Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherBASIC SCIENCE INVESTIGATIONS

The Potential of a Radiosensitive Intracerebral Probe to Monitor 18F-MPPF Binding in Mouse Hippocampus In Vivo

Aurélie Desbrée, Mathieu Verdurand, Jeremy Godart, Albertine Dubois, Roland Mastrippolito, Frédéric Pain, Laurent Pinot, Thierry Delzescaux, Hirac Gurden, Luc Zimmer and Philippe Lanièce
Journal of Nuclear Medicine July 2008, 49 (7) 1155-1161; DOI: https://doi.org/10.2967/jnumed.107.050047
Aurélie Desbrée
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mathieu Verdurand
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jeremy Godart
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Albertine Dubois
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Roland Mastrippolito
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Frédéric Pain
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Laurent Pinot
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Thierry Delzescaux
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hirac Gurden
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Luc Zimmer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Philippe Lanièce
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

As mouse imaging has become more challenging in preclinical research, efforts have been made to develop dedicated PET systems. Although these systems are currently used for the study of physiopathologic murine models, they present some drawbacks for brain studies, including a low temporal resolution that limits the pharmacokinetic study of radiotracers. The aim of this study was to demonstrate the ability of a radiosensitive intracerebral probe to measure the binding of a radiotracer in the mouse brain in vivo. Methods: The potential of a probe 0.25 mm in diameter for pharmacokinetic studies was assessed. First, Monte Carlo simulations followed by experimental studies were used to evaluate the detection volume and sensitivity of the probe and its adequacy for the size of loci in the mouse brain. Second, ex vivo autoradiography of 5-hydroxytryptamine receptor 1A (5-HT1A) receptors in the mouse brain was performed with the PET radiotracer 2′-methoxyphenyl-(N-2′-pyridinyl)-p-18F-fluorobenzamidoethylpiperazine (18F-MPPF). Finally, the binding kinetics of 18F-MPPF were measured in vivo in both the hippocampus and the cerebellum of mice. Results: Both the simulations and the experimental studies demonstrated the feasibility of using small probes to measure radioactive concentrations in specific regions of the mouse brain. Ex vivo autoradiography showed a heterogeneous distribution of 18F-MPPF consistent with the known distribution of 5-HT1A in the mouse brain. Finally, the time–activity curves obtained in vivo were reproducible and validated the capacity of the new probe to accurately measure 18F-MPPF kinetics in the mouse hippocampus. Conclusion: Our results demonstrate the ability of the tested radiosensitive intracerebral probe to monitor binding of PET radiotracers in anesthetized mice in vivo, with high temporal resolution suited for compartmental modeling.

  • β microprobe
  • mouse
  • 18F-MPPF
  • 5-HT1A receptors
  • small-animal imaging

The last 20 y have seen the emergence of many animal models that mimic human diseases (tumor growth, neurodegenerative disease, or neuropsychiatric disorders) and are used to investigate and propose new therapeutic approaches to these diseases (1). The murine models are of great interest because they are particularly suited to the application of molecular biology strategies such as knock-out and knock-in, generating many types of transgenic strains (2,3). In following disease progression and staging therapeutic protocols in vivo, the development of specific imaging techniques is essential for proper in vivo detection and quantification of molecular changes during gene expression (4). Radioactive techniques and, more particularly, PET are efficient ways to address this problem because they can provide quantitative information about in vivo biologic processes at the molecular level. In this context, many groups have focused on adapting PET tomographs—initially developed for human imaging, and more recently for rat studies—to overcome the specific constraints of the mouse. Although some interesting and promising results have already been obtained with dedicated small-animal PET (5–7), the available scanners suffer from drawbacks such as their limited sensitivity, which impairs their temporal resolution, especially at the end of the experiment, when radioactive signals become low.

In this study, we proposed an alternative to PET for mouse brain studies—the use of a local probe sensitive to β-radioactivity (β microprobe; Biospace Lab SA). This low-cost technology, which was initially developed for PET measurements of the rat brain, has successfully been used in pharmacokinetic and pharmacodynamic studies (8–12) and for quantitative measurements of glucose metabolism or cerebral blood flow (13–15) in rats. Here, we report the development of this technology for use in mice. First, we performed theoretic experiments conceiving and characterizing a 0.25-mm-diameter prototype suited for the mouse brain. Second, we characterized 2′-methoxyphenyl-(N-2′-pyridinyl)-p-18F-fluorobenzamidoethylpiperazine (18F-MPPF) binding in the mouse brain with ex vivo autoradiography and performed an in vivo pharmacokinetics study in anesthetized mice. 18F-MPPF is a well-known 5-hydroxytryptamine receptor 1A (5-HT1A) PET radiotracer used in preclinical studies on rats (10,11,12,16,17). 18F-MPPF is particularly suited to the development of the β microprobe for mouse applications because we have already reported time–activity curves for this radioligand in the rat brain using β microprobe technology (10–12). In addition, this radiotracer is considered to be of great interest for mouse models presenting 5-HT1A deregulations such as depression (18,19).

MATERIALS AND METHODS

Monte Carlo Simulation

Simulations were performed using Geant4, developed at CERN. Initially developed for particle physics analysis, Geant4 has also proved beneficial in biomedical research (20,21). In this study, we investigated a sensitive fiber, 0.25 mm in diameter and 1 mm long, fused to a nonsensitive fiber of the same diameter. Both were simulated with polystyrene. To determine the sensitivity of the probe, we simulated 18F in brain tissues using a homogeneous cylindric source. The detection volume of the probe (volume in which the positrons are detectable; see (22) for calculation details) was computed from the Geant4 simulation using MATLAB, version 6.5 (The MathWorks, Inc.). This provided the origin coordinates of the emitted particles and determined whether the emitted particle was detected by the probe. From the Monte Carlo results, we determined a 3-dimensional (3D) matrix with 75-μm side voxels, representing the volume where the particles can be emitted. Each voxel corresponds to the ratio between particles detected by the probe and emitted particles, that is, the local detection volume ε. The sensitivity was defined as the integral of the efficiency on the volume.

Spectroscopy Setup

Preliminary experiments were performed to evaluate the optical signal delivered by the 0.25-mm-diameter probe. The mean number of photoelectrons generated by β-particles crossing the scintillating part of a fused fiber was measured from 5 fused-fiber samples. These values were compared with the mean number of photoelectrons measured from 5 reference samples based on scintillating fibers without interfaces. Double-clad optical fibers were manufactured by Bicron. Each fused fiber sample consists of a 2-mm-long BCF-12 scintillating fiber (peak emission wavelength at 435 nm) thermally fused to a 5-cm-long BCF-98 clear fiber. The end of the clear fiber was optically coupled to a photomultiplier tube (BURLE 8850; Burle Industries Inc.). A trigger signal was supplied by a second photomultiplier tube (R740; Hamamatsu) set in front of the end of the scintillating fiber and connected to a Nuclear Instrumentation Module discriminator. Fiber samples were irradiated with a 204Tl source (β-emitter, energy at maximum = 765 keV, mean energy = 244 keV) placed 5 mm from the scintillating fiber.

Determination of Experimental Probe Sensitivity

Ten probes were calibrated in 16-mL aqueous 18F solution (2.3 MBq/mL) to determine the sensitivity of the 0.25-mm-diameter 1-mm-long probes. Corresponding values were expressed in kBq/mL.

Animal Procedure

We used 4 male Swiss mice (body weight, 30 ± 3 g). They were housed at standard temperature and humidity, in artificial light (light from 8 am to 8 pm). All experiments were conducted according to European Community Council (EEC) guidelines and directives (86/09/EEC).

Synthesis of 18F-MPPF

18F-MPPF was synthesized with a radiochemical yield of 25% (decay-corrected) in an automated system (23), using the chemical pathway previously described (24). Chemical and radiochemical purity were determined by high-performance liquid chromatography (>98%). Specific activity from the injected radiotracer ranged from 79 × 103 to 332 × 103 MBq/μmol.

β microprobe System

The β microprobe is a local β-radioactivity counter that takes advantage of the limited range of β-particles within biologic tissues to define a detection volume in which the radioactivity is counted. A detailed description and discussion of the system can be found elsewhere (25,26). In this study, the probes were composed of a scintillating plastic fiber, with a 0.25-mm diameter and 1.0-mm length, fused to a clear fiber of the same diameter and mounted on a Delrin support (Luxeri). An optical guide 60 cm in length was used to connect the nonscintillating end of the probe to a photomultiplier tube (R7400P; Hamamatsu).

Kinetics of 18F-MPPF Binding

The mice were anesthetized (urethane, 1.8 g/kg intraperitoneally) and placed on a stereotactic frame; their temperature was controlled with a heating blanket (37°C ± 1°C). The stereotactic coordinates used to implant the probes in the hippocampus and in the cerebellum were based on the atlas of Paxinos and Franklin (27). The bregma point and the dura were the referenced points for anteroposterior, mediolateral, and dorsoventral coordinates. The coordinates for implantation of the probes were as follows: anteroposterior, −3.0; mediolateral, +3.0; and dorsoventral, −3.8, for the hippocampus and anteroposterior, −5.8; mediolateral, −1.0; and dorsoventral, −3.0, for the cerebellum. The cerebellum probe was implanted at an angle of 20° to allow placement of the 2 probes. Because of the sensitivity of the probe to external light, in vivo experiments were performed in darkness by covering the mouse's head with black sheets. For each acquisition, 17.5 ± 2.1 MBq of 18F-MPPF (in a volume of about 0.2 mL of saline) were injected into the tail vein over a 30-s period. The catheter was washed immediately with a bolus of saline. Radioactivity concentrations in the brain were measured during 70 min. Time–activity curve data were then decay-corrected to the time of radiotracer injection and normalized to the percentage injected dose per gram.

The binding potential (BP) value was calculated using the classic Logan graphical method for ligands with reversible binding kinetics using the cerebellum as a receptor-free reference region (28). The BP value is derived from the slope of the linear regression of the Logan plot for t > 20 min:Mathwhere Hippo(t) is the measured signal from the hippocampus (free ligand and ligand bound to 5-HT1A receptors), Cereb(t) is the measured signal from the cerebellum (reference region with free ligand and no specific binding), k3 is the rate transfer constant from the free top bound compartment (min−1), and k4 is the rate transfer constant from the free to the bound compartments.

Probe Placement Controls

After the acquisition, the anesthetized mice were killed by decapitation and the brain frozen in 2-methylbutane cooled to −40°C. Cryostat sections (20 μm thick) were cut across the hippocampus and the cerebellum and were thaw-mounted on slides. The sections were stained with cresyl blue, and the placement of the probes was matched on a stereotactic atlas of the mouse brain.

3D Reconstruction of Binding of 18F-MPPF onto 5-HT1A Receptors in Mouse Brain

Twenty minutes after the intravenous injection of 18F-MPPF with an activity of 18 MBq, the mouse was sacrificed and its brain rapidly removed and frozen for autoradiography processing. Brain sections (20 μm thick) encompassing the hippocampus and the dorsal raphe regions were cut using a cryomicrotome at −20°C, mounted on Superfrost slides (Erie Scientific Co.), quickly dried, and exposed onto autoradiographic film (BioMax MR; Kodak) for 24 h. Sections were then stained with cresyl violet. Histologic and autoradiographic images were scanned at 1,200 dpi (ImageScanner and ImageMaster LabScan, version 3.00; Amersham Biosciences Europe). Anatomic and autoradiographic sections were automatically extracted from global scans and rigidly aligned using the block-matching method (29,30) as follows. First, each anatomic section was registered with the next section, leading by propagation to a coherent 3D anatomic volume. Second, each autoradiographic section was directly coregistered with its corresponding registered histologic section from the histologic volume to generate a consistent 3D radiopharmaceutical binding volume.

RESULTS

Feasibility, Development, and Characterization of 0.25-mm-Diameter Probes

As previously reported for rat prototypes of the β microprobe (25), the feasibility of using radiosensitive probes for mouse studies was primarily investigated. Because of the small size of the mouse brain (∼0.45 g, vs. ∼2 g for the rat brain), we chose to develop a probe with 0.25-mm-diameter plastic fibers. These were chosen because plastic is compatible with brain implantations; the diameter is suited for the brain size, allows for fusion of plastic fibers, and is large enough to deliver an optical signal created by β-particles crossing the scintillating fiber; and scintillating and nonscintillating plastic fibers 0.25 mm in diameter are commercially available (Bicron). A 0.25-mm-diameter β-probe prototype was previously developed by Weber et al. (15) but was referenced only to rat applications and the use of 15O-H2O. Thus, feasibility was realized in 2 stages: in the first, the physical performances were theoretically determined; in the second, the possibility of fusing 0.25-mm-diameter fibers was tested.

Probe performance was assessed as follows. Detection volume and sensitivity (see “Materials and Methods”) were established by simulating probes with a scintillating part 0.25 mm in diameter and 1 mm in length dipped into an 18F cylindric positron source. The detection volume was 13 μL. This was compared with the size of various cerebral loci in mice. As an example, Figure 1 illustrates the detection volume of a 0.25-mm-diameter probe for 18F and the superimposition of this detection volume with mouse brain frontal sections as if the 0.25-mm-diameter probe were implanted for an 18F-tracer measurement in the hippocampus and cerebellum. In this typical configuration, the use of the 0.25-mm-diameter probe is well suited for mouse recordings because the probe detection volume fits well with both locus sizes. The detection volume appeared to be consistent with mouse cerebral structures in general, which have volumes of less than 40 μL.

FIGURE 1. 
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1. 

(A) Detection volume for 0.25-mm-diameter probe with 1.0-mm scintillating part dipped in 18F source. Scale is normalized to 1,000 events shot in a voxel. Horizontal bar scale represents 100 μm. (B) Simulation of 0.25-mm-diameter probe and its corresponding detection volume superimposed onto brain mouse frontal sections adapted from Paxinos and Frankin (27) and showing ventral hippocampus (left panel) and cerebellum (right panel).

The theoretic sensitivity of the mouse β microprobe was 0.109 cps/(kBq/mL). Because of the expected weakness of the optical signal obtained from β-particles crossing the scintillating 0.25-mm-diameter fiber, we used experimental measurements to estimate the actual sensitivity, taking into account potential signal losses expected in the complete setup (interfaces, photomultiplier efficiency, electronic threshold, and other factors). This result was imposed to establish fusion between the 0.25-mm-diameter plastic fibers. To make these new probes, we introduced and adapted a dedicated machine, previously used only to fuse fibers 0.5 and 1 mm in diameter (26). This adaptation allowed us to achieve fused samples at the price of low output (10% vs. 100% when using 0.5-mm-diameter fibers) but with an interface mechanically and optically optimized. To test this quality, we developed a specific low-light analyzer setup (see “Materials and Methods”) that allowed us to quantify the signal. The maximum, 7.8 ± 0.9 photoelectrons, and the mean, 2.6 ± 0.2 photoelectrons, represented a 10% decrease in the mean number of photoelectrons, compared with the light intensity spectrum for reference samples (with no fusion). Thus, the fused interface caused a slight loss of light, consistent with observations for fibers of higher diameter, and the choice of thermal fusion to join the plastic scintillating fibers and the optical fibers was validated. In addition, with a mean number of photoelectrons consistently higher than 1, the expected signal should be sufficient for the recording of measurements with such a probe connected to the complete setup. We tested the probe in experimental conditions using the optical guide and the high-sensitivity and low-thermal-noise photomultiplier tube initially used for rat studies (26).

To this end, 10 probes were calibrated in 16 mL of 18F aqueous solution (2.3 MBq/mL). We obtained an experimental sensitivity of 0.032 ± 0.007 cps/kBq/mL. This experimental sensitivity is more than 3 times lower than the theoretic value and, thus, more than 6 times lower than the sensitivity of the probes used for rat studies. This loss in sensitivity is a direct and expected result of the use of the optical guide, the associated connections, and the electronics threshold, which substantially reduce the signal. Whereas almost all the signal is retained using a 500-μm-diameter probe (with a mean number of 5 photoelectrons initially obtained using 18F), 60% of the signal is lost using a 250-μm-diameter probe, the sensitivity being at the limit of the recoverable signal.

Pharmacologic Validation of 0.25-mm-Diameter Probe

Before performing in vivo experiments, we determined the distribution of 18F-MPPF binding in the mouse brain by ex vivo autoradiography. This radioligand showed substantial accumulation in 5-HT1A regions such as the entorhinal cortex, the hippocampus, and the raphe (Fig. 2). In contrast, accumulation of 18F-MPPF in the cerebellum was negligible, confirming the low levels of receptor in this region. As well as confirming 18F-MPPF distribution, these findings helped to determine the optimal implantation site by allowing us to correlate the probe detection volume with the region of highest specificity in the hippocampus (Fig. 3).

FIGURE 2. 
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2. 

3D postmortem imaging of radioligand distribution in mouse brain after injection of 18F-MPPF. (A) 3D reconstruction of 18F-MPPF binding in hippocampal region. Background black and white anatomic volumetric reconstruction of cresyl violet–stained sections shows bilateral location of 5-HT1A binding in mouse hippocampus. (A1 and A2) Representative coronal sections showing labeling in posterior/ventral (A1) and anterior/dorsal (A2) hippocampus. (B) 3D reconstruction of 18F-MPPF binding centered on dorsal raphe nucleus (DRN) also showing entorhinal cortex. (B1 and B2) Representative coronal sections showing labeling in posterior (B1) and anterior (B2) DRN. Pseudocolored digitized autoradiographs illustrate level of 18F-MPPF binding and are color-coded from low (blue) to high (red) binding. Arrow labels: A = anterior; P = posterior, L = left; R = right; D = dorsal; V = ventral.

FIGURE 3. 
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3. 

Simulation of 0.25-mm-diameter probe and its corresponding detection volume for implantation in mouse hippocampus.

In vivo experiments were performed on the basis of this ex vivo validation. Figure 4 shows mean (±SEM) 18F-MPPF radioactivity kinetic curves for the hippocampus and cerebellum of mice (n = 4) and the corresponding specific binding curve deduced from subtraction of both the hippocampus and the cerebellum curves. The levels of radioactivity in the hippocampus increased over 10 min, reached a maximum, then decreased slowly with time, whereas radioactivity levels in the cerebellum peaked within 3 min after radioligand injection and then cleared rapidly. The amounts of 18F-MPPF, expressed as percentage injected dose per gram, reaching both the hippocampus and the cerebellum in mice are similar to those observed from autoradiographic data on rats (16): 0.078 ± 0.011 and 0.152 ± 0.061 for the hippocampus and 0.025 ± 0.005 and 0.036 ± 0.013 for the cerebellum, in mice and rats, respectively, at 30 min. The hippocampus-to-cerebellum ratios obtained with the mouse β microprobe were 3.06 at 15 min, 3.21 at 30 min, and 2.58 at 45 min after injection. These values are consistent with those previously obtained with the rat β microprobe (3.05, 3.65, and 3.58, respectively (24)) and autoradiography (3.05, 4.2, and 3, respectively (16)). For a quantitative comparison, we determined the BP of 18F-MPPF in the hippocampus of the mouse following the method previously proposed by Logan et al. (28) (see “Materials and Methods”): the mouse BP that we calculated was 1.75 ± 0.4. This mouse BP remains close to the rat BP value: 2.3 ± 0.6 (11).

