JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yagle, K. J.
Right arrow Articles by Krohn, K. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yagle, K. J.
Right arrow Articles by Krohn, K. A.
Journal of Nuclear Medicine Vol. 46 No. 4 658-666
© 2005 by Society of Nuclear Medicine


Basic Science Investigations

Evaluation of 18F-Annexin V as a PET Imaging Agent in an Animal Model of Apoptosis

Kevin J. Yagle, PhD1, Janet F. Eary, MD1, Jonathan F. Tait, MD, PhD2, John R. Grierson, PhD1, Jeanne M. Link, PhD1, Barbara Lewellen, CNMT1, Don F. Gibson, BS2 and Kenneth A. Krohn, PhD1

1 Department of Radiology, University of Washington, Seattle, Washington
2 Department of Laboratory Medicine, University of Washington, Seattle, Washington

Annexin V is a 36-kDa protein that binds with high affinity to phosphatidylserine lipids in the cell membrane. Because one of the earliest measurable events in apoptosis is the eversion of phosphatidylserine from the inner membrane leaflet to the outer cell surface, annexin V has proven useful for detecting the earliest stages of apoptosis. Methods: Annexin V was radiolabeled with 18F using N-succinimidyl-4-18F-fluorobenzoic acid chemistry, to a specific activity of 555–925 kBq/µg of protein. 18F-Annexin V (14.8–51.8 MBq) was administered intravenously to rats after pretreatment with cycloheximide (5 mg/kg) to induce liver apoptosis, and the injected rats were imaged by PET over 2 h. After imaging, rats were dissected and individual organs were weighed and counted. Results: Pretreatment of rats with cycloheximide resulted in a 3- to 9-fold increase in uptake of 18F-annexin V in the liver of treated animals at 2 h, compared with controls. By morphologic analysis, treated livers showed a 3- to 6-fold higher level of apoptosis than controls, with higher levels also seen with longer exposure to cycloheximide. Terminal deoxynucleotide end-labeling (TUNEL) assays performed on liver slices showed that cycloheximide induced a 5- to 8-fold increase in the number of TUNEL-positive nuclei. These TUNEL results correlated with the uptake of 18F-annexin V in dissected liver tissue, with an r2 value of 0.89. Biodistribution analysis of normal rats showed highest uptake of 18F-annexin V in the kidneys and urinary bladder, indicating rapid renal clearance of 18F-annexin V metabolites. Conclusion: The PET data, the organ-specific uptake data from dissection, and the morphologic and TUNEL measures of apoptosis together indicate that 18F-annexin V binds specifically to apoptotic tissues in this model of chemically induced apoptosis in rat liver. The short physical half-life of 18F-annexin V and the rapid clearance of its metabolites to the urinary system suggest that 18F-annexin V will be useful in early assessment of the clinical response to cancer therapy in individual patients.

Key Words: molecular imaging • oncology • PET • annexin • apoptosis


Related articles in JNM:

THIS MONTH IN JNM

JNM 2005 46: 8a-9a. [Full Text]  



This article has been cited by other articles:


Home page
The OncologistHome page
D. S. Boss, R. V. Olmos, M. Sinaasappel, J. H. Beijnen, and J. H. M. Schellens
Application of PET/CT in the Development of Novel Anticancer Drugs
Oncologist, January 1, 2008; 13(1): 25 - 38.
[Abstract] [Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
D. A. Mankoff, J. F. Eary, J. M. Link, M. Muzi, J. G. Rajendran, A. M. Spence, and K. A. Krohn
Tumor-Specific Positron Emission Tomography Imaging in Patients: [18F] Fluorodeoxyglucose and Beyond
Clin. Cancer Res., June 15, 2007; 13(12): 3460 - 3469.
[Abstract] [Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
H. M. Linden, K. A. Krohn, R. B. Livingston, and D. A. Mankoff
Monitoring targeted therapy: is fluorodeoxylucose uptake a marker of early response?
Clin. Cancer Res., October 1, 2006; 12(19): 5608 - 5610.
[Full Text] [PDF]


Home page
JCOHome page
W. A. Weber
Positron Emission Tomography As an Imaging Biomarker
J. Clin. Oncol., July 10, 2006; 24(20): 3282 - 3292.
[Abstract] [Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
G. J. Kelloff, K. A. Krohn, S. M. Larson, R. Weissleder, D. A. Mankoff, J. M. Hoffman, J. M. Link, K. Z. Guyton, W. C. Eckelman, H. I. Scher, et al.
The Progress and Promise of Molecular Imaging Probes in Oncologic Drug Development
Clin. Cancer Res., November 15, 2005; 11(22): 7967 - 7985.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2005 by the Society of Nuclear Medicine.