JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brown, A. K.
Right arrow Articles by Innis, R. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brown, A. K.
Right arrow Articles by Innis, R. B.
Journal of Nuclear Medicine Vol. 49 No. 12 2042-2048
© 2008 by Society of Nuclear Medicine

doi: 10.2967/jnumed.108.056291

Basic Science Investigation

Metabotropic Glutamate Subtype 5 Receptors Are Quantified in the Human Brain with a Novel Radioligand for PET

Amira K. Brown, Yasuyuki Kimura, Sami S. Zoghbi, Fabrice G. Siméon, Jeih-San Liow, William C. Kreisl, Andrew Taku, Masahiro Fujita, Victor W. Pike and Robert B. Innis

Molecular Imaging Branch, National Institute of Mental Health, Bethesda, Maryland

Correspondence: For correspondence or reprints contact: Robert B. Innis, Molecular Imaging Branch, National Institute of Mental Health, 31 Center Dr., Room B2/B37 Bethesda, MD 20892-2035. E-mail: robert.innis{at}nih.gov

We developed a radioligand, 3-fluoro-5-(2-(2-18F-(fluoromethyl)thiazol-4-yl)ethynyl)benzonitrile (18F-SP203), for metabotropic glutamate subtype 5 (mGluR5) receptors that showed both promising (high specific binding) and problematic (defluorination) imaging characteristics in animals. The purposes of this initial evaluation in human subjects were to determine whether 18F-SP203 is defluorinated in vivo (as measured by uptake of radioactivity in the skull) and to determine whether the uptake in the brain can be quantified as distribution volume relative to concentrations of 18F-SP203 in plasma. Methods: Seven healthy subjects were injected with 18F-SP203 (323 ± 87 MBq) and scanned over 5 h, with rest periods outside the camera. The concentrations of 18F-SP203, separated from radiometabolites, were measured in arterial plasma. Results: The skull was difficult to visualize on PET images in the initial 2 h, because of high radioactivity in the brain. Although radioactivity in the skull and adjacent cortex showed some cross-contamination, the concentration of radioactivity in the skull was less than half of that in the adjacent cortex during the initial 2 h. Modeling of regional brain and plasma data showed that a 2-tissue-compartment model was superior to a 1-tissue-compartment model, consistent with measurable amounts of both receptor-specific and nonspecific binding. The concentrations of activity in the brain measured with PET were consistently greater than the modeled values at late but not early time points and may well have been caused by the slow accumulation of radiometabolites in the brain. To determine an adequate time for more accurate measurement of distribution volume, we selected a scan duration (i.e., 2 h) associated with maximal or near-maximal identifiability. Distribution volume was well identified (~2%) by only 2 h (and even just 1) of image acquisition. Conclusion: This initial evaluation of 18F-SP203 in healthy human subjects showed that defluorination is relatively small and that brain uptake can be robustly calculated as distribution volume. The values of distribution volume were well identified and had relatively small variation in this group of 7 subjects. These results suggest that 18F-SP203 will have good sensitivity to measure mGluR5 receptors for both within-subject studies (e.g., receptor occupancy) and between-subject studies (e.g., patients vs. healthy subjects).

Key Words: molecular imaging • glutamate neurotransmission • PET

COPYRIGHT © 2008 by the Society of Nuclear Medicine, Inc.


Related articles in JNM:

This Month in JNM

JNM 2008 49: 11A-12A. [Full Text]  



This article has been cited by other articles:


Home page
J. Pharmacol. Exp. Ther.Home page
H. U. Shetty, S. S. Zoghbi, F. G. Simeon, J.-S. Liow, A. K. Brown, P. Kannan, R. B. Innis, and V. W. Pike
Radiodefluorination of 3-Fluoro-5-(2-(2-[18F](fluoromethyl)-thiazol-4-yl)ethynyl)benzonitrile ([18F]SP203), a Radioligand for Imaging Brain Metabotropic Glutamate Subtype-5 Receptors with Positron Emission Tomography, Occurs by Glutathionylation in Rat Brain
J. Pharmacol. Exp. Ther., December 1, 2008; 327(3): 727 - 735.