Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherLetters to the Editor

Scintimammography with a Pinhole Collimator

Siroos Mirzaei and Peter Knoll
Journal of Nuclear Medicine March 2005, 46 (3) 550-551;
Siroos Mirzaei
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Peter Knoll
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

TO THE EDITOR:

We read with great interest the paper by Coover et al. (1) regarding scintimammography using a dedicated breast camera. The results seem to be fascinating. In line with the authors, we agree that efforts to improve the imaging technique may lead to a higher sensitivity for scintimammography, particularly in the selected patient group of women with dense breast tissue. Preliminary experience obtained in other studies (2,3) has shown that use of a pinhole collimator might also improve visualization of breast lesions examined by scintimammography. Just for localization of the tumor, we would prefer the use of a γ-probe (4) for patient convenience instead of the scintimammographic needle localization described by the authors (1).

REFERENCES

  1. ↵
    Coover LR, Caravaglia G, Kuhn P. Scintimammography with dedicated breast camera detects and localizes occult carcinoma. J Nucl Med. 2004;45:553–558.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    Koukouraki S, Damilakis J, Giatromanolaki A, Androulakis E, Karkavitsas N, Koukourakis M. Functional imaging of tumors with 99Tcm-sestamibi pinhole scintigraphy. Nucl Med Commun. 1996;17:943–951.
    OpenUrlPubMed
  3. ↵
    Tornai MP, Bowsher JE, Jaszczak RJ, et al. Mammotomography with pinhole incomplete circular orbit SPECT. J Nucl Med. 2003;44:583–593.
    OpenUrlAbstract/FREE Full Text
  4. ↵
    Barbera L, Illanes L, Terrier F, Dopta G. Occult breast cancer: detection and radioguided surgery with 99mTc-MIBI. Rev Esp Med Nucl.2003;22:6–12.
    OpenUrlPubMed

REPLY:

Koukouraki et al. (2) described 25 patients with known malignancies who underwent 99mTc-sestamibi (Cardiolite; Dupont) scintimammography using parallel and pinhole collimation in assessing response to radiation therapy. The investigators concluded that tumor avidity for sestamibi could successfully be assessed with pinhole scintimammography.

Tornai et al. (3) used pinhole apertures with small but very high stopping power to evaluate dedicated mammotomography with pinhole incomplete circular orbit (PICO) SPECT of 1 breast that was uncompressed and pendant. This 1 breast had 2 lesions. They compared this method to planar pinhole scintimammography. They concluded that both lesions of the 1 breast were better visualized with PICO SPECT than with planar pinhole imaging.

Barbera et al. (4) performed planar scintimammography and SPECT with 99mTc-sestamibi on patients presenting with axillary lymphadenopathy. Positive findings led to use of a γ-detecting probe to locate the lesion and guide its surgical removal. Five cases were described.

In reference to our study, comparison and comment are not possible because of the different detection techniques and different patient selection criteria. Our study population was quite different from the populations of each of these 3 studies. Our technique was used for screening a population of women with mammographically dense breasts, category 1 or 2 mammography findings, unremarkable clinical examinations, and a strong family history of breast cancer.

The lesions detected in our screening population were small, and only 1 of the 3 was detected using planar imaging with the standard camera. Considering the relatively low target-to-background ratio of the 3 lesions detected in our study, further studies evaluating γ-probe detection of these types of lesions may be warranted.

REFERENCES

  1. 2.↵
    Koukouraki S, Damilakis J, Giatromanolaki A, Androulakis E, Karkavitsas N, Koukourakis M. Functional imaging of tumors with 99Tcm-sestamibi pinhole scintigraphy. Nucl Med Commun. 1996;17:943–951.
  2. 3.↵
    Tornai MP, Bowsher JE, Jaszczak RJ, et al. Mammotomography with pinhole incomplete circular orbit SPECT. J Nucl Med. 2003;44:583–593.
  3. 4.↵
    Barbera L, Illanes L, Terrier F, Dopta G. Occult breast cancer: detection and radioguided surgery with 99mTc-MIBI. Rev Esp Med Nucl. 2003;22:6–12.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 46 (3)
Journal of Nuclear Medicine
Vol. 46, Issue 3
March 1, 2005
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Scintimammography with a Pinhole Collimator
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Scintimammography with a Pinhole Collimator
Siroos Mirzaei, Peter Knoll
Journal of Nuclear Medicine Mar 2005, 46 (3) 550-551;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Scintimammography with a Pinhole Collimator
Siroos Mirzaei, Peter Knoll
Journal of Nuclear Medicine Mar 2005, 46 (3) 550-551;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • REFERENCES
    • REFERENCES
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • 176Lu Radiation in Long–Axial-Field-of-View PET Scanners: A Nonissue for Patient Safety
  • Business Model Beats Science and Logic: Dosimetry and Paucity of Its Use
  • Reply to “Routine Dosimetry: Proceed with Caution”
Show more Authors of the Letter and the Reply

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire