JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


First published online August 18, 2009, 10.2967/jnumed.108.061333
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplemental Data
Right arrow All Versions of this Article:
jnumed.108.061333v1
50/9/1418    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Xu, Y.
Right arrow Articles by Slomka, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Xu, Y.
Right arrow Articles by Slomka, P. J.
Journal of Nuclear Medicine Vol. 50 No. 9 1418-1426
© 2009 by Society of Nuclear Medicine

doi: 10.2967/jnumed.108.061333

Clinical Investigation

Automated Quality Control for Segmentation of Myocardial Perfusion SPECT

Yuan Xu1, Paul Kavanagh1, Mathews Fish2, James Gerlach1, Amit Ramesh1, Mark Lemley2, Sean Hayes1, Daniel S. Berman1,3, Guido Germano1,3 and Piotr J. Slomka1,3

1 Departments of Imaging and Medicine, Cedars-Sinai Medical Center, Los Angeles, California; 2 Sacred Heart Medical Center, Eugene, Oregon; 3 David Geffen School of Medicine, UCLA, Los Angeles, California

Correspondence: For correspondence or reprints contact: Piotr J. Slomka, Cedars-Sinai Medical Center, 8700 Beverly Blvd., Taper #A047, Los Angeles, CA 90048. E-mail: piotr.slomka{at}cshs.org

Left ventricular (LV) segmentation, including accurate assignment of LV contours, is essential for the quantitative assessment of myocardial perfusion SPECT (MPS). Two major types of segmentation failures are observed in clinical practices: incorrect LV shape determination and incorrect valve-plane (VP) positioning. We have developed a technique to automatically detect these failures for both nongated and gated studies. Methods: A standard Cedars-Sinai perfusion SPECT (quantitative perfusion SPECT [QPS]) algorithm was applied to derive LV contours in 318 consecutive 99mTc-sestamibi rest/stress MPS studies consisting of stress/rest scans with or without attenuation correction and gated stress/rest images (1,903 scans total). Two numeric parameters, shape quality control (SQC) and valve-plane quality control, were derived to categorize the respective contour segmentation failures. The results were compared with the visual classification of automatic contour adequacy by 3 experienced observers. Results: The overall success of automatic LV segmentation in the 1,903 scans ranged from 66% on nongated images (incorrect shape, 8%; incorrect VP, 26%) to 87% on gated images (incorrect shape, 3%; incorrect VP, 10%). The overall interobserver agreement for visual classification of automatic LV segmentation was 61% for nongated scans and 80% for gated images; the agreement between gray-scale and color-scale display for these scans was 86% and 91%, respectively. To improve the reliability of visual evaluation as a reference, the cases with intra- and interobserver discrepancies were excluded, and the remaining 1,277 datasets were considered (101 with incorrect LV shape and 102 with incorrect VP position). For the SQC, the receiver-operating-characteristic area under the curve (ROC-AUC) was 1.0 ± 0.00 for the overall dataset, with an optimal sensitivity of 100% and a specificity of 98%. The ROC-AUC was 1.0 in all specific datasets. The algorithm was also able to detect the VP position errors: VP overshooting with ROC-AUC, 0.91 ± 0.01; sensitivity, 100%; and specificity, 70%; and VP undershooting with ROC-AUC, 0.96 ± 0.01; sensitivity, 100%; and specificity, 70%. Conclusion: A new automated method for quality control of LV MPS contours has been developed and shows high accuracy for the detection of failures in LV segmentation with a variety of acquisition protocols. This technique may lead to an improvement in the objective, automated quantitative analysis of MPS.

Key Words: single photon emission computed tomography • quality control • myocardial perfusion imaging • left ventricle segmentation

COPYRIGHT © 2009 by the Society of Nuclear Medicine, Inc.


Related articles in JNM:

This Month in JNM

JNM 2009 50: 11A-12A. [Full Text]  






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2009 by the Society of Nuclear Medicine.