JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


First published online March 14, 2008, 10.2967/jnumed.107.044727
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
jnumed.107.044727v1
49/4/630    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Huisman, M. C.
Right arrow Articles by Schwaiger, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Huisman, M. C.
Right arrow Articles by Schwaiger, M.
Journal of Nuclear Medicine Vol. 49 No. 4 630-636
© 2008 by Society of Nuclear Medicine

doi: 10.2967/jnumed.107.044727

Basic Science Investigation

Initial Characterization of an 18F-Labeled Myocardial Perfusion Tracer

Marc C. Huisman1, Takahiro Higuchi1, Sybille Reder1, Stephan G. Nekolla1, Thorsten Poethko1, Hans-Jürgen Wester1, Sibylle I. Ziegler1, David S. Casebier2, Simon P. Robinson2 and Markus Schwaiger1

1 Department of Nuclear Medicine, Klinikum Rechts der Isar, Technische Universität München, Munich, Germany; and 2 Department of Discovery Chemistry and Department of Discovery Biology, Bristol Myers Squibb Medical Imaging, North Billerica, Massachusetts

Correspondence: For correspondence contact: Markus Schwaiger, MD, Nuklearmedizinische Klinik der Technischen Universität München, Ismaninger Strasse 22, 81675 Munich, Germany. E-mail: markus.schwaiger{at}tum.de

PET allows for quantitative, regional myocardial perfusion imaging. The short half-lives of the perfusion tracers currently in use limit their clinical applicability. Here, the biodistribution and imaging quality of a new 18F-labeled myocardial perfusion agent (18F-BMS-747158-02) in an animal model are described. Methods: The biodistribution of 18F-BMS-747158-02 was determined at 10 and 60 min after injection. The first-pass extraction fraction of the tracer was measured in isolated rat hearts perfused with the Langendorff method. Small-animal PET imaging was used to study tracer retention. Results: The biodistribution at 10 min after injection demonstrated high myocardial uptake (3.1 percentage injected dose per gram [%ID/g]) accompanied by little activity in the lungs (0.3 %ID/g) and liver (1.0 %ID/g). The tracer showed a high and flow-independent myocardial first-pass extraction fraction, averaging 0.94 (SD = 0.04). PET imaging provided excellent delineation of myocardial structures. The heart-to-lung activity ratio increased from 4.7 to 10.2 between 1 and 15 min after tracer injection (at rest). Adenosine infusion (140 µg/kg/min) led to a significant increase in myocardial tracer retention (from 1.68 [SD = 0.23]) s–1 to 3.21 [SD = 0.92] s–1; P = 0.03). Conclusion: The observation of a high and flow-independent first-pass extraction fraction promises linearity between tracer uptake and myocardial blood flow. Sustained myocardial tracer uptake, combined with high image contrast, will allow for imaging protocols with tracer injection at peak exercise followed by delayed imaging. Thus, 18F-BMS-747158-02 is a promising new tracer for the quantitative imaging of myocardial perfusion and can be distributed to imaging laboratories without a cyclotron.

Key Words: PET • myocardial perfusion • imaging

COPYRIGHT © 2008 by the Society of Nuclear Medicine, Inc.


Related articles in JNM:

This Month in JNM

JNM 2008 49: 11A-12A. [Full Text]  



This article has been cited by other articles:


Home page
JNMHome page
T. Higuchi, S. G. Nekolla, M. M. Huisman, S. Reder, T. Poethko, M. Yu, H.-J. Wester, D. S. Casebier, S. P. Robinson, R. M. Botnar, et al.
A New 18F-Labeled Myocardial PET Tracer: Myocardial Uptake After Permanent and Transient Coronary Occlusion in Rats
J. Nucl. Med., October 1, 2008; 49(10): 1715 - 1722.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2008 by the Society of Nuclear Medicine.