JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


First published online February 20, 2008, 10.2967/jnumed.107.047233
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
jnumed.107.047233v1
49/3/347    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Virta, J. R.
Right arrow Articles by Rinne, J. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Virta, J. R.
Right arrow Articles by Rinne, J. O.
Journal of Nuclear Medicine Vol. 49 No. 3 347-353
© 2008 by Society of Nuclear Medicine

doi: 10.2967/jnumed.107.047233

Clinical Investigation

1-11C-Methyl-4-Piperidinyl-N-Butyrate Radiation Dosimetry in Humans by Dynamic Organ-Specific Evaluation

Jere R. Virta1, Tuula Tolvanen1, Kjell Någren2, Anna Brück1, Anne Roivainen1 and Juha O. Rinne1

1 Turku University Hospital, Turku PET Centre, Turku, Finland; and 2 Radiopharmaceutical Chemistry Laboratory, Turku PET Centre, Turku, Finland

Correspondence: For correspondence or reprints contact: Jere R. Virta, MD, Turku PET Centre, P.O. Box 52, FIN-20521, Turku, Finland. E-mail: jere.virta{at}utu.fi

Deficits of cholinergic neurotransmission contribute to various neurologic and psychiatric conditions. The neurotransmitter acetylcholine is hydrolyzed in the synaptic clefts by 2 enzymes, acetylcholinesterase (AChE) and butyrylcholinesterase (BuChE). 1-[11C]-Methyl-4-piperidinyl-N-butyrate (11C-MP4B) is a radioligand for the assessment study of BuChE activity in human brain with PET. In the present study the radiation-absorbed doses of the 11C-MP4B were estimated in humans according to the guidelines of the International Commission on Radiological Protection. Two different data acquisition protocols—dynamic organ-specific evaluation (DOSE) and whole-body scanning—were compared. Both methods are widely used for evaluation of radiation burden of 11C-labeled PET tracers. Methods: Fixed-bed PET on the upper neck, thorax, abdomen, or pelvic region was performed on 7 healthy subjects after injection of 707 ± 34 MBq (mean ± SD) of 11C-MP4B. Brain input was derived from our previous studies on 18 healthy control subjects and 10 patients with Alzheimer's disease. Regions of interest were drawn on transverse images of all visible organs. Radiation dose estimates were calculated from organ residence times using the MIRDOSE3 software. Urine samples were collected after imaging to estimate tracer extraction. To compare the estimates for absorbed doses between the whole-body scan approach and the DOSE method, we simulated whole-body data acquisition methods used in 11C dosimetry studies with our fixed-bed data. Results: The organs with the highest radiation-absorbed doses were the liver, urinary bladder, kidneys (renal cortex), upper large intestine, trabecular bone, salivary glands, and heart wall. Up to 60% of the injected dose was excreted via the urinary pathway, and the clearance was relatively rapid, as 30% of the radioactivity was excreted within 60 min after injection. With a 2-h voiding interval the effective dose was 4.2 µSv/MBq. Conclusion: 11C-MP4B causes less radiation burden than previously studied 11C-labeled PET tracers. No intolerably high absorbed doses were observed in critical organs. With 740 MBq of injected radioactivity, the radiation burden is equivalent to 3.11 mSv. This would allow multiple PET examinations per year to be performed on the same subject. The DOSE method and the simulated whole-body imaging approach produced similar results.

Key Words: butyrylcholinesterase • dosimetry • PET

COPYRIGHT © 2008 by the Society of Nuclear Medicine, Inc.


Related articles in JNM:

This Month in JNM

JNM 2008 49: 11A-12A. [Full Text]  






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2008 by the Society of Nuclear Medicine.