Click on image to view larger version.



FIGURE 3. When 15O-water washout images are superimposed on extravascular images and analyzed with semiautomated edge-detection routine, a whole myocardial ROI is determined. Program extracts 3D region enclosing the whole myocardial wall; process is performed in the 3D matrices. Positioning of whole LV wall ROI on 15O-water washout images is evident. (A) Circles are placed semiautomatically inside and outside myocardial edges. (B) Program defines endocardial and epicardial borders of LV wall (B).





Right arrow Return to article


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS