1 Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania
2 Philips Medical Systems, Philadelphia, Pennsylvania
A high-sensitivity, high-resolution brain PET scanner ("G-PET") has been developed. This scanner is similar in geometry to a previous brain scanner developed at the University of Pennsylvania, the HEAD Penn-PET, but the detector technology and electronics have been improved to achieve enhanced performance. Methods: This scanner has a detector ring diameter of 42.0 cm with a patient aperture of 30.0 cm and an axial field of view of 25.6 cm. It comprises a continuous light-guide that couples 18,560 (320 x 58 array) 4 x 4 x 10 mm3 gadolinium oxyorthosilicate (GSO) crystals to 288 (36 x 8 array) 39-mm photomultiplier tubes in a hexagonal arrangement. The scanner operates only in 3-dimensional (3D) mode because there are no interplane septa. Performance measurements on the G-PET scanner were made following National Electrical Manufacturers Association NU 22001 procedures for most measurements, although NU 21994 procedures were used when these were considered more appropriate for a brain scanner (e.g., scatter fraction and counting-rate performance measurements). Results: The transverse and axial resolutions near the center are 4.0 and 5.0 mm, respectively. At a radial offset of 10 cm, these numbers deteriorate by approximately 0.5 mm. The absolute sensitivity of this scanner measured with a 70-cm long line source is 4.79 counts per second (cps)/kBq. The scatter fraction measured with a line source in a 20-cm-diameter x 19-cm-long cylinder is 39% (for a lower energy threshold of 410 keV). For the same cylinder, the peak noise equivalent counting rate is 60 kcps at an activity concentration of 7.4 kBq/mL (0.20 µCi/mL), whereas the peak true coincidence rate is 132 kcps at an activity concentration of 14 kBq/mL (0.38 µCi/mL). Images from the Hoffman brain phantom as well as 18F-FDG patient scans illustrate the high quality of images acquired on the G-PET scanner. Conclusion: The G-PET scanner attains the goal of high performance for brain imaging through the use of an Anger-logic GSO detector design with continuous optical coupling. This detector design leads to good energy resolution, which is needed in 3D imaging to minimize scatter and random coincidences.
Key Words: PET brain imaging gadolinium oxyorthosilicate
This article has been cited by other articles:
![]() |
B. J. Pichler, H. F. Wehrl, and M. S. Judenhofer Latest Advances in Molecular Imaging Instrumentation J. Nucl. Med., June 1, 2008; 49(Suppl_2): 5S - 23S. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. T. Hardy, M. Hernandez-Pampaloni, J. R. Saffer, J. S. Scheuermann, L. M. Ernst, R. Freifelder, H. Zhuang, C. MacMullen, S. Becker, N. S. Adzick, et al. Accuracy of [18F]Fluorodopa Positron Emission Tomography for Diagnosing and Localizing Focal Congenital Hyperinsulinism J. Clin. Endocrinol. Metab., December 1, 2007; 92(12): 4706 - 4711. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Surti, A. Kuhn, M. E. Werner, A. E. Perkins, J. Kolthammer, and J. S. Karp Performance of Philips Gemini TF PET/CT Scanner with Special Consideration for Its Time-of-Flight Imaging Capabilities J. Nucl. Med., March 1, 2007; 48(3): 471 - 480. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Rajendran, D. L. Schwartz, J. O'Sullivan, L. M. Peterson, P. Ng, J. Scharnhorst, J. R. Grierson, and K. A. Krohn Tumor hypoxia imaging with [f-18] fluoromisonidazole positron emission tomography in head and neck cancer. Clin. Cancer Res., September 15, 2006; 12(18): 5435 - 5441. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Surti and J. S. Karp Imaging Characteristics of a 3-Dimensional GSO Whole-Body PET Camera J. Nucl. Med., June 1, 2004; 45(6): 1040 - 1049. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |