Key Words: colorectal cancer cancer recurrence coincidence 18F-FDG
| INTRODUCTION |
|---|
|
|
|---|
CT has been the conventional imaging modality for identifying and localizing metastatic disease. Its sensitivity in this clinical setting, however, varies between 29% and 100% (average, 71%) according to different studies, with hepatic and lymph node metastases being the most frequently missed tumor sites (710).
Functional imaging is rapidly developing as a whole-body method to detect metastases. The most widely cited is 18F-FDG PET, the sensitivity of which ranges between 82% and 100% for the detection of extraluminal CRC (6,9,1116). The number of available dedicated PET scanners, however, is still limited, and PET is therefore inaccessible to a large number of patients. Multihead conventional gamma cameras that are used in the routine practice of nuclear medicine have been modified recently to use in the coincidence mode for the detection of positron emitters, enhancing the potential for imaging a greater number of patients with FDG (17,18). Several studies have been reported on the use of coincidence imaging of FDG for the detection of various malignancies, including lymphoma, head and neck tumors, breast cancer, pulmonary lesions, renal malignancies, and others (1921).
In this study, we report our experience with dual-head camera 18F-FDG coincidence imaging (DHC 18F-FDG) in the evaluation of patients with suspected recurrent or metastatic CRC.
| MATERIALS AND METHODS |
|---|
|
|
|---|
Indications for DHC 18F-FDG were as follows: (a) elevated carcinoembryonic antigen (CEA) levels and negative CT or colonoscopy findings (n = 18 studies); (b) the need to evaluate the extent of disease before surgical removal of a local recurrence (n = 17 studies) or of metastases (n = 35 studies); and (c) the need to differentiate between residual tumor and fibrosis in pelvic masses remaining after treatment (n = 3 studies).
We reviewed the medical records of all study patients, which included the clinical data, laboratory results, and reports of CT and colonoscopy performed within 8 wk of the 18F-FDG study. CT result reports (not films) were available for correlation for 61 of the 67 18F-FDG studies. Outpatients brought CT films for correlation at the time of the 18F-FDG study. The CT report was kept in the patients records, as were changes made in the original CT report when read concomitantly with the 18F-FDG.
Six studies on 5 patients were excluded from the analysis of results because of a follow-up of <6 mo for 3 normal studies and because the final diagnosis could not be assessed for 3 additional studies. The final study data were thus retrieved from 67 studies on 62 patients (28 women, 34 men; age range, 3285 y; mean age, 62 ± 13 y).
Surgery was performed within 1 mo after the 18F-FDG study on 37 patients: 11 patients referred because of elevated CEA levels (indication a), 24 patients referred for evaluation of the extent of the disease (indication b), and 2 patients referred for differential diagnosis between viable tumor and fibrosis (indication c).
18F-FDG Imaging
The patients fasted for at least 4 h before administration of 18F-FDG. Bladder catheterization was performed to minimize interference from urinary bladder activity. In the last 23 patients to be assessed, 20 mg furosemide (Lasix; Hoechst-Roussel Pharmaceuticals, Somerville, NJ) were administered intravenously to eliminate uptake in the renal collecting system.
On the basis of the patients weight, 370592 MBq (1016 mCi) 18F-FDG were injected intravenously. Imaging started 60150 min after injection. The timing of imaging was determined by measurements of the ratio between detected and processed photons. The chest, abdomen, and pelvis were imaged in 2 or 3 steps. If bowel activity and tumor sites needed to be differentiated, acquisition was repeated after changing the patients positioning.
Dual-Head Coincidence Technique.
DHC 18F-FDG studies were performed using a dual-head gamma camera with coincidence imaging capacity (Millenium VG; General Electric Medical Systems, Milwaukee, WI). The system is equipped with two 1.6-cm-thick, large-area (54 x 40 cm) NaI(Tl) detectors. For coincidence detection of 511-keV photons, the system has a coincidence-timing circuitry for the coincidence detection of 2 events that hit the respective opposed detectors within less than a 6.5-ns timing window. Slit collimators containing thin layers of lead, tin, and copper (graded absorber) were used to prevent activity from outside the field of view. The only type of scatter that cannot be reduced by the graded absorbers is that in the crystal itself. These scatter events, termed Comptons, are 511-keV photons that collide in the crystal but lose only part of their energy, while the remaining energy leaves the crystal in the form of another photon. The energy that is measured for Compton events is <340 keV. Compton events may result in degradation in resolution but they improve sensitivity. The system offers 3 modes of operation: a high-resolution mode that uses only photopeakphotopeak (PP) coincidence pairs, a normal mode that uses photopeakCompton (PC) coincidence pairs in addition to the PP pairs, and a high-sensitivity mode that also uses ComptonCompton (CC) coincidence pairs. We used 2 combinations of energy windows: 511 keV ± 10% for PP events and 132321 keV for PC events in cases of poorer sensitivity.
Not all single photons that pass the septa collimators are accepted and processed. The manufacturers suggested optimal imaging timing after injection for the system is when the ratio between the processed photons and the detected single photons is in the range of 85%92%. This ratio was achieved in our patients between 60 to 150 min after injection.
Data acquisition lasted 30 min, corresponding to 10 rotations of the gantry. The matrix size was 128 x 128. The data were stored in a list mode (CLIST) in a 30- to 40-MB file. Reconstruction was done either on Xpert or on eNTERGA workstations. The proprietary algorithm, COSEM (coincidence list ordered set expectation maximization), which is a 3-dimensional algorithm that directly processes the CLIST, was used for the reconstruction of the CLIST (17,22).
Image Interpretation and Analysis of Results.
DHC 18F-FDG images were interpreted by 2 nuclear medicine experts who were unaware of the clinical data and the results of other imaging modalities. Abdominal lesions were called if they were detected outside the region of bowel activity, renal collecting systems, or residual urinary bladder activity. A pathologic lesion in the gastrointestinal tract was noted only if a site of increased uptake persisted on repeated acquisitions.
The final diagnosis of the imaging findings, either scintigraphic or CT, was based on histopathologic results obtained at surgery or by biopsy, on a correlation between 18F-FDG and contemporary CT and colonoscopy findings, and on clinical and CT follow-up of at least 6 mo.
Lesion-Based Analysis.
In the analysis of results of detected tumor sites, 18F-FDG or CT findings were categorized as true-positive for tumor (TP), true-negative (TN), false-positive (FP), and false-negative (FN) using similar criteria for both modalities. A scintigraphic lesion was considered TP if (a) the lesion was confirmed by biopsy; (b) CT or colonoscopy performed at the same time as the 18F-FDG study or at a later follow-up detected a pathologic lesion at the same location as 18F-FDG; or (c), in patients with elevated CEA levels and negative CT who had not undergone surgery, an 18F-FDG uptake suggestive of metastatic disease in normal-sized lymph nodes or the peritoneal seeding was considered to reflect true tumor sites if a rapid deterioration occurred clinically.
Scintigraphy was considered TN for lesions detected on CT or colonoscopy if the lesion was negative on histology or if the lesion disappeared or remained unchanged on CT for at least 6 mo without treatment.
Scintigraphy was considered FN in sites of a positive biopsy obtained within 1 mo of the 18F-FDG study or if a suspected tumor that had been revealed on CT, but not on 18F-FDG, showed progression on follow-up.
An 18F-FDG site of uptake interpreted as tumor was considered FP if it was negative for tumor histology or if there was no evidence of tumor on clinical and CT follow-up for at least 6 mo without treatment.
Patient-Based Analysis.
To assess the role of 18F-FDG in the differentiation of disease-free patients and those with recurrent or metastatic disease, a positive 18F-FDG study was considered TP if it detected tumor sites in patients with active disease and was considered TN if it was negative in disease-free patients.
Statistical Analysis
The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and 95% confidence intervals were calculated for DHC 18F-FDG and for CT (23).
| RESULTS |
|---|
|
|
|---|
|
Correlation with CT reports was available for 93 of the 103 suspected lesions: 52 were TP, 1 was TN, 9 were FP, and 31 were FN, resulting in a sensitivity of 63%, specificity of 10%, PPV of 85%, NPV of 3%, and accuracy of 57%. Table 1 summarizes the statistical results of lesion detection by DHC 18F-FDG and CT according to regions.
|
In the 18 patients referred for an 18F-FDG study because of elevated CEA levels and negative CT and colonoscopy, 12 DHC 18F-FDG studies were positive for tumor (67%), detecting abdominal lymph node involvement (n = 5), lung metastases (n = 3), peritoneal seeding (n = 2), liver metastases (n = 1), and a pelvic mass (n = 1). Figures 2 and 3 illustrate 2 of the latter patients. DHC 18F-FDG studies were negative in the other 6 patients: 3 of them continued to have no evidence of disease on follow-up, whereas the tumor sites became detectable later on follow-up CT or further DHC 18F-FDG study in the other 3 patients (2 had liver metastases, 1 had presacral lymph nodes). In this group the sensitivity was 80%, specificity was 100%, PPV was 100%, NPV was 50%, and accuracy was 83%. Seven patients were referred for surgery after the DHC 18F-FDG studies that were positive for tumor.
|
|
| DISCUSSION |
|---|
|
|
|---|
Conventional gamma cameras that are used in the routine practice of nuclear medicine for the detection of single photon emitters have been modified recently to also be applicable for the detection of positron emitters, raising the potential of imaging a greater number of patients with FDG. Attempts to improve the resolution and sensitivity of these cameras for FDG imaging include adding dual-head coincidence electronics, increasing the thickness of the NaI(Tl) crystals, and using iterative algorithms for reconstruction (17,18,30,31). The technique has been shown to have a high spatial resolution and sensitivity, but it is degraded by the proportion of scatter and random coincidence events. The limited sensitivity is a major problem that affects the quality of the images and may result in a failure to detect small lesions. Comparison of the performance of a dual-head SPECT camera operated in a coincidence mode with that of a PET scanner revealed that the coincidence technique can depict many of the lesions depicted with PET, particularly in the lungs, but has a lower sensitivity for lesion detection in the abdomen (15).
The purpose of this study was to assess the role of DHC 18F-FDG in patients with suspected recurrent CRC, a tumor known to commonly recur in the abdomen and pelvis. The results indicate an improved overall tumor detection for DHC 18F-FDG compared with CT. Although the high-resolution CT technique has a basic anatomic resolution better than that of DHC 18F-FDG, the latter was more accurate for tumor detection, particularly in the case of normal-sized metastatic lymph nodes and peritoneal spread (Figs. 24), as well as for differentiating tumor from fibrosis or changes caused by prior surgery. Abdominal and pelvic sites of physiologic 18F-FDG uptake were a potential cause for difficulties in image interpretation because the longer acquisition time of a whole-body coincidence study, compared with that of PET, is associated with filling of the bladder and the renal collecting system. These physiologic sites of 18F-FDG uptake increase the proportion of scatter events. For this reason, our patient preparation protocol included bladder catheterization and, recently, the administration of diuretics as well. In most cases, bowel activity was identifiable by its characteristic linear pattern or on 3-dimensional cine. The presence of tumor in the bowel itself was not commonly interpreted and was interpreted only if a focus of uptake was detected as being unchanged on repeated acquisitions (Fig. 4). Chest CT is not always a routine practice in the follow-up of patients with colorectal disease. The benefit of the whole-body imaging protocol of DHC 18F-FDG was reflected in the 16% rate of tumor lesions found outside the abdomen and pelvis.
|
Our study had several limitations. This was a retrospective investigation. The enrolled patients were preselected by the referring physician to undergo a DHC 18F-FDG study. The lower accuracy of the CT technique compared with that of DHC 18F-FDG is caused, in part, by a bias in patient selection because approximately one third of the study cohort was referred for scintigraphy to assess the cause of elevated CEA levels in the presence of negative CT. Reports (not films) of the CT studies were available for correlation. In addition, an accurate diagnosis of suspected tumor sites was not always possible, as often occurs in studies assessing tumor detection. Some of our patients had unresectable disease (e.g., peritoneal tumor seeding), and rapid clinical deterioration was the only indication that the scintigraphic findings might represent true tumor sites. It should be borne in mind that, when one is assessing tumor detection by a new imaging modality, some suspected tumor sites cannot be characterized histologically and, when one is comparing the results of different imaging modalities, the more sensitive technique will provide its own standard of criteria (9).
| CONCLUSION |
|---|
|
|
|---|
| ACKNOWLEDGMENTS |
|---|
| FOOTNOTES |
|---|
For correspondence or reprints contact: Einat Even-Sapir, MD, DSc, Department of Nuclear Medicine, Tel-Aviv Sourasky Medical Center, 6 Weizman St., Tel-Aviv, 64239 Israel.
E-mail: evensap{at}tasmc.health.gov.il
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
S. Bipat, M. S. van Leeuwen, E. F. I. Comans, M. E. J. Pijl, P. M. M. Bossuyt, A. H. Zwinderman, and J. Stoker Colorectal Liver Metastases: CT, MR Imaging, and PET for Diagnosis--Meta-analysis Radiology, October 1, 2005; 237(1): 123 - 131. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Even-Sapir, B. Yuzefovich, E. Miller, J.-P. Bouhnik, O. Zak, H. Lerman, G. Lievshitz, and C. Levin Coincidence Imaging Using 2 Dual-Head {gamma}-Camera Systems, With and Without Attenuation Correction J. Nucl. Med. Technol., December 1, 2004; 32(4): 190 - 197. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Even-Sapir, Y. Parag, H. Lerman, M. Gutman, C. Levine, M. Rabau, A. Figer, and U. Metser Detection of Recurrence in Patients with Rectal Cancer: PET/CT after Abdominoperineal or Anterior Resection Radiology, September 1, 2004; 232(3): 815 - 822. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |