers, significant issues have emerged that may limit the application of these tracers for routine clinical use. Early work using 11C-PBR28 reported a proportion of patients who were “nonbinders,” meaning the radiotracer did not bind to TSPO. Further studies found that this nonbinder-group problem was not limited to 11C-PBR28 but affected all studied second-generation TSPO radiotracers except 11C-PK11195 (18). Three distinct binder states have been identified: high-, mixed-, and low-affinity binders (18), which have been found to be determined by a single polymorphism (rs6971) in exon 4 of the TSPO gene causing an alanine-to-threonine substitution (19). The presence of the predominant form, Ala/Ala, is associated with high-affinity binding, whereas Ala/Thr is associated with mixed-affinity binding and Thr/Thr with low-affinity binding. Initially identified using nonradiolabeled PBR28 (19), this polymorphism has also been confirmed for 18F-PBR111 (Fig. 1 (20)). Importantly, this polymorphism (and consequently binder status) can be identified by genetic analysis of leukocytes, allowing stratification of subjects, and can subsequently account for binder status in quantitation of TSPO PET studies using second-generation radiotracers. However, in those patients who are low-affinity binders, TSPO PET images are of significantly lower quality, and the clinical usefulness of this approach is therefore limited in these patients.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Parametric maps of 18F-PBR111 volume of distribution in high-, mixed-, and low-affinity binders as determined by genotyping for rs6971 polymorphism. HAB = high-affinity binder; LAB = low-affinity binder; MAB = mixed-affinity binder; VT = volume of distribution. (Reprinted from (20).)

A second concern for the value of TSPO PET imaging is lack of specificity of TSPO binding for activated microglia. TSPO is expressed on multiple different immune cells, including astrocytes, with TSPO radiotracer uptake reflecting activated astrocytes as well as activated microglia (21). Given the differing roles of microglia and astrocytes in neuroinflammatory responses, the result is a significant limitation on data interpretation and on defining the role of microglia in neurologic diseases. This lack of selectivity of TSPO radiotracers for microglia over other immune cells has led to the development of radiotracers that target alternative markers of microglial activation.

A further problem with the development of these newer-generation radiotracers is that those for which the best imaging results have been reported are 11C-labeled. However, a recent study found 11C-PBR28 and 18F-PBR06 to be comparable with respect to binding affinity and background binding, suggesting that in future studies 11C-PBR28 can be substituted for 18F-PBR06 (22).

Lastly, a common problem with PET studies is the quantification of data. Qualitative assessment of images may be useful in cases of substantial or widespread neuroinflammation but may not show subtler changes in neuroinflammation. For this reason, pharmacokinetic modeling of receptor–radiotracer kinetics is often performed, although with practical limitations for application to routine clinical practice. Pharmacokinetic modeling requires either serial arterial blood samples or a suitable reference region where the radiotracer does not bind. Recently, however, the cerebellum was validated as a reference region for 11C-PBR28-TSPO binding in Alzheimer disease patients (8), potentially circumventing the need for arterial blood sampling for quantification of receptor binding in future studies of this disease using 11C-PBR28. However, because of differences in both radiotracer pharmacokinetics and TSPO distribution in diseases, it is necessary to independently validate a reference region for each radiotracer and in each disease being studied. Further, for diseases in which neuroinflammation is more diffuse and an unaffected anatomic reference region cannot be determined, alternative quantification methods are required, such as cluster analysis for the identification of an appropriate reference region.

ALTERNATIVES TO TSPO IMAGING

A limitation of TSPO as a biomarker of neuroinflammation is its expression on multiple types of immune cells. The development of more selective biomarkers of various participants in neuroinflammatory processes, including cell types such as monocytes, b cells, t cells, and astrocytes, as well molecular mediators of neuroinflammation, which can be targeted with PET radiotracers, would be of great value to the field. 11C-ketoprofen methyl ester specifically targets cyclooxygenase 1 and has been shown to be safe and to have favorable imaging characteristics warranting further investigation (23). Similarly, 11C-RSR-056 and 11C-A-836339 have shown promise as specific radiotracers for the cannabinoid type 2 receptor (24,25).

The role of microglia in neuroinflammation is complex, with a growing body of evidence supporting two subtypes of microglia, one that is broadly neurotoxic and another that is broadly neuroprotective. Therefore, a PET radiotracer that is specific for either of these subtypes of microglia would be of great value in research and potentially in the clinic. However, there is currently no clear target that appears viable for a PET radiotracer that can distinguish between the microglia subtypes.

CONCLUSION

For in vivo TSPO imaging, an array of promising new radiotracers has been developed that overcome many of the limitations of 11C-PK11195. Recent recognition of the problem of there being various binding states for these tracers among the population has been mitigated by a simple blood test to ascertain binding status. However, there is as yet no ideal TSPO PET radiotracer for those who have genetically determined low binder status. Additional studies are required to further investigate the specificity of these radiotracers for activated microglia over other activated glial cells. More research is also required in preclinical and early clinical evaluation of these tracers, particularly those radiolabeled with 18F, in order to establish their utility as research and clinical tools. However, early studies show that these tracers promise to be valuable tools for the investigation of a variety of neurologic diseases, including stroke, Alzheimer disease, and multiple sclerosis. More widespread use of these radiotracers will enable further novel insights into the role of neuroinflammation in the pathogenesis of many neurologic, psychiatric, and oncologic diseases. Of great potential is the future use of these radiotracers as diagnostic and prognostic tools and in assessing the effects of therapeutic interventions on disease activity.

DISCLOSURE

No potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Dec. 23, 2015.

  • © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

REFERENCES

  1. 1.↵
    1. Rupprecht R,
    2. Papadopoulos V,
    3. Rammes G,
    4. et al
    . Translocator protein (18 kDa) (TSPO) as a therapeutic target for neurological and psychiatric disorders. Nat Rev Drug Discov. 2010;9:971–988.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Scarf AM,
    2. Kassiou M
    . The translocator protein. J Nucl Med. 2011;52:677–680.
    OpenUrlAbstract/FREE Full Text
  3. 3.↵
    1. Owen DR,
    2. Matthews PM
    . Imaging brain microglial activation using positron emission tomography and translocator protein-specific radioligands. Int Rev Neurobiol. 2011;101:19–39.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Trapani A,
    2. Palazzo C,
    3. de Candia M,
    4. Lasorsa FM,
    5. Trapani G
    . Targeting of the translocator protein 18 kDa (TSPO): a valuable approach for nuclear and optical imaging of activated microglia. Bioconjug Chem. 2013;24:1415–1428.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Buck JR,
    2. McKinley ET,
    3. Hight MR,
    4. et al
    . Quantitative, preclinical PET of translocator protein expression in glioma using 18F-N-fluoroacetyl-N-(2,5-dimethoxybenzyl)-2-phenoxyaniline. J Nucl Med. 2011;52:107–114.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    1. Tang D,
    2. Hight MR,
    3. McKinley ET,
    4. et al
    . Quantitative preclinical imaging of TSPO expression in glioma using N,N-diethyl-2-(2-(4-(2-18F-fluoroethoxy)phenyl)-5,7-dimethylpyrazolo[1,5-a]pyrimi din-3-yl)acetamide. J Nucl Med. 2012;53:287–294.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. James ML,
    2. Belichenko NP,
    3. Nguyen TV,
    4. et al
    . PET imaging of translocator protein (18 kDa) in a mouse model of Alzheimer’s disease using N-(2,5-dimethoxybenzyl)-2-18F-fluoro-N-(2-phenoxyphenyl)acetamide. J Nucl Med. 2015;56:311–316.
    OpenUrlAbstract/FREE Full Text
  8. 8.↵
    1. Lyoo CH,
    2. Ikawa M,
    3. Liow JS,
    4. et al
    . Cerebellum can serve as a pseudo-reference region in Alzheimer disease to detect neuroinflammation measured with PET radioligand binding to translocator protein. J Nucl Med. 2015;56:701–706.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Gulyás B,
    2. Vas A,
    3. Toth M,
    4. et al
    . Age and disease related changes in the translocator protein (TSPO) system in the human brain: positron emission tomography measurements with [11C]vinpocetine. Neuroimage. 2011;56:1111–1121.
    OpenUrlCrossRefPubMed
  10. 10.↵
    1. Varrone A,
    2. Mattsson P,
    3. Forsberg A,
    4. et al
    . In vivo imaging of the 18-kDa translocator protein (TSPO) with [18F]FEDAA1106 and PET does not show increased binding in Alzheimer’s disease patients. Eur J Nucl Med Mol Imaging. 2013;40:921–931.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Yui J,
    2. Maeda J,
    3. Kumata K,
    4. et al
    . 18F-FEAC and 18F-FEDAC: PET of the monkey brain and imaging of translocator protein (18 kDa) in the infarcted rat brain. J Nucl Med. 2010;51:1301–1309.
    OpenUrlAbstract/FREE Full Text
  12. 12.↵
    1. Gulyas B,
    2. Toth M,
    3. Vas A,
    4. et al
    . Visualising neuroinflammation in post-stroke patients: a comparative PET study with the TSPO molecular imaging biomarkers [11C]PK11195 and [11C]vinpocetine. Curr Radiopharm. 2012;5:19–28.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. Xie L,
    2. Yamasaki T,
    3. Ichimaru N,
    4. et al
    . [11C]DAC-PET for noninvasively monitoring neuroinflammation and immunosuppressive therapy efficacy in rat experimental autoimmune encephalomyelitis model. J Neuroimmune Pharmacol. 2012;7:231–242.
    OpenUrlCrossRefPubMed
  14. 14.↵
    1. Airas L,
    2. Dickens AM,
    3. Elo P,
    4. et al
    . In vivo PET imaging demonstrates diminished microglial activation after fingolimod treatment in an animal model of multiple sclerosis. J Nucl Med. 2015;56:305–310.
    OpenUrlAbstract/FREE Full Text
  15. 15.↵
    1. Colasanti A,
    2. Guo Q,
    3. Muhlert N,
    4. et al
    . In vivo assessment of brain white matter inflammation in multiple sclerosis with 18F-PBR111 PET. J Nucl Med. 2014;55:1112–1118.
    OpenUrlAbstract/FREE Full Text
  16. 16.
    1. Oh U,
    2. Fujita M,
    3. Ikonomidou VN,
    4. et al
    . Translocator protein PET imaging for glial activation in multiple sclerosis. J Neuroimmune Pharmacol. 2011;6:354–361.
    OpenUrlCrossRefPubMed
  17. 17.↵
    1. Takano A,
    2. Piehl F,
    3. Hillert J,
    4. et al
    . In vivo TSPO imaging in patients with multiple sclerosis: a brain PET study with [18F]FEDAA1106. EJNMMI Res. 2013;3:30.
    OpenUrlCrossRefPubMed
  18. 18.↵
    1. Owen DR,
    2. Gunn RN,
    3. Rabiner EA,
    4. et al
    . Mixed-affinity binding in humans with 18-kDa translocator protein ligands. J Nucl Med. 2011;52:24–32.
    OpenUrlAbstract/FREE Full Text
  19. 19.↵
    1. Owen DR,
    2. Yeo AJ,
    3. Gunn RN,
    4. et al
    . An 18-kDa translocator protein (TSPO) polymorphism explains differences in binding affinity of the PET radioligand PBR28. J Cereb Blood Flow Metab. 2012;32:1–5.
    OpenUrlAbstract/FREE Full Text
  20. 20.↵
    1. Guo Q,
    2. Colasanti A,
    3. Owen DR,
    4. et al
    . Quantification of the specific translocator protein signal of 18F-PBR111 in healthy humans: a genetic polymorphism effect on in vivo binding. J Nucl Med. 2013;54:1915–1923.
    OpenUrlAbstract/FREE Full Text
  21. 21.↵
    1. Lavisse S,
    2. Guillermier M,
    3. Herard AS,
    4. et al
    . Reactive astrocytes overexpress TSPO and are detected by TSPO positron emission tomography imaging. J Neurosci. 2012;32:10809–10818.
    OpenUrlAbstract/FREE Full Text
  22. 22.↵
    1. Dickstein LP,
    2. Zoghbi SS,
    3. Fujimura Y,
    4. et al
    . Comparison of 18F- and 11C-labeled aryloxyanilide analogs to measure translocator protein in human brain using positron emission tomography. Eur J Nucl Med Mol Imaging. 2011;38:352–357.
    OpenUrlCrossRefPubMed
  23. 23.↵
    1. Ohnishi A,
    2. Senda M,
    3. Yamane T,
    4. et al
    . Human whole-body biodistribution and dosimetry of a new PET tracer, [11C]ketoprofen methyl ester, for imagings of neuroinflammation. Nucl Med Biol. 2014;41:594–599.
    OpenUrlCrossRefPubMed
  24. 24.↵
    1. Savonenko AV,
    2. Melnikova T,
    3. Wang Y,
    4. et al
    . Cannabinoid CB2 receptors in a mouse model of Abeta amyloidosis: immunohistochemical analysis and suitability as a PET biomarker of neuroinflammation. PLoS One. 2015;10:e0129618.
    OpenUrlCrossRefPubMed
  25. 25.↵
    1. Slavik R,
    2. Herde AM,
    3. Bieri D,
    4. et al
    . Synthesis, radiolabeling and evaluation of novel 4-oxo-quinoline derivatives as PET tracers for imaging cannabinoid type 2 receptor. Eur J Med Chem. 2015;92:554–564.
    OpenUrlCrossRefPubMed
  • Received for publication April 22, 2015.
  • Accepted for publication December 22, 2015.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 57 (2)
Journal of Nuclear Medicine
Vol. 57, Issue 2
February 1, 2016
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Imaging Microglial Activation with TSPO PET: Lighting Up Neurologic Diseases?
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Imaging Microglial Activation with TSPO PET: Lighting Up Neurologic Diseases?
Lucy Vivash, Terence J. O’Brien
Journal of Nuclear Medicine Feb 2016, 57 (2) 165-168; DOI: 10.2967/jnumed.114.141713

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Imaging Microglial Activation with TSPO PET: Lighting Up Neurologic Diseases?
Lucy Vivash, Terence J. O’Brien
Journal of Nuclear Medicine Feb 2016, 57 (2) 165-168; DOI: 10.2967/jnumed.114.141713
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • 11C-PK11195
    • SECOND- AND THIRD-GENERATION TSPO RADIOTRACERS IN NEUROLOGIC DISEASES
    • LIMITATIONS OF NEW TSPO RADIOTRACERS
    • ALTERNATIVES TO TSPO IMAGING
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Repeatability and reproducibility of in-vivo brain temperature measurements
  • Microglial activation and tau burden predict cognitive decline in Alzheimers Disease
  • Preclinical Evaluation and Nonhuman Primate Receptor Occupancy Study of 18F-JNJ-64413739, a PET Radioligand for P2X7 Receptors
  • Aged blood inhibits hippocampal neurogenesis and activates microglia through VCAM1 at the blood-brain barrier
  • GABA levels and TSPO expression in people at clinical high risk for psychosis and healthy volunteers: a PET-MRS study
  • Molecular Imaging of Myocardial Inflammation With Positron Emission Tomography Post-Ischemia: A Determinant of Subsequent Remodeling or Recovery
  • Google Scholar

More in this TOC Section

  • From Genome to Phenome: Opportunities and Challenges of Molecular Imaging
  • Imaging the Activity of Efflux Transporters at the Blood–Brain Barrier in Neurologic Diseases: Radiotracer Selection Criteria
  • Molecular Imaging of Pulmonary Fibrosis
Show more Focus on Molecular Imaging

Similar Articles

Keywords

  • Positron Emission Tomography
  • TSPO
  • microglia
  • Neurology
  • 11C-PK11195
SNMMI

© 2025 SNMMI

Powered by HighWire