JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Knesaurek, K.
Right arrow Articles by Almeida, O. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Knesaurek, K.
Right arrow Articles by Almeida, O. D.
Journal of Nuclear Medicine Vol. 44 No. 8 1350-1356
© 2003 by Society of Nuclear Medicine


Basic Science Investigations

Comparison of 2-Dimensional and 3-Dimensional 82Rb Myocardial Perfusion PET Imaging

Karin Knesaurek, PhD;, Josef Machac, MD, Borys R. Krynyckyi, MD and Orlandino D. Almeida, MD

Division of Nuclear Medicine, Mount Sinai Medical Center, New York, New York

We compared 2-dimensional (2D) and 3-dimensional (3D) 82Rb PET imaging in 3 different experiments: in a realistic heart–thorax phantom, in a uniformity-resolution phantom, and in 14 healthy volunteers. Methods: A nonuniform heart–thorax phantom was filled with 111 MBq of 82Rb injected into the left ventricular (LV) wall. In the LV wall of the cardiac phantom, 3 inserts—1, 2, and 3 cm in diameter—were placed to simulate infarcts. A standard rest cardiac PET imaging protocol in 2D and 3D modes was used. Following the same protocol, a uniformity-resolution phantom with uniformly distributed activity of 1,998 MBq and 740 MBq of 82Rb in water was used to obtain 2D PET images and 3D PET images, respectively. All 2D volunteer studies were performed by injecting 2,220 MBq of 82Rb intravenously. For half the volunteers, 3D studies were performed with a high dose (HD) (2,220 MBq) of 82Rb; for the remainder of the 3D studies, a low dose (LD) (740 MBq) of 82Rb was used. In the 2D and LD 3D studies, there was a delay of 2 min and 3 min, respectively, followed by a 6-min acquisition. In the HD 3D volunteer studies, there was a delay of 5 min followed by a 6-min acquisition. Circumferential profiles of the short-axis slices and the contrast of the inserts were used to evaluate the cardiac phantom PET images. The transaxial slices from the uniformity-resolution phantom were evaluated by visual inspection and by measuring uniformity. The human studies were evaluated by measuring the contrast between LV wall and LV cavity, using linear profiles and visual analysis. Results: In the cardiac phantom study, circumferential profiles for the 2D and 3D images were similar. The contrast values for the 1-, 2-, and 3-cm inserts in the 2D study were 0.19 ± 0.03, 0.34 ± 0.05, and 0.61 ± 0.03, respectively. The respective contrast values in the 3D study were 0.15 ± 0.02, 0.36 ± 0.04, and 0.52 ± 0.05. In the uniformity-resolution phantom study, the coefficients of variation, calculated for a representative uniform slice, were 5.3% and 7.6% for the 2D and 3D studies, respectively. For the 7 volunteers on whom HD 3D was used, the mean 2D contrast was 0.33 ± 0.08 and the mean HD 3D contrast was 0.35 ± 0.08 (P = not statistically significant). For the other 7 volunteers, on whom LD 3D was used, the mean 2D contrast was 0.39 ± 0.06 and the mean LD 3D contrast was 0.39 ± 0.10 (P = not statistically significant). In the tomographic slices, the 2D and 3D images and polar plots were similar. Conclusion: When obtained with a PET system having a high counting-rate performance, 2D and 3D 82Rb PET cardiac images are comparable. LD 3D imaging can make 82Rb PET cardiac imaging more affordable.

Key Words: 3-dimensional PET • 2-dimensional PET • 82Rb • myocardial perfusion




This article has been cited by other articles:


Home page
JNMHome page
M. Ibaraki, S. Miura, E. Shimosegawa, S. Sugawara, T. Mizuta, A. Ishikawa, and M. Amano
Quantification of Cerebral Blood Flow and Oxygen Metabolism with 3-Dimensional PET and 15O: Validation by Comparison with 2-Dimensional PET
J. Nucl. Med., January 1, 2008; 49(1): 50 - 59.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
T. Schepis, O. Gaemperli, V. Treyer, I. Valenta, C. Burger, P. Koepfli, M. Namdar, I. Adachi, H. Alkadhi, and P. A. Kaufmann
Absolute Quantification of Myocardial Blood Flow with 13N-Ammonia and 3-Dimensional PET
J. Nucl. Med., November 1, 2007; 48(11): 1783 - 1789.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. A. Lodge, R. D. Badawi, R. Gilbert, P. E. Dibos, and B. R. Line
Comparison of 2-Dimensional and 3-Dimensional Acquisition for 18F-FDG PET Oncology Studies Performed on an LSO-Based Scanner
J. Nucl. Med., January 1, 2006; 47(1): 23 - 31.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. Schwaiger, S. Ziegler, and S. G. Nekolla
PET/CT: Challenge for Nuclear Cardiology
J. Nucl. Med., October 1, 2005; 46(10): 1664 - 1678.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
G. El Fakhri, A. Sitek, B. Guerin, M. F. Kijewski, M. F. Di Carli, and S. C. Moore
Quantitative Dynamic Cardiac 82Rb PET Using Generalized Factor and Compartment Analyses
J. Nucl. Med., August 1, 2005; 46(8): 1264 - 1271.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2003 by the Society of Nuclear Medicine.