JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jaskowiak, C. J.
Right arrow Articles by Fine, J. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jaskowiak, C. J.
Right arrow Articles by Fine, J. P.
Journal of Nuclear Medicine Vol. 46 No. 3 424-428
© 2005 by Society of Nuclear Medicine


Clinical Investigations

Influence of Reconstruction Iterations on 18F-FDG PET/CT Standardized Uptake Values

Chris J. Jaskowiak, BS1, Jesus A. Bianco, MD1, Scott B. Perlman, MD1 and Jason P. Fine, PhD2

1 Nuclear Medicine Section, Department of Radiology, University of Wisconsin Medical School, Madison, Wisconsin
2 Department of Biostatistics, University of Wisconsin Medical School, Madison, Wisconsin

The goal of this study was to evaluate the effect on the average standardized uptake value (avgSUV) and maximum standardized uptake value (maxSUV) of changing the number of iterations in the reconstruction process on studies acquired with PET/CT. Methods: Data from 50 human tumors were acquired on a PET/CT scanner, using the CT portion for attenuation correction. Reconstruction was performed using the 2-dimensional reconstruction method of ordered-subsets expectation maximization (OSEM) with 28 subsets and with 1, 2, 3, 4, 5, 10, 20, and 40 iterations. The standardized uptake value (SUV) of the studies was analyzed by positioning a region of interest tightly around the tumor and reproducing the same area on all same-study iterations for SUV measurements. Results: The differences in mean avgSUV and mean maxSUV were statistically different across different iteration groups. SUV data demonstrated that the avgSUV measurements have the most significant differences between 1 versus 2 iterations and 2 versus 3 iterations. The P values for these comparisons were less then 0.001. For maxSUV, all differences had P values less than 0.001. There also was a systematic increase in the SUVs as the number of iterations increased. The avgSUV increased at early iterations (less than 5), with just 50%–60% increasing after 5 iterations. However, maxSUV increased systematically at early iterations, and this trend continued as the number of iterations increased. Conclusion: The OSEM algorithm converges sooner for avgSUV than for maxSUV. The likely reason is that avgSUV depends on low-frequency features that are recovered with fewer iterations. The differences in maxSUV were likely due to noise, which increased with the number of iterative updates, and to increased resolution and recovery of high-frequency features (i.e., tumor heterogeneity) with a larger number of iterations. Factors that determine the quantitative accuracy of iterative reconstruction may have played an additional role. Given the continued change in maxSUV with iterations, great care must be taken in selecting the number of iterative updates when using it to assess tumors and their response to chemotherapy and radiation therapy. Because 2–5 iterations with 8–28 subsets are being used in clinical settings, these data are pertinent when comparing the SUVs of a tumor before and after therapy.

Key Words: tumor • 18F-FDG • ordered-subsets expectation maximization • number of iterations • maximum SUV




This article has been cited by other articles:


Home page
JNMHome page
D. Hellwig, T. P. Graeter, D. Ukena, A. Groeschel, G. W. Sybrecht, H.-J. Schaefers, and C.-M. Kirsch
18F-FDG PET for Mediastinal Staging of Lung Cancer: Which SUV Threshold Makes Sense?
J. Nucl. Med., November 1, 2007; 48(11): 1761 - 1766.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. Soret, S. L. Bacharach, and I. Buvat
Partial-Volume Effect in PET Tumor Imaging
J. Nucl. Med., June 1, 2007; 48(6): 932 - 945.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C.-Y. O. Wong, P. Mahajan, and D. Yan
Dynamic Threshold for Radiation Target Volume by PET/CT
J. Nucl. Med., May 1, 2007; 48(5): 849 - 849.
[Full Text] [PDF]


Home page
JNMHome page
B.-K. Teo, Y. Seo, S. L. Bacharach, J. A. Carrasquillo, S. K. Libutti, H. Shukla, B. H. Hasegawa, R. A. Hawkins, and B. L. Franc
Partial-Volume Correction in PET: Validation of an Iterative Postreconstruction Method with Phantom and Patient Data
J. Nucl. Med., May 1, 2007; 48(5): 802 - 810.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. J. Biehl, F.-M. Kong, F. Dehdashti, J.-Y. Jin, S. Mutic, I. El Naqa, B. A. Siegel, and J. D. Bradley
18F-FDG PET Definition of Gross Tumor Volume for Radiotherapy of Non-Small Cell Lung Cancer: Is a Single Standardized Uptake Value Threshold Approach Appropriate?
J. Nucl. Med., November 1, 2006; 47(11): 1808 - 1812.
[Abstract] [Full Text] [PDF]