JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meirelles, G. S.P.
Right arrow Articles by Schöder, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meirelles, G. S.P.
Right arrow Articles by Schöder, H.
Journal of Nuclear Medicine Vol. 48 No. 5 712-719
© 2007 by Society of Nuclear Medicine

doi: 10.2967/jnumed.106.038034

Clinical Investigation

Deep-Inspiration Breath-Hold PET/CT: Clinical Findings with a New Technique for Detection and Characterization of Thoracic Lesions

Gustavo S.P. Meirelles1, Yusuf Emre Erdi2, Sadek A. Nehmeh2, Olivia D. Squire1, Steven M. Larson1, John L. Humm2 and Heiko Schöder1

1 Department of Radiology, Nuclear Medicine Service, Memorial Sloan-Kettering Cancer Center, New York, New York; and 2 Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York

Correspondence: For correspondence or reprints contact: Heiko Schöder, MD, Department of Radiology/Nuclear Medicine, Memorial Sloan-Kettering Cancer Center, 1275 York Ave., Box 77, New York, NY 10021. E-mail: schoderh{at}mskcc.org

Respiratory motion during PET/CT acquisition can cause misregistration and inaccuracies in calculation of standardized uptake values (SUVs). Our aim was to compare the detection and characterization of thoracic lesions on PET/CT with and without a deep-inspiration protocol. Methods: We studied 15 patients with suspected pulmonary lesions who underwent clinical PET/CT, followed by deep-inspiration breath-hold (BH) PET/CT. In BH CT, the whole chest of the patient was scanned in 15 s at the end of deep inspiration. For BH PET, patients were asked to hold their breath 9 times for 20-s intervals. One radiologist reviewed images, aiming to detect and characterize pulmonary, nodal, and skeletal abnormalities. Clinical CT and BH CT were compared for number, size, and location of lesions. Lesion SUVs were compared between clinical PET and BH PET. Images were also visually assessed for accuracy of fusion and registration. Results: All patients had lesions on clinical CT and BH CT. Pulmonary BH CT detected more lesions than clinical CT in 13 of 15 patients (86.7%). The total number of lung lesions detected increased from 53 with clinical CT to 82 with BH CT (P < 0.001). Eleven patients showed a total of 31 lesions with abnormal 18F-FDG uptake. BH PET/CT had the advantage of reducing misregistration and permitted a better localization of sites with 18F-FDG uptake. A higher SUV was noted in 22 of 31 lesions on BH PET compared with clinical PET, with an average increase in SUV of 14%. Conclusion: BH PET/CT enabled an increased detection and better characterization of thoracic lesions compared with a standard PET/CT protocol, in addition to more precise localization and quantification of the findings. The technique is easy to implement in clinical practice and requires only a minor increase in the examination time.

Key Words: PET/CT • breath-hold • imaging • 18F-FDG • cancer


Related articles in JNM:

This Month in JNM

JNM 2007 48: 11a-12a. [Full Text]  



This article has been cited by other articles:


Home page
JNMHome page
G. Chang, T. Chang, T. Pan, J. W. Clark Jr., and O. R. Mawlawi
Implementation of an Automated Respiratory Amplitude Gating Technique for PET/CT: Clinical Evaluation
J. Nucl. Med., January 1, 2010; 51(1): 16 - 24.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
T. Torizuka, Y. Tanizaki, T. Kanno, M. Futatsubashi, E. Yoshikawa, H. Okada, and Y. Ouchi
Single 20-Second Acquisition of Deep-Inspiration Breath-Hold PET/CT: Clinical Feasibility for Lung Cancer
J. Nucl. Med., October 1, 2009; 50(10): 1579 - 1584.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
E. C. Ford, J. Herman, E. Yorke, and R. L. Wahl
18F-FDG PET/CT for Image-Guided and Intensity-Modulated Radiotherapy
J. Nucl. Med., October 1, 2009; 50(10): 1655 - 1665.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
T. Kawano, E. Ohtake, and T. Inoue
Deep-Inspiration Breath-Hold PET/CT of Lung Cancer: Maximum Standardized Uptake Value Analysis of 108 Patients
J. Nucl. Med., August 1, 2008; 49(8): 1223 - 1231.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Ohno, H. Koyama, Y. Onishi, D. Takenaka, M. Nogami, T. Yoshikawa, S. Matsumoto, Y. Kotani, and K. Sugimura
Non-Small Cell Lung Cancer: Whole-Body MR Examination for M-Stage Assessment--Utility for Whole-Body Diffusion-weighted Imaging Compared with Integrated FDG PET/CT
Radiology, August 1, 2008; 248(2): 643 - 654.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
D. W. Townsend
Dual-Modality Imaging: Combining Anatomy and Function
J. Nucl. Med., June 1, 2008; 49(6): 938 - 955.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2007 by the Society of Nuclear Medicine.