JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Levivier, M.
Right arrow Articles by Goldman, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Levivier, M.
Right arrow Articles by Goldman, S.
Journal of Nuclear Medicine Vol. 45 No. 7 1146-1154
© 2004 by Society of Nuclear Medicine


Clinical Investigations

Use of Stereotactic PET Images in Dosimetry Planning of Radiosurgery for Brain Tumors: Clinical Experience and Proposed Classification

Marc Levivier, MD, PhD1, Nicolas Massager, MD1, David Wikler, MS2, José Lorenzoni, MD1, Salvador Ruiz, MD1, Daniel Devriendt, MD3, Philippe David, MD4, Françoise Desmedt, MS3, Stéphane Simon, MS3, Paul Van Houtte, MD3, Jacques Brotchi, MD1 and Serge Goldman, MD2

1 Department of Neurosurgery and Centre Gamma Knife, Hôpital Erasme and Université Libre de Bruxelles, Brussels, Belgium
2 PET/Biomedical Cyclotron Unit, Hôpital Erasme, Brussels, Belgium
3 Department of Radiation Therapy and Laboratory of Physics, Institut Jules Bordet, Brussels, Belgium
4 Department of Radiology, Hôpital Erasme, Brussels, Belgium

We developed a technique that allows the routine integration of PET in stereotactic neurosurgery, including radiosurgery. We report our clinical experience with the combined use of metabolic (i.e., PET) and anatomic (i.e., MRI and CT) images for the radiosurgical treatment of brain tumors. We propose a classification describing the relative role of the information provided by PET in this multimodality image-guided approach. Methods: Between December 1999 and March 2003, 57 patients had stereotactic PET as part of their image acquisition for the planning of gamma knife radiosurgery. Together with stereotactic MRI and CT, stereotactic PET images were acquired on the same day using either 18F-FDG or 11C-methionine. PET images were imported in the planning software for the radiosurgery dosimetry, and the target volume was defined using the combined information of PET and MRI or CT. To analyze the specific contribution of the PET findings, we propose a classification that reflects the strategy used to define the target volume. Results: The patients were offered radiosurgery with PET guidance when their tumor was ill-defined and we anticipated some limitation of target definition on MRI alone. This represents 10% of the radiosurgery procedures performed in our center during the same period of time. There were 40 primary brain lesions, 7 metastases, and 10 pituitary adenomas. Abnormal PET uptake was found in 62 of 72 targets (86%), and this information altered significantly the MRI-defined tumor in 43 targets (69%). Conclusion: The integration of PET in radiosurgery provides additional information that opens new perspectives for the optimization of the treatment of brain tumors.

Key Words: PET • radiosurgery • gamma knife • stereotaxis • brain tumor


Related articles in JNM:

This Month in JNM

JNM 2004 45: 13A-14A. [Full Text]  



This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
T. Kato, J. Shinoda, N. Nakayama, K. Miwa, A. Okumura, H. Yano, S. Yoshimura, T. Maruyama, Y. Muragaki, and T. Iwama
Metabolic Assessment of Gliomas Using 11C-Methionine, [18F] Fluorodeoxyglucose, and 11C-Choline Positron-Emission Tomography
AJNR Am. J. Neuroradiol., June 1, 2008; 29(6): 1176 - 1182.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
N. Sadeghi, I. Salmon, C. Decaestecker, M. Levivier, T. Metens, D. Wikler, V. Denolin, S. Rorive, N. Massager, D. Baleriaux, et al.
Stereotactic Comparison among Cerebral Blood Volume, Methionine Uptake, and Histopathology in Brain Glioma
AJNR Am. J. Neuroradiol., March 1, 2007; 28(3): 455 - 461.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
B. Pirotte, S. Goldman, N. Massager, P. David, D. Wikler, A. Vandesteene, I. Salmon, J. Brotchi, and M. Levivier
Comparison of 18F-FDG and 11C-Methionine for PET-Guided Stereotactic Brain Biopsy of Gliomas
J. Nucl. Med., August 1, 2004; 45(8): 1293 - 1298.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2004 by the Society of Nuclear Medicine.