JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


First published online August 18, 2009, 10.2967/jnumed.109.064428
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
jnumed.109.064428v1
50/9/1401    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Bowen, S. L.
Right arrow Articles by Badawi, R. D.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bowen, S. L.
Right arrow Articles by Badawi, R. D.
Journal of Nuclear Medicine Vol. 50 No. 9 1401-1408
© 2009 by Society of Nuclear Medicine

doi: 10.2967/jnumed.109.064428

Clinical Investigation

Initial Characterization of a Dedicated Breast PET/CT Scanner During Human Imaging

Spencer L. Bowen1, Yibao Wu1, Abhijit J. Chaudhari1, Lin Fu1, Nathan J. Packard2, George W. Burkett2, Kai Yang2, Karen K. Lindfors2, David K. Shelton2, Rosalie Hagge2, Alexander D. Borowsky3, Steve R. Martinez4, Jinyi Qi1, John M. Boone2, Simon R. Cherry1 and Ramsey D. Badawi2

1 Department of Biomedical Engineering, UC Davis, Davis, California; 2 Department of Radiology, UC Davis Medical Center, Sacramento, California; 3 Department of Pathology, UC Davis Medical Center, Sacramento, California; and 4 Division of Surgical Oncology, UC Davis Cancer Center, Sacramento, California

Correspondence: For correspondence or reprints contact: Spencer L. Bowen, Department of Biomedical Engineering, University of California, One Shields Ave., Davis, CA 95616. E-mail: slbowen{at}ucdavis.edu

We have constructed a dedicated breast PET/CT scanner capable of high-resolution functional and anatomic imaging. Here, we present an initial characterization of scanner performance during patient imaging. Methods: The system consisted of a lutetium oxyorthosilicate–based dual–planar head PET camera (crystal size, 3 x 3 x 20 mm) and 768-slice cone-beam CT. The position of the PET heads (separation and height) could be adjusted for varying breast dimensions. For scanning, the patient lay prone on a specialized bed and inserted a single pendent breast through an aperture in the table top. Compression of the breast as used in mammography is not required. PET and CT systems rotate in the coronal plane underneath the patient sequentially to collect fully tomographic datasets. PET images were reconstructed with the fully 3-dimensional maximum a posteriori method, and CT images were reconstructed with the Feldkamp algorithm, then spatially registered and fused for display. Phantom scans were obtained to assess the registration accuracy between PET and CT images and the influence of PET electronics and activity on CT image quality. We imaged 4 women with mammographic findings highly suggestive of breast cancer (breast imaging reporting and data system, category 5) in an ongoing clinical trial. Patients were injected with 18F-FDG and imaged for 12.5 min per breast. From patient data, noise-equivalent counting rates and the singles-to-trues ratio (a surrogate for the randoms fraction) were calculated. Results: The average registration error between PET and CT images was 0.18 mm. PET electronics and activity did not significantly affect CT image quality. For the patient trial, biopsy-confirmed cancers were visualized on dedicated breast PET/CT on all patient scans, including the detection of ductal carcinoma in situ in 1 case. The singles-to-trues ratio was found to be inversely correlated with breast volume in the field of view, suggesting that larger breasts trend toward increased noise-equivalent counting rates for all other things equal. Conclusion: Scanning of the uncompressed breast with dedicated breast PET/CT can accurately visualize suspected lesions in 3 dimensions.

Key Words: breast cancer • PET/CT • positron emission mammography • 18F-FDG • dedicated