Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleInvited Perspective

Standardization of Quantitative Imaging: The Time Is Right, and 18F-FDG PET/CT Is a Good Place to Start

Andrew J. Buckler and Ronald Boellaard
Journal of Nuclear Medicine February 2011, 52 (2) 171-172; DOI: https://doi.org/10.2967/jnumed.110.081224
Andrew J. Buckler
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ronald Boellaard
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

Enhanced techniques have made quantitative medical imaging increasingly important to clinical research ( 1, 2). Performance expectations, and particularly the rigor with which performance is statistically characterized, are high in the research context. Even though individual factors may have a relatively small (5%–30%) effect on quantification by themselves, the overall cumulative effect on quantitative outcome and its precision can be large (50%–100%) ( 3). A great deal of work is needed to achieve effective implementation, not just in individual laboratories but ultimately in general use ( 4, 5). Success will be achieved when quantitative imaging results are broadly comparable and are widely See pages 303 and 311disseminated rather than being possible only in highly selective and controlled environments.

Two important articles on this topic are included in this issue of The Journal of Nuclear Medicine. Graham et al. ( 6) survey the imaging procedure and analysis protocols across 15 leading institutions, including the 8 Imaging Response Assessment Teams. Meanwhile, Beyer et al. ( 7) cast a wider net inclusive of a large range of centers drawn from the Academy of Molecular Imaging databases with responses back from 128 institutions. Despite the very different approaches taken in selecting institutions for their respective surveys, the results are remarkably concordant with respect to how differently sites conduct scans. For example, sites vary across all experience levels with regard to such issues as uptake period, dietary requirements, handling of diabetic patients, weight-based activity injection, handling of extravasations, use of contrast in CT, relationship between diagnostic CT and CT performed for attenuation correction, application of glucose corrections, and ultimately the ability to compare numbers across scanner models and makes, which involves such issues as acquisition timing and reconstruction methods. Differences in how studies are reported, formats used for image data and metadata, level and type of training, and reading practice (e.g., site vs. central reads) add to the issues. It would seem that standardization is a long way off, if judged from the results of these critical reports.

Concern about these topics is by no means new. An often-cited article by Hoffman et al. addressed the issue in 1984 ( 8). By 1999, key articles had been published by Weber et al. ( 9) declaring that reproducibility was possible and by Young et al. ( 10) articulating guidelines to improve consistency. However, several articles in the 2003–2004 time frame, such as by Bourguet et al. ( 11), Hallet ( 12), Feuardent et al. ( 13), and Marsden ( 14), suggested the need for more work to develop, refine, and promulgate consistent protocols if we were to achieve quantitative accuracy. By 2006–2007, new protocol recommendations were published, including articles by Shankar et al. ( 15), Delbeke et al. ( 16), Hallett et al. ( 17), and Westerterp et al. ( 18). These studies showed that strict standardization of all aspects of imaging is required to obtain quantitative, accurate, reliable, and precise results. Moreover, it was becoming increasingly evident that the need to align guidelines across groups was as important as the need for individual groups to make recommendations on what those guidelines could be.

Achieving standardization to minimize variation in multicenter studies and allow comparability of results from different trials necessitates a cooperative structure. Although many stakeholders are interested in this goal, none can accomplish it alone. For example, cooperative groups such as the American College of Radiology Imaging Network, the European Organization for Research and Treatment of Cancer, Cancer and Leukemia Group B, and the Southwest Oncology Group have been established to pursue collaborative clinical studies, as has the SNM Clinical Trials Network. However, industry engagement both by the users of biopharmaceuticals and by suppliers of medical devices and software is also necessary. A unifying platform is critically needed to facilitate cooperation among all the stakeholders.

The process of convergence has quickened in recent years. Wahl has published a proposal for response assessment that incorporates protocol guidance ( 19). Based on work initiated in The Netherlands but with cooperation from other countries such as Germany and the United Kingdom ( 20), the European Association of Nuclear Medicine has arrived at consistent protocol guidance across Europe ( 21). Fukukita has reported on similar efforts in Japan ( 22). Meanwhile, the Food and Drug Administration garnered a high degree of interest at an April 2010 meeting jointly hosted by the SNM and the Radiological Society of North America dealing with standardization to control variability and inconsistency in methods of acquisition, interpretation, and analysis of images in clinical trials and specific ways to address the Food and Drug Administration regulatory expectations for PET ( 23). The Quantitative Imaging Biomarkers Alliance ( 24), using the Uniform Protocols in Clinical Trials process, has extracted content from various guidelines into a consolidated document to aid in the consensus process ( 25), and this document was used as the base material for a consensus protocol built by leaders from the United States, Europe, and Asia at the World-Wide Standardization of FDG PET Protocols for Multicenter Clinical Trials, convened by the SNM at its June 2010 meeting in Salt Lake City.

The articles by Graham et al. ( 6) and Beyer et al. ( 7) are important because they establish the scope of work before us in education and communication. They identify areas in which standardization has been easier versus areas in which it has been more difficult. These findings allow focus to be placed on what it will take for the collective efforts to make a practical impact.

Although there is a quickening sense of progress toward the desired state of having comparable quantitative imaging results across suppliers and across centers, it is equally true that there is still the daunting challenge ahead of how to promulgate standardization across our varied centers. We believe that the field is ready for this stage as it has never been before, with visible steps that indicate researchers are both willing and capable of organizing to realize the potential. Standardization is a prerequisite to establishing 18F-FDG PET/CT as an accepted quantitative imaging biomarker and will pave the way for definition of metabolic response criteria, both for use in clinical trials and for patient care. Efforts such as those by Graham and Beyer enable us to focus on the right issues, whereas the convergence and consensus-building work inform us of where we wish to arrive. What remains is for each of us to stay involved and play a part as we recognize the common good these efforts help us to do together.

  • © 2011 by Society of Nuclear Medicine

REFERENCES

  1. 1.↵
    1. Woodcock J,
    2. Woosley R
    . The FDA critical path initiative and its influence on new drug development. Annu Rev Med. 2008; 59: 1– 12.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Hunter AJ
    . The innovative medicines initiative: a pre-competitive initiative to enhance the biomedical science base of Europe to expedite the development of new medicines for patients. Drug Discov Today. 2008; 13: 371– 373.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Boellaard R
    . Standards for PET image acquisition and quantitative data analysis. J Nucl Med. 2009; 50( suppl 1): 11S– 20S.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    Performance Standards Reporting Requirements for Essential Assays in Clinical Trials. Available at: http://www.cancerdiagnosis.nci.nih.gov/scientificPrograms/pacct/assay_standards.htm. Accessed November 22, 2010.
  5. 5.↵
    1. Sanhei WR
    . Working together to enhance the efficiency of medical product development. J Nucl Med. 2008; 49( 6): 43N– 45N.
    OpenUrlFREE Full Text
  6. 6.↵
    1. Graham MM,
    2. Badawi RD,
    3. Wahl RL
    . Variations in PET/CT methodology for oncologic imaging at U.S. academic medical centers: an imaging response assessment team survey. J Nucl Med. 2011; 52: 311– 317.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. Beyer T,
    2. Czernin J,
    3. Freudenberg LS
    . Variations in clinical PET/CT operations: results of an international survey of active PET/CT users. J Nucl Med. 2011; 52: 303– 310.
    OpenUrlAbstract/FREE Full Text
  8. 8.↵
    1. Hoffman EJ,
    2. van-der-Stee M,
    3. Ricci A,
    4. et al
    . Prospects for both precision and accuracy in positron emission tomography. Ann Neurol. 1984; 15: S25– S34.
    OpenUrlCrossRefPubMed
  9. 9.↵
    1. Weber WA,
    2. Ziegler SI,
    3. Thodtmann R,
    4. Hanauske A-R,
    5. Schwaiger M
    . Reproducibility of metabolic measurements in malignant tumors using FDG PET. J Nucl Med. 1999; 40: 1771– 1777.
    OpenUrlAbstract/FREE Full Text
  10. 10.↵
    1. Young H,
    2. Baum R,
    3. Cremerius U,
    4. et al
    . Measurement of clinical and subclinical tumour response using [18F]-fluorodeoxyglucose and positron emission tomography: review and 1999 EORTC recommendations. European Organization for Research and Treatment of Cancer (EORTC) PET Study Group. Eur J Cancer. 1999; 35: 1773– 1782.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Bourguet P,
    2. Blanc-Vincent MP,
    3. Boneu A,
    4. et al
    . FNCLCC PET-Scanning Committee. Summary of the standards, options and recommendations for the use of positron emission tomography with 2-[18F]fluoro-2-deoxy-D-glucose (FDP-PET scanning) in oncology. Br J Cancer. 2003; 89( suppl 1): S84– S91.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Hallett WA
    . Quantification in clinical fluorodeoxyglucose positron emission tomography. Nucl Med Commun. 2004; 25: 647– 650.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. Feuardent J,
    2. Soret M,
    3. de Dreuille O,
    4. Foehrenbach H,
    5. Buvat I
    . Reliability of SUV estimates in FDG PET as a function of acquisition and processing protocols. IEEE Nucl Sci Symp Conf Rec. 2003; 4: 2877– 2881.
    OpenUrl
  14. 14.↵
    1. Marsden PK
    . Quantification in PET: What is it? Can we do it? Do we need it? Nucl Med Commun. 2004; 25: 635– 636.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Shankar LK,
    2. Hoffman JM,
    3. Bacharach S,
    4. et al
    . Consensus recommendations for the use of 18F-FDG PET as an indicator of therapeutic response in patients in National Cancer Institute Trials. J Nucl Med. 2006; 47: 1059– 1066.
    OpenUrlFREE Full Text
  16. 16.↵
    1. Delbeke D,
    2. Coleman RE,
    3. Guiberteau MJ,
    4. et al
    . Procedure guideline for tumor imaging with 18F-FDG PET/CT 1.0. J Nucl Med. 2006; 47: 885– 895.
    OpenUrlFREE Full Text
  17. 17.↵
    1. Hallett WA,
    2. Maguire RP,
    3. McCarthy TJ,
    4. Schmidt ME,
    5. Young H
    . Considerations for generic oncology FDG-PET/CT protocol preparation in drug development. IDrugs. 2007; 10: 791– 796.
    OpenUrlPubMed
  18. 18.↵
    1. Westerterp M,
    2. Pruim J,
    3. Oyen W,
    4. et al
    . Quantification of FDG PET studies using standardised uptake values in multi-centre trials: effects of image reconstruction, resolution and ROI definition parameters. Eur J Nucl Med Mol Imaging. 2007; 34: 393– 404.
    OpenUrl
  19. 19.↵
    1. Wahl RL,
    2. Jacene H,
    3. Kasamon Y,
    4. Lodge MA
    . From RECIST to PERCIST: evolving considerations for PET response criteria in solid tumors. J Nucl Med. 2009; 50( suppl 1): 122S– 150S.
    OpenUrlAbstract/FREE Full Text
  20. 20.↵
    Web site of the NCRI PET Research Network. Available at: http://www.ncri-pet.org.uk/. Accessed November 22, 2010.
  21. 21.↵
    1. Boellaard R,
    2. O'Doherty MJ,
    3. Weber WA,
    4. et al
    . FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging—version 1.0. Eur J Nucl Med Mol Imaging. 2010; 37: 181– 200.
    OpenUrlCrossRefPubMed
  22. 22.↵
    1. Fukukita H,
    2. Senda M,
    3. Terauchi T,
    4. et al
    . Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of version 1.0. Ann Nucl Med. 2010; 24: 325– 334.
    OpenUrlCrossRefPubMed
  23. 23.↵
    Medical News Today Web site. Two-topic imaging workshop hosted by FDA, SNM and RSNA, April 13–14. Available at: http://www.medicalnewstoday.com/articles/184334.php. Accessed November 22, 2010.
  24. 24.↵
    Radiological Society of North America Web site. Quantitative imaging and imaging biomarkers. Available at: http://www.rsna.org/research/qiba.cfm. Accessed November 22, 2010.
  25. 25.↵
    CTSA Imaging Working Group Web site. Draft proffered protocols. Available at: http://upictwiki.ctsa-imaging.org/index.php?title=Draft_Proffered_Protocols. Accessed November 22, 2010.
  • Received for publication August 9, 2010.
  • Accepted for publication August 13, 2010.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 52 (2)
Journal of Nuclear Medicine
Vol. 52, Issue 2
February 1, 2011
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Standardization of Quantitative Imaging: The Time Is Right, and 18F-FDG PET/CT Is a Good Place to Start
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Standardization of Quantitative Imaging: The Time Is Right, and 18F-FDG PET/CT Is a Good Place to Start
Andrew J. Buckler, Ronald Boellaard
Journal of Nuclear Medicine Feb 2011, 52 (2) 171-172; DOI: 10.2967/jnumed.110.081224

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Standardization of Quantitative Imaging: The Time Is Right, and 18F-FDG PET/CT Is a Good Place to Start
Andrew J. Buckler, Ronald Boellaard
Journal of Nuclear Medicine Feb 2011, 52 (2) 171-172; DOI: 10.2967/jnumed.110.081224
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • REFERENCES
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Comparison of EORTC Criteria and PERCIST for PET/CT Response Evaluation of Patients with Metastatic Colorectal Cancer Treated with Irinotecan and Cetuximab
  • Google Scholar

More in this TOC Section

  • Synergy Between Radiopharmaceutical Therapy and Immune Response: Deciphering the Underpinning Mechanisms for Future Actions
  • Gastrin-Releasing Peptide Receptor Imaging and Therapy in the Era of Personalized Medicine
  • Perspective on Pattern of Failure in Patients with Biochemical Recurrence After PSMA Radioguided Surgery
Show more INVITED PERSPECTIVE

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire