JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fuster, D.
Right arrow Articles by Alavi, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fuster, D.
Right arrow Articles by Alavi, A.
Journal of Nuclear Medicine Vol. 45 No. 8 1323-1327
© 2004 by Society of Nuclear Medicine


Clinical Investigations

Is 18F-FDG PET More Accurate Than Standard Diagnostic Procedures in the Detection of Suspected Recurrent Melanoma?

David Fuster, MD1, Stephen Chiang, MD1, Germaine Johnson, MD1, Lynn M. Schuchter, MD2, Hongming Zhuang, MD, PhD1 and Abass Alavi, MD1

1 Nuclear Medicine Division, Radiology Department, University of Pennsylvania, Philadelphia, Pennsylvania
2 Hematology/Oncology Division, Department of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania

The aim of this study was to determine the accuracy of 18F-FDG PET in detecting recurrent melanoma. Methods: PET findings were compared with those obtained by standard diagnostic clinical procedures (CP) to establish the role of PET in the management of patients with melanoma. From 156 patients with confirmed melanoma and recurrence suspected by clinical examination, 184 PET scans were retrospectively reviewed. Histology or clinical follow-up was used for final diagnosis. Results: The sensitivity and specificity of PET for detecting lesions on an individual-patient basis were 74% and 86%, respectively, compared with respective values of 58% and 45% for CP alone. The overall accuracy for PET was 81%, compared with 52% for other methods. PET was more accurate (91% vs. 67%) than CP in detecting locoregional disease and distant metastases (85% vs. 55%), and PET results led to a change in the planned clinical management of 36% of patients included in this study. PET was more accurate than CT in detecting skin lesions, malignant lymph nodes, and metastases to the abdomen, liver, and bone. In the assessment of pulmonary disease, PET showed higher specificity (92% vs. 70%) than CT for the detection of lung parenchyma lesions; however, the sensitivity was better for CT (93%) than for PET (57%). Conclusion: PET is better than CP in detecting locoregional disease and distant metastases in all sites except the lung, where it appears to be a useful adjunct to CT. The use of PET as a routine clinical tool can lead to a substantial change in the clinical management of suspected recurrent melanoma.

Key Words: 18F-FDG • PET • melanoma • diagnosis • metastases


Related articles in JNM:

THIS MONTH IN JNM

JNM 2004 45: 8A-9A. [Full Text]  



This article has been cited by other articles:


Home page
RadiologyHome page
B. Krug, R. Crott, M. Lonneux, J.-F. Baurain, A.-S. Pirson, and T. Vander Borght
Role of PET in the Initial Staging of Cutaneous Malignant Melanoma: Systematic Review
Radiology, December 1, 2008; 249(3): 836 - 844.
[Abstract] [Full Text] [PDF]


Home page
Clin. Microbiol. Rev.Home page
R. Kumar, S. Basu, D. Torigian, V. Anand, H. Zhuang, and A. Alavi
Role of Modern Imaging Techniques for Diagnosis of Infection in the Era of 18F-Fluorodeoxyglucose Positron Emission Tomography
Clin. Microbiol. Rev., January 1, 2008; 21(1): 209 - 224.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. M. Blodgett, C. C. Meltzer, and D. W. Townsend
PET/CT: Form and Function
Radiology, February 1, 2007; 242(2): 360 - 385.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
T. Z. Belhocine, A. M. Scott, E. Even-Sapir, J.-L. Urbain, and R. Essner
Role of Nuclear Medicine in the Management of Cutaneous Malignant Melanoma
J. Nucl. Med., June 1, 2006; 47(6): 957 - 967.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
M. J. Reinhardt, A. Y. Joe, U. Jaeger, A. Huber, A. Matthies, J. Bucerius, R. Roedel, H. Strunk, T. Bieber, H.-J. Biersack, et al.
Diagnostic Performance of Whole Body Dual Modality 18F-FDG PET/CT Imaging for N- and M-Staging of Malignant Melanoma: Experience With 250 Consecutive Patients
J. Clin. Oncol., March 1, 2006; 24(7): 1178 - 1187.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
M. E. Juweid and B. D. Cheson
Positron-Emission Tomography and Assessment of Cancer Therapy
N. Engl. J. Med., February 2, 2006; 354(5): 496 - 507.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2004 by the Society of Nuclear Medicine.