JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schaefer, W. M.
Right arrow Articles by Kühl, H. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schaefer, W. M.
Right arrow Articles by Kühl, H. P.

Validation of QGS and 4D-MSPECT for Quantification of Left Ventricular Volumes and Ejection Fraction from Gated 18F-FDG PET: Comparison with Cardiac MRI

Wolfgang M. Schaefer, MD, PhD1, Claudia S.A. Lipke, MD2, Bernd Nowak, MD1, Hans-Juergen Kaiser, PhD1, Patrick Reinartz, MD1, Arno Buecker, MD3, Gabriele A. Krombach, MD3, Udalrich Buell, MD1 and Harald P. Kühl, MD2

1 Department of Nuclear Medicine, University Hospital, University of Aachen, Aachen, Germany
2 Medical Clinic I, University Hospital, University of Aachen, Aachen, Germany
3 Department of Radiology, University Hospital, University of Aachen, Aachen, Germany



View larger version (34K):

[in a new window]
 
FIGURE 1. Correlation analysis of EDV estimated with QGS (A) and 4D-MSPECT (C) from gated 18F-FDG PET and cMRI. Bland-Altman plots compare QGS versus cMRI (B) and 4D-MSPECT versus cMRI (D). 4DM = 4D-MSPECT; gFDG-PET and gPET = gated 18F-FDG PET.

 


View larger version (34K):

[in a new window]
 
FIGURE 2. Correlation analysis of ESV estimated with QGS (A) and 4D-MSPECT (C) from gated 18F-FDG PET and cMRI. Bland-Altman plots compare QGS versus cMRI (B) and 4D-MSPECT versus cMRI (D). 4DM = 4D-MSPECT; gFDG-PET and gPET = gated 18F-FDG PET.

 


View larger version (36K):

[in a new window]
 
FIGURE 3. Correlation analysis of LVEF estimated with QGS (A) and 4D-MSPECT (C) from gated 18F-FDG PET and cMRI. Bland-Altman plots compare QGS versus cMRI (B) and 4D-MSPECT versus cMRI (D). 4DM = 4D-MSPECT; gFDG-PET and gPET = gated 18F-FDG PET.

 


View larger version (40K):

[in a new window]
 
FIGURE 4. Correlation analysis of EDV (A), ESV (C), and LVEF (E) estimated with QGS and 4D-MSPECT from gated 18F-FDG PET. Bland-Altman plots compare QGS versus 4D-MSPECT for EDV (B), ESV (D), and LVEF (F). 4DM = 4D-MSPECT; gFDG-PET = gated 18F-FDG PET.

 





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2004 by the Society of Nuclear Medicine.