|
|
||||||||
Departments of Cardiology and Nuclear Medicine, Ospedale di Circolo and Fondazione Macchi-University Hospital, Varese, Italy
| ABSTRACT |
|---|
|
|
|---|
Key Words: sestamibi SPECT coronary blood flow atherosclerosis intracoronary sonography
| INTRODUCTION |
|---|
|
|
|---|
| MATERIALS AND METHODS |
|---|
|
|
|---|
99mTc-Sestamibi SPECT
Myocardial perfusion SPECT was performed with a 2-d stressrest protocol. Each patient received 800925 MBq 99mTc-sestamibi (reconstituted from Cardiolite kits [Du Pont Merck Pharmaceuticals, Wilmington, DE]) intravenously either at baseline or during exercise stress testing. The images were acquired 1 h after injection using a rotating single-head gamma camera (Prism 1000XP; Picker, Cleveland, OH) equipped with a low-energy high-resolution parallel-hole collimator. Sixty images were obtained on a 64 x 64 matrix for 15 s, throughout a 180° arc, beginning at the 45° right anterior oblique projection and ending at the 45° left posterior oblique projection. Transaxial reconstruction was achieved using a standard backprojection algorithm and a Butterworth filter with a cutoff frequency of 0.21 Nyquist (0.18 cycles per centimeter) and an order of 4. The transaxial sections were then used to generate oblique sections reoriented along the horizontal and vertical long and short axes of the left ventricle. The images were analyzed by 3 experienced readers who did not know the results of the coronary angiography and intravascular sonography studies, using the datasets of the stressrest images. Disagreements were resolved by consensus. For each study, the observers evaluated 8 short-axis, 8 vertical long-axis, and 8 horizontal long-axis slices together with the polar map of the left ventricle image. A perfusion abnormality on the stress image showing partial or complete normalization on the rest image was designated as a reversible defect indicating inducible myocardial ischemia. A semiquantitative score was used to describe the extent and severity of the perfusion defects on the basis of a 13-segment model of the polar plot of the ventricular wall and a 5-point scale ranging from 0 (normal uptake) to 4 (no uptake). The summed reversible defect score was then computed by subtracting the rest score from the summed stress score of all segments (14,15). The septal and anterior myocardial segments were matched to the left anterior descending coronary artery; the inferior, inferoapical, and posterior myocardial segments were matched to the right coronary artery; and the lateral myocardial segments were matched to the left circumflex coronary artery.
Coronary Angiography
Coronary angiography was performed using the Judkins technique and the right femoral artery approach. All angiograms were filmed at 25 frames per second in multiple pairs of orthogonal views using a monoplane multidirectional isocentric radiologic system (Integris 2000 Cardiac; Philips Medical Systems, Best, The Netherlands), and images were interpreted semiquantitatively by 2 experienced angiographers. Quantitative coronary analysis was performed using the diameter of the contrast-free diagnostic catheter for calibration of image magnification. The vessel diameter, the minimal lumen diameter, and the percentage of diameter stenosis were measured at any narrowing site of the investigated vessels using an automatic edge detection computer-assisted analysis system (QCA; Philips).
Intracoronary Doppler Velocity Measurements
After administration of 30005000 IU intravenous heparin, adjusted for body weight, an 8-French guiding catheter was used to cannulate the ostium of the coronary arteries and a 0.014-in. floppy intracoronary Doppler guidewire (Flowire; Cardiometrics Inc., Mountain View, CA) was advanced distally into a major branch of the coronary artery system and positioned to obtain the best-quality phasic signal of blood flow velocity. Doppler flow velocities were continuously displayed on the Doppler sonography instrument (Flowmap; Cardiometrics) and recorded on a videotape. Spectral variables were calculated including the average peak velocity and the ratio of the average diastolic to the average systolic peak velocities. Maximal hyperemia was induced by intracoronary bolus injection of adenosine (12 µg for the right coronary artery and 18 µg for the left coronary artery). The coronary flow velocity reserve (CFR) was calculated as the ratio between hyperemic average peak velocity and basal average peak velocity, as previously described (912). According to other studies (912) and our own experience (12), a CFR less than 2.5 was considered to be abnormal. All measurements were repeated in at least 2 major coronary arteries per patient. Each vessel was classified, according to perfusion scans, as supplying abnormal territories (target vessel) or normal segments (reference vessel). When measurements from more than 1 vessel supplying normal segments were available, the mean value of CFR was used. The ratio of the CFR of the target vessel and the reference vessel (coronary reserve ratio) was calculated as an index of the relative vasodilation capacity of the affected territory (16,17).
Intracoronary Sonography
After flow velocity measurement, the Doppler guidewire was left in place and used to advance the sonography catheter as far distal as possible in each vessel. Intracoronary nitroglycerine, 0.10.3 mg, was administered to avoid spasm and to achieve maximum vasodilation of the epicardial vessels. Imaging was performed using intravascular sonographic 2.9- or 3.2-French monorail catheters with polyethylene sheaths (Boston Scientific Corporation, Watertown, MA) incorporating a single-element 30-MHz transducer rotating at 1800 rpm. The intracoronary sonograms were obtained with a Sonos intravascular imaging system (Hewlett-Packard, Palo Alto, CA) and recorded on a videotape for offline analysis. During the study, the imaging catheter was slowly withdrawn manually under fluoroscopic guidance and cross-sectional images of the distal, mid, and proximal sections of the vessel were obtained. During pullback, stop frames were taken at every 58 mm of vessel until plaque formation or an abnormality of the coronary wall was found. Atherosclerotic changes in the arterial wall, significant plaque formation, and intimal thickening were defined according to the guidelines for classification and analysis of intracoronary sonograms of the Working Group of Echocardiography of the European Society of Cardiology (13). Stop frames were obtained every 3 mm at the plaque site for quantitative analysis. The lumen area (LA) was determined by computer-assisted planimetry of the lumenvessel wall interface. The vessel area (VA) was measured by planimetry of the area bounded by the middle echolucent zone (media) and the inner echoreflective adventitial interface. The plaque area (PA) was then calculated as VA LA, and the cross-sectional relative PA (RPA) was calculated as RPA = PA/VA x 100 and used as an index of the plaque burden at the site of maximal atherosclerotic involvement. A significant plaque burden was defined according to previous publications as a plaque involving more than 40% of the VA (13).
Statistical Analysis
The reproducibility of Doppler velocity signals and dimension measurements from intracoronary sonograms was previously evaluated in our laboratory, yielding mean interobserver and intraobserver variabilities of 7.1% and 4.2%, respectively, which are in keeping with previous reports (911,13). Data were expressed as mean values ± 1 SD. Where appropriate, the 2-tailed unpaired t test, the
2 test, and ANOVA were used to assess statistical significance, with P < 0.05 considered significant. Regression coefficients were obtained using linear regression analysis.
| RESULTS |
|---|
|
|
|---|
Intracoronary sonograms showed occult atherosclerotic changes unrecognized by angiography in 19 patients (95%). A significant plaque burden (RPA > 40%) was seen in 16 patients (80%). Four patients (20%) showed minor changes, including localized intimal thickening or small, soft, and eccentric plaque formation. Ten patients (50%) had only mild atherosclerosis, with focal plaque formation and an eccentric distribution of mixed (fibroadipous) or soft plaque tissue with no calcifications. Five additional subjects (25%) showed more diffuse changes, including more concentric and calcified lesions. Plaque formation was observed more frequently in the target vessel than in the reference vessels of each patient (70% versus 15%;
2 = 9.97; P < 0.0001). Mean RPA was significantly greater in the target vessels (46% ± 14%) than in the reference vessels (12% ± 18%; P < 0.0001) (Fig. 1). Measurements of Doppler flow velocity showed abnormal vasodilator capacity during adenosine infusion (CFR < 2.5) in 14 patients (70%). Again, mean CFR was significantly lower in the target vessels than in the reference vessels (2.3 ± 0.5 versus 3.1 ± 0.6; P < 0.0001) (Fig. 2). A significant inverse correlation was present between the summed reversible score and the coronary reserve ratio (y = 9.05x 9.9; r = 0.70; P < 0.005) (Fig. 3), indicating that abnormal perfusion scans were actually associated with significant heterogeneity of the coronary vasodilation capacity. Typical intravascular sonography, myocardial perfusion, and coronary angiographic findings from a study patient are shown in Figure 4.
|
|
|
|
| DISCUSSION |
|---|
|
|
|---|
Technical improvements in myocardial perfusion tracers and image quality, such as attenuation correction and electrocardiographic gating of tomographic images, have been introduced to attempt to reduce the frequency of artifactual defects (57). Nevertheless, reversible perfusion defects have been reported in up to 27% of selected patients with angina and normal findings on coronary angiography (1822). Perfusion abnormalities have also been described in asymptomatic patients with familial hypercholesterolemia (23) and systemic hypertension (24). The issue of whether abnormal scan findings should represent true perfusion changes or may be interpreted as false-positive remains controversial in nuclear cardiology. Arguments in favor of false-positive results are based on the presence of artifacts, whereas arguments for true coronary flow abnormalities are based on the presence of microcirculatory impairment or endothelial dysfunction. Impairment in coronary vasodilation reserve has been shown in patients with angina and normal coronary angiograms and has been attributed to the presence of coronary microvascular dysfunction (25). Although the evidence of a role for small-vessel disease is good, Wiedermann et al. (26) reported that in most patients presenting with this syndrome, intravascular sonography also shows abnormal epicardial coronary arteries. Early atheromatous plaques and intimal thickening, missed by coronary angiography, were associated with an abnormal (constrictive) response to exercise. This anatomic and physiologic heterogeneity in patients with angina and normal coronary angiography findings has been confirmed in a combined intracoronary sonography and Doppler flow velocity study by Erbel et al. (27). In that study, occult atherosclerosis and plaque formation were found in the left anterior descending and left main coronary arteries of 48% of 44 patients with chest pain and normal coronary angiography findings. Of the 44 patients included in that study, SPECT images were available for only 29 (66%) but showed abnormal findings in 93% of patients with abnormal sonography findings and in only 28% of patients with normal vessels. Only a minority of patients (16%) showed reduced coronary flow reserve in the absence of plaque formation by intracoronary sonography (true microvascular dysfunction). Measurements of coronary flow reserve were obtained with a Doppler catheter positioned in only the proximal left anterior descending artery, using intracoronary papaverine as the hyperemic agent. Measurements were not obtained from other vessels, and the territories corresponding to the location of perfusion defects were not separated from reference territories. Likewise, intracoronary sonograms were obtained from only the left anterior descending and left main coronary arteries. SPECT with 99mTc-methoxyisobutyl isonitrile was performed on only 29 patients (66%) and was visually interpreted and categorized as positive or negative without details on defect size and location.
Our study confirms the observation of Erbel et al. (27) that early signs of atherosclerosis missed by coronary angiography are common in patients with angina and normal coronary arteries. Moreover, we have shown that early signs of atherosclerosis revealed by coronary sonography are more frequent, and usually more advanced, in the coronary territory corresponding to myocardial perfusion defects than in the reference territories.
In addition, with the Doppler guidewire technique we evaluated regional CFR in the bed distribution of either the abnormal scintigraphic segment or the reference regions. A reduction in coronary flow reserve was more frequent in the distribution of perfusion defects than in the reference territory. We also found a significant relationship between the scintigraphic perfusion defect score and the relative impairment of the coronary flow reserve as assessed by the CFR ratio.
The relationship between regional abnormalities of perfusion scans and coronary flow reserve has been investigated in previous studies using different techniques. One of the earlier studies (21) was performed in a few patients with abnormal planar thallium imaging using digital angiography to measure coronary flow reserve and a relatively weak hyperemic agent such as contrast medium. In this study, we used tomographic sestamibi imaging, selective intravascular flow velocity measurements, and intracoronary adenosine as the hyperemic agent. Adenosine testing has been shown to induce a perfusion defect in the same area and to the same extent as the perfusion defect observed at exercise in patients with syndrome X (28) and in patients with coronary artery disease (16,29). Measurement of CFR with Doppler guidewires has been shown to be accurate and reproducible in human studies and to permit selective access to distal vessels and side branches (9,16).
This study provides new evidence supporting the concept that an abnormal scintigraphy finding, rather than being false-positive, may be an early marker of vasomotion changes associated with occult atherosclerosis in patients with angina and normal coronary angiography findings. The pathophysiologic link between early atherosclerotic changes of the epicardial vessels and an abnormal vasodilation capacity of the underlying microvasculature remains elusive. Several complex mechanisms may be involved in the regulation of coronary vasomotion in early atherosclerosis (22,30). Endothelial dysfunction has been found to be associated with the early stages of atherosclerotic involvement of the coronary epicardial vessels in humans (30). In addition, reports show that impairment of endothelium-dependent coronary vasodilation may result in myocardial perfusion defects (31). The small cohort of patients included in this study did not allow an evaluation of the relative influence of coronary risk factors and cholesterol levels on coronary vasomotion and perfusion changes. Among conventional coronary risk factors, serum cholesterol levels have been found to affect vasomotion of human coronary arteries (30,32). Also, short-term cholesterol lowering has been found to possibly decrease the size and severity of perfusion abnormalities revealed by PET in patients with coronary artery disease (32).
The study had some limitations. We studied a relatively small and selected population of consecutive patients with chest pain and angiographically normal coronary arteries who had abnormal stress perfusion findings. Patients with cardiomyopathy, atypical chest pain, or left bundle branch block were excluded. The mean age was 58.9 ± 10 y, and most patients had typical symptoms and coronary risk factors. Consistent evidence of myocardial ischemia was present in most patients andof particular note3 patients presented with a history of unstable angina and 5 had a history of nonQ wave myocardial infarction. Therefore, a possible criticism to our observations is that atherosclerotic and vasomotion changes may be a nonspecific finding in a population expected, on the basis of clinical presentation, to have a high prevalence of atherosclerotic disease. However, the close relationship between the distribution of regional perfusion abnormalities and the atherosclerotic and vasomotion changes observed in the related vessel make this possibility unlikely.
Doppler flow velocity and intravascular sonography measurements have few well-known limitations or pitfalls. However, several studies have shown the overall accuracy of these techniques either in patients with overt coronary artery disease or in patients with chest pain and insignificant disease (13,16).
| CONCLUSION |
|---|
|
|
|---|
| FOOTNOTES |
|---|
For correspondence or reprints contact: Luca Ceriani, MD, Department of Nuclear Medicine, Ospedale di Circolo and Fondazione Macchi, Viale Borri, 57, I-21100 Varese, Italy.
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
S. Hallerstam, P. T. Larsson, E. Zuber, and S. Rosfors Carotid Atherosclerosis is Correlated with Extent and Severity of Coronary Artery Disease Evaluated by Myocardial Perfusion Scintigraphy Angiology, May 1, 2004; 55(3): 281 - 288. [Abstract] [PDF] |
||||
![]() |
L. De Luca, F. Bovenzi, D. Rubini, A. Niccoli-Asabella, G. Rubini, and I. de Luca Stress-Rest Myocardial Perfusion SPECT for Functional Assessment of Coronary Arteries with Anomalous Origin or Course J. Nucl. Med., April 1, 2004; 45(4): 532 - 536. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Voudris, D. Avramides, M. Koutelou, J. Malakos, A. Manginas, M. Papadakis, and D. V. Cokkinos Relative Coronary Flow Velocity Reserve Improves Correlation With Stress Myocardial Perfusion Imaging in Assessment of Coronary Artery Stenoses Chest, October 1, 2003; 124(4): 1266 - 1274. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. S. Blumenthal, D. M. Becker, L. R. Yanek, T. R. Aversano, T. F. Moy, B. G. Kral, and L. C. Becker Detecting Occult Coronary Disease in a High-Risk Asymptomatic Population Circulation, February 11, 2003; 107(5): 702 - 707. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Fagret, C. Ghezzi, and G. Vanzetto 99mTc-N-NOET Imaging for Myocardial Perfusion: Can It Offer More Than We Already Have? J. Nucl. Med., September 1, 2001; 42(9): 1395 - 1396. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |