JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by van der Weerdt, A. P.
Right arrow Articles by Lammertsma, A. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by van der Weerdt, A. P.
Right arrow Articles by Lammertsma, A. A.

Image-Derived Input Functions for Determination of MRGlu in Cardiac 18F-FDG PET Scans

Arno P. van der Weerdt, Lucas J. Klein, Ronald Boellaard, Cees A. Visser, Frans C. Visser and Adriaan A. Lammertsma

Department of Cardiology and PET Center, Institute for Cardiovascular Research-VU, VU Medical Center, Amsterdam, The Netherlands



View larger version (25K):

[in a new window]
 
FIGURE 1. Example of relationship of peak activity of arterial plasma time–activity curve (AS) and all IDIF (AA, LA, LV, DA) from representative study. ROIs of 15-mm diameter were used.

 


View larger version (33K):

[in a new window]
 
FIGURE 2. Example of time–activity curves from arterial blood sampler (dashed lines) and from both large and small LV and AA ROIs (solid lines). (A) AA; 5-mm ROI. (B) LV; 5-mm ROI. (C) AA; 15-mm ROI. (D) LV; 15-mm ROI. These examples show close relationship of AA time–activity curves with those of blood sampler, overestimation of FDG activity with LV time–activity curves, higher noise levels in time–activity curves from small ROIs, and higher noise levels in time–activity curves from LV compared with those from AA.

 


View larger version (18K):

[in a new window]
 
FIGURE 3. Limits of agreement for compartmental (Comp) and Patlak analysis (n = 17) (23). Mean difference in MRGlu = -0.01, 2 SD = 0.01 µmol/mL/min.

 


View larger version (15K):

[in a new window]
 
FIGURE 4. Ratios of MRGlu obtained with IDIF to MRGlu obtained with arterial input function (Sampler) of all patients. Because of 1 outlier, LV and DA consisted of 17 patients. Rejected ratio for LV was 1.18 and for DA was 0.66. ROIs of 15-mm diameter were used.

 


View larger version (42K):

[in a new window]
 
FIGURE 5. Bland–Altman plot comparing MRGlu obtained with arterial input function and MRGlu obtained with corresponding IDIF (15-mm ROIs). Dotted line represents mean difference in MRGlu; dashed lines represent corresponding value at ±2 SD. (A) AA: mean difference = 0.01, 2 SD = 0.05 µmol/mL/min. (B) LA: mean difference = 0.06, 2 SD = 0.06 µmol/mL/min. (C) LV (n = 17); mean difference = 0.06, 2 SD = 0.07 µmol/mL/min. (D) DA (n = 17): mean difference = 0.00, 2 SD = 0.07 µmol/mL/min.

 


View larger version (40K):

[in a new window]
 
FIGURE 6. Bland–Altman analysis of interobserver variation using 15-mm ROIs. Dotted line represents mean difference in MRGlu; dashed lines represent corresponding value at ±2 SD. (A) AA; mean difference = 0.00, 2 SD = 0.02 µmol/mL/min. (B) LA; mean difference = -0.01, 2 SD = 0.08 µmol/mL/min. (C) LV (n = 17); mean difference = -0.03, 2 SD = 0.08 µmol/mL/min. (D) DA; mean difference = 0.00, 2 SD = 0.04 µmol/mL/min.

 