FIGURE 4. 
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4. 

Radioactivity kinetic curves measured by β microprobe in hippocampus and cerebellum of anesthetized mice after 18F-MPPF injection and corresponding specific binding curve deduced from subtraction of both hippocampus and cerebellum curves. Each point represents mean (±SEM) of radioactivity, expressed as percentage injected dose per gram for 4 mice. Arrow indicates time of radioligand injection. Data are averaged every minute for clarity.

DISCUSSION

Since the mid 1980s, the use of mouse models has become increasingly popular for the study of disease. In 2000, more than 90% of all mammals used for research worldwide were mice (31). Recently, many conventional and transgenic models have been developed to study disorders of the human central nervous system. For example, the possibility that serotoninergic 5-HT1A deficiency plays a role in mood and anxiety disorders prompted studies to genetically manipulate 5-HT1A in mice (18,32). In this context, PET has become integral to the study of the integrative mammalian biology of disease (33). Nevertheless, although PET has already and successfully been used in mice for whole-body acquisitions, its current brain applications, requiring high spatial resolution and sensitivity, have met with some limitations. These led us to propose a mouse version of the β microprobe, which was initially designed for rat applications. This probe has specific properties allowing its use as a complement to small-animal PET in neurobiologic experiments on mice.

The aim of the present study was thus to demonstrate the potential benefits and capacity of the β microprobe for in vivo mouse experiments. To this end, we performed our study in 2 stages.

First, we designed and constructed a probe suitable for the mouse brain but limited in invasiveness. Although a 250-μm-diameter plastic probe proved suitable for mouse cerebral PET studies, we also found that a probe of this diameter had potential physical limitations. The rigidity of the probe approached the minimal threshold required for implantation in brain tissue, and the light signal delivered by the positron crossing the scintillating fiber was barely detectable with the photomultiplier tube. An elegant alternative was the use of inorganic scintillators such as lutetium oxyorthosilicate (LSO) with a larger stopping power for β-particles, allowing the probe diameter to be reduced. Using LSO, Woody et al. developed a 500-μm-diameter probe for use specifically in rats (34). However, compared with plastic probes, LSO is more sensitive not only to positrons but also to 511-keV γ-rays. The energy threshold required to eliminate this significant background noise highly reduces the sensitivity of LSO probes especially for 18F tracers, with a maximum positron energy of 635 keV. Further studies should be performed to evaluate the potential of LSO probes 0.25 mm or less in diameter in mouse applications and, in particular, the influence on probe sensitivity of β- and 511-keV γ-signal discrimination by energy threshold.

In the second stage of this study, we tested the capacity of our newly developed β microprobe prototypes to monitor the pharmacokinetics of a specific radiotracer in the brains of living mice. We used 18F-MPPF, a radiotracer that we previously used with the β microprobe in rat experiments and that has been widely validated for PET studies of 5-HT1A (17). Although it has previously been shown that regional distribution of this radioligand corresponds to the 5-HT1A distribution pattern of several species, including rats (9,10,12,16,35), cats (36), and humans (37), this study provides the first 3D reconstructions of the autoradiographic volumetric distribution of 5-HT1A in the mouse brain. These results are consistent with previous studies showing a similar 5-HT1A distribution pattern between different mammalian species and thus demonstrating the phylogenetic stability of the serotoninergic neurotransmitter systems (38). In vivo experiments were performed, and 18F-MPPF specific binding was thus estimated as the difference between the concentration of radioligand in the region of interest (hippocampus, specific plus nonspecific) and the reference region (cerebellum, nonspecific). The time–radioactivity curves obtained with the β microprobe after intravenous 18F-MPPF administration were reproducible between mice (coefficient of variation, approximately 15%), showing a clear distinction between the hippocampus and the cerebellum. The hippocampus-to-cerebellum ratio increased linearly with time, approaching a value of 3 at 15 min, consistent with previous PET studies on rats (10,11). This ratio is compatible for future radiopharmacologic studies on mice, such as studies of radiotracer displacement, competition studies, or comparisons of the BP values between groups.

Thus, several applications may be considered for this methodology. The β microprobe is a versatile tool, used in rats for pharmacokinetic, pharmacodynamic, and physiologic studies (13); for determining arterial input function for PET tracers (39); and for studies using other in vivo techniques, such as microdialysis or MRI, in combination (24). As previously discussed, quantitative analysis performed with PET cameras required an optimum balance between sensitivity and spatial resolution; the small size of mouse brain loci makes this balance difficult to achieve. Consequently, only a few studies have reported the use of PET cameras in mouse brain studies. Therefore, the β microprobe provides an attractive alternative to animal PET scanners. Although the β microprobe only defines a detection volume surrounding the radiosensitive probe rather than delivering images, our findings demonstrate that 18F-MPPF kinetic studies can be performed on live mice. Similarly to studies on rats, the β microprobe has several advantages in mouse studies: it is dynamic, acquiring kinetic data with high temporal resolution (every second) and thus allowing physiologic and pharmacologic processes to be measured; it is sensitive, detecting picomolar concentrations of radioligand in the brain; and although more often producing semiquantitative data, it is potentially quantitative.

CONCLUSION

This is the first study to establish the β microprobe as a tool sufficiently sensitive to measure the specific binding of 18F-MPPF in the hippocampus of anesthetized mice. Our experimental results, together with our initial simulation studies, demonstrate that the probe is sensitive and selective and thus can be used for radiopharmacologic studies of PET radiotracer binding in the mouse brain. In particular, this new functional imaging approach will be invaluable for studies of serotonergic function in conventional or knock-out models of depression. Moreover, this methodology can be used to address a wide range of issues relevant to the PET exploration of neurotransmitter systems in mouse models of neurologic or psychiatric diseases.

Acknowledgments

We are grateful to Luc Magnier from Animage for his expert technical assistance. We thank Rhône-Alpes Genopole and Fondation Rhône-Alpes Futur, funded by the Réseau National des Genopoles. This work was supported by the academic funding program “Imagerie du Petit Animal” (Centre National de la Recherche Scientifique, Commissariat à l'Energie Atomique).

Footnotes

  • COPYRIGHT © 2008 by the Society of Nuclear Medicine, Inc.

References

  1. 1.↵
    Koo V, Hamilton PW, Williamson K. Non-invasive in vivo imaging in small animal research. Cell Oncol. 2006;28:127–139.
    OpenUrlPubMed
  2. 2.↵
    Paigen K. A miracle enough: the power of mice. Nat Med. 1995;1:215–220.
    OpenUrlCrossRefPubMed
  3. 3.↵
    Gao X, Kemper A, Popko B. Advanced transgenic and gene targeting approaches. Neurochem Res. 1999;24:1181–1188.
    OpenUrlCrossRefPubMed
  4. 4.↵
    Cherry SR. In vivo molecular and genomic imaging: new challenges for imaging physics. Phys Med Biol. 2004;49:R13–R48.
    OpenUrlCrossRefPubMed
  5. 5.↵
    Massoud TF, Gambhir SS. Molecular imaging in living subjects: seeing fundamental biological processes in a new light. Genes Dev. 2003;17:545–580.
    OpenUrlFREE Full Text
  6. 6.
    Gambhir SS, Barrio JR, Phelps ME, et al. Imaging adenoviral-directed reporter gene expression in living animals with positron emission tomography. Proc Natl Acad Sci USA. 1999;96:2333–2338.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    Wyss MT, Honer M, Schubiger PA, Ametamey SM. NanoPET imaging of [18F]fluoromisonidazole uptake in experimental mouse tumours. Eur J Nucl Med Mol Imaging. 2006;33:311–318.
    OpenUrlCrossRefPubMed
  8. 8.↵
    Ginovart N, Sun W, Wilson A, Houle S, Kapur S. Quantitative validation of an intracerebral beta-sensitive microprobe system to determine in vivo drug-induced receptor occupancy using [11C]raclopride in rats. Synapse. 2004;52:89–99.
    OpenUrlCrossRefPubMed
  9. 8.
    Zimmer L, Hassoun W, Pain F, et al. SIC, an intracerebral beta+-range-sensitive probe for radiopharmacology investigations in small laboratory animals: binding studies with [11C]-raclopride. J Nucl Med. 2002;43:227–233.
    OpenUrlAbstract/FREE Full Text
  10. 9.↵
    Zimmer L, Pain F, Mauger G, et al. The potential of the beta-MICROPROBE, an intracerebral radiosensitive probe, to monitor the [18F]MPPF binding in the rat dorsal raphe nucleus. Eur J Nucl Med Mol Imaging. 2002;29:1237–1247.
    OpenUrlCrossRefPubMed
  11. 10.↵
    Zimmer L, Mauger G, Le Bars D, Bonmarchand G, Luxen A, Pujol J. Effect of endogenous serotonin on the binding of the 5-hT1A PET ligand 18F-MPPF in the rat hippocampus: kinetic beta measurements combined with microdialysis. J Neurochem. 2002;80:278–286.
    OpenUrlCrossRefPubMed
  12. 11.↵
    Rbah L, Leviel V, Zimmer L. Displacement of the PET ligand 18F-MPPF by the electrically evoked serotonin release in the rat hippocampus. Synapse. 2003;49:239–245.
    OpenUrlCrossRefPubMed
  13. 12.↵
    Zimmer L, Riad M, Rbah L, et al. Toward brain imaging of serotonin 5-HT1A autoreceptor internalization. Neuroimage. 2004;22:1421–1426.
    OpenUrlCrossRefPubMed
  14. 13.↵
    Pain F, Besret L, Vaufrey F, et al. In vivo quantification of localized neuronal activation and inhibition in the rat brain using a dedicated high temporal resolution beta-sensitive MICROPROBE. Proc Natl Acad Sci USA. 2002;99:10807–10812.
    OpenUrlAbstract/FREE Full Text
  15. 14.
    Millet P, Moulin Sallanon M, Petit J, et al. In vivo measurement of glucose utilization in rats using a beta-Microprobe: direct comparison with autoradiography. J Cereb Blood Flow Metab. 2004;24:1015–1024.
    OpenUrlCrossRefPubMed
  16. 15.↵
    Weber B, Spath N, Wyss M, et al. Quantitative cerebral blood flow measurements in the rat using a beta-probe and H215O. J Cereb Blood Flow Metab. 2003;23:1455–1460.
    OpenUrlPubMed
  17. 16.↵
    Plenevaux A, Weissmann D, Aerts J, et al. Tissue distribution, autoradiography, and metabolism of (4-2′-methoxyphenyl)-1-[2′(N-2-pyridinyl)-p-[18F]fluorobenzamido]-ethyl]piperazine, p-[18F]-MPPF, a new serotonin 5-HT1A antagonist for positron emission tomography: an in vivo study in rats. J Neurochem. 2000;75:803–811.
    OpenUrlCrossRefPubMed
  18. 17.↵
    Aznavour N, Zimmer L. [18F]MPPF as a tool for the in vivo imaging of 5-HT1A receptor in animal and human brain. Neuropharmacology. 2007;52:695–707.
    OpenUrlCrossRefPubMed
  19. 18.↵
    Toth M. 5-HT1A receptor knockout mouse as a genetic model of anxiety. Eur J Pharmacol. 2003;463:177–184.
    OpenUrlCrossRefPubMed
  20. 19.↵
    Overstreet DH, Commisaris RC, De La Garza R, File SE, Knapp DJ, Seiden LS. Involvement of 5-HT1A receptors in animal tests of anxiety and depression: evidence from genetic models. Stress. 2003;6:101–110.
    OpenUrlPubMed
  21. 20.↵
    Agostinelli S, Allison J, Amako K, et al. Geant4: a simulation toolkit. Nucl Instrum Methods Phys Res A. 2003;506:250–303.
    OpenUrlCrossRef
  22. 21.↵
    Jan S, Santin G, Strul D, et al. GATE: a simulation toolkit for PET and SPECT. Phys Med Biol. 2004;49:4543–4561.
    OpenUrlCrossRefPubMed
  23. 22.↵
    Desbree A, Pain F, Gurden H, et al. A new multimodality system for quantitative in vivo studies in small animals: combination of nuclear magnetic resonance and the radiosensitive beta-MicroProbe. IEEE Trans Nucl Sci. 2005;52:1281–1287.
    OpenUrlCrossRef
  24. 23.↵
    Le Bars D, Bonmarchand G, Alvarez J, Lemaire C, Mosdzianowski C. New automation of [18F]-MPPF using a coincidence synthesizer [abstract]. J Labelled Comp Radiopharm. 2001;44(suppl):S1045.
    OpenUrl
  25. 24.↵
    Desbree A, Rbah L, Langlois J, et al. Simultaneous in vivo magnetic resonance imaging and radioactive measurements by the beta-Microprobe. Eur J Nucl Med Mol Imaging. 2007;34:1868–1872.
    OpenUrlCrossRefPubMed
  26. 25.↵
    Pain F, Lanièce P, Mastrippolito R, et al. SIC, an intracerebral radiosensitive probe for in vivo neuropharmacology investigations in small laboratory animals: theoretical considerations and physical characteristics. IEEE Trans Nucl Sci. 2000;47:25–32.
    OpenUrlCrossRef
  27. 26.↵
    Pain F, Lanièce P, Mastrippolito R, et al. SIC, an intracerebral radiosensitive probe for in vivo neuropharmacology investigations in small laboratory animals: first prototype design characterisation and in vivo evaluation. IEEE Trans Nucl Sci. 2002;49:822–826.
    OpenUrlCrossRef
  28. 27.↵
    Paxinos G, Frankin KBJ. The Mouse Brain in Stereotaxic Coordinates. San Diego, CA: Academic Press; 2001.
  29. 28.↵
    Logan J, Fowler JS, Volkow ND, et al. Graphical analysis of reversible radioligand binding from time-activity measurements applied to [N-11C-methyl]-(−)-cocaine PET studies in human subjects. J Cereb Blood Flow Metab. 1990;10:740–747.
    OpenUrlCrossRefPubMed
  30. 29.↵
    Prima S, Ourselin S, Ayache N. Computation of the mid-sagittal plane in 3-D brain images. IEEE Trans Med Imaging. 2002;21:122–138.
    OpenUrlCrossRefPubMed
  31. 30.↵
    Dubois A, Dauguet J, Herard AS, et al. Automated three-dimensional analysis of histological and autoradiographic rat brain sections: application to an activation study. J Cereb Blood Flow Metab. 2007;27:1742–1755.
    OpenUrlCrossRefPubMed
  32. 31.↵
    Malakoff D. The rise of the mouse, biomedicine's model mammal. Science. 2000;288:248–253.
    OpenUrlAbstract/FREE Full Text
  33. 32.↵
    Gingrich JA, Hen R. Dissecting the role of the serotonin system in neuropsychiatric disorders using knockout mice. Psychopharmacology (Berl). 2001;155:1–10.
    OpenUrlCrossRefPubMed
  34. 33.↵
    Phelps ME. PET: the merging of biology and imaging into molecular imaging. J Nucl Med. 2000;41:661–681.
    OpenUrlAbstract/FREE Full Text
  35. 34.↵
    Woody CL, Stoll SP, Schlyer DJ, et al. A study of scintillation beta microprobes. IEEE Trans Nucl Sci. 2002;49:2208–2212.
    OpenUrlCrossRef
  36. 35.↵
    Riad M, Zimmer L, Rbah L, Watkins KC, Hamon M, Descarries L. Acute treatment with the antidepressant fluoxetine internalizes 5-HT1A autoreceptors and reduces the in vivo binding of the PET radioligand [18F]MPPF in the nucleus raphe dorsalis of rat. J Neurosci. 2004;24:5420–5426.
    OpenUrlAbstract/FREE Full Text
  37. 36.↵
    Aznavour N, Rbah L, Riad M, et al. PET imaging study of 5-HT(1A) receptors in cat brain after acute and chronic fluoxetine treatment. Neuroimage. 2006;33:834–842.
    OpenUrlCrossRefPubMed
  38. 37.↵
    Costes N, Merlet I, Zimmer L, et al. Modeling [18F]MPPF positron emission tomography kinetics for the determination of 5-hydroxytryptamine(1A) receptor concentration with multiinjection. J Cereb Blood Flow Metab. 2002;22:753–765.
    OpenUrlPubMed
  39. 38.↵
    Lanfumey L, Hamon M. 5-HT1 receptors. Curr Drug Targets CNS Neurol Disord. 2004;3:1–10.
    OpenUrlPubMed
  40. 39.↵
    Pain F, Laniece P, Mastrippolito R, Gervais P, Hantraye P, Besret L. Arterial input function measurement without blood sampling using a beta-microprobe in rats. J Nucl Med. 2004;45:1577–1582.
    OpenUrlAbstract/FREE Full Text
  • Received for publication January 9, 2008.
  • Accepted for publication March 4, 2008.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 49 (7)
Journal of Nuclear Medicine
Vol. 49, Issue 7
July 2008
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The Potential of a Radiosensitive Intracerebral Probe to Monitor 18F-MPPF Binding in Mouse Hippocampus In Vivo
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
The Potential of a Radiosensitive Intracerebral Probe to Monitor 18F-MPPF Binding in Mouse Hippocampus In Vivo
Aurélie Desbrée, Mathieu Verdurand, Jeremy Godart, Albertine Dubois, Roland Mastrippolito, Frédéric Pain, Laurent Pinot, Thierry Delzescaux, Hirac Gurden, Luc Zimmer, Philippe Lanièce
Journal of Nuclear Medicine Jul 2008, 49 (7) 1155-1161; DOI: 10.2967/jnumed.107.050047

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
The Potential of a Radiosensitive Intracerebral Probe to Monitor 18F-MPPF Binding in Mouse Hippocampus In Vivo
Aurélie Desbrée, Mathieu Verdurand, Jeremy Godart, Albertine Dubois, Roland Mastrippolito, Frédéric Pain, Laurent Pinot, Thierry Delzescaux, Hirac Gurden, Luc Zimmer, Philippe Lanièce
Journal of Nuclear Medicine Jul 2008, 49 (7) 1155-1161; DOI: 10.2967/jnumed.107.050047
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • 11C-Methionine PET of Myocardial Inflammation in a Rat Model of Experimental Autoimmune Myocarditis
  • Counting Rate Characteristics and Image Distortion in Preclinical PET Imaging During Radiopharmaceutical Therapy
  • Design and Fabrication of Kidney Phantoms for Internal Radiation Dosimetry Using 3D Printing Technology
Show more Basic Science Investigations

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire