Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Investigations

Prospective Comparison of 99mTc-MDP Scintigraphy, Combined 18F-NaF and 18F-FDG PET/CT, and Whole-Body MRI in Patients with Breast and Prostate Cancer

Ryogo Minamimoto, Andreas Loening, Mehran Jamali, Amir Barkhodari, Camila Mosci, Tatianie Jackson, Piotr Obara, Valentina Taviani, Sanjiv Sam Gambhir, Shreyas Vasanawala and Andrei Iagaru
Journal of Nuclear Medicine December 2015, 56 (12) 1862-1868; DOI: https://doi.org/10.2967/jnumed.115.162610
Ryogo Minamimoto
1Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, Stanford, California
2Molecular Imaging Program at Stanford, Department of Radiology, Stanford University, Stanford, California; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Andreas Loening
3Radiological Sciences Laboratory, Department of Radiology, Stanford University, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mehran Jamali
1Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, Stanford, California
2Molecular Imaging Program at Stanford, Department of Radiology, Stanford University, Stanford, California; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Amir Barkhodari
1Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Camila Mosci
1Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tatianie Jackson
1Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Piotr Obara
3Radiological Sciences Laboratory, Department of Radiology, Stanford University, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Valentina Taviani
3Radiological Sciences Laboratory, Department of Radiology, Stanford University, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sanjiv Sam Gambhir
1Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, Stanford, California
2Molecular Imaging Program at Stanford, Department of Radiology, Stanford University, Stanford, California; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Shreyas Vasanawala
3Radiological Sciences Laboratory, Department of Radiology, Stanford University, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Andrei Iagaru
1Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, Stanford, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

We prospectively evaluated the use of combined 18F-NaF/18F-FDG PET/CT in patients with breast and prostate cancer and compared the results with those for 99mTc-MDP bone scintigraphy and whole-body MRI. Methods: Thirty patients (15 women with breast cancer and 15 men with prostate cancer) referred for standard-of-care bone scintigraphy were prospectively enrolled in this study. 18F-NaF/18F-FDG PET/CT and whole-body MRI were performed after bone scintigraphy. The whole-body MRI protocol consisted of both unenhanced and contrast-enhanced sequences. Lesions detected with each test were tabulated, and the results were compared. Results: For extraskeletal lesions, 18F-NaF/18F-FDG PET/CT and whole-body MRI had no statistically significant differences in sensitivity (92.9% vs. 92.9%, P = 1.00), positive predictive value (81.3% vs. 86.7%, P = 0.68), or accuracy (76.5% vs. 82.4%, P = 0.56). However, 18F-NaF/18F-FDG PET/CT showed significantly higher sensitivity and accuracy than whole-body MRI (96.2% vs. 81.4%, P < 0.001, 89.8% vs. 74.7%, P = 0.01) and bone scintigraphy (96.2% vs. 64.6%, P < 0.001, 89.8% vs. 65.9%, P < 0.001) for the detection of skeletal lesions. Overall, 18F-NaF/18F-FDG PET/CT showed higher sensitivity and accuracy than whole-body MRI (95.7% vs. 83.3%, P < 0.002, 87.6% vs. 76.0%, P < 0.02) but not statistically significantly so when compared with a combination of whole-body MRI and bone scintigraphy (95.7% vs. 91.6%, P = 0.17, 87.6% vs. 83.0%, P = 0.53). 18F-NaF/18F-FDG PET/CT showed no significant difference from a combination of 18F-NaF/18F-FDG PET/CT and whole-body MRI. No statistically significant differences in positive predictive value were noted among the 3 examinations. Conclusion: 18F-NaF/18F-FDG PET/CT is superior to whole-body MRI and 99mTc-MDP scintigraphy for evaluation of skeletal disease extent. Further, 18F-NaF/18F-FDG PET/CT and whole-body MRI detected extraskeletal disease that may change the management of these patients. 18F-NaF/18F-FDG PET/CT provides diagnostic ability similar to that of a combination of whole-body MRI and bone scintigraphy in patients with breast and prostate cancer. Larger cohorts are needed to confirm these preliminary findings, ideally using the newly introduced simultaneous PET/MRI scanners.

  • 99mTc-MDP
  • 18F-NaF
  • 18F-FDG
  • whole-body MRI
  • prostate cancer
  • breast cancer

In patients with breast cancer, the National Comprehensive Cancer Network guidelines recommend diagnostic CT of the chest and abdomen (and pelvis if needed), 99mTc-methylene diphosphonate (99mTc-MDP) bone scintigraphy or 18F-NaF PET/CT, and optional 18F-FDG PET/CT (1). Although 18F-FDG PET/CT has great potential for identifying locally advanced and metastatic lesions (2), the guidelines recommend it only if the results of conventional imaging are equivocal or suggestive. Bone scintigraphy or 18F-NaF PET/CT may be avoided when 18F-FDG PET/CT has already identified skeletal metastasis, according to the same guidelines. However, the sensitivity of 18F-FDG PET/CT for detection of osteoblastic lesions is limited in breast cancer (3). 18F-FDG PET/CT has not been recommended by the National Comprehensive Cancer Network guidelines for prostate cancer (4), although there are reports suggesting its usefulness in detecting locally recurrent or metastatic disease, assessing the extent of metabolically active, castration-resistant disease (5). 18F-FDG uptake in prostate cancer lesions is an independent prognostic factor and provides information complementary to that from bone scintigraphy (6). 18F-NaF PET/CT has greater sensitivity than bone scintigraphy and therefore has been recommended for evaluation of skeletal metastases in patients with prostate cancer (4). Skeletal metastases from prostate cancer are usually osteoblastic but may also have mixed or osteolytic features (7). 18F-NaF PET/CT is superior to bone scintigraphy for skeletal lesion detection in prostate and breast cancer (8–11).

Whole-body MRI with diffusion-weighted imaging is as sensitive as 18F-FDG PET/CT but less specific for the detection of locoregional or metastatic breast cancer (12). Whole-body diffusion-weighted imaging has higher specificity but lower sensitivity than 18F-NaF PET/CT in prostate cancer (13).

The combined administration of 18F-NaF and 18F-FDG (18F−/18F-FDG) in a single PET/CT scan for cancer detection has been advocated for detecting both extraskeletal and skeletal lesions (14,15), and a prospective international multicenter trial showed promising results (16).

We now evaluated the performance of 18F−/18F-FDG PET/CT for the detection of extraskeletal and skeletal lesions in a selected population of patients with breast and prostate cancer and compared it with whole-body MRI and bone scintigraphy.

MATERIALS AND METHODS

Patient Population

The local Institutional Review Board and Cancer Center Scientific Review Committee approved this study, and all participants gave written informed consent. To be included, patients had to be older than 18 y at the time of recruitment; have a diagnosis of breast cancer with an initial clinical stage of III or more; have a diagnosis of prostate cancer with an initial clinical stage of II or more or a serum prostate-specific antigen level of 10 or more; have been referred for evaluation of possible skeletal metastases with bone scintigraphy or have shown the presence of skeletal metastases on bone scintigraphy; and be able to remain still for the duration of the imaging procedure. Exclusion criteria were limited to pregnancy/nursing and the presence of metallic implants (contraindicated for whole-body MRI).

Between November 2012 and July 2014, 15 women (mean age ± SD, 54.1 ± 12.6 y; range, 34–76 y) with pathologically proven breast cancer and 15 men (mean age ± SD, 68.3 ± 9.4 y; range, 52–84 y) with pathologically proven prostate cancer were included in this study. Bone scintigraphy was performed first and was followed by the 18F−/18F-FDG PET/CT and whole-body MRI scans. The interval was 15.4 ± 8.0 d between bone scintigraphy and 18F−/18F-FDG PET/CT and 2.5 ± 3.9 d between 18F−/18F-FDG PET/CT and whole-body MRI. At the time of bone scintigraphy, the prostate-specific antigen levels for prostate cancer patients, and the pathologic result for expression of estrogen receptor, progesterone receptor, and human epidermal receptor 2 for breast cancer patients, were recorded.

Bone Scintigraphy Protocol

No patient preparation was required. Pregnancy was excluded by history. The intravenous dose of 99mTc-MDP was 935.6 ± 42.1 MBq (range, 777.0–1,017.5 MBq). The patients were asked to return to the clinic 3 h after 99mTc-MDP administration, during which time they were encouraged to hydrate and void. On returning, planar images of the whole body and spot views of the thorax and pelvis in anterior and posterior views were acquired. Per routine clinical practice, additional spot (planar or oblique) views of the body were obtained if deemed necessary. The images were acquired using dual-head γ-cameras (Infinia Hawkeye 4 [GE Healthcare] or Skylight [Philips Healthcare]). All images were interpreted using a dedicated Xeleris workstation version 2.0551; GE Healthcare). SPECT or SPECT/CT images were not acquired.

18F−/18F-FDG PET/CT Protocol

The patients were scanned on Discovery 600 or 690 scanners (GE Healthcare). There were only small (<10%) differences in SUV measurements between scanners based on data from phantom studies. Patients were asked to fast for 6 h before injection of 18F−/18F-FDG. For the 18F−/18F-FDG PET/CT scans, the 2 radiotracers were delivered from the local cyclotron facilities in separate syringes and intravenously administered sequentially, without delay. For all PET/CT scans, total-body (vertex to toes) PET/CT images were obtained in 3-dimensional mode, with the patients’ arms at their sides. The PET images were reconstructed with a standard iterative algorithm (ordered-subset expectation maximization, 2 iterative steps and 32 subsets for Discovery 600 and 2 iterative steps and 24 subsets for Discovery 690), as recommended by the manufacturer.

The dosages of 18F−/18F-FDG were 567.0 ± 30.0 MBq (range, 506.9–625.3 MBq), of which 18F-FDG included 370.1 ± 24.7 MBq (range, 321.9–414.4 MBq) and 18F-NaF included 189.8 ± 16.1 MBq (range, 155.4–218.3 MBq). The time from injection to the start of the 18F−/18F-FDG PET/CT scans was 70.1 ± 12.2 min (range, 50–104 min).

Whole-Body MRI Protocols and Image Reconstruction

Whole-body MRI studies were acquired on a 750W 3-T scanner (GE Healthcare) using a whole-body coil. Unenhanced sequences included coronal T1-weighted fast spin echo imaging (repetition time/echo time [TR/TE], ∼700/8 ms; echo train length, 6; bandwidth, 54 kHz; flip angle, 90°; slice thickness, 8 mm; 0.5 excitations; field of view, 44 cm; matrix, 448 × 256), coronal short-τ inversion recovery imaging (TR/TE, 9,500/45 ms; inversion time, 190 ms; echo train length, 20; bandwidth, 62.5 kHz; slice thickness, 8 mm; field of view, 44 cm; 0.5 excitations; matrix, 384 × 224) with station 2 (lungs) acquired in a breath hold (TR/TE, 3,000/45 ms; inversion time, 190 ms; slice thickness, 8 mm; field of view, 44 cm; 0.5 excitations; matrix, 384 × 192), and axial echo planar diffusion-weighted imaging (TR/TE, 4,300/55 ms; slice thickness, 8 mm; slice spacing, 8 mm; b value, 50 and 500 ms; field of view, 40 cm; 4 excitations; matrix, 80 × 128). After injection of a weight-based dose of gadofosveset (Ablavar; Lantheus Medical Imaging), enhanced sequences were obtained consisting of axial 3-dimensional spoiled gradient recalled echo imaging with 2-point Dixon fat/water separation (flip angle, 15°; TR/TE, 4.5/1.1 and 2.3 ms; slice thickness, 3 mm; field of view, 44 cm; matrix, 320 × 256).

Image Analysis

The bone scintigraphy and 18F−/18F-FDG PET/CT scans were interpreted by 2 board-certified nuclear medicine physicians in randomized order, with masking of the diagnosis and the results of other imaging studies. Two board-certified radiologists performed the whole-body MRI interpretation also in randomized order. Agreement was reached by consensus. A direct comparison for each detected lesion was performed among the 3 scans by one of the investigators. For the interpretation of the scans, visual analysis was used instead of semiquantitative analysis (i.e., SUV cutoffs). For the 18F−/18F-FDG PET/CT scans, areas of focally increased 18F−/18F-FDG uptake were recorded as malignant unless a benign etiology (e.g., degenerative changes or hemangioma) for this uptake was identified at the same location on the corresponding CT images. The CT component of PET/CT was used to determine whether bone lesions identified on PET had an osteoblastic or osteolytic appearance. For whole-body MRI, all sequences were assessed concurrently, with the radiologist’s clinical experience used for detecting lesions. Visual conspicuity against background on the diffusion-weighted images and the presence of an anatomically corresponding abnormality on the fast spoiled gradient-echo and short-τ inversion recovery images were the criteria for detecting a lesion on whole-body MRI. Diagnostic accuracy was evaluated by comparing the bone scintigraphy, 18F−/18F-FDG PET/CT, and whole-body MRI results with the final diagnoses as confirmed by histologic evaluation, clinical follow-up, or other imaging studies. We also evaluated the diagnostic ability of combining the results from bone scintigraphy and whole-body MRI and from 18F−/18F-FDG PET/CT and whole-body MRI.

Statistical Analysis

Differences in sensitivity and accuracy were compared by the McNemar test. The χ2 test for independence was performed to compare the positive predictive value (PPV). The statistical difference of specificity and negative predictive value (NPV) were not tested in this study because of the bias in the population. P values of less than 0.05 were considered statistically significant.

RESULTS

The clinical characteristics of the enrolled patients are shown in Table 1. Two patients with prostate cancer could not complete the whole-body MRI scan and were therefore excluded from the analysis.

View this table:
  • View inline
  • View popup
TABLE 1

Clinical Characteristics of Patient Population

Pathology reports (13% of the patients) or clinical follow-up (87% of the patients) were available as the gold standard for the results. Suspected malignant lesions were identified by 18F−/18F-FDG PET/CT in 20 of 30 participants (breast cancer: n = 12, prostate cancer: n = 8), by bone scintigraphy in 16 of 30 participants (breast cancer: n = 10, prostate cancer: n = 6), by whole-body MRI in 19 of 28 participants (breast cancer: n = 11, prostate cancer: n = 8), by a combination of whole-body MRI and bone scintigraphy in 19 of 28 participants (breast cancer: n = 11, prostate cancer: n = 8), and by a combination of whole-body MRI and 18F−/18F-FDG PET/CT in 20 of 28 participants (breast cancer: n = 11, prostate cancer: n = 9). Typical examples are shown in Figures 1–3.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

A 49-y-old woman with breast cancer. (A) Planar whole-body anterior view from 99mTc-MDP bone scan and (B) maximum-intensity-projection 18F−/18F-FDG PET images show multiple bone metastases, more conspicuous on PET. (C) Transaxial fused PET/CT scan demonstrates liver metastasis (arrow). (D) Brain metastases are identified on contrast-enhanced T1-weighted MR images (arrowheads). These were not seen on 18F−/18F-FDG PET/CT.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

A 70-y-old man with prostate cancer. (A and B) Planar whole-body anterior view from 99mTc-MDP bone scan (A) and maximum-intensity-projection 18F−/18F-FDG PET images (B) show bone metastases in skull base and right iliac bone, more conspicuous on PET. (C) Skull base lesion was not identified prospectively on CT or contrast-enhanced T1-weighted MRI. (D) Right iliac bone lesion was not identified prospectively on CT or contrast-enhanced T1-weighted MRI.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

A 53-y-old woman with breast cancer. (A and B) Planar whole-body anterior view from 99mTc-MDP bone scan (A) is negative for bone metastases, whereas maximum-intensity-projection 18F−/18F-FDG PET images (B) show bone metastases in multiple locations, including right femur. (C) Proximal right femur metastasis was not identified prospectively on CT or contrast-enhanced T1-weighted MRI. (D) Maximum-intensity projection from follow-up 18F−/18F-FDG PET done 6 mo later demonstrates progression of bone metastases, including in right femur.

Patient-Based Analysis

Table 2 shows the results of the per-patient analysis. Overestimation of clinical staging by 18F−/18F-FDG PET/CT occurred in 2 participants. One was a case of false-positive findings in the pelvic skeleton in a patient with prostate cancer, and the other was a case of false-positive findings in an axillary lymph node in a patient with breast cancer. Overestimation of clinical stage by whole-body MRI occurred in the patient who had a false-positive axillary lymph node on 18F−/18F-FDG PET/CT. Bone scintigraphy failed to identify skeletal lesion in 2 patients, but these were demonstrated on the corresponding whole-body MRI.

View this table:
  • View inline
  • View popup
TABLE 2

Results of Per-Patient Analysis

Lesion-Based Analysis

Total Lesions

In total 98 lesions (extraskeletal: n = 16; skeletal: n = 82) were identified by 18F−/18F-FDG PET/CT in 30 participants, 79 lesions (extraskeletal: n = 15; skeletal: n = 64) were identified by whole-body MRI in 28 participants, 53 lesions (all skeletal) were identified by bone scintigraphy in 30 participants, 85 lesions (extraskeletal: n = 15, skeletal: n = 70) were identified by a combination of whole-body MRI and bone scintigraphy in 28 participants, and 96 lesions (extraskeletal: n = 17; skeletal: n = 79) were identified by a combination of 18F−/18F-FDG PET/CT and whole-body MRI in 28 participants.

The per-lesion sensitivity, specificity, PPV, NPV, and accuracy of 18F−/18F-FDG PET/CT, whole-body MRI, bone scintigraphy, and the combination of whole-body MRI and bone scintigraphy are shown in Table 3. For extraskeletal lesions, 18F−/18F-FDG PET/CT and whole-body MRI had no statistically significant differences in sensitivity (P = 1.00), PPV (P = 0.32), or accuracy (P = 0.56). However, 18F−/18F-FDG PET/CT showed significantly higher sensitivity and accuracy than whole-body MRI (P < 0.001, P < 0.02) and bone scintigraphy (P < 0.001, P < 0.001) for the detection of skeletal lesions. Overall, 18F−/18F-FDG PET/CT showed higher sensitivity and accuracy than whole-body MRI (P < 0.002, P < 0.02) but not statistically significantly so when compared with a combination of whole-body MRI and bone scintigraphy (P = 0.17, P = 0.52). 18F−/18F-FDG PET/CT showed no difference from a combination of 18F−/18F-FDG PET/CT and whole-body MRI. No statistically significant differences in PPV were noted among the 3 examinations.

View this table:
  • View inline
  • View popup
TABLE 3

Per-Lesion Analysis (Breast and Prostate Cancers)

Skeletal Lesions

Among 82 skeletal lesions identified on the CT component of PET/CT, 6 were osteolytic; all 6 occurred in patients with breast cancer. The other 76 lesions were osteoblastic. The per-lesion sensitivity, specificity, PPV, NPV, and accuracy of 18F−/18F-FDG PET/CT, whole-body MRI, bone scintigraphy, and the combination of whole-body MRI and bone scintigraphy for the osteolytic and osteoblastic skeletal lesions are shown in Tables 3 (prostate and breast cancer) and 4 (breast cancer). For osteolytic lesions, 18F−/18F-FDG PET/CT and whole-body MRI showed higher sensitivity than bone scintigraphy, but no statistical significance was achieved given the small number of lesions.

View this table:
  • View inline
  • View popup
TABLE 4

Per-Lesion Analysis (Breast Cancer)

For osteoblastic lesions, 18F−/18F-FDG PET/CT had significantly higher sensitivity (P < 0.001) and accuracy (P < 0.001) than bone scintigraphy. 18F−/18F-FDG PET/CT had no statistically significant differences in sensitivity (P = 0.61) or PPV (P = 0.43) but had higher accuracy than whole-body MRI (P < 0.05). 18F−/18F-FDG PET/CT showed no statistically significant difference from a combination of whole-body MRI and bone scintigraphy (P = 0.32, P = 0.13) but was less sensitive than a combination of 18F−/18F-FDG PET/CT and whole-body MRI (P = 0.01).

Breast Cancer

The per-lesion sensitivity, specificity, PPV, NPV, and accuracy of 18F−/18F-FDG PET/CT, whole-body MRI, bone scintigraphy, and the combination of whole-body MRI and bone scintigraphy are shown in Table 4. 18F−/18F-FDG PET/CT had no statistically significant differences from whole-body MRI in sensitivity (P = 1.00) or accuracy (P = 0.56) for extraskeletal lesions. 18F−/18F-FDG PET/CT had significantly higher sensitivity and accuracy for the detection of skeletal lesions than bone scintigraphy (P < 0.001), but not when compared with whole-body MRI (P = 0.21). 18F−/18F-FDG PET/CT showed no significant differences from the combination of whole-body MRI and bone scintigraphy (P = 1.00). Overall, 18F−/18F-FDG PET/CT had no significant differences in sensitivity and accuracy from whole-body MRI (P = 0.56, P = 0.17) or the combination of whole-body MRI and bone scintigraphy (P = 0.71, P = 0.74). 18F−/18F-FDG PET/CT had lower sensitivity and accuracy than a combination of results from 18F−/18F-FDG PET/CT and whole-body MRI (P < 0.05). No significant differences in PPV were noted among the 3 examinations.

For osteoblastic lesions, 18F−/18F-FDG PET/CT had significantly higher sensitivity (P < 0.001) and accuracy (P < 0.001) than bone scintigraphy. 18F−/18F-FDG PET/CT had no statistically significant differences in sensitivity (P = 0.21) or accuracy (P = 0.21) from whole-body MRI. 18F−/18F-FDG PET/CT showed no statistically significant difference in sensitivity or accuracy from a combination of whole-body MRI and bone scintigraphy (P = 1.00, P = 1.00) or a combination of 18F−/18F-FDG PET/CT and whole-body MRI (P = 0.08, P = 0.08).

Prostate Cancer

The per-lesion sensitivity, specificity, PPV, NPV, and accuracy of 18F−/18F-FDG PET/CT, whole-body MRI, bone scintigraphy, and the combination of whole-body MRI and bone scintigraphy are shown in Table 5. Both 18F−/18F-FDG PET/CT and whole-body MRI detected additional extraskeletal lesions in 2 patients. 18F−/18F-FDG PET/CT had significantly higher sensitivity than whole-body MRI (P < 0.02) and bone scintigraphy (P < 0.03) in the evaluation of skeletal lesions. However, 18F−/18F-FDG PET/CT had no significant difference in sensitivity from a combination of whole-body MRI and bone scintigraphy (P = 0.08). Overall, 18F−/18F-FDG PET/CT had statistically significant higher sensitivity than whole-body MRI (P < 0.02), but not when compared with a combination of whole-body MRI and bone scintigraphy (P = 0.08) or 18F−/18F-FDG PET/CT and whole-body MRI (P = 1.00). No statistically significant differences in PPV were identified between these examinations.

View this table:
  • View inline
  • View popup
TABLE 5

Per-Lesion Analysis (Prostate Cancer)

DISCUSSION

Our study suggests that PET/CT done after administration of 18F-NaF and 18F-FDG followed by a single PET/CT scan has higher accuracy than whole-body MRI and bone scintigraphy for evaluation of the extent of disease in this population of patients with breast and prostate cancer. 18F−/18F-FDG PET/CT performed as well as a combination of whole-body MRI and bone scintigraphy; therefore, it may serve as a one-stop shop in the imaging management of patients with certain cancers.

Although 18F-FDG PET/CT can provide high diagnostic accuracy in both the initial and recurrent breast cancer settings compared with conventional imaging (17–19), it has several limitations for the diagnosis of patients with prostate cancer (5). 18F-FDG PET/CT is also not recommended for the detection of osteoblastic skeletal lesions (3,20). 18F-NaF PET/CT is superior to bone scintigraphy and 18F-FDG PET/CT for the detection of osteoblastic metastases (21). Another study showed that whole-body MRI with diffusion-weighted imaging had results similar to 18F-NaF PET/CT in breast cancer and superior to bone scintigraphy (22). The combined 18F−/18F-FDG PET/CT scan can increase sensitivity in the detection of osseous lesions compared with 18F-FDG PET/CT (14–16,23).

Whole-body MRI detected brain metastases that were missed on 18F−/18F-FDG PET/CT because of high physiologic 18F-FDG uptake in the normal cerebral cortex. Therefore, whole-body MRI may be able to provide complementary information in areas where 18F-FDG PET/CT has known limitations in diagnosis.

Hybrid PET/MRI has recently been introduced clinically. Compared with PET/CT, PET/MRI has advantages due to the better soft-tissue contrast of MRI (24,25). PET and MRI provide complementary information, as they evaluate different biologic processes (26). Therefore, simultaneous 18F−/18F-FDG PET/MRI may provide more accurate diagnostic performance in patients with breast and prostate cancer.

Limitations of this study include the relatively small number of participants, variations in injected dosage, variations in the time from injection to imaging, and lack of semiquantitative measurements such as SUV. The optimal ratio of 18F-NaF to 18F-FDG in the 18F−/18F-FDG PET/CT scan is also known to be an issue for this approach to imaging cancer patients (27).

CONCLUSION

18F−/18F-FDG PET/CT and whole-body MRI are superior to 99mTc-MDP scintigraphy for evaluation of the extent of skeletal disease, as expected from already published data. Further, PET/CT and whole-body MRI detected extraskeletal disease that may change the management of these patients. 18F−/18F-FDG PET/CT provides diagnostic ability similar to that of a combination of whole-body MRI and bone scintigraphy in patients with breast and prostate cancer. Larger cohorts are needed to confirm these preliminary findings, ideally using the newly introduced simultaneous PET/MRI scanners.

DISCLOSURE

The costs of publication of this article were defrayed in part by the payment of page charges. Therefore, and solely to indicate this fact, this article is hereby marked “advertisement” in accordance with 18 USC section 1734. GE Healthcare provided financial support for the study; the authors had control of the data and information submitted for publication. No other potential conflict of interest relevant to this article was reported.

Acknowledgments

We thank our research coordinators, Frederick Chin, PhD, the staff at the Lucas Cyclotron, and the technologists in the Division of Nuclear Medicine and Molecular Imaging. Special thanks are extended to all our patients and their families.

Footnotes

  • Published online Sep. 24, 2015.

  • © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

REFERENCES

  1. 1.↵
    1. Gradishar WJ,
    2. Anderson BO,
    3. Balassanian R,
    4. et al
    . Breast cancer, version 2.2015. J Natl Compr Canc Netw. 2015;13:448–475.
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    1. Eubank WB,
    2. Mankoff D,
    3. Bhattacharya M,
    4. et al
    . Impact of FDG PET on defining the extent of disease and on the treatment of patients with recurrent or metastatic breast cancer. AJR. 2004;183:479–486.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Nakai T,
    2. Okuyama C,
    3. Kubota T,
    4. et al
    . Pitfalls of FDG-PET for the diagnosis of osteoblastic bone metastases in patients with breast cancer. Eur J Nucl Med Mol Imaging. 2005;32:1253–1258.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Mohler JL,
    2. Kantoff PW,
    3. Armstrong AJ,
    4. et al
    . Prostate cancer, version 2.2014. J Natl Compr Canc Netw. 2014;12:686–718.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Jadvar H
    . Molecular imaging of prostate cancer with 18F-fluorodeoxyglucose PET. Nat Rev Urol. 2009;6:317–323.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Meirelles GS,
    2. Schoder H,
    3. Ravizzini GC,
    4. et al
    . Prognostic value of baseline [18F] fluorodeoxyglucose positron emission tomography and 99mTc-MDP bone scan in progressing metastatic prostate cancer. Clin Cancer Res. 2010;16:6093–6099.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. Koutsilieris M,
    2. Rabbani SA,
    3. Bennett HP,
    4. Goltzman D
    . Characteristics of prostate-derived growth factors for cells of the osteoblast phenotype. J Clin Invest. 1987;80:941–946.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Even-Sapir E,
    2. Metser U,
    3. Mishani E,
    4. Lievshitz G,
    5. Lerman H,
    6. Leibovitch I
    . The detection of bone metastases in patients with high-risk prostate cancer: 99mTc-MDP planar bone scintigraphy, single- and multi-field-of-view SPECT, 18F-fluoride PET, and 18F-fluoride PET/CT. J Nucl Med. 2006;47:287–297.
    OpenUrlAbstract/FREE Full Text
  9. 9.
    1. Ben-Haim S,
    2. Israel O
    . Breast cancer: role of SPECT and PET in imaging bone metastases. Semin Nucl Med. 2009;39:408–415.
    OpenUrlCrossRefPubMed
  10. 10.
    1. Iagaru A,
    2. Mittra E,
    3. Dick DW,
    4. Gambhir SS
    . Prospective evaluation of 99mTc MDP scintigraphy, 18F NaF PET/CT, and 18F FDG PET/CT for detection of skeletal metastases. Mol Imaging Biol. 2012;14:252–259.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Withofs N,
    2. Grayet B,
    3. Tancredi T,
    4. et al
    . 18F-fluoride PET/CT for assessing bone involvement in prostate and breast cancers. Nucl Med Commun. 2011;32:168–176.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Heusner TA,
    2. Kuemmel S,
    3. Koeninger A,
    4. et al
    . Diagnostic value of diffusion-weighted magnetic resonance imaging (DWI) compared to FDG PET/CT for whole-body breast cancer staging. Eur J Nucl Med Mol Imaging. 2010;37:1077–1086.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. Mosavi F,
    2. Johansson S,
    3. Sandberg DT,
    4. Turesson I,
    5. Sorensen J,
    6. Ahlstrom H
    . Whole-body diffusion-weighted MRI compared with 18F-NaF PET/CT for detection of bone metastases in patients with high-risk prostate carcinoma. AJR. 2012;199:1114–1120.
    OpenUrlCrossRefPubMed
  14. 14.↵
    1. Iagaru A,
    2. Mittra E,
    3. Yaghoubi SS,
    4. et al
    . Novel strategy for a cocktail 18F-fluoride and 18F-FDG PET/CT scan for evaluation of malignancy: results of the pilot-phase study. J Nucl Med. 2009;50:501–505.
    OpenUrlAbstract/FREE Full Text
  15. 15.↵
    1. Lin FI,
    2. Rao JE,
    3. Mittra ES,
    4. et al
    . Prospective comparison of combined 18F-FDG and 18F-NaF PET/CT vs. 18F-FDG PET/CT imaging for detection of malignancy. Eur J Nucl Med Mol Imaging. 2012;39:262–270.
    OpenUrlCrossRefPubMed
  16. 16.↵
    1. Iagaru A,
    2. Mittra E,
    3. Mosci C,
    4. et al
    . Combined 18F-fluoride and 18F-FDG PET/CT scanning for evaluation of malignancy: results of an international multicenter trial. J Nucl Med. 2013;54:176–183.
    OpenUrlAbstract/FREE Full Text
  17. 17.↵
    1. Radan L,
    2. Ben-Haim S,
    3. Bar-Shalom R,
    4. Guralnik L,
    5. Israel O
    . The role of FDG-PET/CT in suspected recurrence of breast cancer. Cancer. 2006;107:2545–2551.
    OpenUrlCrossRefPubMed
  18. 18.
    1. Rosen EL,
    2. Eubank WB,
    3. Mankoff DA
    . FDG PET, PET/CT, and breast cancer imaging. Radiographics. 2007;27(suppl 1):S215–S229.
    OpenUrlCrossRefPubMed
  19. 19.↵
    1. Dirisamer A,
    2. Halpern BS,
    3. Flory D,
    4. et al
    . Integrated contrast-enhanced diagnostic whole-body PET/CT as a first-line restaging modality in patients with suspected metastatic recurrence of breast cancer. Eur J Radiol. 2010;73:294–299.
    OpenUrlCrossRefPubMed
  20. 20.↵
    1. Uematsu T,
    2. Yuen S,
    3. Yukisawa S,
    4. et al
    . Comparison of FDG PET and SPECT for detection of bone metastases in breast cancer. AJR. 2005;184:1266–1273.
    OpenUrlCrossRefPubMed
  21. 21.↵
    1. Hsu WK,
    2. Virk MS,
    3. Feeley BT,
    4. Stout DB,
    5. Chatziioannou AF,
    6. Lieberman JR
    . Characterization of osteolytic, osteoblastic, and mixed lesions in a prostate cancer mouse model using 18F-FDG and 18F-fluoride PET/CT. J Nucl Med. 2008;49:414–421.
    OpenUrlAbstract/FREE Full Text
  22. 22.↵
    1. Yoon SH,
    2. Kim KS,
    3. Kang SY,
    4. et al
    . Usefulness of 18F-fluoride PET/CT in breast cancer patients with osteosclerotic bone metastases. Nucl Med Mol Imaging. 2013;47:27–35.
    OpenUrlCrossRefPubMed
  23. 23.↵
    1. Minamimoto R,
    2. Mosci C,
    3. Jamali M,
    4. et al
    . Semiquantitative analysis of the biodistribution of the combined 18F-NaF and 18F-FDG administration for PET/CT imaging. J Nucl Med. 2015;56:688–694.
    OpenUrlAbstract/FREE Full Text
  24. 24.↵
    1. Iagaru A,
    2. Mittra E,
    3. Minamimoto R,
    4. et al
    . Simultaneous whole-body time-of-flight 18F-FDG PET/MRI: a pilot study comparing SUVmax with PET/CT and assessment of MR image quality. Clin Nucl Med. 2015;40:1–8.
    OpenUrlCrossRefPubMed
  25. 25.↵
    1. Antoch G,
    2. Bockisch A
    . Combined PET/MRI: a new dimension in whole-body oncology imaging? Eur J Nucl Med Mol Imaging. 2009;36(suppl 1):S113–S120.
    OpenUrlCrossRefPubMed
  26. 26.↵
    1. Kwee TC,
    2. Takahara T,
    3. Ochiai R,
    4. et al
    . Complementary roles of whole-body diffusion-weighted MRI and 18F-FDG PET: the state of the art and potential applications. J Nucl Med. 2010;51:1549–1558.
    OpenUrlAbstract/FREE Full Text
  27. 27.↵
    1. Richmond K,
    2. McLean N,
    3. Rold T,
    4. Szczodroski A,
    5. Dresser T,
    6. Hoffman T
    . Optimizing a F-18 NaF and FDG cocktail as a preclinical cancer screening tool for molecular imaging [abstract]. J Nucl Med. 2011;52(suppl 1):2455.
    OpenUrl
  • Received for publication June 23, 2015.
  • Accepted for publication September 10, 2015.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 56 (12)
Journal of Nuclear Medicine
Vol. 56, Issue 12
December 1, 2015
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Prospective Comparison of 99mTc-MDP Scintigraphy, Combined 18F-NaF and 18F-FDG PET/CT, and Whole-Body MRI in Patients with Breast and Prostate Cancer
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Prospective Comparison of 99mTc-MDP Scintigraphy, Combined 18F-NaF and 18F-FDG PET/CT, and Whole-Body MRI in Patients with Breast and Prostate Cancer
Ryogo Minamimoto, Andreas Loening, Mehran Jamali, Amir Barkhodari, Camila Mosci, Tatianie Jackson, Piotr Obara, Valentina Taviani, Sanjiv Sam Gambhir, Shreyas Vasanawala, Andrei Iagaru
Journal of Nuclear Medicine Dec 2015, 56 (12) 1862-1868; DOI: 10.2967/jnumed.115.162610

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Prospective Comparison of 99mTc-MDP Scintigraphy, Combined 18F-NaF and 18F-FDG PET/CT, and Whole-Body MRI in Patients with Breast and Prostate Cancer
Ryogo Minamimoto, Andreas Loening, Mehran Jamali, Amir Barkhodari, Camila Mosci, Tatianie Jackson, Piotr Obara, Valentina Taviani, Sanjiv Sam Gambhir, Shreyas Vasanawala, Andrei Iagaru
Journal of Nuclear Medicine Dec 2015, 56 (12) 1862-1868; DOI: 10.2967/jnumed.115.162610
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • 18F-Sodium Fluoride PET: History, Technical Feasibility, Mechanism of Action, Normal Biodistribution, and Diagnostic Performance in Bone Metastasis Detection Compared with Other Imaging Modalities
  • Anatomic and Molecular Imaging in Prostate Cancer
  • David Versus the Goliaths for the Detection of Bone Metastases
  • Bone-Targeted Imaging and Radionuclide Therapy in Prostate Cancer
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

Keywords

  • 99mTc-MDP
  • 18F-NaF
  • 18F-FDG
  • whole-body MRI
  • prostate cancer
  • breast cancer
SNMMI