JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Katoh, C.
Right arrow Articles by Tamaki, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Katoh, C.
Right arrow Articles by Tamaki, N.
Journal of Nuclear Medicine Vol. 45 No. 11 1908-1916
© 2004 by Society of Nuclear Medicine


Basic Science Investigations

Improvement of Algorithm for Quantification of Regional Myocardial Blood Flow Using 15O-Water with PET

Chietsugu Katoh, MD1,2, Koichi Morita, MD3, Tohru Shiga, MD3, Naoki Kubo, MD2, Kunihiro Nakada, MD3 and Nagara Tamaki, MD3

1 Department of Tracer Kinetics, Hokkaido University School of Medicine, Sapporo, Japan
2 Department of Health Science, Hokkaido University School of Medicine, Sapporo, Japan
3 Department of Nuclear Medicine, Hokkaido University School of Medicine, Sapporo, Japan

15O-Water and dynamic PET allow noninvasive quantification of myocardial blood flow (MBF). However, complicated image analyzing procedures are required, which may limit the practicality of this approach. We have designed a new practical algorithm, which allows stable, rapid, and automated quantification of regional MBF (rMBF) using 15O-water PET. We designed an algorithm for setting the 3-dimensional (3D) region of interest (ROI) of the whole myocardium semiautomatically. Subsequently, a uniform input function was calculated for each subject using a time–activity curve in the 3D whole myocardial ROI. The uniform input function allows the mathematically simple and robust algorithm to estimate rMBF. Methods: Thirty-six volunteers were used in the static 15O-CO and dynamic 15O-water PET studies. To evaluate the reproducibility of the estimates, a repeated 15O-water scan was obtained under resting condition. In addition, to evaluate the stability of the new algorithm in the hyperemic state, a 15O-water scan was obtained with adenosine triphosphate. This algorithm includes a procedure for positioning a 3D ROI of the whole myocardium from 3D images and dividing it into 16 segments. Subsequently, the uniform input function was calculated using time–activity curves in the whole myocardial ROI and in the LV ROI. The uniform input function allowed this simple and robust algorithm to estimate the rMBF, perfusable tissue fraction (PTF), and spillover fraction (Va) according to a single tissue compartment model. These estimates were compared with those calculated using the original method. A simulation study was performed to compare the effects of errors in PTF or Va on the MBF using the 2 methods. Results: The average operating time for positioning a whole myocardial ROI and 16 regional myocardial ROIs was <5 min. The new method yielded less deviation in rMBF (0.876 ± 0.177 mL/min/g, coefficient of variation [CV] = 20.2%, n = 576) than those with the traditional method (0.898 ± 0.271 mL/min/g, CV = 30.1%, n = 576) (P < 0.01). In the hyperemic state, the new method yielded less deviation in rMBF (3.890 ± 1.250 mL/min/g, CV = 32.1%) than those with the traditional method (3.962 ± 1.762 mL/min/g, CV = 44.4%) (P < 0.05). This method yielded significantly higher reproducibility of rMBF (r = 0.806, n = 576) than the original method (r = 0.756, n = 576) (P < 0.05). Our new method yielded a better correlation in the repeated measurement values of rMBF and less variability among the regions in the myocardium than with the original theory of the 15O-water technique. The simulation study demonstrated fewer effects of error in the PTF or Va on the MBF value with the new method. Conclusion: We have developed a technique for an automated, simplified, and stable algorithm to quantify rMBF. This software is considered to be practical for clinical use in myocardial PET studies using 15O-water with a high reproducibility and a short processing time.

Key Words: myocardial blood flow • 15O-water • PET


Related articles in JNM:

THIS MONTH IN JNM

JNM 2004 45: 8A-9A. [Full Text]  



This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
M. Naya, T. Tsukamoto, K. Morita, C. Katoh, T. Furumoto, S. Fujii, N. Tamaki, and H. Tsutsui
Olmesartan, But Not Amlodipine, Improves Endothelium-Dependent Coronary Dilation in Hypertensive Patients
J. Am. Coll. Cardiol., September 18, 2007; 50(12): 1144 - 1149.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. Morita, T. Tsukamoto, M. Naya, K. Noriyasu, M. Inubushi, T. Shiga, C. Katoh, Y. Kuge, H. Tsutsui, and N. Tamaki
Smoking Cessation Normalizes Coronary Endothelial Vasomotor Response Assessed with 15O-Water and PET in Healthy Young Smokers
J. Nucl. Med., December 1, 2006; 47(12): 1914 - 1920.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
P. Chareonthaitawee, S. D. Christenson, J. L. Anderson, B. J. Kemp, D. O. Hodge, E. L. Ritman, and R. J. Gibbons
Reproducibility of Measurements of Regional Myocardial Blood Flow in a Model of Coronary Artery Disease: Comparison of H215O and 13NH3 PET Techniques
J. Nucl. Med., July 1, 2006; 47(7): 1193 - 1201.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2004 by the Society of Nuclear Medicine.