JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


First published online June 13, 2008, 10.2967/jnumed.107.049858
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
jnumed.107.049858v1
49/7/1047    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Nahmias, C.
Right arrow Articles by Townsend, D.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nahmias, C.
Right arrow Articles by Townsend, D.
Journal of Nuclear Medicine Vol. 49 No. 7 1047-1052
© 2008 by Society of Nuclear Medicine

doi: 10.2967/jnumed.107.049858

Clinical Investigation

Does Reducing CT Artifacts from Dental Implants Influence the PET Interpretation in PET/CT Studies of Oral Cancer and Head and Neck Cancer?

Claude Nahmias1, Catherine Lemmens2, David Faul3, Eric Carlson4, Misty Long1, Todd Blodgett5, Johan Nuyts2 and David Townsend1

1 Molecular Imaging and Translational Research Program, University of Tennessee, Knoxville, Tennessee; 2 Department of Nuclear Medicine, University Hospital Gasthuisberg and Katholieke Universiteit Leuven, Leuven, Belgium; 3 Siemens Medical Solutions, Knoxville, Tennessee; 4 Department of Oral and Maxillofacial Surgery, University of Tennessee Medical Center, Knoxville, Tennessee; and 5 Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania

Correspondence: For correspondence or reprints contact: Claude Nahmias, Molecular Imaging and Translational Research Program, Graduate School of Medicine, University of Tennessee, 1924 Alcoa Highway, Knoxville, TN 37920-6999. E-mail: cnahmias{at}utmck.edu

In patients with oral head and neck cancer, the presence of metallic dental implants produces streak artifacts in the CT images. These artifacts negate the utility of CT for the spatial localization of PET findings and may propagate through the CT-based attenuation correction into the PET images. In this study, we evaluated the efficacy of an algorithm that reduces metallic artifacts in CT images and the impact of this approach on the quantification of PET images. Methods: Fifty-one patients with and 9 without dental implants underwent a PET/CT study. CT images through the patient's dental implants were reconstructed using both standard CT reconstruction and an algorithm that reduces metallic artifacts. Attenuation correction factors were calculated from both sets of CT images and applied to the PET data. The CT images were evaluated for any reduction of the artifacts. The PET images were assessed for any quantitative change introduced by metallic artifact reduction. Results: For each reconstruction, 2 regions of interest were defined in areas where the standard CT reconstruction overestimated the Hounsfield units (HU), 2 were defined in underestimated areas, and 1 was defined in a region unaffected by the artifacts. The 5 regions of interest were transferred to the other 3 reconstructions. Mean HU or mean Bq/cm3 were obtained for all regions. In the CT reconstructions, metallic artifact reduction decreased the overestimated HUs by approximately 60% and increased the underestimated HUs by approximately 90%. There was no change in quantification in the PET images between the 2 algorithms (Spearman coefficient of rank correlation, 0.99). Although the distribution of attenuation (HU) changed considerably in the CT images, the distribution of activity did not change in the PET images. Conclusion: Our study demonstrated that the algorithm can enhance the structural and spatial content of CT images in the presence of metallic artifacts. The CT artifacts do not propagate through the CT-based attenuation correction into the PET images, confirming the robustness of CT-based attenuation correction in the presence of metallic artifacts. The study also demonstrated that considerable changes in CT images do not change the PET images.

Key Words: PET/CT • attenuation correction • metallic artifacts • oral head and neck cancer