JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lubberink, M.
Right arrow Articles by Lammertsma, A. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lubberink, M.
Right arrow Articles by Lammertsma, A. A.
Journal of Nuclear Medicine Vol. 45 No. 12 2008-2015
© 2004 by Society of Nuclear Medicine


Clinical Investigations

Quantitative Comparison of Analytic and Iterative Reconstruction Methods in 2- and 3-Dimensional Dynamic Cardiac 18F-FDG PET

Mark Lubberink, PhD1, Ronald Boellaard, PhD1, Arno P. van der Weerdt, MD2, Frans C. Visser, MD, PhD2 and Adriaan A. Lammertsma, PhD1

1 Department of Nuclear Medicine and PET Research, VU University Medical Centre, Amsterdam, The Netherlands
2 Department of Cardiology, VU University Medical Centre, Amsterdam, The Netherlands

The aim of this work was to compare the quantitative accuracy of iteratively reconstructed cardiac 18F-FDG PET with that of filtered backprojection for both 2-dimensional (2D) and 3-dimensional (3D) acquisitions and to establish an optimal procedure for imaging myocardial viability with 18F-FDG PET. Methods: Eight patients underwent dynamic cardiac 18F-FDG PET using an interleaved 2D/3D scan protocol, enabling comparison of 2D and 3D acquisitions within the same patient and study. A 10-min transmission scan was followed by a 10-min, 25-frame dynamic 3D scan and then by a series of 10 alternating 5-min 3D and 2D scans. Images were reconstructed with filtered backprojection (FBP) or attenuation-weighted ordered-subsets expectation maximization (OSEM), combined with Fourier rebinning (FORE) for 3D acquisitions, applying all usual corrections. Regions of interest (ROIs) were drawn in the myocardium, left ventricle, and ascending aorta, with the last 2 being used to define image-derived input functions (IDIFs). Patlak graphical analysis was used to compare net 18F-FDG uptake in the myocardium, calculated from either 2D or 3D data, after reconstruction with FBP or OSEM. Either IDIFs or arterial sampling was used as the input function. The same analysis was performed on parametric images. Results: A good correlation (r2 > 0.99) was found between net 18F-FDG uptake values for a myocardium ROI determined using each acquisition and reconstruction method and blood-sampling input functions. A similar result was found for parametric images. The ascending aorta was the best choice for IDIF definition. Conclusion: Good correlation and no bias of net 18F-FDG uptake in relation to that based on FBP images, combined with less image noise, make 3D acquisition with FORE plus attenuation-weighted OSEM reconstruction the preferred choice for cardiac 18F-FDG PET studies.

Key Words: cardiac PET • 18F-FDG • iterative reconstruction • quantification


Related articles in JNM:

THIS MONTH IN JNM

JNM 2004 45: 8a-9a. [Full Text]  



This article has been cited by other articles:


Home page
J. Nucl. Med. Technol.Home page
B. Sanghera, G. Lowe, D. Wellstead, J. Lowe, J. Chambers, and W. Wong
Scan-Time Reduction Using Noise-Matched Images in 2- and 3-Dimensional Bismuth Germanate PET/CT: Clinical Study in Head and Neck Cancer
J. Nucl. Med. Technol., June 1, 2009; 37(2): 74 - 82.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
T. Schepis, O. Gaemperli, V. Treyer, I. Valenta, C. Burger, P. Koepfli, M. Namdar, I. Adachi, H. Alkadhi, and P. A. Kaufmann
Absolute Quantification of Myocardial Blood Flow with 13N-Ammonia and 3-Dimensional PET
J. Nucl. Med., November 1, 2007; 48(11): 1783 - 1789.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
G. P. Chen, K. R. Branch, A. M. Alessio, P. Pham, R. Tabibiazar, P. Kinahan, and J. H. Caldwell
Effect of Reconstruction Algorithms on Myocardial Blood Flow Measurement with 13N-Ammonia PET
J. Nucl. Med., August 1, 2007; 48(8): 1259 - 1265.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. Martinez-Moller, M. Souvatzoglou, N. Navab, M. Schwaiger, and S. G. Nekolla
Artifacts from Misaligned CT in Cardiac Perfusion PET/CT Studies: Frequency, Effects, and Potential Solutions
J. Nucl. Med., February 1, 2007; 48(2): 188 - 193.
[Abstract] [Full Text] [PDF]


Home page
J PsychopharmacolHome page
A. L. Malizia
The role of emission tomography in pharmacokinetic and pharmacodynamic studies in clinical psychopharmacology
J Psychopharmacol, July 1, 2006; 20(4_suppl): 100 - 107.
[Abstract] [PDF]


Home page
JNMHome page
M. Schwaiger, S. Ziegler, and S. G. Nekolla
PET/CT: Challenge for Nuclear Cardiology
J. Nucl. Med., October 1, 2005; 46(10): 1664 - 1678.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2004 by the Society of Nuclear Medicine.