Clinical Investigation |
1 Department of Radiology and Diagnostic Imaging, Postgraduate Medical Centre and Central Clinical Hospital of Ministry of Internal Affairs and Administration, Warsaw, Poland; 2 Radioisotope Centre POLATOM, Otwock-Swierk, Poland; 3 Department of Nuclear Medicine, Royal Free Hospital, London, United Kingdom; 4 Department of Pathology, Central Clinical Hospital of Ministry of Internal Affairs and Administration, Warsaw, Poland; 5 Department of Radiology and Diagnostic Imaging, Central Clinical Hospital of Ministry of Internal Affairs and Administration, Warsaw, Poland; and 6 Radiological Chemistry Unit, University Hospital, Basel, Switzerland
Correspondence: For correspondence contact: Jaroslaw B. Cwikla, Department of Radiology and Diagnostic Imaging, Hospital Ministry of Internal Affairs and Administration, 137 Woloska, 02-507 Warsaw, Poland. E-mail: jaroslaw.cwikla{at}cskmswia.pl
The imaging of neuroendocrine tumors has become one of the most significant areas in nuclear oncology. In an attempt to provide high-quality imaging and possible sensitivity at a reduced cost, time, and radiation dose, several 99mTc agents have been proposed. The aim of this initial study was to compare the tumor uptake and biodistribution of 2 new 6-hydrazinopyridine-3-carboxylic acid (HYNIC)–derivatized Tyr3-octreotide analogs, 99mTc-[HYNIC,Tyr3]octreotide (99mTc-TOC) and 99mTc-[HYNIC,Tyr3,Thr8]octreotide (99mTc-TATE), in patients with somatostatin receptor–expressing tumors. Methods: Each of 12 patients with proven gastrointestinal pancreatic neuroendocrine tumors received a mean activity of 520 MBq of 99mTc-TOC and 99mTc-TATE. Scintigraphy with both tracers was performed 3–4 h after their injection using standard whole-body and SPECT imaging. The images were reviewed subjectively by 2 readers, who reported tumor uptake lesion by lesion. Results: Both radiotracers demonstrated concordance between the results in 7 patients (58%). In total, 110 sites of disease were identified with 99mTc-TOC, compared with 115 with 99mTc-TATE. There was 1 case in which 99mTc-TOC identified sites of disease not seen on 99mTc-TATE imaging but 4 cases in which some sites of disease were seen with 99mTc-TATE and not 99mTc-TOC. Conclusion: In this initial study, both tracers seem to show similar sites of tumor, with 99mTc-TATE having a slight edge in the total number of lesions seen, especially in lymph node metastases.
Key Words: 99mTc-TOC 99mTc-TATE somatostatin receptor scintigraphy GEP NET
COPYRIGHT © 2008 by the Society of Nuclear Medicine, Inc.
Related articles in JNM:
This article has been cited by other articles:
![]() |
J. B. Cwikla, A. Sankowski, N. Seklecka, J. R. Buscombe, A. Nasierowska-Guttmejer, K. G. Jeziorski, R. Mikolajczak, D. Pawlak, K. Stepien, and J. Walecki Efficacy of radionuclide treatment DOTATATE Y-90 in patients with progressive metastatic gastroenteropancreatic neuroendocrine carcinomas (GEP-NETs): a phase II study Ann. Onc., October 15, 2009; (2009) mdp372v1. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | RSS | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |