JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Palestro, C. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Palestro, C. J.
Journal of Nuclear Medicine Vol. 48 No. 3 332-334
© 2007 by Society of Nuclear Medicine


Invited Perspective

In Vivo Leukocyte Labeling: The Quest Continues

Christopher J. Palestro

Long Island Jewish Medical Center, New Hyde Park, New York

Correspondence: For correspondence or reprints contact: Christopher J. Palestro, MD, Division of Nuclear Medicine, Long Island Jewish Medical Center, 270-05 76th Ave., New Hyde Park, NY 11040. E-mail: Palestro{at}lij.edu

The development of in vitro methods to radiolabel and image leukocytes that migrate to sites of infection was a significant milestone in the history of nuclear medicine (1). Even today, in vitro labeled leukocyte imaging remains the radionuclide gold standard for the imaging of most infections in the immunocompetent population. However, there are significant limitations to the technique. In vitro labeling is labor-intensive, is not always available, and requires direct handling of blood products. The need to perform complementary marrow or bone imaging adds complexity and expense to the procedure and is inconvenient for patients (2).

See page 337

Considerable effort has been expended on developing in vivo methods of labeling leukocytes that would overcome the limitations of in vitro methods. Although limited investigations of leukocyte-avid peptides in humans have shown promise, most investigations have focused on antigranulocyte antibodies (319). Unfortunately, these techniques have met with only modest success. One of the first agents investigated was BW 250/183 (Granuloscint; CISBio International), a murine monoclonal IgG1 antibody that binds to the NCA-95 antigen on leukocytes. About 10% of the injected activity is neutrophil bound at 45 min after injection, with 20% of the activity circulating freely in the blood (5). Although studies usually become positive by 6 h after injection, delayed imaging at 24 h increases sensitivity. Up to 40% of the injected dose accumulates in bone marrow, potentially obscuring small foci of infection. Sensitivity for osteomyelitis ranges from about 70% in the hips to 100% in the distal lower extremities, perhaps reflecting easier detection with decreasing amounts of marrow distally (5,7). A disadvantage of BW 250/183 is the incidence of a dose-dependent human antimurine antibody response, which ranges from less than 5% in patients receiving a single dose of the antibody to more than 30% in patients receiving repeated injections (8).

Sulesomab (Leukoscan; Immunomedics) is a 50-kDa-antigen–binding fragment (Fab') of a murine monoclonal antibody of the IgG1 class that binds to the NCA-90 antigen on leukocytes (9). A significant advantage of this agent is the lack of a human antimurine antibody response. Uptake mechanisms include binding to circulating neutrophils and to leukocytes already present at the site of infection (6). Clinical results have been variable. In 1 investigation of suspected musculoskeletal infection, the sensitivity, specificity, and accuracy of the agent were 90%–93%, 85%–89%, and 88%–90%, respectively (12,13). In another series, however, the sensitivity, specificity, and accuracy were 76%, 84%, and 78%, respectively (11). In 1 series of people with diabetes and with suspected pedal osteomyelitis, the agent was 100% sensitive and specific, whereas another group of investigators reported a sensitivity of 80% and a specificity of 67% (13,14).

99mTc-Fanolesomab (NeutroSpec; Palatin Technologies) is a murine IgM antibody that binds to the CD15 antigen on human neutrophils, eosinophils, and lymphocytes. The antibody binds at a higher frequency to neutrophils than to any other cell type. Binding increases proportionately with increasing numbers of circulating neutrophils and is upregulated with neutrophil activation. Fanolesomab binds to circulating neutrophils and to neutrophils and neutrophilic debris containing CD-15 receptors and already sequestered in the focus of infection (15,16).

In clinical trials, 99mTc-fanolesomab accurately diagnosed appendicitis and appendicular osteomyelitis and was approved for use in the United States in 2004 (17,18). In December 2005, it was withdrawn as a result of postmarketing reports of serious and life-threatening cardiopulmonary events, including 2 fatalities, which occurred shortly after administration. The explanation for these events is as yet unknown, and the future of 99mTc-fanolesomab is uncertain (19).

Eschewing antigranulocyte antibodies, Bleeker-Rovers et al. (20) chose to investigate a small protein, interleukin 8 (IL-8), and the results of that investigation are reported on pages 337–343 of this issue of The Journal of Nuclear Medicine. IL-8, which has a molecular mass of 8.5 kDa, binds with a high affinity to the CXC1 and CXC2 receptors present on neutrophils (21,22). Markedly reduced abscess uptake of 99mTc-IL-8 in neutropenic rabbits has been reported (23). The success of leukocyte imaging is also dependent on neutrophils, which are the predominant leukocytes labeled in vitro (2). Therefore, with reasonable confidence, researchers can predict a priori how IL-8 will perform in a given situation and design clinical investigations accordingly. For example, leukocyte imaging is not very useful for diagnosing opportunistic infections or spinal osteomyelitis (2). (Indeed, for the 1 patient with spinal infection in the investigation of Bleeker-Rovers et al. (20), the IL-8 results were false-negative.) Designing clinical trials to study these entities with IL-8 would likely be neither cost-effective nor fruitful. Efforts would be better focused on appendicular osteomyelitis, prosthetic vascular graft infection, and inflammatory bowel disease, entities for which the utility of leukocyte imaging is well documented.

A significant disadvantage of leukocyte imaging is the labeling process itself. Safety concerns aside, the procedure is time-consuming, is laborious, and requires skilled personnel. Even when labeling is performed on site, the test is usually performed only during routine working hours. At sites that depend on outside radiopharmacies to perform labeling, availability may be even more restricted, especially in rural locations, where the distance between a medical center and a radiopharmacy can make performance of the test all but impossible. If commercially available cold IL-8 were available in kit form and if the radiolabeling were performed as described by Bleeker-Rovers et al. (20), the availability of the test could dramatically expand.

The results obtained with IL-8 in the investigation of Bleeker-Rovers et al. (20) were in agreement with the final diagnosis in 18 of 20 patients studied, a finding that is encouraging. Given the small number of patients studied and the preponderance of referrals for suspected musculoskeletal infection, the issue of efficacy really cannot be addressed. This investigation is best viewed as proof of principle; in the population studied, the agent was safe and accurate and warrants further investigation.

Safety concerns are, perhaps, the major impetus for developing in vivo leukocyte-labeling methods. An agent that can be safely injected directly into a patient, obviating direct contact with blood, would be a significant improvement over current methodology. Data on the safety of IL-8 in humans are scant. In 11 patients who received 50–100 µg of 131I-IL-8, there was a transient decrease in the numbers of circulating leukocytes, with a return to baseline levels within about 1 h (24). In the study of Bleeker-Rovers et al. (20), a much smaller dose was used, and no significant changes in leukocyte counts were observed. Facial flushing in 1 patient was the only side effect noted. Although the drug is apparently safe, IL-8 has been studied in fewer than 50 patients. No significant safety issues arose during clinical trials of 99mTc-fanolesomab, in which more than 500 patients were studied. These issues became apparent only after the drug was in clinical use and several thousand patients had been injected!

In their preliminary investigation, Bleeker-Rovers at al (20) report on an agent that may be able to replace in vitro labeled leukocyte imaging for many indications. Much work remains, however, if IL-8 is to avoid the fate of many of its predecessors. The key to determining its true value is well-designed clinical trials. No single agent is equally useful for all situations; therefore, investigations in which entry criteria are broad, such as "suspected infection," are not ideal. Focused investigations of specific conditions, such as prosthetic joint infection, diabetic foot infection, and inflammatory bowel disease, although more costly, will provide far more meaningful information about the merits of IL-8.

Appropriate imaging protocols also need to be developed. From the article of Bleeker-Rovers et al. (20), one could conclude that a single set of images obtained within a few hours after injection are sufficient. Similar conclusions initially were drawn about fanolesomab; subsequent data, however, indicated that delayed imaging was sometimes required (25). Early and late imaging should be incorporated into future IL-8 investigations.

Equally important is the "standard of truth" against which IL-8 is judged. Regardless of their flaws or the difficulties encountered in obtaining them, histopathology or microbiology evaluations are the diagnostic gold standards for most diseases, and a requirement that they be obtained should be part of investigational protocols.

Because IL-8 imaging is a potential replacement for leukocyte imaging, intraindividual comparisons of IL-8 and leukocytes would further strengthen conclusions about the ultimate worth of IL-8.

Given the unfortunate events associated with 99mTc-fanolesomab, the importance of thoroughly investigating the safety of IL-8 cannot be overemphasized. It will not be sufficient to demonstrate that IL-8 is safe for a 1-time use. It is not uncommon for patients to undergo radionuclide infection imaging procedures on multiple occasions, and it is important to confirm that repeated injections will compromise neither patient safety nor diagnostic accuracy.

The role of PET is increasing exponentially, and the importance of 18F-FDG PET for the imaging of infection and inflammation is now well appreciated (26). 18F-FDG, however, is a beginning, not an end. Investigators are already exploring the potential of labeling leukocytes in vitro with 18F-FDG (27). The next logical step is the development of an in vivo method of labeling leukocytes with a positron emitter. Perhaps this goal can be accomplished with IL-8; at the very least, it merits consideration.

FOOTNOTES

COPYRIGHT © 2007 by the Society of Nuclear Medicine, Inc.

References

  1. Thakur ML, Lavender JP, Arnot RN, Silvester DJ, Segal AW. Indium-111-labeled autologous leukocytes in man. J Nucl Med. 1977;18:1014–1021.[Abstract/Free Full Text]
  2. Love C, Palestro CJ. Radionuclide imaging of infection. J Nucl Med Technol. 2004;32:47–57.[Abstract/Free Full Text]
  3. Palestro CJ, Weiland FL, Seabold JE, et al. Localizing infection with a technetium labeled peptide: initial results. Nucl Med Commun. 2001;22:695–701.[Medline]
  4. Becker W, Meller J. The role of nuclear medicine in infection and inflammation. Lancet Infect Dis. 2001;1:326–333.[CrossRef][Medline]
  5. Weiner RE, Thakur ML. Imaging infection/inflammations. Q J Nucl Med. 1999;43:2–8.[Medline]
  6. Becker W, Goldenberg DM, Wolf F. The use of monoclonal antibodies and antibody fragments in the imaging of infectious lesions. Semin Nucl Med. 1994;24:142–153.[CrossRef][Medline]
  7. Becker W. The contribution of nuclear medicine to the patient with infection. Eur J Nucl Med. 1995;22:1195–1211.[Medline]
  8. Gratz S, Behr T, Herrmann A, et al. Intraindividual comparison of 99mTc-labelled anti-SSEA-1 antigranulocyte antibody and 99mTc-HMPAO labeled white blood cells for the imaging of infection. Eur J Nucl Med. 1998;25:386–393.[CrossRef][Medline]
  9. Becker W, Bair J, Behr T, et al. Detection of soft-tissue infections and osteomyelitis using a technetium-99m-labeled anti-granulocyte monoclonal antibody fragment. J Nucl Med. 1994;35:1436–1443.[Abstract/Free Full Text]
  10. Becker WS, Saptogino A, Wolf FG. The single late 99Tcm-granulocyte antibody scan in inflammatory diseases. Nucl Med Commun. 1992;13:186–192.[Medline]
  11. Gratz S, Schipper ML, Dorner J, et al. Leukoscan for imaging infection in different clinical settings: a retrospective evaluation and extended review of the literature. Clin Nucl Med. 2003;28:267–276.[CrossRef][Medline]
  12. Becker W, Palestro CJ, Winship J, et al. Rapid diagnosis of infections with a monoclonal antibody fragment (Leukoscan). Clin Orthop. 1996;329:263–272.
  13. Hakki S, Harwood SJ, Morrissey MA, Camblin JG, Laven DL, Webster WB Jr. Comparative study of monoclonal antibody scan in diagnosing orthopaedic infection. Clin Orthop Relat Res. 1997;Feb:275–285.
  14. Deveillers A, Garin E, Polard JL, et al. Comparison of Tc-99m-labelled antileukocyte fragment Fab' and Tc-99m-HMPAO leukocyte scintigraphy in the diagnosis of bone and joint infections: a prospective study. Nucl Med Commun. 2000;21:747–753.[CrossRef][Medline]
  15. Thakur ML, Marcus CS, Henneman P, et al. Imaging inflammatory diseases with neutrophil-specific technetium-99m-labeled monoclonal antibody anti-SSEA-1. J Nucl Med. 1996;37:1789–1795.[Abstract/Free Full Text]
  16. Love C, Palestro CJ. 99mTc-Fanolesomab. IDrugs. 2003;6:1079–1085.[Medline]
  17. Rypins EB, Kipper SL, Weiland F, et al. 99mTc-Anti-CD15 monoclonal antibody (LeuTech) imaging improves diagnostic accuracy and clinical management in patients with equivocal presentation of acute appendicitis. Ann Surg. 2002;235:232–239.[Medline]
  18. Palestro CJ, Kipper SL, Weiland FL, Love C, Tomas MB. Osteomyelitis: diagnosis with 99mTc-labeled antigranulocyte antibodies compared with diagnosis with indium-111-labeled leukocytes—initial experience. Radiology. 2002;223:758–764.[Abstract/Free Full Text]
  19. Love C, Tronco GG, Palestro CJ. 99mTc-Fanolesomab: a new agent for imaging infection and inflammation. Q J Nucl Med Mol Imaging. 2006;50:113–120.[Medline]
  20. Bleeker-Rovers CP, Rennen HJJM, Boerman OC, et al. 99mTc-Labeled interleukin 8 for the scintigraphic detection of infection and inflammation: first clinical evaluation. J Nucl Med. 2007;48:337–343.
  21. Lee J, Horuk R, Rice GC, Bennett GL, Camerato T, Wood WI. Characterization of two high affinity human interlukin-8 receptors. J Biol Chem. 1992;267:16283–16287.[Abstract/Free Full Text]
  22. Patel L, Charlton SJ, Chambers JK, Macphee CH. Expression and functional analysis of chemokine receptors in human peripheral blood leukocyte populations. Cytokine. 2001;14:27–36.[CrossRef][Medline]
  23. Rennen HJ, Boerman OC, Oyen WJ, van der Meer JW, Corstens FH. Specific and rapid scintigraphic detection of infection with 99mTc-labeled interleukin 8. J Nucl Med. 2001;42:117–123.[Abstract/Free Full Text]
  24. Gross MD, Shapiro B, Fig LM, Steventon R, Skinner RW, Hay RV. Imaging of human infection with 131I-labeled recombinant human interleukin 8. J Nucl Med. 2001;42:1656–1659.[Abstract/Free Full Text]
  25. Tronco GG, Love C, Rini JN, et al. Diagnosing prosthetic vascular graft infection with the antigranulocyte antibody 99mTc-fanolesomab. Nucl Med Commun. In press.
  26. Love C, Tomas MB, Tronco GG, Palestro CJ. Imaging infection and inflammation with 18F-FDG-PET. Radiographics. 2005;25:1357–1368.[Abstract/Free Full Text]
  27. Rini JN, Bhargava KK, Tronco GG, et al. 18F-FDG in vitro labeled autologous human leukocytes versus 111In-labeled leukocytes for the detection of infection. Radiology. 2006;238:978–987.[Abstract/Free Full Text]
Received for publication October 17, 2006. Accepted for publication October 24, 2006.


Related articles in JNM:

This Month in JNM

JNM 2007 48: 9a-10a. [Full Text]  




This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Palestro, C. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Palestro, C. J.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE