JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kaufmann, P. A.
Right arrow Articles by Jenni, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kaufmann, P. A.
Right arrow Articles by Jenni, R.
Journal of Nuclear Medicine Vol. 46 No. 8 1272-1277
© 2005 by Society of Nuclear Medicine


Clinical Investigations

Novel Doppler Assessment of Intracoronary Volumetric Flow Reserve: Validation Against PET in Patients With or Without Flow-Dependent Vasodilation

Philipp A. Kaufmann, MD1, Mehdi Namdar, MD1, Felix Matthew, MD2, Marco Roffi, MD3, Schlomo V. Aschkenasy, MD2, Bernd van der Loo, MD2, Gabor Sutsch, MD3, Thomas F. Lüscher, MD3 and Rolf Jenni, MD, MSEE2

1 Nuclear Cardiology, Cardiovascular Center, University Hospital, Zurich, Switzerland
2 Echocardiography, Cardiovascular Center, University Hospital, Zurich, Switzerland
3 Invasive Cardiology, Cardiovascular Center, University Hospital, Zurich, Switzerland

Volumetric blood flow (Q) determination requires simultaneous assessment of mean blood flow velocity and vessel cross-sectional area. At present, no method provides both values. Intracoronary Doppler-based assessment of coronary flow velocity reserve (CFVR) relies on average peak velocity (APV). Because this does not account for changes in velocity profile or vessel area usually occurring with flow-dependent vasodilation, results can be misleading. The aim of this clinical study was to validate against the current gold standard (measurement of myocardial perfusion reserve [MPR] by PET) a new, Doppler-based method for calculating coronary Q and coronary flow reserve (CFR). Methods: Doppler-based intracoronary Q was measured with a proprietary guidewire device in a nonstenotic coronary artery at baseline and during adenosine-induced hyperemic flow (140 µg/kg/min intravenously during 7 min). Three gate positions were assessed, of which 2 were lying within the vessel and 1 was intersecting the vessel. The zeroth (M0) and the first (M1) Doppler moments of the intersecting gate were used to calculate mean blood flow velocity (M1/M0) and vessel area (M0), and M0 of the 2 proximal gates was used to correct for scattering and attenuation. CFR was calculated as hyperemic/resting flow with Q and compared with APV-derived CFVR and with the corresponding segmental MPR obtained with 15O-labeled water and PET. Results: Q (CFR, 2.60 ± 1.07) correlated well with PET (MPR, 2.58 ± 1.11) (r = 0.832, P < 0.005; Bland–Altman limits, –1.42 to 1.09), whereas CFVR did not (r = 0.09, P = not statistically significant; Bland–Altman limits, –3.36 to 2.24). However, in vessels without dilation, there was no difference between CFR, CFVR, and MPR. Conclusion: This procedure for intracoronary Q measurement using the proprietary Doppler guidewire system, which accounts for both changes in flow profile and changes in vessel area, allows invasive, accurate assessment of CFR even in the presence of flow-dependent vasodilation.

Key Words: myocardial blood flow • coronary flow reserve • intracoronary Doppler guidewire • PET


Related articles in JNM:

THIS MONTH IN JNM

JNM 2005 46: 8a-9a. [Full Text]  



This article has been cited by other articles:


Home page
JNMHome page
P. T. Siegrist, O. Gaemperli, P. Koepfli, T. Schepis, M. Namdar, I. Valenta, F. Aiello, S. Fleischmann, H. Alkadhi, and P. A. Kaufmann
Repeatability of Cold Pressor Test-Induced Flow Increase Assessed with H215O and PET
J. Nucl. Med., September 1, 2006; 47(9): 1420 - 1426.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2005 by the Society of Nuclear Medicine.