Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherBasic Science Investigations

Residualizing Iodine Markedly Improved Tumor Targeting Using Bispecific Antibody-Based Pretargeting

Frank G. van Schaijk, Matthias Broekema, Egbert Oosterwijk, Juliette E.M. van Eerd, Bill J. McBride, David M. Goldenberg, Frans H.M. Corstens and Otto C. Boerman
Journal of Nuclear Medicine June 2005, 46 (6) 1016-1022;
Frank G. van Schaijk
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Matthias Broekema
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Egbert Oosterwijk
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Juliette E.M. van Eerd
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Bill J. McBride
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
David M. Goldenberg
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Frans H.M. Corstens
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Otto C. Boerman
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Previous studies have shown that pretargeting allows rapid visualization of renal cell carcinomas (RCC) with an 111In-labeled bivalent peptide. For radioimmunotherapy, a β-emitting radionuclide labeled to a bivalent peptide is required. Therapeutic efficacy of these radionuclides depends on the Emax, physical half-life, and residence time of the radiolabel in the tumor. The 131I radiolabel generally clears rapidly from the tumor after internalization and subsequent degradation of the bivalent l-amino acid peptide (l-a.a. peptide) in the tumor cells. To improve the residence time of the iodine label in the tumor, a new bivalent peptide was synthesized that is peptidase resistant and consists of 4 d-amino acids (d-a.a. peptide). Here we investigated the characteristics of the residualizing iodine label in SK-RC-52 RCC tumors. Methods: The d-a.a. peptide was manually synthesized according to standard solid-phase Fmoc/HBTU (2-[1H-benzotriazole-1-yl]-1,1,3,3-tetramethyluronium hexafluorophosphate) chemistry. The uptake and retention in the tumor of 111In-/125I-labeled bivalent peptides (l-a.a. peptide and d-a.a. peptide) were studied in female BALB/c athymic mice with subcutaneous SK-RC-52 RCC tumors. Tumors were pretargeted with the bispecific monoclonal antibody (bs-mAb) G250xDTIn-1 and, 72 h later, mice were injected intravenously with one of both radiolabeled peptides. The effect of bs-mAb—diDTPA—bs-mAb (DTPA is diethylenetriaminepentaacetic acid) bridging at the tumor cell surface on the internalization of the bs-mAb—diDTPA complex was investigated in SK-RC-52 tumor-bearing mice. Results: The maximum uptake and retention of 125I-labeled l-a.a. peptide in the tumor were significantly lower compared with that of the 111In-labeled l-a.a. peptide. In contrast, the tumor uptake and retention of the 125I-labeled d-a.a. peptide) were similar to that of the 111In-labeled l-a.a. peptide but were superior at later time points. The biodistribution of the radioiodinated d-a.a. peptide was highly similar to that of the 111In-labeled d-a.a. peptide, and both radiolabeled peptides were retained significantly better in the tumor than the 111In-labeled l-a.a. peptide. bs-mAb—diDTPA—bs-mAb bridge formation did not affect internalization of the bs-mAb—diDTPA complex. Conclusion: Uptake and retention in the tumor of the iodinated peptide after pretargeting with a bs-mAb can be significantly improved using d-a.a. peptides. Accordingly, the radiation dose to the tumor, correlating with the therapeutic efficacy of pretargeted RCC, can be enhanced substantially.

  • pretargeting strategy
  • residualizing iodine
  • internalization
  • bs-mAb G250xDTIn-1

Monoclonal antibodies (mAbs) directed against tumor-associated antigens have excellent characteristics to target tumor cells selectively (1–3). So far, radioimmunotherapy (RIT) has only induced significant therapeutic effect in patients with hematologic tumors, presumably due to their relatively high radiosensitivity (4,5). The combination of the long circulating half-life of the radiolabeled mAb and the radiosensitivity of the bone marrow limits the radioactive doses of labeled antibodies that can be administered safely (6,7). The separation of the mAb (targeting agent) and the radionuclide (effector agent) as proposed by Goodwin et al. (8,9) could improve the efficacy of RIT. In this approach a nonradiolabeled bispecific monoclonal antibody (bs-mAb) with antitumor-associated antigen (TAA) and antihapten specificity is injected in the first phase. In the second phase a radiolabeled hapten is administered, which is trapped in the tumor by the bs-mAb.

We have developed an effective pretargeting system based on a biologically produced bs-mAb (antirenal cell carcinoma [RCC] x anti-DTPA(In) bs-mAb: G250xDTIn-1) and an 111In-labeled bivalent l-amino acid peptide (l-a.a. peptide) (Ac-Phe-Lys(DTPA)-Tyr-Lys(DTPA)-NH2) (DTPA is diethylenetriaminepentaacetic acid) (10). In previous studies we have shown that with this strategy relatively high uptake of the 111In label in various RCC mouse models can be achieved (maximum uptake from 54.1 to 287 %ID/g) (%ID/g is percentage injected dose per gram) (11). The β-emitting radionuclide 131I is a commonly used radionuclide for RIT. Unfortunately, after internalization and degradation of the 131I-labeled peptide in the lysosomes, the metabolite 131I-Tyr is rapidly cleared from tumor cells (12–15). In contrast, peptides labeled with a radiometal via a substituted aminopolycarboxylate (such as DTPA or 1,4,7,10-tetraazacyclododecane-N,N′,N″,N‴-tetraacetic acid [DOTA]) showed enhanced retention in tumor cells after internalization (16). The metabolite Lys-chelate(metal) is trapped in the lysosomes because it cannot pass the lysosomal membrane (17,18). Stein et al. (19,20) and Govindan et al. (21) postulated that radioiodine can also be trapped in the lysosomes when the tyrosine residue is conjugated to the DTPA-substituted lysine residue via a peptidase-resistant peptide bond by using the d-analogs of both amino acid residues involved. In the present study, these findings were exploited to enhance the tumor retention of 131I-labeled peptide in the pretargeting approach. A new bivalent tetrapeptide was synthesized, consisting of 4 d-amino acid (d-a.a.) residues and both lysine residues were conjugated with a DTPA moiety (d-a.a. peptide). These d-a.a. peptide bonds are resistant to endo- and exopeptidases (22). Because such a peptide cannot be degraded in the lysosomes, the 131I label will be retained in the tumor. In these studies the iodinated d-a.a. bivalent peptide was studied in the pretargeting strategy of SK-RC-52 tumors.

Various studies have demonstrated markedly improved tumor targeting with a bivalent peptide instead of a monovalent hapten in the pretargeting strategy (23–27). Internalization of the bs-mAb—peptide complex might also play a role in the tumor retention of the radiolabel after tumor targeting.

Cross-linking of 2 cell-surface antigens via a mAb can induce acceleration of internalization of the antigen–mAb complex (28). In the pretargeting system, cross-linking of tumor antigens can occur via the bivalent peptide. Here we examined the influence of G250 antigen cross-linking on the internalization rate of the peptide.

MATERIALS AND METHODS

bs-mAb G250xDTIn-1

The characteristics of the mAb anti-G250 (IgG1), directed against the RCC-associated antigen G250, identified as carbonic anhydrase isoform IX (MN/CA IX), have been described by Oosterwijk et al. (29). The MN/CA IX antigen is expressed on the cell surface of virtually all clear-cell RCCs (30).

The characteristics of anti-DTPA-In mAb (DTIn-1, IgG2a), the isolation of bispecific antibody–producing quadroma cells, and the characterization and purification of the bs-mAb G250xDTIn-1 have been described in detail previously (31).

111In-G250xDTIn-1.

The bs-mAb G250xDTIn-1 was conjugated with ITC-DTPA (ITC is p-isothiocyanatobenzyl) according to Ruegg et al. (32). Briefly, to 100 μL bs-mAb (5 mg/mL 50 mmol/L Na2CO3, pH 9.5), 0.117 mg ITC-DTPA was added and, after 1-h incubation at room temperature, the reaction mixture was dialyzed against 50 mmol/L NaAc, pH 5.5, in a Slide-A-Lyzer (10-kDa cutoff; Pierce Chemical Co.) to eliminate the excess ITC-DTPA. bs-mAb—ITC-DTPA was labeled with 111In: To 155 μg bs-mAb—ITC-DTPA, 11.1 MBq (300 μCi) 111InCl3 (Tyco Health Care) were added and the reaction mixture was incubated for 1 h at room temperature. The radiochemical purity (RCP) was determined by instant thin-layer chromatography on silica gel strips using 0.15 mol/L citrate buffer (pH 6.0) as the mobile phase (RCP, >98%).

125I-G250xDTIn-1.

The bs-mAb was radioiodinated with 125I using the IODO-GEN-method (Pierce Chemical Co.) (33). To a 100-μg IODO-GEN vial, 140 μL bs-mAb (1.475 mg/mL), 20.4 MBq (550 μCi) Na125I, and 50 μL phosphate buffer, pH 7.4, were added. After incubating the reaction mixture at room temperature for 10 min, the iodinated bs-mAb was purified on a PD-10 column, eluted with 0.5% bovine serum albumin and phosphate-buffered saline.

Bivalent Peptide

l-a.a. Peptide.

The synthesis of the bivalent l-a.a. peptide (Ac-Phe-Lys(DTPA)-Tyr-Lys(DTPA)-NH2) was described previously (10,34).

d-a.a. Peptide.

The bivalent d-a.a. peptide Ac-d-Phe-d-Lys(DTPA)-d-Tyr-d-Lys(DTPA)-NH2 was manually synthesized by using standard solid-phase Fmoc/HBTU (2-[1H-benzotriazole-1-yl]-1,1,3,3-tetramethyluronium hexafluorophosphate) chemistry on a rink amide resin. The lysine residue was coupled with its C-terminus to an Argogel rink resin (Argonaut). Subsequently, d-tyrosine, d-lysine, and d-phenylalanine were conjugated. After deprotection of the N-terminal amino acid residue from the resin, the peptide was acetylated at the N-terminus by treatment with acetic acid anhydride/HOBt/DIPEA solution (HOBt is 1-hydroxybenzotriazole hydrate; DIPEA is diisopropylethylamine). The peptide was deprotected and cleaved from the resin using a trifluoroacetic acid (TFA)/H2O mixture. Next, monoactivated DTPA chelates (DTPA-(t-Bu)4) (35) were conjugated to the ε-amino group of both lysine residues, using benzotriazole-1-yl-oxy-tris(dimethylamino)phosphonium hexafluorophosphate (BOP) as a coupling reagent. The peptide was purified by preparative reverse-phase high-performance liquid chromatography (RP-HPLC) on a C-8 column (Adsorbosphere XL, Allech; 250 × 22 mm) using a H2O/MeCN/TFA buffer system. Fractions were collected and lyophilized. The product was characterized using matrix-assisted laser desorption/ionization–time-of-flight (MALDI-TOF) mass spectrometry and electrospray ionization (ESI) mass spectroscopy (MH+ = 1,376.96 g/mol) and analyzed by RP-HPLC.

111In Labeling of l-a.a. Peptide and d-a.a. Peptide.

To 15 μL of the peptide solution (11 ng/μL), 15 μL 50 mmol/L NH4Ac (pH 5.4) and 7.4 MBq (0.2 mCi) 111InCl3 (Tyco Health Care) were added. The reaction mixture was incubated for 60 min at room temperature. The RCP was determined by RP-HPLC on an Agilent 1100 series liquid chromatography system (Agilent Technologies) and a Zorbax Rx-C18 column (5 μm, 4.6 × 250 mm). The column was eluted with a flow rate of 1 mL/min with a gradient from 10 mmol/L NH4Ac, pH 7.4, to 100% acetonitrile within 15 min. Radioactivity was detected with an in-line Radiomatic A-500 series flow detector (Canberra-Packard). A 3-fold molar excess InCl3 was added when the RCP was >95%, to saturate the remaining DTPA chelates with stable In3+.

125I Labeling of l-a.a. Peptide and d-a.a. Peptide.

The peptides were iodinated with 125I according to the IODO-GEN method (33). To a vial coated with 100 μg IODO-GEN, 5 μL (10 μg/mL) peptide, 15 μL phosphate buffer, pH 7.2, and 11.1 MBq (300 μCi) 125I were added. After a 10-min incubation, the reaction mixture was transferred to a reaction vial containing 1/10 volume 1 mol/L NH4Ac, pH 5.4. Subsequently, a 3-fold molar excess of stable InCl3 was added and incubated for 30 min to saturate the DTPA chelates. The peptide was purified on an activated C-18 SepPak cartridge (Waters), washed with 0.1 mol/L NH4Ac, pH 7.4, and eluted with 100% MeOH. After evaporation of the MeOH, the peptide was dissolved in 50 mmol/L NH4Ac, pH 5.4, and the RCP of the sample was determined by RP-HPLC as described (34).

In Vivo Experiments

Female BALB/c nu/nu mice were injected subcutaneously with 200 μL SK-RC-52 cell suspension (2 × 106 cells per 200 μL). After 2–3 wk, when tumor sizes were 50–300 mm3, the biodistribution experiments were initiated. SK-RC-52 RCC was derived from a clear-cell RCC metastatic lesion in the mediastinum (36) and was obtained from the Memorial Sloan-Kettering Cancer Center.

Mice with subcutaneous SK-RC-52 tumors were pretargeted with 15 μg bs-mAb G250xDTIn-1. After 72 h, mice were injected intravenously with 6 ng 125I-/111In-labeled peptide (l-a.a. peptide or d-a.a. peptide). All reagents were injected intravenously via the tail vein (200 μL).

To investigate the effect of cross-linking MN/CA IX antigens by bs-mAb—diDTPA bridge formation on the internalization of the Ag—bs-mAb complex, tumors were pretargeted with 15 μg of directly labeled bs-mAb (bs-mAb—111In/bs-mAb—125I). At 24 and 96 h after injection, 2 groups of mice were killed by CO2 asphyxiation without administrating the bivalent l-a.a. peptide (Table 1). Seventy-two hours after injection of the radiolabeled bs-mAb, 2 groups of mice were injected intravenously with an In3+-labeled bivalent l-a.a. peptide; 24 and 72 h after injection of the unlabeled bivalent peptide, mice were killed. Blood was obtained by cardiac puncture. Tissues (tumor, muscle, lung, spleen, kidney, liver, and small intestine) were dissected and weighed and the radioactivity was measured in a γ-counter (Wallac Wizard 3″ 1480 automatic γ-counter). To allow calculation of the radioactive uptake in each organ as a fraction of the injected dose, an aliquot of the injection dose was counted simultaneously. Results were expressed as % ID/g. All groups consisted of 4 or 5 mice.

View this table:
  • View inline
  • View popup
TABLE 1

Design of Experiment To Determine Effect of Cross-Linking of MN/CA IX Antigens

Statistical Analysis

All mean values are given as mean ± SD. Statistical analysis was performed using the unpaired t test when 2 groups were analyzed, and the 1-way ANOVA was used when >2 groups were analyzed. The level of significance was set at P < 0.05.

RESULTS

Biodistribution Results of Radiolabeled Bivalent Peptides

The uptake and retention of the 125I-/111In-labeled d-a.a. peptide and l-a.a. peptide in SK-RC-52 tumors are depicted in Figure 1. The tumor uptake of the 111In-labeled l-a.a. peptide was relatively high after pretargeting of SK-RC-52 tumors with bs-mAb G250xDTIn-1 (Fig. 1B; maximum uptake, 22.0 ± 6.9 %ID/g at 4 h after injection). Although the 111In label is considered as a residualizing radionuclide, the radiolabel cleared from the tumor in time. The maximum uptake in the tumor of the 125I-iodinated l-a.a. bivalent peptide was significantly lower compared with that of the 111In-labeled l-a.a. peptide. In addition, the 125I label cleared from the tumor much more rapidly (Fig. 1A; 5.1 ± 0.8 %ID/g at 4 h after injection to 0.05 ± 0.01 %ID/g at 48 h after injection). In contrast, using the newly synthesized d-a.a. peptide, the uptake of the 125I radiolabel in the tumor was significantly higher and the radiolabel was retained in the tumor much better (Fig. 1A; 22.3 ± 5.3 %ID/g at 24 h after injection to 14.8 ± 5.0 %ID/g at 7 d after injection) than that of the iodinated l-a.a. peptide. The biodistribution of 111In and 125I, linked to the d-a.a. peptides, was highly similar. Moreover, the residence time of 125I-labeled d-a.a. peptide in the tumor was remarkably higher than that of the 111In-labeled l-a.a. peptide.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Uptake and retention of dual-labeled bivalent peptides in SK-RC-52 tumors. Tumor-bearing mice received 6 ng radiolabeled peptides, 72 h after pretargeting tumors with 15 μg bs-mAb G250xDTIn-1. (A) 125I-l-a.a. peptide (○) and 125I-d-a.a. peptide (•). (B) 111In-l-a.a. peptide (□) and 111In-d-a.a. peptide (▪). Biodistribution was determined 4, 24, 48, and 72 h after injection and 7 d after injection Uptake is expressed as %ID/g (mean ± SD).

The biodistribution data of the 111In-/125I-labeled d-a.a. peptide and l-a.a. peptides in pretargeted SK-RC-52 tumor-bearing mice are shown in Figure 2. The radioactivity was cleared relatively fast from the normal organs as well as from the circulation, regardless of the radiolabeled peptide used. This indicates no specific uptake of the radiolabeled peptides in the normal tissues (the hepatobiliary tract or renal excretion).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Biodistribution of radiolabeled bivalent peptides: 111In-l-a.a. peptide (A), 111In-d-a.a. peptide (B), 125I-l-a.a. peptide (C), and 125I-d-a.a. peptide (D). After pretargeting of SK-RC-52 tumor-bearing mice with 15 μg bs-mAb G250xDTIn-1, 72 h later mice were injected intravenously with 6 ng peptide. Mice were killed at various time points after injection of radiolabel and biodistribution was determined. Uptake is expressed as %ID/g (mean ± SD).

Effect of bs-mAb—diDTPA—bs-mAb Cross-Linking on Internalization

mAbs can induce or accelerate internalization of the antigen–mAb complex by cross-linking of the antigens. With our approach, using monovalently bound antigen—bs-mAb, dimerization of the antigens can be accomplished by bridge formation via a bivalent peptide. The influence of bridging 2 adjacent MN/CA IX antigens via a bivalent peptide on internalization of the Ag—bs-mAb complex was studied in vivo with 111In-/125I-labeled bs-mAb G250xDTIn-1 (Tables 1 and 2; Fig. 3). At 24 h after injection of the radiolabeled bs-mAb (no bivalent peptide administered), the 111In label showed a significantly higher uptake in the tumor than that of the 125I label (25.7 ± 9.4 %ID/g and 14.3 ± 2.1 %ID/g, respectively; P < 0.05). From 24 to 96 h after injection, the uptake of the 111In label in the tumor increased from 25.7 ± 9.4 %ID/g at 24 h after injection to 34.0 ± 10.3 %ID/g at 96 h after injection The uptake of the 125I label in the tumor decreased from 14.3 ± 2.1 %ID/g at 24 h after injection to 9.9 ± 2.2 %ID/g at 96 h after injection Administration of the unlabeled bivalent peptide (96 h after injection of the radiolabeled bs-mAb) did not lead to significant alterations in tumor targeting within 24 h (111In: 32.5 ± 10.8 %ID/g and 34.0 ± 10.3 %ID/g, respectively; 125I: 8.7 ± 2.3 %ID/g and 9.9 ± 2.2 %ID/g, respectively).

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Biodistribution of 111In label (A) and 125I label (B) in tumor-bearing mice, pretargeted with 15 μg 111In-/125I-labeled bs-mAb G250xDTIn-1. Seventy-two hours later, 2 groups of mice were injected intravenously with 6 ng bivalent peptide (groups 3 and 4, DTPA chelates loaded with unlabeled indium). Mice were killed at various time points after injection of radiolabel (Table 1) and biodistribution was determined. Uptake is expressed as %ID/g (mean ± SD).

View this table:
  • View inline
  • View popup
TABLE 2

Biodistribution Results of Pretargeting of SK-RC-52 RCC with 111In-/125I-Labeled bs-mAb G250xDTIn-1

DISCUSSION

Pretargeting RCC tumors with a bs-mAb directed against MN/CA IX antigen, in combination with 111In-labeled bivalent peptide, leads to excellent tumor targeting together with a very rapid and complete background clearance. For RIT, the 131I radiolabel is a commonly used radionuclide with suboptimal physiologic characteristics for the treatment of small tumor lesions. Unfortunately, after internalization and degradation of the radiolabeled peptide, the metabolite 131I-Tyr is rapidly excreted from the tumor cells. Enhanced tumor cell retention of the 131I label is required to achieve therapeutic efficacy. Therefore, a new bivalent peptide, more resistant to proteolytic degradation, was synthesized, consisting of 4 d-a.a. and substituted with 2 DTPA chelates.

In the SK-RC-52 RCC tumor model, the pretargeting strategy was tested by comparing the use of the iodinated bivalent d-a.a. peptide and the iodinated l-a.a. peptide.

Peptide-containing endosomes, appearing after internalization of the bound antigen, fuse with lysosomes. Peptides are degraded in the lysosomes by peptidases to single amino acids, and the majority of the amino acid residues are subsequently excreted from the cell. However, when the lysine residue is conjugated with 111In-labeled DTPA, the Lys-DTPA(111In) metabolite is trapped in the lysosomes. Foulon et al. ascribed the capturing of the Lys-DTPA(111In) in the lysosomes to the positively charged lysine-DTPA(In) complex at lysosomal pH (37), whereas Stein et al. (19,20) and Govindan et al. (21) reported that the enhanced hydrophilicity, caused by the present DTPA chelate, was responsible for trapping of the 111In-labeled lysine.

The newly synthesized d-a.a. peptide as well as the l-a.a. peptide were blocked on both termini to reduce the susceptibility to proteolytic degradation in the circulation, but lysosomal endopeptidases could still metabolize the l-a.a. peptide. When iodinated, the metabolite 125I-l-Tyr will rapidly be excreted from the cell. In contrast, the residence time of the radiolabel was significantly improved when the d-a.a. peptide was used. Presumably, in contrast to the l-a.a. peptides, the d-a.a. peptides remained intact in the lysosomes because the d-a.a. peptide bonds are more resistant to peptidase degradation. The iodinated tyrosine residue remained bound to both adjoining DTPA-substituted lysine residues, which cannot cross the lysosomal membrane. Accordingly, the nonresidualizing property of iodine was converted into a residualizing character.

The uptake of the residualizing radiolabeled peptide in the tumor increased or was stabilized from 4 to 24 h after injection (Fig. 1). The uptake of the residualizing 111In label in the tumor was significantly higher at 4 h after injection than the uptake of the nonresidualizing 125I label when labeled to the l-a.a. peptide. These results indicated a rapid internalization rate of the radiolabeled bivalent peptide. In addition, previously published data showed an increased uptake and an enhanced retention of the radiolabel in the tumor when the pretargeting strategy was performed with a bivalent 111In-labeled peptide instead of a monovalent hapten (23–25). It has been shown that cross-linking of the cell-surface-antigen by antibodies could induce accelerated internalization (28). Therefore, we hypothesized that bridging 2 MN/CA IX antigens via a bivalent peptide might be necessary to influence internalization. The improved tumor targeting using a bivalent peptide instead of a monovalent hapten could be due to bridge formation of the MN/CA XI antigen by a bivalent peptide to induce internalization, which is not feasible with a monovalent hapten. This cross-bridge formation was previously designated the “affinity enhancement system,” as described by Devys et al. (26) and Barbet et al. (27).

The effect of cross-linking 2 MN/CA IX antigens was examined with pretargeting of directly labeled bs-mAb (111In—bs-mAb and 125I—bs-mAb) exploiting the residualizing character differences between both radiolabels. The pretargeted tumors were targeted with or without a bivalent peptide loaded with unlabeled indium. By 24 h after injection of the labeled bs-mAb, a significant difference in uptake of both radiolabels was observed, suggesting that internalization occurred with monovalently bound bs-mAb. Second, no significant difference in uptake of the individual radiolabels in the tumor was observed between groups 2 and 3, indicating that cross-bridge formation did not affect the internalization rate. In addition, even up to 72 h after the injection of the bivalent peptide (group 4), the uptake of the radiolabel in the tumor did not change significantly. Cross-bridge formation does not affect the internalization rate in this tumor model, which displays the significance of an accurate determination of the optimal protein and peptide dose and the optimal interval between both administrations.

In summary, a significant improvement in the uptake and retention of radioiodine in the tumor can be achieved in the pretargeting strategy with iodinated d-a.a. peptides instead of l-a.a. peptides. Internalization of the antigen—bs-mAb complex was not induced or enhanced by bridge formation of the MN/CA IX antigens.

CONCLUSION

With the pretargeting strategy, the uptake and retention of the radiolabel in tumors are improved when radiolabeled d-a.a. peptides were used for both indium and iodine.

Acknowledgments

This work was supported by a research grant from the Dutch Cancer Society (KUN 2000-2306). We thank Gerry Grutters, Hennie Eijkholt, and Bianca de Weem (University of Nijmegen, Central Animal Laboratory) for technical assistance in the animal experiments.

Footnotes

  • Received Dec. 1, 2004; revision accepted Jan. 14, 2005.

    For correspondence or reprints contact: Frank G. van Schaijk, PhD, Department of Nuclear Medicine, University Medical Center Nijmegen, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands.

    E-mail: F.vanSchaijk{at}nucmed.umcn.nl

REFERENCES

  1. ↵
    Goldenberg DM. Targeted therapy of cancer with radiolabeled antibodies. J Nucl Med. 2002;43:693–713.
    OpenUrlAbstract/FREE Full Text
  2. Mach JP, Pelegrin A, Buchegger F. Imaging and therapy with monoclonal antibodies in non-hematopoietic tumors. Curr Opin Immunol. 1991;3:685–693.
    OpenUrlCrossRefPubMed
  3. ↵
    Chang CH, Sharkey RM, Rossi EA, et al. Molecular advances in pretargeting radioimmunotherapy with bispecific antibodies. Mol Cancer Ther. 2002;1:553–563.
    OpenUrlAbstract/FREE Full Text
  4. ↵
    Goldenberg DM. The role of radiolabeled antibodies in the treatment of non-Hodgkin’s lymphoma: the coming of age of radioimmunotherapy. Crit Rev Oncol Hematol. 2001;39:195–201.
    OpenUrlPubMed
  5. ↵
    Postema EJ, Raemaekers JM, Oyen WJ, et al. Final results of a phase I radioimmunotherapy trial using 186Re-epratuzumab for treatment of patients with non-Hodgkin’s lymphoma. Clin Cancer Res. 2003;9(suppl):3995s–4002s.
  6. ↵
    Bruland OS. Cancer therapy with radiolabeled antibodies: an overview. Acta Oncol. 1995;34:1085–1094.
    OpenUrlPubMed
  7. ↵
    Goldenberg DM. Advancing role of radiolabeled antibodies in the therapy of cancer. Cancer Immunol Immunother. 2003;52:281–296.
    OpenUrlPubMed
  8. ↵
    Goodwin DA, Meares CF, McCall MJ, McTigue M, Chaovapong W. Pre-targeted immunoscintigraphy of murine tumors with indium-111-labeled bifunctional haptens. J Nucl Med. 1988;29:226–234.
    OpenUrlAbstract/FREE Full Text
  9. ↵
    Goodwin DA, Meares CF, McTigue M, David GS. Monoclonal antibody hapten radiopharmaceutical delivery. Nucl Med Commun. 1986;7:569–580.
    OpenUrlPubMed
  10. ↵
    Boerman OC, Kranenborg MH, Oosterwijk E, et al. Pretargeting of renal cell carcinoma: improved tumor targeting with a bivalent chelate. Cancer Res. 1999;59:4400–4405.
    OpenUrlAbstract/FREE Full Text
  11. ↵
    van Schaijk FG, Oosterwijk E, Molkenboer-Kuenen J, et al. Pretargeting with bispecific anti-renal cell cancer x anti-DTPA(In) antibody in three RCC models. J Nucl Med. 2005;46:495–501.
    OpenUrlAbstract/FREE Full Text
  12. ↵
    Kairemo KJ. Radioimmunotherapy of solid cancers: a review. Acta Oncol. 1996;35:343–355.
    OpenUrlPubMed
  13. Macey DJ, Meredith RF. A strategy to reduce red marrow dose for intraperitoneal radioimmunotherapy. Clin Cancer Res. 1999;5(suppl):3044s–3047s.
  14. Gautherot E, Kraeber-Bodere F, Daniel L, et al. Immunohistology of carcinoembryonic antigen (CEA)-expressing tumors grafted in nude mice after radioimmunotherapy with 131I-labeled bivalent hapten and anti-CEA x antihapten bispecific antibody. Clin Cancer Res. 1999;5(suppl):3177s–3182s.
  15. ↵
    Gautherot E, Rouvier E, Daniel L, et al. Pretargeted radioimmunotherapy of human colorectal xenografts with bispecific antibody and 131I-labeled bivalent hapten. J Nucl Med. 2000;41:480–487.
    OpenUrlAbstract/FREE Full Text
  16. ↵
    Duncan JR, Welch MJ. Intracellular metabolism of indium-111-DTPA-labeled receptor targeted proteins. J Nucl Med. 1993;34:1728–1738.
    OpenUrlAbstract/FREE Full Text
  17. ↵
    Holtzman E. Lysosomes. New York, NY: Plenum Press; 1989:95–100.
  18. ↵
    Duncan JR, Stephenson MT, Wu HP, Anderson CJ. Indium-111-diethylenetriaminepentaacetic acid-octreotide is delivered in vivo to pancreatic, tumor cell, renal, hepatocyte lysosomes. Cancer Res. 1997;57:659–671.
    OpenUrlAbstract/FREE Full Text
  19. ↵
    Stein R, Goldenberg DM, Thorpe SR, Basu A, Mattes MJ. Effects of radiolabeling monoclonal antibodies with residualizing iodine radiolabeled on the accretion of radioisotope in tumors. Cancer Res. 1995;55:3132–3139.
    OpenUrlAbstract/FREE Full Text
  20. ↵
    Stein R, Govindan SV, Mattes MJ, et al. Improved iodine radiolabels for monoclonal antibody therapy. Cancer Res. 2003;63:111–118.
    OpenUrlAbstract/FREE Full Text
  21. ↵
    Govindan SV, Mattes MJ, Stein R, et al. Labeling of monoclonal antibodies with diethylenetriaminepentaacetic acid-appended radioiodinated peptides containing D-amino acids. Bioconjug Chem. 1999;10:231–240.
    OpenUrlCrossRefPubMed
  22. ↵
    Milton RC, Milton SC, Kent SB. Total chemical synthesis of a D-enzyme: the enantiomers of HIV-1 protease show reciprocal chiral substrate specificity [correction]. Science. 1992;256:1445–1448.
    OpenUrlAbstract/FREE Full Text
  23. ↵
    Boerman OC, Van Schaijk FG, Oyen WJ, Corstens FH. Pretargeted radioimmunotherapy of cancer: progress step-by-step. J Nucl Med. 2003;44:400–411.
    OpenUrlAbstract/FREE Full Text
  24. Goodwin DA, Meares CF, Watanabe N, et al. Pharmacokinetics of pretargeted monoclonal antibody 2D12.5 and 88Y-Janus-2-(p-nitrobenzyl)-1,4,7,10-tetraazacyclododecanetetraacetic acid (DOTA) in BALB/c mice with KHJJ mouse adenocarcinoma: a model for 90Y radioimmunotherapy. Cancer Res. 1994;54:5937–5946.
    OpenUrlAbstract/FREE Full Text
  25. ↵
    Le Doussal JM, Gruaz-Guyon A, Martin M, Gautherot E, DeLaage M, Barbet J. Targeting of indium 111-labeled bivalent hapten to human melanoma mediated by bispecific monoclonal antibody conjugates: imaging of tumors hosted in nude mice. Cancer Res. 1990;50:3445–3452.
    OpenUrlAbstract/FREE Full Text
  26. ↵
    Devys A, Thedrez P, Gautherot E, et al. Comparative targeting of human colon-carcinoma multicell spheroids using one- and two-step (bispecific antibody) techniques. Int J Cancer. 1996;67:883–891.
    OpenUrlPubMed
  27. ↵
    Barbet J, Kraeber-Bodere F, Vuillez JP, Gautherot E, Rouvier E, Chatal JF. Pretargeting with the affinity enhancement system for radioimmunotherapy. Cancer Biother Radiopharm. 1999;14:153–166.
    OpenUrlCrossRefPubMed
  28. ↵
    McQuarrie SA, Xiao Z, Miller GG, Mercer JR, Suresh MR. Modern trends in radioimmunotherapy of cancer: pretargeting strategies for the treatment of ovarium cancer. Q J Nucl Med. 2001;45:160–166.
    OpenUrlPubMed
  29. ↵
    Oosterwijk E, Ruiter DJ, Hoedemaeker PJ, et al. Monoclonal antibody G 250 recognizes a determinant present in renal cell carcinoma and absent from normal kidneys. Int J Cancer. 1986;38:489–494.
    OpenUrlCrossRefPubMed
  30. ↵
    Uemura H, Nakagawa Y, Yoshida K, et al. MN/CA IX/G250 as a potential target for immunotherapy of renal cell carcinomas. Br J Cancer. 1999;81:741–746.
    OpenUrlCrossRefPubMed
  31. ↵
    Kranenborg MH, Boerman OC, Oosterwijk-Wakka JC, De Weijert MC, Corstens FH, Oosterwijk E. Development and characterization of anti-renal cell carcinoma x antichelate bispecific monoclonal antibodies for two-phase targeting of renal cell carcinoma. Cancer Res. 1995;55(suppl):5864s–5867s.
    OpenUrlAbstract/FREE Full Text
  32. ↵
    Ruegg CL, Anderson-Berg WT, Brechbiel MW, Mirzadeh S, Gansow OA, Strand M. Improved in vivo stability and tumor targeting of bismuth-labeled antibody. Cancer Res. 1990;50:4221–4226.
    OpenUrlAbstract/FREE Full Text
  33. ↵
    Fraker PJ, Speck JC Jr. Protein and cell membrane iodinations with a sparingly soluble chloroamide, 1,3,4,6-tetrachloro-3a,6a-diphrenylglycoluril. Biochem Biophys Res Commun. 1987;80:849–857.
  34. ↵
    van Schaijk FG, Oosterwijk E, Soede AC, et al. Pretargeting with labeled bivalent peptides allowing the use of four radionuclides: 111In, 131I, 99mTc, and 188Re. Clin Cancer Res. 2003;9(suppl):3880s–3885s.
  35. ↵
    Arano Y, Uezono T, Akizawa H, et al. Reassessment of diethylenetriaminepentaacetic acid (DTPA) as a chelating agent for indium-111 labeling of polypeptides using a newly synthesized monoreactive DTPA derivative. J Med Chem. 1996;39:3451–3460.
    OpenUrlCrossRefPubMed
  36. ↵
    Ebert T, Bander NH, Finstad CL, Ramsawak RD, Old LJ. Establishment and characterization of human renal cancer and normal kidney cell lines. Cancer Res. 1990;50:5531–5536.
    OpenUrlAbstract/FREE Full Text
  37. ↵
    Foulon CF, Reist CJ, Bigner DD, Zalutsky MR. Radioiodination via D-amino acid peptide enhances cellular retention and tumor xenograft targeting of an internalizing anti-epidermal growth factor receptor variant III monoclonal antibody. Cancer Res. 2000;60:4453–4460.
    OpenUrlAbstract/FREE Full Text
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 46 (6)
Journal of Nuclear Medicine
Vol. 46, Issue 6
June 1, 2005
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Residualizing Iodine Markedly Improved Tumor Targeting Using Bispecific Antibody-Based Pretargeting
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Residualizing Iodine Markedly Improved Tumor Targeting Using Bispecific Antibody-Based Pretargeting
Frank G. van Schaijk, Matthias Broekema, Egbert Oosterwijk, Juliette E.M. van Eerd, Bill J. McBride, David M. Goldenberg, Frans H.M. Corstens, Otto C. Boerman
Journal of Nuclear Medicine Jun 2005, 46 (6) 1016-1022;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Residualizing Iodine Markedly Improved Tumor Targeting Using Bispecific Antibody-Based Pretargeting
Frank G. van Schaijk, Matthias Broekema, Egbert Oosterwijk, Juliette E.M. van Eerd, Bill J. McBride, David M. Goldenberg, Frans H.M. Corstens, Otto C. Boerman
Journal of Nuclear Medicine Jun 2005, 46 (6) 1016-1022;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • THIS MONTH IN JNM
  • PubMed
  • Google Scholar

Cited By...

  • Pretargeting: A Path Forward for Radioimmunotherapy
  • Theranostics Using Antibodies and Antibody-Related Therapeutics
  • Assessing Antibody Pharmacokinetics in Mice with In Vivo Imaging
  • Successful Radiotherapy of Tumor in Pretargeted Mice by 188Re-Radiolabeled Phosphorodiamidate Morpholino Oligomer, a Synthetic DNA Analogue.
  • Pretargeting of Carcinoembryonic Antigen-Expressing Tumors with a Biologically Produced Bispecific Anticarcinoembryonic Antigen x Anti-Indium-Labeled Diethylenetriaminepentaacetic Acid Antibody
  • Google Scholar

More in this TOC Section

  • 11C-Methionine PET of Myocardial Inflammation in a Rat Model of Experimental Autoimmune Myocarditis