JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


First published online January 21, 2009, 10.2967/jnumed.108.056705
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
jnumed.108.056705v1
50/2/316    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Divoli, A.
Right arrow Articles by Bardiès, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Divoli, A.
Right arrow Articles by Bardiès, M.
Journal of Nuclear Medicine Vol. 50 No. 2 316-323
© 2009 by Society of Nuclear Medicine

doi: 10.2967/jnumed.108.056705

Basic Science Investigation

Effect of Patient Morphology on Dosimetric Calculations for Internal Irradiation as Assessed by Comparisons of Monte Carlo Versus Conventional Methodologies

Antigoni Divoli1, Sophie Chiavassa2,3, Ludovic Ferrer2, Jacques Barbet2, Glenn D Flux1 and Manuel Bardiès2

1 Joint Department of Physics, Institute of Cancer Research and the Royal Marsden NHS Foundation Trust, Sutton, United Kingdom; 2 INSERM U892, Nantes, France; and 3 CHD Les Oudairies, La Roche sur Yon, France

Correspondence: For correspondence or reprints contact: Antigoni Divoli, Department of Physics, Royal Marsden Hospital, Downs Rd., SM2 5PT Sutton, Surrey, U.K. E-mail: antigoni.divoli{at}icr.ac.uk

Dosimetric calculations are performed with an increasing frequency before or after treatment in targeted radionuclide therapy, as well as for radiation protection purposes in diagnostic nuclear medicine. According to the MIRD committee formalism, the mean absorbed dose to a target is given by the product of the cumulated activity and a dose-conversion factor, known as the S factor. Standard S factors have been published for mathematic phantoms and for unit-density spheres. The accuracy of the results from the use of these S factors is questionable, because patient morphology can vary significantly. The aim of this work was to investigate differences between patient-specific dosimetric results obtained using Monte Carlo methodology and results obtained using S factors calculated on standard models. Methods: The CT images of 9 patients, who ranged in size, were used. Patient-specific S factors for 131I were calculated with the MCNPX2.5.0 Monte Carlo code using a tool for personalized internal dose assessment, OEDIPE; standard S factors from OLINDA/EXM were compared against the patient-specific S factors. Furthermore, realistic biodistributions and cumulated activities for normal organs and tumors were used, and mean organ- and tumor-absorbed doses calculated with OEDIPE and OLINDA/EXM were compared. Results: The ratio of the standard and the patient-specific S factors were between 0.49 and 1.84 for a target distant from the source for 4 organs and 2 tumors studied as source and targets. For the case of self-irradiation, the equivalent ratio ranged between 0.45 and 2.47 and between 1.00 and 1.06 when mass correction was applied. Differences in mean absorbed doses were as high as 140% when realistic cumulated activity values were used. These values decreased to less than 26% in all cases studied when mass correction was applied to the self-irradiation given by OLINDA/EXM. Conclusion: Standard S factors can yield mean absorbed doses for normal organs or tumors with a reasonable accuracy (26% for the cases studied) as compared with absorbed doses calculated with Monte Carlo, provided that they have been corrected for mass.

Key Words: radionuclide therapy • dosimetry • internal radiation • patient-specific dosimetry

COPYRIGHT © 2009 by the Society of Nuclear Medicine, Inc.


Related articles in JNM:

This Month in JNM

JNM 2009 50: 11A-12A. [Full Text]  






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2009 by the Society of Nuclear Medicine.