|
|
|||||||||
Clinical Investigations |
1 Nuclear Medicine Service, "S. Maria della Misericordia" Hospital, Rovigo, Italy
2 Department of Surgery, University of Padua Medical School, Padua, Italy
3 Regional Center of Nuclear Medicine, University of Pisa Medical School, Pisa, Italy
4 Nuclear Medicine Service, "S. Camillo-Forlanini" Hospital, Rome, Italy
5 Nuclear Medicine Service, "Careggi" University Hospital, Florence, Italy
6 Nuclear Medicine Service, "S. Martino" University Hospital, Genoa, Italy
7 Department of Surgery, University of Turin Medical School, Turin, Italy
8 Division of Surgery, "S. Camillo-Forlanini" Hospital, Rome, Italy
This study evaluated the accuracy of 99mTc-sestamibi scintigraphy and neck ultrasonography in patients with primary hyperparathyroidism (PHPT) and the role of intraoperative hand-held
-probes in minimally invasive radioguided surgery (MIRS) of patients with a high likelihood of a solitary parathyroid adenoma (PA). The study was undertaken under the aegis of the Italian Study Group on Radioguided Surgery and Immunoscintigraphy (GISCRIS). Methods: Clinical records were reviewed for 384 consecutive PHPT patients undergoing radioguided surgery using a low dose of 99mTc-sestamibi. Selection of patients for MIRS instead of traditional bilateral neck exploration was based on preoperative imaging indicating a solitary PA. 99mTc-Sestamibi (37110 MBq, or 13 mCi) was injected in the operating theater 1030 min before the start of the intervention. Either 11-mm collimated (309 patients) or 14-mm collimated (75 patients)
-probes were used. Intraoperative quick parathyroid hormone (IQPTH) assay was used on 308 patients (80.2%). Results: MIRS was successfully performed on 268 (96.8%) of 277 patients. Conversion to bilateral neck exploration was necessary in 9 patients (3.3%) because of either persistently high IQPTH levels after removal of the preoperatively visualized PA (4 patients), intraoperative frozen-section diagnosis of parathyroid carcinoma (2 patients), or hard-to-remove PA (3 patients). MIRS, which was performed under locoregional anesthesia in 72 patients, required a mean operating time of 37 min and a mean hospital stay of 1.2 d. MIRS was successfully performed also on 32 (78.0%) of 41 patients who had previously undergone thyroid or parathyroid surgery. No major surgical complications were observed in the MIRS group, and there were only 24 cases (11%) of transient postoperative hypocalcemia. The probe was of little help in patients with concomitant 99mTc-sestamibiavid thyroid nodules and not helpful at all in patients with negative scan findings preoperatively. IQPTH measurement helped to disclose some cases of multigland parathyroid disease. Conclusion: 99mTc-Sestamibi scintigraphy, especially if combined with neck ultrasonography, is highly accurate in selecting PHPT candidates for MIRS. The low-dose 99mTc-sestamibi protocol (which entails a low-to-negligible radiation exposure to the surgical team) is safe and effective for MIRS. MIRS plays a limited role in patients with concomitant 99mTc-sestamibiavid thyroid nodules and should be discouraged in patients with negative 99mTc-sestamibi finding preoperatively. IQPTH can be recommended during MIRS to facilitate intraoperative identification of previously undiagnosed multigland parathyroid disease.
Key Words: primary hyperparathyroidism solitary parathyroid adenoma minimally invasive parathyroidectomy radioguided surgery 99mTc-sestamibi scintigraphy neck ultrasonography
Related articles in JNM:
This article has been cited by other articles:
![]() |
P Iglesias and J J Diez Current treatments in the management of patients with primary hyperparathyroidism Postgrad. Med. J., January 1, 2009; 85(999): 15 - 23. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. B. Tomas, P. V. Pugliese, G. G. Tronco, C. Love, C. J. Palestro, and K. J. Nichols Pinhole Versus Parallel-Hole Collimators for Parathyroid Imaging: An Intraindividual Comparison J. Nucl. Med. Technol., December 1, 2008; 36(4): 189 - 194. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. J. Nichols, M. B. Tomas, G. G. Tronco, J. N. Rini, B. D. Kunjummen, K. S. Heller, L. A. Sznyter, and C. J. Palestro Preoperative Parathyroid Scintigraphic Lesion Localization: Accuracy of Various Types of Readings Radiology, July 1, 2008; 248(1): 221 - 232. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | RSS | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |