JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schaefer, W. M.
Right arrow Articles by Kühl, H. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schaefer, W. M.
Right arrow Articles by Kühl, H. P.
Journal of Nuclear Medicine Vol. 45 No. 1 74-79
© 2004 by Society of Nuclear Medicine


Brief Communications

Validation of QGS and 4D-MSPECT for Quantification of Left Ventricular Volumes and Ejection Fraction from Gated 18F-FDG PET: Comparison with Cardiac MRI

Wolfgang M. Schaefer, MD, PhD1, Claudia S.A. Lipke, MD2, Bernd Nowak, MD1, Hans-Juergen Kaiser, PhD1, Patrick Reinartz, MD1, Arno Buecker, MD3, Gabriele A. Krombach, MD3, Udalrich Buell, MD1 and Harald P. Kühl, MD2

1 Department of Nuclear Medicine, University Hospital, University of Aachen, Aachen, Germany
2 Medical Clinic I, University Hospital, University of Aachen, Aachen, Germany
3 Department of Radiology, University Hospital, University of Aachen, Aachen, Germany

ABSTRACT

The aim of this study was to validate Quantitative Gated SPECT (QGS) and 4D-MSPECT for assessing left ventricular end-diastolic and systolic volumes (EDV and ESV, respectively) and left ventricular ejection fraction (LVEF) from gated 18F-FDG PET. Methods: Forty-four patients with severe coronary artery disease were examined with gated 18F-FDG PET (8 gates per cardiac cycle). EDV, ESV, and LVEF were calculated from gated 18F-FDG PET using QGS and 4D-MSPECT. Within 2 d (median), cardiovascular cine MRI (cMRI) (20 gates per cardiac cycle) was done as a reference. Results: QGS failed to accurately detect myocardial borders in 1 patient; 4D-MSPECT, in 2 patients. For the remaining 42 patients, correlation between the results of gated 18F-FDG PET and cMRI was high for EDV (R = 0.94 for QGS and 0.94 for 4D-MSPECT), ESV (R = 0.95 for QGS and 0.95 for 4D-MSPECT), and LVEF (R = 0.94 for QGS and 0.90 for 4D-MSPECT). QGS significantly (P < 0.0001) underestimated LVEF, whereas no other parameter differed significantly between gated 18F-FDG PET and cMRI for either algorithm. Conclusion: Despite small systematic differences that, among other aspects, limit interchangeability, agreement between gated 18F-FDG PET and cMRI is good across a wide range of clinically relevant volumes and LVEF values assessed by QGS and 4D-MSPECT.

Key Words: gated 18F-FDG PET • cardiovascular MRI • Quantitative Gated SPECT • 4D-MSPECT




This article has been cited by other articles:


Home page
JNMHome page
A. Chander, M. Brenner, R. Lautamaki, C. Voicu, J. Merrill, and F. M. Bengel
Comparison of Measures of Left Ventricular Function from Electrocardiographically Gated 82Rb PET with Contrast-Enhanced CT Ventriculography: A Hybrid PET/CT Analysis
J. Nucl. Med., October 1, 2008; 49(10): 1643 - 1650.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
G. S. Lin, H. H. Hines, G. Grant, K. Taylor, and C. Ryals
Automated Quantification of Myocardial Ischemia and Wall Motion Defects by Use of Cardiac SPECT Polar Mapping and 4-Dimensional Surface Rendering.
J. Nucl. Med. Technol., March 1, 2006; 34(1): 3 - 17.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. Khorsand, S. Graf, H. Eidherr, W. Wadsak, K. Kletter, H. Sochor, E. Schuster, and G. Porenta
Gated Cardiac 13N-NH3 PET for Assessment of Left Ventricular Volumes, Mass, and Ejection Fraction: Comparison with Electrocardiography-Gated 18F-FDG PET
J. Nucl. Med., December 1, 2005; 46(12): 2009 - 2013.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2004 by the Society of Nuclear Medicine.