Basic Science Investigation |
1 Department of Radiology and the Bio-X Program, Stanford University School of Medicine, Stanford, California; and 2 Department of Bioengineering, Stanford University, Stanford, California
Correspondence: For correspondence contact: Sanjiv S. Gambhir, MD, PhD, The James H. Clark Center, 318 Campus Dr., East Wing, 1st Floor, Stanford, CA 94305-5427. E-mail: sgambhir{at}stanford.edu
18F-FDG has been used to image mouse xenograft models with small-animal PET for therapy response. However, the reproducibility of serial scans has not been determined. The purpose of this study was to determine the reproducibility of 18F-FDG small-animal PET studies. Methods: Mouse tumor xenografts were formed with B16F10 murine melanoma cells. A 7-min small-animal PET scan was performed 1 h after a 3.7- to 7.4-MBq 18F-FDG injection via the tail vein. A second small-animal PET scan was performed 6 h later after reinjection of 18F-FDG. Twenty-five sets of studies were performed. Mean injected dose per gram (%ID/g) values were calculated from tumor regions of interest. The coefficient of variation (COV) from studies performed on the same day was calculated to determine the reproducibility. Activity from the second scans performed after 6 h were adjusted by subtracting the estimated residual activity from the first 18F-FDG injection. For 7 datasets, an additional scan immediately before the second injection was performed, and residual activity from this additional delayed scan was subtracted from the activity of the second injection. COVs of both subtraction methods were compared. Blood glucose values were measured at the time of injection and used to correct the %ID/g values. Results: The COV for the mean %ID/g between 18F-FDG small-animal PET scans performed on the same day 6 h apart was 15.4% ± 12.6%. The delayed scan subtraction method did not produce any significant change in the COV. Blood glucose correction increased the COV. The injected dose, tumor size, and body weight did not appear to contribute to the variability of the scans. Conclusion: 18F-FDG small-animal PET mouse xenograft studies were reproducible with moderately low variability. Therefore, serial small-animal PET studies may be performed with reasonable accuracy to measure tumor response to therapy.
Key Words: 18F-FDG small-animal PET reproducibility tumor xenograft drug development
* Contributed equally to this work.
This article has been cited by other articles:
![]() |
J. R. Tseng, K. W. Kang, M. Dandekar, S. Yaghoubi, J. H. Lee, J. G. Christensen, S. Muir, P. W. Vincent, N. R. Michaud, and S. S. Gambhir Preclinical Efficacy of the c-Met Inhibitor CE-355621 in a U87 MG Mouse Xenograft Model Evaluated by 18F-FDG Small-Animal PET J. Nucl. Med., January 1, 2008; 49(1): 129 - 134. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |