JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by van der Weerdt, A. P.
Right arrow Articles by Visser, F. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by van der Weerdt, A. P.
Right arrow Articles by Visser, F. C.
Journal of Nuclear Medicine Vol. 45 No. 2 169-175
© 2004 by Society of Nuclear Medicine


Clinical Investigations

Postinjection Transmission Scanning in Myocardial 18F-FDG PET Studies Using Both Filtered Backprojection and Iterative Reconstruction

Arno P. van der Weerdt, MD1, Ronald Boellaard, PhD2, Paul Knaapen, MD1, Cees A. Visser, MD1, Adriaan A. Lammertsma, PhD2 and Frans C. Visser, MD1

1 Department of Cardiology, Institute for Cardiovascular Research-VU, VU University Medical Center, Amsterdam, The Netherlands
2 PET Center, Institute for Cardiovascular Research-VU, VU University Medical Center, Amsterdam, The Netherlands

The aim of the present study was to evaluate the effect of postinjection transmission scanning (Post-Tx) on both the qualitative interpretation and the quantitative analysis of cardiac 18F-FDG PET images. Furthermore, the accuracy of 2 different methods to correct for emission contamination was studied. An additional aim of this study was to compare images reconstructed with both standard filtered backprojection (FBP) and an iterative reconstruction algorithm (ordered-subset maximization expectation [OSEM]). Methods: Sixteen patients underwent dynamic 18F-FDG imaging. Both before injection of 18F-FDG and after completing the emission scan, a 10-min transmission scan was performed (Pre-Tx and Post-Tx, respectively). Images were reconstructed using both FBP and OSEM. The emission study reconstructed with Pre-Tx was considered to be the gold standard. Emission studies were also reconstructed with Post-Tx, with and without correction for emission contamination. Correction for emission contamination was performed with either transmission image segmentation (TIS) or by estimating the emission bias from the last emission frame (dwell profile [DP] method). All images were then compared by calculating ratios of 18F-FDG activity between corresponding myocardial segments in each patient. Furthermore, qualitative grading of 18F-FDG uptake was compared between the studies. Results: The mean ratio of 18F-FDG activity between segments from FBP-Post and FBP-Pre was 0.78 ± 0.08. When TIS and DP were used, the mean ratios were 0.80 ± 0.07 and 0.94 ± 0.06, respectively. The use of OSEM resulted in, on average, 2% lower values for 18F-FDG activity as compared with FBP. The mean normalized 18F-FDG uptake was higher in FBP-Post, especially in segments with decreased 18F-FDG activity. Only in the case of DP were no significant differences observed as compared with FBP-Pre. In general, qualitative analysis of the images showed that the agreement between the reconstruction methods was comparable with the reproducibility of FBP-Pre. Conclusion: Post-Tx for attenuation correction in cardiac 18F-FDG PET scans resulted in substantial underestimation of 18F-FDG activity. More accurate results were obtained with correction for emission contamination using DP. Differences in visual assessment of 18F-FDG images were small. Finally, iterative reconstruction could be used as an alternative to FBP in static 18F-FDG imaging of the heart.

Key Words: PET • postinjection transmission scanning • 18F-FDG • iterative reconstruction




This article has been cited by other articles:


Home page
CirculationHome page
R. W. van der Meer, L. J. Rijzewijk, H. W.A.M. de Jong, H. J. Lamb, M. Lubberink, J. A. Romijn, J. J. Bax, A. de Roos, O. Kamp, W. J. Paulus, et al.
Pioglitazone Improves Cardiac Function and Alters Myocardial Substrate Metabolism Without Affecting Cardiac Triglyceride Accumulation and High-Energy Phosphate Metabolism in Patients With Well-Controlled Type 2 Diabetes Mellitus
Circulation, April 21, 2009; 119(15): 2069 - 2077.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. Seret, R. Boellaard, and A. van der Weerdt
Number of Iterations When Comparing MLEM/OSEM with FBP
J. Nucl. Med., December 1, 2004; 45(12): 2125 - 2126.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2004 by the Society of Nuclear Medicine.