|
|
|||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Clinical Investigation |
1 Department of Nuclear Medicine and Molecular Imaging Center, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taipei, Taiwan; 2 Department of Radiation Oncology, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taipei, Taiwan; 3 Department of Diagnostic Radiology, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taipei, Taiwan; 4 Division of Hematology/Oncology, Department of Internal Medicine, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taipei, Taiwan; and 5 Department of Otorhinolaryngology, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taipei, Taiwan
Correspondence: For correspondence or reprints contact: Tzu-Chen Yen, MD, PhD, Department of Nuclear Medicine and Molecular Imaging Center, Chang Gung Memorial Hospital, 199 Dunhua N. Rd., Taipei 10507, Taiwan. E-mail: yen1110{at}adm.cgmh.org.tw.
Conventional work-up (CWU) with chest radiography, abdominal ultrasonography, and skeletal scintigraphy has limited value in M staging of nonkeratinizing nasopharyngeal carcinoma (NPC). Our aim was to evaluate whether 18F-FDG PET could replace CWU by comparing their diagnostic efficacies. Methods: Patients with histologically proven nonkeratinizing NPC and no prior treatment were prospectively enrolled. All study participants underwent CWU and 18F-FDG PET for primary M staging. Distant metastasis was considered to be present if there was any reliable evidence identified within 1 y after diagnosis. The comparative diagnostic efficacies of 18F-FDG PET, CWU, and the combination of 18F-FDG PET and CWU (PET+CWU) were evaluated using the areas under the receiver-operating-characteristic (ROC) curves. Results: Sixty-one (20.3%) of 300 eligible patients were found to have distant metastases. On a patient-based analysis, 18F-FDG PET was found to be more effective than CWU (P < 0.001), whereas it was equally effective with PET+CWU (P = 0.130). On region-based analyses, 18F-FDG PET was more effective than skeletal scintigraphy and chest radiography for detecting bone metastases (P < 0.001) and chest metastases (P < 0.001), respectively. 18F-FDG PET and abdominal ultrasound were equally effective for detecting hepatic metastases (P = 0.127). On region-based analyses, the combination of 18F-FDG PET and CWU did not yield any noticeable increase in diagnostic efficacy. Conclusion: 18F-FDG PET can replace CWU in primary M staging of nonkeratinizing NPC.
Key Words: 18F-FDG PET nasopharyngeal carcinoma staging distant metastasis
COPYRIGHT © 2007 by the Society of Nuclear Medicine, Inc.
Related articles in JNM:
This article has been cited by other articles:
![]() |
E. P. Hui, B. B. Ma, S. F. Leung, A. D. King, F. Mo, M. K. Kam, B. K. Yu, S. K. Chiu, W. H. Kwan, R. Ho, et al. Randomized Phase II Trial of Concurrent Cisplatin-Radiotherapy With or Without Neoadjuvant Docetaxel and Cisplatin in Advanced Nasopharyngeal Carcinoma J. Clin. Oncol., January 10, 2009; 27(2): 242 - 249. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | RSS | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |