Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherCLINICAL INVESTIGATIONS

Dynamic and Static 99mTc-ECD SPECT Imaging of Subacute Cerebral Infarction: Comparison with 133Xe SPECT

Kuniaki Ogasawara, Akira Ogawa, Masayuki Ezura, Hiromu Konno, Mamoru Doi, Kiyoshi Kuroda and Takashi Yoshimoto
Journal of Nuclear Medicine April 2001, 42 (4) 543-547;
Kuniaki Ogasawara
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Akira Ogawa
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Masayuki Ezura
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hiromu Konno
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mamoru Doi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kiyoshi Kuroda
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Takashi Yoshimoto
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

99mTc-ethylcysteinate dimer (99mTc-ECD) SPECT imaging reportedly fails to show reflow hyperemia in patients with subacute stroke. This study attempts to determine the clinical usefulness of dynamic 99mTc-ECD SPECT in evaluating regional blood flow in subacute cerebral infarction and the kinetic behavior of 99mTc-ECD in infarct areas. Methods: 133Xe and consecutive dynamic and static 99mTc-ECD SPECT studies were performed on 24 patients with cortical infarction in the middle cerebral artery territory 13–15 d after the onset of a stroke. Image contrast between infarct and contralateral control areas on 99mTc-ECD tomograms (ECD uptake ratio) was compared with that on cerebral blood flow (CBF) images obtained using 133Xe inhalation (CBF ratio). Results: In all cases, ECD uptake ratios from static images were lower than CBF ratios. This tendency was obvious when CBF in the infarct area increased above the normal control value, and no significant correlation was found between ECD uptake ratios from static images and CBF ratios. Only in the infarct areas with CBF below the normal control value, however, was a significant correlation between the two maintained (r = 0.795; P = 0.0011). A very strong correlation was found between CBF ratios and ECD uptake ratios on both the first dynamic scan (36 s after injection) (r = 0.991; P < 0.0001) and the second dynamic scan (72 s after injection) (r = 0.945; P < 0.0001). The correlation coefficient decreased in a time-dependent manner, with no significant correlation observed after the fourth dynamic scan (144 s after injection). On the other hand, significant correlations were observed on all dynamic scans only in the infarct areas with CBF below the control value. Conclusion: Super-early images of dynamic 99mTc-ECD SPECT provide a close imaging contrast with CBF and reveal reflow hyperemia in areas with irreversible changes produced by subacute stroke, which static 99mTc-ECD SPECT images fail to show. Decreased retention of the tracer in the infarct areas with hyperperfusion causes an underestimation of CBF on static 99mTc-ECD SPECT images. Given these results, we believe that dynamic 99mTc-ECD SPECT is an effective clinical tool to evaluate regional blood flow in subacute cerebral infarction.

  • 99mTc-ECD
  • subacute stroke
  • brain SPECT

In clinical practice, 99mTc-ethylcysteinate dimer (99mTc-ECD), developed as a retained-type brain perfusion tracer, has been widely used to visualize regional blood flow in the human brain with SPECT (1). Although the distribution of 99mTc-ECD in the brain correlates with regional cerebral blood flow (CBF) in healthy humans and in patients with chronic stroke (2–5), 99mTc-ECD SPECT imaging reportedly fails to show reflow hyperemia in patients with subacute stroke (5,6). 99mTc-ECD is a lipophilic agent that penetrates the normal blood–brain barrier and is retained by conversion of lipophilic molecules into hydrophilic compounds. The tracer is hydrolyzed to polar metabolites by deesterification (1), and thus 99mTc-ECD activity is decreased in damaged brain tissue with normo- or hyperperfusion (4–9). On the other hand, SPECT imaging contrast 60 s after 99mTc-ECD injection that matches that of CBF images has been found only in the misery perfusion of brain ischemia and the luxury perfusion of acute herpes encephalitis (10,11).

This study attempts to determine the clinical usefulness of 99mTc-ECD SPECT with dynamic scanning in evaluating regional blood flow in subacute cerebral infarction and the kinetic behavior of 99mTc-ECD in infarct areas.

MATERIALS AND METHODS

Patients

Twenty-four patients (10 women, 14 men; age range, 39–78; mean age ± SD, 58 ± 11 y) admitted to Kohnan Hospital between June and December 1994 with subacute cerebral infarction associated with cerebral embolism were enrolled in the study (Table 1). At Kohnan Hospital, the first choice of treatment for cerebral embolism is local intra-arterial thrombolysis using recombinant tissue plasminogen activator. Treatment selection is based on three criteria: the patient has been hospitalized within 6 h of onset; no hypodensity is observed on a CT scan on admission; and occlusion is present in the middle cerebral artery (MCA). All patients who do not meet these criteria receive only conservative systemic care. To avoid inducing a deterioration of hemorrhagic transformation caused by delayed recanalization, we never administer medication that may affect the function of thrombocytes or the coagulation–fibrinolysis system. Mannitol or glycerol is administered for ischemic brain edema or hemorrhagic transformation. When this treatment is ineffective and brain herniation progresses, mild hypothermia or decompressive hemicraniotomy is performed. Thus, the subjects of this study did not meet our criteria for local intra-arterial thrombolysis and did not require mild hypothermia or decompressive hemicraniotomy.

View this table:
  • View inline
  • View popup
TABLE 1

Patient Clinical Data

Cerebral angiography was performed within 24 h of the onset of symptoms in all patients. Three patients presented with occlusions in the internal carotid artery and 16 presented with occlusions in the MCA. Angiographic occlusions were not evident in 5 patients. CT scans or MR images obtained 1 wk after the onset of the stroke revealed massive cortical infarction in the MCA territories of all patients.

Informed consent was obtained from all patients or their next of kin, and the study was approved by the ethics committee of Kohnan Hospital.

SPECT Imaging

A SPECT study was performed on all patients 13–15 d after the onset of stroke. SPECT images were obtained using a multidetector ring-type scanner, consisting of 64 NaI crystals in a 38-cm-diameter circle in the detector array. After tomographic reconstruction, the spatial resolution and slice thickness in the center of the plane were 9 and 16 mm, respectively, with full width at half maximum (FWHM) for static imaging and 20 and 25 mm FWHM for dynamic imaging. The energy window in this study was 140 keV (±15%). Projection data for static and dynamic imaging were processed using Ramachandran’s filtered backprojection after the introduction of a Butterworth prefilter. A 64 × 64 (99mTc-ECD static) or 32 × 32 (99mTc-ECD dynamic and 133Xe) image matrix was used.

Patients were administered the tracer in a quiet, dimly lit room while resting with their eyes open. The patient’s head was immobilized with a ready-made plastic head holder so that the bilateral external auditory meatus were aligned to the machine-indwelling positioning crossed-light beam. To reproduce the same head position for all SPECT studies, three markers were affixed on the head under the guidance of a light beam. Of the three markers, two were placed on the anterior edge of the bilateral external auditory meatus, and one was placed on the midline of the nose ridge. The three markers lay along a plane perpendicular to the axis of camera rotation.

Patients inhaled 1,480 MBq 133Xe gas for 1 min, and sequence SPECT imaging was performed every minute for 10 min using a high-sensitivity collimator. Quantitative CBF maps were reconstructed using the Kanno–Lassen method (12). 99mTc-ECD was prepared from a commercially supplied kit that contained no radioactivity, and [99mTc]pertechnetate was obtained from a molybdenum–technetium generator. Fifteen minutes after obtaining the 133Xe SPECT scan, each patient received an intravenous bolus injection of ∼900 MBq 99mTc-ECD. Dynamic scanning with a high-sensitivity collimator was started simultaneously and continued for a total of 288 s (eight scans) with a scan-time duration of 36 s. Static SPECT imaging with a high-resolution collimator proceeded 10 min after the tracer injection. Tomographic data were obtained continuously over a 20-min period (Fig. 1).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Protocol for consecutive 133Xe and dynamic and static 99mTc-ECD SPECT imaging.

From among the axial slices, we selected one through the basal ganglia and then visually and manually drew one 11.1-cm2 region of interest (ROI) in the infarct area shown on CT scans or MR images. The control ROI was mirrored onto the contralateral side, and the same set of ROIs was used for all SPECT studies. Image contrast between infarct and contralateral control areas on 99mTc-ECD tomograms (ECD uptake ratio) was compared with that on CBF images using 133Xe inhalation (CBF ratio).

Statistical Analysis

We determined correlations between various parameters by linear regression analysis and by computing regression equations and correlation coefficients. Statistical significance was set at P < 0.05.

RESULTS

The dynamic 99mTc-ECD SPECT images of a representative patient (patient 24) with cortical infarction in the right MCA territory showed that maximum brain activity of 99mTc-ECD was found on the second scan (72 s after injection), which provided a close imaging contrast with 133Xe CBF; the activity in the contralateral control area was followed by some loss and a plateau, whereas that in the lesion decreased rapidly to below the activity in the contralateral area (Fig. 2). Static 99mTc-ECD SPECT revealed a focal area of hypoactivity corresponding to the lesion shown on the MR image.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Patient 24. (A) T2-weighted MR image obtained 7 d after onset of initial symptoms reveals infarction in right MCA territory. (B) Dynamic 99mTc-ECD SPECT images show increased tracer concentration in infarct area in second scan (72 s after injection). Thereafter, 99mTc-ECD activity in lesion rapidly decreases to below that in contralateral area. (C) Static 99mTc-ECD SPECT image (left) shows focal hypoactivity corresponding to lesion detected on MRI. Same region shows marked hyperperfusion on 133Xe tomogram (right).

ECD uptake ratios from static images were lower than CBF ratios from all infarct areas (Fig. 3C). This tendency was obvious when CBF in the infarct area increased above the mean value of the control group (46.1 mL/100 g/min) obtained from 10 healthy volunteers (age range, 35–65 y; mean age, 52.3 y). Although no significant correlation was found between ECD uptake ratios on static images and CBF ratios (r = 0.109), a significant correlation between the two was maintained (r = 0.795; P = 0.0011) just for the infarct areas with CBF below the mean value of the control group. A very strong correlation existed between CBF ratios and ECD uptake ratios on both the first dynamic scan (36 s after injection) (r = 0.991; P < 0.0001) and the second dynamic scan (72 s after injection) (r = 0.945; P < 0.0001) (Figs. 3A and B). In the infarct area with CBF greater than the mean value of the control group, ECD uptake ratios on the first dynamic scan were higher than CBF ratios. In contrast, ECD uptake ratios on the second dynamic scan fell below CBF ratios. The correlation coefficient decreased in a time-dependent manner, with no significant correlation observed after the fourth dynamic scan (144 s after injection) (Table 2). However, significant correlations were observed on all dynamic scans only in the infarct areas with CBF less than the mean value of the control group.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Relationships between relative 99mTc-ECD activity and relative CBF on first dynamic images (36 s after injection) (A), second dynamic images (72 s after injection) (B), and static images (C). Strong linearity between relative 99mTc-ECD activity and relative CBF is observed in first and second dynamic images. In infarct area with CBF > 46.1 mL/100 g/min, relative 99mTc-ECD activity on first dynamic scan exceeds relative CBF. In contrast, relative 99mTc-ECD activity in second dynamic scan is lower than relative CBF. Correlation between these in static images is not significant, whereas significant correlation is observed only in infarct areas with CBF < 46.1 mL/100 g/min. Dashed line represents line of identity. n.s. = not significant.

View this table:
  • View inline
  • View popup
TABLE 2

Relationship Between ECD Uptake Ratios and CBF Ratios

DISCUSSION

Our findings indicate that super-early images of dynamic 99mTc-ECD SPECT provide a close imaging contrast with CBF and reveal reflow hyperemia in areas with irreversible changes produced by subacute stroke that static 99mTc-ECD SPECT images fail to show. We also showed that decreased retention of the tracer in infarct areas with hyperperfusion causes an underestimation of CBF on static 99mTc-ECD SPECT images.

Flow tracer accumulation in the brain is influenced by various regulating factors depending on the scan time after tracer injection. In the super-early phase of tracer injection, the first-pass extraction fraction greatly affects brain tracer distribution. When the fraction of the tracer extracted from the blood into the brain is high and rapid scanning is sufficient to obtain the initial slope of the brain tracer input, the image is close to CBF (10). Thus, we hypothesized that even in subacute infarction, scanning in the super-early phase after a 99mTc-ECD injection is influenced negligibly by a complicated interaction of factors such as the backdiffusion of tracer from the lipophilic component in the brain to the blood or metabolic products in the blood. The results of our study show that super-early images within 2 min after intravenous injection of 99mTc-ECD provide a close imaging contrast with CBF in patients with subacute stroke.

However, on the first dynamic images, ECD uptake ratios were higher than CBF ratios in infarct areas with hyperperfusion. Radioactivity in arterial blood of 99mTc-ECD administered intravenously as a bolus injection reaches a maximum at 1 min after injection, which is followed by a steep decrease and a plateau at about 5 min after injection (4). Most of the tracer is present in the intravascular compartment at 30 s after injection. Regions of subacute cerebral infarction exhibit increased cerebral blood volume because of vasoparalysis or vasodilatation associated with metabolic acidosis (13). Therefore, the first dynamic images of 99mTc-ECD would overestimate CBF as a result of the cerebral blood pool effect of the tracer in the infarct area.

In contrast, the second dynamic image of 99mTc-ECD SPECT underestimated CBF in the infarct area with hyperperfusion. This tendency became more obvious in a time-dependent manner, and the correlation coefficient between ECD uptake ratios and CBF ratios decreased. As a result, dynamic images at 3 min after injection did not reveal regional blood flow. On the other hand, linearity between ECD uptake ratios and CBF ratios was observed on all dynamic images and even on static images only in the infarct areas without hyperperfusion. 99mTc-ECD, transformed by intracellular esterases from a diester to a diacid complex, cannot cross the intact cell membrane and is trapped in the neural cell (1,14). Thus, the retention of 99mTc-ECD in the damaged brain depends on various factors such as the severity of blood–brain barrier breakdown and cytosolic esterase activity (10,11). Our findings suggest that hyperperfusion in infarct areas is more strongly related to decreased retention of 99mTc-ECD in patients with subacute stroke than any other factor. Furthermore, although static 99mTc-ECD SPECT images may provide a mix of information that reflects blood–brain barrier breakdown, cerebral metabolism, and CBF, our findings also suggest that static 99mTc-ECD SPECT images reveal regional blood flow in infarct areas without hyperperfusion.

In recent years, the development of a multihead gamma camera with high sensitivity and spatial resolution has made the measurement of regional CBF during low brain radioactivity possible. This measurement should enable super-early SPECT images to be obtained routinely in many institutions in the near future.

CONCLUSION

In areas with irreversible changes produced by subacute stroke, super-early dynamic 99mTc-ECD SPECT images provided a close imaging contrast with CBF and revealed reflow hyperemia, which static 99mTc-ECD SPECT images failed to show. Decreased retention of the tracer in the infarct areas with hyperperfusion caused an underestimation of CBF in static 99mTc-ECD SPECT images. Given these results, we believe that dynamic 99mTc-ECD SPECT is an effective clinical tool to evaluate regional blood flow in subacute cerebral infarction.

Acknowledgments

This work was supported in part by Grants-in-Aid for Advanced Medical Scientific Research by the Ministry of Science, Education, Sports and Culture, Japan.

Footnotes

  • Received Jul. 5, 2000; revision accepted Dec. 11, 2000.

    For correspondence or reprints contact: Kuniaki Ogasawara, MD, Department of Neurosurgery, Iwate Medical University, 19-1 Uchimaru, Morioka, 020-8505 Japan.

REFERENCES

  1. ↵
    Walovitch RC, Hill TC, Garrity ST, et al. Characterization of technetium-99m-L,L-ECD for brain perfusion imaging. Part 1. Pharmacology of technetium-99m-ECD in nonhuman primates. J Nucl Med 1989;30:1892–1901.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    Leveille J, Botez MI, Taillefer R, Gagnon A, Douesnard JM, Lefebvre B. A clinical comparison of Tc-99m HMPAO and Tc-99m ethyl cysteinate dimer (ECD) in normal volunteers and patients as a brain perfusion imaging agent [abstract]. J Nucl Med 1988;29.(suppl):P844.
  3. Devous MD, Leroy RF, Payne JK, Lorimer MK, Bonte FJ. Comparison of Tc-99m ECD to Xe-133 in the SPECT determination of regional cerebral blood flow in patients with mild perfusion abnormalities [abstract]. J Nucl Med 1990;31.(suppl):P817.
  4. ↵
    Shishido F, Uemura K, Murakami M, et al. Cerebral uptake of 99mTc-bicisate in patients with cerebrovascular disease in comparison with CBF and CMRO2 measured by positron emission tomography. J Cereb Blood Flow Metab 1994;14.(suppl 1):S66–S75.
  5. ↵
    Lassen NA, Sperling B. 99mTc-bicisate reliably images CBF in chronic brain diseases but fails to show reflow hyperemia in subacute stroke: report of a multicenter trial of 105 cases comparing 133Xe and 99mTc-bicisate (ECD, Neurolite) measured by SPECT on the same day. J Cereb Blood Flow Metab 1994;14.(suppl 1):S44–S48.
  6. ↵
    Nakagawara J, Nakamura J, Takeda R, et al. Assessment of postischemic reperfusion and diamox activation test in stroke using 99mTc-ECD SPECT. J Cereb Blood Flow Metab 1994;14.(suppl 1):S49–S57.
  7. Shishido F, Uemura K, Inugami A, et al. Discrepant 99mTc-ECD images of CBF in patients with subacute cerebral infarction: a comparison of CBF, CMRO2 and 99mTc-HMPAO imaging. Ann Nucl Med 1995;9:161–166.
    OpenUrlPubMed
  8. Tamagac F, Moretti JLM, Defer G, Weinmann P, Roussi A, Cesaro P. Nonmatched images with 123I-IMP and 99mTc-bicisate single-photon emission tomography in the demonstration of focal hyperaemia during the subacute phase of an ischaemic stroke. Eur J Nucl Med. 1994;21:254–257.
    OpenUrlPubMed
  9. ↵
    Moretti JLM, Tamagac F, Weinmann P, et al. Early and delayed brain SPECT with technetium-99m-ECD and iodine-123-IMP in subacute strokes. J Nucl Med 1994;35:1444–1449.
    OpenUrlAbstract/FREE Full Text
  10. ↵
    Shimosegawa E, Hatazawa J, Aizawa Y, et al. Technetium-99m-ECD brain SPECT in misery perfusion. J Nucl Med 1997;38:791–796.
    OpenUrlAbstract/FREE Full Text
  11. ↵
    Fazekas F, Roob G, Payer F, Kapeller P, Strasser-Fuchs S, Aigner RM. Technetium-99m-ECD SPECT fails to show focal hyperemia of acute herpes encephalitis. J Nucl Med 1998;39:790–792.
    OpenUrlAbstract/FREE Full Text
  12. ↵
    Kanno I, Lassen NA. Two methods for calculating regional cerebral blood flow from computed tomography of inert gas concentrations. J Comput Assist Tomogr 1979;3:71–76.
    OpenUrlPubMed
  13. ↵
    Cordes M, Henkes H, Roll D, et al. Subacute and chronic cerebral infarctions: SPECT and gadolinium-DTPA enhanced MR imaging. J Comput Assist Tomogr 1989;13:567–571.
    OpenUrlPubMed
  14. ↵
    Jacquier-Sarlin MR, Polla BS, Slosman DO. Cellular basis of ECD brain retention. J Nucl Med 1996;37:1694–1697.
    OpenUrlAbstract/FREE Full Text
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 42, Issue 4
April 1, 2001
  • Table of Contents
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Dynamic and Static 99mTc-ECD SPECT Imaging of Subacute Cerebral Infarction: Comparison with 133Xe SPECT
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Dynamic and Static 99mTc-ECD SPECT Imaging of Subacute Cerebral Infarction: Comparison with 133Xe SPECT
Kuniaki Ogasawara, Akira Ogawa, Masayuki Ezura, Hiromu Konno, Mamoru Doi, Kiyoshi Kuroda, Takashi Yoshimoto
Journal of Nuclear Medicine Apr 2001, 42 (4) 543-547;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Dynamic and Static 99mTc-ECD SPECT Imaging of Subacute Cerebral Infarction: Comparison with 133Xe SPECT
Kuniaki Ogasawara, Akira Ogawa, Masayuki Ezura, Hiromu Konno, Mamoru Doi, Kiyoshi Kuroda, Takashi Yoshimoto
Journal of Nuclear Medicine Apr 2001, 42 (4) 543-547;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Prognostication of Recovery in Patients With Acute Ischemic Stroke Through the Use of Brain SPECT With Technetium-99m--Labeled Metronidazole
  • Abnormal regional cerebral blood flow on 99mTc ECD brain SPECT in patients with primary Sjogren's syndrome and normal findings on brain magnetic resonance imaging
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire