JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mullani, N. A.
Right arrow Articles by Mawlawi, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mullani, N. A.
Right arrow Articles by Mawlawi, O.
Journal of Nuclear Medicine Vol. 46 No. 5 898
© 2005 by Society of Nuclear Medicine

Why Is the Resolution of the Discovery PET/CT Camera So Poor?

Nizar A. Mullani, BSc

University of Texas-Houston Medical School
Sugar Land, Texas

TO THE EDITOR:

Mawlawi et al. (1) present an excellent study documenting the performance of the new Discovery PET/CT camera (General Electric Medical Systems). However, as a designer of PET cameras, I am perplexed as to why the resolution of this new camera is so poor.

The Discovery PET camera uses design concepts similar to those pioneered by Mullani et al. in 1984 for the Posicam PET camera (Positron Corp.) (2) but, to increase its sensitivity, has a smaller detector ring diameter and shorter septa and uses more of the cross-coincidences between adjacent slices. The detector size in the Discovery, at 6.3 mm, is significantly smaller than the 8.5-mm detector in the Posicam. Therefore, the resolution should be better for the Discovery than for the Posicam. However, the resolution of the Discovery, at 6.09 mm in full width at half maximum, is slightly lower than the published resolution (5.8 mm in full width at half maximum) of the Posicam.

Perhaps the authors or the designers of the Discovery PET camera would like to explain to the readers why the resolution of their camera is lower than for a similar camera using larger crystals.

REFERENCES

  1. Mawlawi O, Podoloff DA, Kohlmyer S, et al. Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes. J Nucl Med. 2004;45:1734–1742.[Abstract/Free Full Text]
  2. Mullani NA, Gould KL, Hartz RK, et al. Design and performance of POSICAM 6.5 BGO positron camera. J Nucl Med. 1990;31:610–616.[Abstract/Free Full Text]

 
Osama Mawlawi, PhD

M.D. Anderson Cancer Center
Houston, Texas

REPLY:

My coauthors and I appreciate the observation of Dr. Mullani regarding the measured resolution of the Discovery ST PET/CT scanner (General Electric Medical Systems) that was presented in our article (1).

The resolution of a PET scanner depends on several factors, including the detector element size and ring diameter. It has also been shown that detector decoding, such as that used in block detector designs, can affect the system resolution (2). For scanners that are designed with 1 detector per photomultiplier tube, the scanner resolution is approximately half the detector size. On the other hand, scanners with a block detector design have resolutions that are roughly equal to the individual crystal size in the block (1). In this regard, stationary ring cameras such as the Discovery ST, which has a block detector design, will have a transaxial image resolution similar to its detector size of 6.3 mm. Transaxial resolution measurements have been published for several scanners from several different manufacturers (1,38), including the Discovery ST measurements that were recently published in The Journal of Nuclear Medicine (1). Each of these scanners uses block detectors, except for the Allegro (Philips Medical Systems), which uses a modular detector design with many properties of a block detector. In each case the resolution is approximately equal to the crystal size.

PET systems using different detector designs, such as that in the Posicam 6.5 (Positron Corp.) (9), may achieve resolution results different from those achieved by a block detector with a comparable detector size. Nonetheless, the resolution of the Discovery ST is not "poor" but is consistent with the expected results for its type of detector design.

REFERENCES

  1. Mawlawi O, Podoloff DA, Kohlmyer S, et al. Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes. J Nucl Med. 2004;45:1734–1742.
  2. Moses WW, Derenzo SE, Empirical observation of resolution degradation in poistron emission tomographs utilizing block detectors [abstract]. J Nucl Med. 1993;34(suppl).:101P.
  3. Holte S, Eriksson L, Larsson JE, et al. A preliminary evaluation of a positron camera system using weighted decoding of individual crystals. IEEE Trans Nucl Sci. 1988;35:730–734.
  4. Wienhard K, Eriksson L, Grootoonk S, Casey M, Pietrzyk U, Heiss W-D. Performance evaluation of the positron scanner ECAT EXACT. J Comput Assist Tomogr. 1992;16:804–813.[Medline]
  5. Degrado TR, Turkington TG, Williams JJ, Stearns CW, Hoffman JM, Coleman RE. Performance characteristics of a whole-body PET scanner. J Nucl Med. 1994;35:1398–1406.[Abstract/Free Full Text]
  6. Wienhard K, Dahlbom M, Eriksson L, et al. The ECAT EXACT HR: performance of a new high-resolution positron scanner. J Comput Assist Tomogr. 1994;18:110–118.[Medline]
  7. Brix G, Zaers J, Adam LE, et al. Performance evaluation of a whole-body PET scanner using the NEMA protocol. J Nucl Med. 1997;38:1614–1623.[Abstract/Free Full Text]
  8. Surti S, Karp JS. Imaging characteristics of a 3-dimensional GSO whole body PET camera. J Nucl Med. 2004;45:1040–1049.[Abstract/Free Full Text]
  9. Mullani NA, Gould KL, Hartz RK, et al. Design and performance of POSICAM 6.5 BGO positron camera. J Nucl Med. 1990;31:610–616.



This article has been cited by other articles:


Home page
J. Nucl. Med. Technol.Home page
R. L. Bridges, C. R. Wiley, J. C. Christian, and A. P. Strohm
An Introduction to Na18F Bone Scintigraphy: Basic Principles, Advanced Imaging Concepts, and Case Examples
J. Nucl. Med. Technol., June 1, 2007; 35(2): 64 - 76.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mullani, N. A.
Right arrow Articles by Mawlawi, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mullani, N. A.
Right arrow Articles by Mawlawi, O.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE