Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
LetterLetters to the Editor

Human Cerenkov Imaging Using 18F-FDG

Antonello E. Spinelli and Federico Boschi
Journal of Nuclear Medicine March 2014, 55 (3) 523; DOI: https://doi.org/10.2967/jnumed.113.135384
Antonello E. Spinelli
*San Raffaele Scientific Institute Via Olgettina N. 60 Milan 20182, Italy E-mail:
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: spinelli.antonello@hsr.it
Federico Boschi
*San Raffaele Scientific Institute Via Olgettina N. 60 Milan 20182, Italy E-mail:
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: spinelli.antonello@hsr.it
  • Article
  • Info & Metrics
  • PDF
Loading

TO THE EDITOR: We read with great interest the ahead-of-print article of Thorek et al. (1) recently published online in The Journal of Nuclear Medicine on human Cerenkov imaging using 18F-FDG. Having obtained a similar finding (2) using 131I, we would like to share our knowledge on this topic and comment on some specific claims.

The first issue we would like to underline is related to the set-up of the imaging apparatus. More precisely, it is well known that the Cerenkov light spectrum has an inverse square dependence on the wavelength (3) and, thus, is more intense in the ultraviolet region than in the visible region. However, if one considers the strong tissue absorption of light below 620 nm caused by hemoglobin, the spectrum of the Cerenkov radiation escaping from the tissues contains mainly wavelengths above 630 nm. In a recent paper (4), cited also by Thorek et al., we showed that to improve the in vivo detection of Cerenkov sources it is useful to optimize the optical imaging system in the red, near-infrared region (650–850 nm). It is thus not clear to us why the authors decided to use a short-pass filter with a cutoff at 605 nm since in this way they rejected most of the Cerenkov light reaching the body surface. We also are interested in knowing the characteristics and the manufacturer of the objective used to acquire axilla images (estimated field of view, at least 10 × 10 cm) at a very short distance.

Looking at Figure 2, we noticed the absence of any direct charge-coupled-device detection of γ rays. This is a bit surprising considering also the small working distance from the patient (8 cm). It would thus be interesting to know if the authors applied any γ-rejection algorithm.

Thorek et al. (1) claimed that our human Cerenkography image was obtained with a much higher dose of 131I. This is not entirely true, since the difference between the injected doses is only 14%, or more precisely, 550 MBq of 131I with respect to 470 MBq of 18F-FDG for the representative patient shown in Figure 2. Second, for a fair comparison of the results in terms of Cerenkov light production, it is useful to remember that the emission of Cerenkov radiation is closely related to the decay scheme of the radioisotope; in this case, 18F emits about 2.5 times more Cerenkov light for each decay than does 131I (5). We do agree that 131I thyroid uptake can be typically up to 50%, resulting in an equivalent 18F-FDG uptake of 110 MBq. Considering a spheric lymph node 1.5–2 cm in radius and an uptake value of 0.05 MBq/mL, the corresponding 18F-FDG activity is approximately 0.7–1.7 MBq—that is, 2, not 4 (!), orders of magnitude less than the value claimed in the “Discussion” section by Thorek et al.

Figure 3 of the article by Thorek et al. (1) plots a correlation between the Cerenkov signal and the 18F-FDG concentration measured by PET. This correlation measured in vivo is somewhat surprising since, in this case, the different tissue attenuation (e.g., >different source depth) and not the source strength (MBq/mL) should dominate in determining the average value of the detected Cerenkov signal. Also, the plotted data show that the magnitude of the Cerenkov signal is almost comparable to the contralateral side (except for a single patient). In particular, by considering the point corresponding to the patient in Figure 2 (maximum 18F-FDG concentration. 0.05 MBq/mL), one finds a small difference with respect to the contralateral side points.

Thorek et al. (1) provides a set of system linearity measurements by performing in vitro imaging of a 24-well polycarbonate plate filled with 18F-FDG at different time points and, thus, of different concentrations. As one can see by looking at Figure 1A of the article, the detected Cerenkov signal is quite noisy at a concentration of 0.1 MBq/mL even without any attenuating material. We were thus a bit surprised that the authors were able to detect, at a tissue depth greater than 1 cm, a Cerenkov signal corresponding to an 18F-FDG concentration of 0.03–0.05 MBq/mL. Figure 2 also seems to show that the patient was not shaved, thus making it even more surprising that the authors could detect Cerenkov light crossing the axillary hair.

To summarize, the paper of Thorek et al. (1) contains some puzzling imaging methods and results that in our opinion need to be better explained or justified.

Footnotes

  • Published online Jan. 21, 2014.

  • Note: The ahead-of-print article (1) of Thorek et al. was modified after the submission of our letter to the editor. Our criticisms related to the optical filter and the correlation shown in Figure 3 no longer apply to the final version (6).

  • © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

REFERENCES

  1. 1.↵
    1. Thorek DL,
    2. Riedl CC,
    3. Grimm J
    . Clinical Cerenkov luminescence imaging of 18F-FDG. J Nucl Med. September 27, 2013 [Epub ahead of print].
  2. 2.↵
    1. Spinelli AE,
    2. Ferdeghini M,
    3. Cavedon C,
    4. et al
    . First human Cerenkography [letter]. J Biomed Opt. 2013;18:20502.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Jelley JV
    . Cerenkov Radiation and Its Applications. London, U.K.: Pergamon; 1958.
  4. 4.↵
    1. Spinelli AE,
    2. Boschi F
    . Optimizing in vivo small animal Cerenkov luminescence imaging [letter]. J Biomed Opt. 2012;17:040506.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Liu H,
    2. Ren G,
    3. Miao Z,
    4. et al
    . Molecular optical imaging with radioactive probes. PLoS ONE. 2010;5:e9470.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Thorek DL,
    2. Riedl CC,
    3. Grimm J
    . Clinical Cerenkov luminescence imaging of 18F-FDG. J Nucl Med. 2014;55:95–98.
    OpenUrlAbstract/FREE Full Text
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 55 (3)
Journal of Nuclear Medicine
Vol. 55, Issue 3
March 1, 2014
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Human Cerenkov Imaging Using 18F-FDG
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Human Cerenkov Imaging Using 18F-FDG
Antonello E. Spinelli, Federico Boschi
Journal of Nuclear Medicine Mar 2014, 55 (3) 523; DOI: 10.2967/jnumed.113.135384

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Human Cerenkov Imaging Using 18F-FDG
Antonello E. Spinelli, Federico Boschi
Journal of Nuclear Medicine Mar 2014, 55 (3) 523; DOI: 10.2967/jnumed.113.135384
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Footnotes
    • REFERENCES
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Business Model Beats Science and Logic: Dosimetry and Paucity of Its Use
  • Determining PSMA-617 Mass and Molar Activity in Pluvicto Doses
  • The Value of Functional PET in Quantifying Neurotransmitter Dynamics
Show more Letters to the Editor

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire