JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boerman, O. C.
Right arrow Articles by Corstens, F. H.M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boerman, O. C.
Right arrow Articles by Corstens, F. H.M.

A 3-Step Pretargeting Strategy to Image Infection

Otto C. Boerman, Julliette van Eerd, Wim J.G. Oyen and Frans H.M. Corstens

Department of Nuclear Medicine, University Hospital Nijmegen, Nijmegen, The Netherlands



View larger version (27K):

[in a new window]
 
FIGURE 1. Scintigraphic images of rats with S. aureus calf muscle infections. Rats received 0.66 nmol (100 µg) anti-DTPA antibody intravenously. Four hours later, 0.3 nmol (20 µg) BSA-DTPA-In was injected as blocking agent, and 15 min thereafter, rats received 111In-DTPA, 111In-DTPA-Lys, or 111In-diDTPA (8 pmol per rat, 4 MBq per rat). Images were acquired 2 h after injection of radiolabel.

 


View larger version (23K):

[in a new window]
 
FIGURE 2. Scintigraphic images of rats with S. aureus calf muscle infections. Rats received 300 µg (2 nmol) anti-DTPA antibody intravenously. Four hours later, each group of rats received BSA-DTPA-In (0–0.3, 1, and 3) to block anti-DTPA antibody activity in circulation. Fifteen minutes thereafter, rats received 111In-diDTPA (8 pmol per rat, 4 MBq per rat). Images were acquired 2 h after injection of radiolabel.

 


View larger version (25K):

[in a new window]
 
FIGURE 3. Scintigraphic images of rats with S. aureus calf muscle infections. Rats received 300 µg (2 nmol) anti-DTPA antibody intravenously. Four hours later, rats received 1 nmol BSA-DTPA-In as blocking agent. Fifteen minutes thereafter, each group of rats received 111In-diDTPA (1.6, 8, and 40 pmol per rat, respectively; 4 MBq per rat). Images were acquired 2 h after injection of radiolabel.

 


View larger version (31K):

[in a new window]
 
FIGURE 4. Scintigraphic images of rats with S. aureus calf muscle infections. Rats received 300 µg (2 nmol) anti-DTPA antibody intravenously. Rats received 1 nmol BSA-DTPA-In as blocking agent 1, 4, and 24 h later. Fifteen minutes thereafter, each group of rats received 111In-diDTPA (8 pmol per rat, 4 MBq per rat). Images were acquired 2 h after injection of radiolabel.

 


View larger version (35K):

[in a new window]
 
FIGURE 5. Scintigraphic images of rats with S. aureus calf muscle infections. One group of rats was imaged according to optimized 3-step approach (2 nmol anti-DTPA antibody; 4 h later, 1 nmol BSA-DTPA-In; 5 min later, 40 pmol 111In-diDTPA). Other group of rats received 111In-IgG (4 MBq, 0.66 nmol). Both groups of rats were imaged 5 h after first intravenous injection.

 


View larger version (44K):

[in a new window]
 
FIGURE 6. Scintigraphic images of rats with S. aureus calf muscle infections. Both groups received 2 nmol anti-DTPA antibody. Four hours later, anti-DTPA antibody activity in circulation was blocked with 1 nmol BSA-DTPA-In. Five minutes thereafter, one group of rats received 40 pmol 111In-diDTPA (4 MBq), whereas other group received 40 pmol 99mTc-diDTPA (5 MBq). Images were acquired 2 h after injection of radiolabel.

 