Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherLetters to the Editor

Whole-Body Thyroid Tumor 123I Scintigraphy

Stephen K. Gerard
Journal of Nuclear Medicine May 2003, 44 (5) 852;
Stephen K. Gerard
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

TO THE EDITOR:

We appreciate the favorable report of Shankar et al. on the use of 24-h 123I scintigraphy for whole-body thyroid tumor imaging (1). We concurrently reported our study on the use of 123I thyroid tumor imaging (2), in which we compared whole-body acquisitions 6, 24, and 48 h after 123I doses of 111–185 MBq (3–5 mCi). We agree with the investigators that, versus the 6-h imaging time, the 24-h imaging time improves detection of less avid sites of differentiated thyroid tissue. However, we disagree with the authors’ assertion that even larger 123I doses and a later imaging time, that is, 48 h, do not further improve sensitivity. Our experience showed that, in conjunction with our higher-dosage scheme, 48-h images yielded a higher target-to-background activity at sites of differentiated thyroid tissue, either tumor or remnant, than did images obtained at 24 or 6 h. In 1 patient, shown in our Figure 2, 48-h images alone demonstrated the site of thyroid metastasis, which was subsequently confirmed on the post-131I therapy scan. (The specificity of this finding on the 48-h diagnostic scan was further confirmed by a significant post-131I therapy decrease in the patient’s thyroglobulin level.)

The authors cited a study by Berbano et al. (reference 9 in their article) in which no advantage over 24-h 123I imaging was claimed for 48-h 123I imaging (3). Unfortunately, target-to-background ratio, known to have affected diagnostic sensitivity in all other diagnostic imaging experience with 131I, was neither qualitatively nor quantitatively evaluated in this study. A single 48-h whole-body image was shown (Fig. 6), with a caption stating that the image shows “… less defined areas of uptake in comparison with 24-h image [shown in the adjacent figure].” Both the 24-h and the 48-h images for this patient show only a prominent thyroid remnant, with a better-quality image at the earlier time, as expected because of the higher counts. However, another figure in this article (Fig. 3) shows a patient for whom the post-131I therapy scan showed multiple additional tumor foci, compared with the 24-h 123I diagnostic scan, without reference to the 48-h 123I scan. It is curious that the authors chose, as their sole example of a 48-h 123I scan, one showing only a prominent remnant in the thyroid bed (typically least likely to benefit from late imaging in our experience), as opposed to a 48-h 123I scan from a patient for whom the post-131I therapy scan showed multiple tumor foci that were not seen in companion 24-h 123I images.

Both larger diagnostic doses of 131I and the use of later post-131I therapy imaging times are known to positively affect the sensitivity of diagnostic imaging (4,5). Therefore, it would stand to reason that these same technical variables would similarly augment the sensitivity of 123I diagnostic scanning, particularly for residual or metastatic thyroid tumor, which is often less radioiodine avid than is thyroid remnant. Our own experience supports this supposition (2).

The value of routine diagnostic radioiodine scanning before 131I radioiodine ablative therapy remains controversial. However, we continue to believe in the importance of defining the full extent of thyroid remnant and tumor before 131I therapy, since this diagnostic assessment affects determination of the 131I therapeutic dose. Toward that end, we agree with the authors that diagnostic scanning with 123I, rather than with 131I, affords the advantages of improved image quality and absence of any significant potential for stunning. However, our experience with 123I (2) and extrapolation from prior experience with 131I (4,5) both support the suggestion that using larger doses of 123I and a later, 48-h, imaging time should improve diagnostic sensitivity.

We also note the following technical criticisms. First, the 123I and post-131I therapy diagnostic images in the authors’ Figure 3 appear notably suboptimal, with a superimposed phototube artifact of a Swiss-cheese pattern. This artifact is typical of imprecise uniformity correction, which will compromise diagnostic sensitivity, particularly at later imaging times because of the proportionately greater error with lower count rates. Second, we take issue with the investigators’ use of medium-energy collimation for post-131I therapy imaging. High-energy collimation is more appropriate for the 364-keV 131I γ-photon. The alternative use of medium-energy collimators will result in greater septal penetration and poorer-resolution images. In a perhaps-related observation, we note that of the multiple pulmonary or hepatic thyroid tumor foci seen in the posterior view of the 24-h 123I whole-body image in the authors’ Figure 3, some are poorly visualized or questionably apparent in the companion 7-d post-131I therapy posterior image in the same figure. In particular, these include the superiormost focus in the right lung, which is equivocal in the 131I image, and the medial inferiormost focus also on the right, which is absent in the 131I image. This difference may be at least in part related to suboptimal collimation of the high-energy 131I photon. This limitation could have artifactually decreased the number of tumor foci identified in the post-131I therapy scans, thereby potentially masking some false-negative results on 24-h 123I diagnostic images.

REFERENCES

  1. ↵
    Shankar LK, Yamamoto AJ, Alavi A, Mandel SJ. Comparison of 123I scintigraphy at 5 and 24 hours in patients with differentiated thyroid cancer. J Nucl Med. 2002;43:72–76.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    Gerard SK, Cavalieri RR. I-123 diagnostic thyroid tumor whole-body scanning with imaging at 6, 24, and 48 hours. Clin Nucl Med. 2002;27:1–8.
    OpenUrlCrossRefPubMed
  3. ↵
    Berbano R, Naddaf S, Echemendia E, et al. Use of iodine-123 as a diagnostic tracer for neck and whole-body scanning in patients with well-differentiated thyroid cancer. Endocr Pract. 1998;4:11–16.
    OpenUrlPubMed
  4. ↵
    Waxman A, Ramanna L, Chapman N, et al. The significance of I-131 scan dose in patients with thyroid cancer: determination of the ablation: concise communication. J Nucl Med. 1981;22:861–865.
    OpenUrlAbstract/FREE Full Text
  5. ↵
    Coakley AJ, Page CJ, Croft D. Scanning dose and detection of thyroid metastases. J Nucl Med. 1980;21:803–804.
    OpenUrlFREE Full Text
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 44, Issue 5
May 1, 2003
  • Table of Contents
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Whole-Body Thyroid Tumor 123I Scintigraphy
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Whole-Body Thyroid Tumor 123I Scintigraphy
Stephen K. Gerard
Journal of Nuclear Medicine May 2003, 44 (5) 852;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Whole-Body Thyroid Tumor 123I Scintigraphy
Stephen K. Gerard
Journal of Nuclear Medicine May 2003, 44 (5) 852;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • REFERENCES
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Routine Dosimetry: Proceed with Caution
  • 176Lu Radiation in Long–Axial-Field-of-View PET Scanners: A Nonissue for Patient Safety
  • Business Model Beats Science and Logic: Dosimetry and Paucity of Its Use
Show more Letters to the Editor

Similar Articles

SNMMI

© 2025 SNMMI