Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherDEPARTMENTS

99mTc-Apcitide Scintigraphy and the Detection of Acute Deep Vein Thrombosis

Pierre Weinmann and Jean-Luc Moretti
Journal of Nuclear Medicine October 2000, 41 (10) 1768-1769;
Pierre Weinmann
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jean-Luc Moretti
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

TO THE EDITOR:

In a recent study, Taillefer et al. (1) reported encouraging results in the detection of acute deep vein thrombosis (ADVT) by 99mTc-apcitide, a synthetic glycoprotein IIb/IIIa receptor-binding peptide. The authors reported a sensitivity of 86.4% in the detection of ADVT when early and delayed sets of images were analyzed together. However, the inclusion of patients (7/22) with discordant results of scintigraphy (i.e., association of negative and positive results on the 3 sets of images) may be misleading and should be discussed.

Five of 7 patients displayed late positivity only. This result could be explained by a low activity of the thrombus. Inclusion of these patients among the positive results can be accepted. However, 2 patients had early positivity only, with negative results at 120 min, and were included when all datasets were considered. The critical question is why does a thrombus result in early positive and late negative images? This could be explained by the hemodynamic action of the thrombus, which, though no longer active, delays the regional blood-pool clearance. However, other conditions that mimic ADVT in daily practice may also delay the regional blood-pool clearance (e.g., calf cellulitis and calf hematoma). Therefore, to include patients with positive early results only is questionable and may have deleterious therapeutic implications such as prescription of an anticoagulant in a patient with calf hematoma.

Takatsu and Fujiwara (2) correctly stated in their editorial that contrast-enhanced venography, although considered the gold standard, has real limitations. They argued that the accuracy of 99mTc-apcitide scintigraphy for detecting ADVT might be much higher than that obtained in this study. Their statement is valid for only 2 of 17 patients with late positive scintigraphy and negative contrast-enhanced venography. Their statement is not relevent however for the 3 patients (of 22) with proven ADVT and negative scintigraphy. Therefore, the sensitivity of 99mTc-apcitide scintigraphy to detect ADVT is lower than contrast-enhanced venography in this small series of patients. The sensitivity seems to be 76% when early positivity only is not considered. If the 2 patients with late positive scintigraphy and negative contrast-enhanced venography were assumed to have ADVT that was not detected by the gold-standard technique, this would lead to a sensitivity of 78% (18/23).

ADVT diagnosis is a tough clinical challenge. Because of the major potential complications of ADVT, a new diagnostic tool should have a sensitivity that is at least equal to a reference technique. Regarding the results of this preliminary study, we cannot share the optimism of the authors of this paper and editorial.

REFERENCES

  1. ↵
    Taillefer R, Thérasse E, Turpin S, et al. Comparison of early and delayed scintigraphy with 99mTc-apcitide and correlation with contrast-enhanced venography in detection of acute deep vein thrombosis. J Nucl Med 1999;40:2029–2035.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    Takatsu H, Fujiwara H. Imaging of the “active” thrombus: can it be a new gold standard for acute deep vein thrombosis? J Nucl Med 1999;40:2036–2037.
    OpenUrlFREE Full Text

Reply:

We thank Drs. Weinmann and Moretti for their comments and note their concern over the inclusion in our study (1) of patients with discordant results on the 3 sets of 99mTc-apcitide images, which suggested that the final overall sensitivity of the test was “falsely” high.

As stated in our article (1), the major purpose of our study was to compare the diagnostic accuracy of early and delayed 99mTc-apcitide scintigraphy in patients with suspected acute deep vein thrombosis (ADVT) of the lower extremities. The major conclusion of the study was that although images obtained at 2 h after 99mTc-apcitide injection show the greatest overall accuracy compared with earlier images, combined analysis of image sets from at least 2 time points provides greater accuracy in the detection of ADVT. Therefore, it was clear that it was necessary to use both static and temporal criteria to obtain a high diagnostic accuracy. Although the 3 sets of images were all positive for a given patient in 54.5% (12/22) of patients with proven ADVT, 99mTc-apcitide studies with false-negative findings in 1 or more sets of images were seen in 10 cases. 99mTc-apcitide scintigraphy was positive in at least 2 sets of images in 3 cases, positive only on the delayed images in another 3 cases, and totally negative in 3 patients. 99mTc-apcitide scintigraphy was positive at 10 min in 1 patient only (and not in 2 patients as stated in the above Letter to the Editor). In this particular case, in a subanalysis looking at the diagnostic certainty of the test (not published yet), the 99mTc-apcitide study was read as definitely abnormal at 10 min and probably normal at 60 and 120 min, although the asymmetry of the vascular uptake was persistent but judged to be not significant on the separate reading by the observers who were blinded to the experiment. After the 3 images had been analyzed together, the observers agreed that this case should be read as positive for ADVT, taking into consideration the aspect of the asymmetrical vascular uptake on the 3 sets of images. Access to the 3 sets of images together was definitely beneficial to the observers, especially in more difficult cases.

Although 99mTc-apcitide uptake has been described at various degrees in cellulitis or hematoma, these conditions usually can be differentiated from ADVT by the extent, shape, and localization of the uptake. Other possible explanations will have to be evaluated to understand why some cases show more initial uptake, such as the size, localization, and age of the thrombus; the effect of anticoagulant and antiplatelet medication; and other localized hemodynamic parameters.

We must remind readers that 99mTc-apcitide scintigraphy is a novel type of diagnostic imaging procedure now available in clinical nuclear medicine. Therefore, criteria for positive and negative tests must be established and tested against a gold-standard method for ADVT, even an imperfect one such as contrast-enhanced venography. It is likely that the accuracy of 99mTc-apcitide scintigraphy will improve with more extensive clinical experience. However, preliminary results of investigative studies performed with other radiolabeled peptides in the detection of ADVT (2) seem to confirm that changes of uptake or target-to-background ratio over time are important criteria in the diagnosis of ADVT, as demonstrated in our study.

REFERENCES

  1. ↵
    Taillefer R, Thérasse E, Turpin S, et al: Comparison of early and delayed scintigraphy with 99mTc-apcitide and correlation with contrast-enhanced venography in detection of acute deep vein thrombosis. J Nucl Med 1999;40:2029–2035.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    Taillefer R, Lambert R, Boucher L, et al: 99mTc-fibrin binding domain of fibronectin (FBD): a new radiopharmaceutical for detection of acute deep vein thrombosis (preliminary study) [abstract]. J Nucl Med 1999;40.(suppl):11P.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 41, Issue 10
October 1, 2000
  • Table of Contents
  • Table of Contents (PDF)
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
99mTc-Apcitide Scintigraphy and the Detection of Acute Deep Vein Thrombosis
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
99mTc-Apcitide Scintigraphy and the Detection of Acute Deep Vein Thrombosis
Pierre Weinmann, Jean-Luc Moretti
Journal of Nuclear Medicine Oct 2000, 41 (10) 1768-1769;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
99mTc-Apcitide Scintigraphy and the Detection of Acute Deep Vein Thrombosis
Pierre Weinmann, Jean-Luc Moretti
Journal of Nuclear Medicine Oct 2000, 41 (10) 1768-1769;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • REFERENCES
    • REFERENCES
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Recruitment
  • Recruitment
  • Recruitment
Show more Authors of the Letter and the Reply

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire