JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schaefer, W. M.
Right arrow Articles by Buell, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schaefer, W. M.
Right arrow Articles by Buell, U.
Journal of Nuclear Medicine Vol. 45 No. 12 2016-2020
© 2004 by Society of Nuclear Medicine


Clinical Investigations

Prone Versus Supine Patient Positioning During Gated 99mTc-Sestamibi SPECT: Effect on Left Ventricular Volumes, Ejection Fraction, and Heart Rate

Wolfgang M. Schaefer, MD, PhD1, Claudia S.A. Lipke, MD2, Harald P. Kühl, MD2, Karl-Christian Koch, MD2, Hans-Juergen Kaiser, PhD1, Patrick Reinartz, MD1, Bernd Nowak, MD1 and Udalrich Buell, MD1

1 Department of Nuclear Medicine, University Hospital Aachen, Aachen, Germany
2 Medical Clinic I (Cardiology), University Hospital Aachen, Aachen, Germany

Gated myocardial perfusion SPECT allows assessment of left ventricular end-diastolic volume (EDV), left ventricular end-systolic volume (ESV), left ventricular stroke volume (SV), and left ventricular ejection fraction (LVEF). Acquiring images with the patient both prone and supine is an approved method of identifying and reducing artifacts. Yet prone positioning alters physiologic conditions. This study investigated how prone versus supine patient positioning during gated SPECT affects EDV, ESV, SV, LVEF, and heart rate. Methods: Forty-eight patients scheduled for routine myocardial perfusion imaging were examined with gated 99mTc-sestamibi SPECT (at rest) while positioned prone and supine (consecutively, in random order). All parameters for both acquisitions were calculated using the commercially available QGS algorithm. Results: Whereas EDV and SV were significantly lower (P < 0.0004) for prone acquisitions (EDV, 110.5 ± 39.1 mL; SV, 55.9 ± 13.3 mL) than for supine acquisitions (EDV, 116.9 ± 36.2 mL; SV, 61.0 ± 14.5 mL), ESV and LVEF did not differ significantly. Heart rate was significantly higher (P < 0.0001) during prone acquisitions (69.1 ± 10.5 min–1) than during supine acquisitions (66.5 ± 10.0 min–1). Conclusion: The observed position-dependent effect on EDV, SV, and heart rate might be explained by decreased arterial filling and increased sympathetic nerve activity. Hence, supine reference data should not be used to classify the results of prone acquisitions.

Key Words: gated SPECT • prone versus supine • left ventricular volumes • heart rate


Related articles in JNM:

THIS MONTH IN JNM

JNM 2004 45: 8a-9a. [Full Text]  



This article has been cited by other articles:


Home page
Crit Care NurseHome page
C. A. Rauen, M. B. F. Makic, and E. Bridges
Evidence-Based Practice Habits: Transforming Research Into Bedside Practice
Crit. Care Nurse, April 1, 2009; 29(2): 46 - 59.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2004 by the Society of Nuclear Medicine.