JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Robeson, W.
Right arrow Articles by Eidelberg, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Robeson, W.
Right arrow Articles by Eidelberg, D.
Journal of Nuclear Medicine Vol. 44 No. 6 961-966
© 2003 by Society of Nuclear Medicine


Basic Science Investigations

Dosimetry of the Dopamine Transporter Radioligand 18F-FPCIT in Human Subjects

William Robeson, MA, Vijay Dhawan, PhD, Abdel Belakhlef, PhD, Yilong Ma, PhD, Von Pillai, BS, Thomas Chaly, PhD, Claude Margouleff, MS, David Bjelke, AAS and David Eidelberg, MD

Center for Neurosciences, North Shore University Hospital, Manhasset, New York

This study was designed to evaluate the radiation dosimetry in human subjects for a new radiopharmaceutical, N-(3-18F-fluoropropyl)-2ß-carbomethoxy-3ß-(4-iodophenyl)nortropane (18F-FPCIT). The goal was to determine a limiting dose consistent with accepted guidelines for use in clinical studies and to compare the radiation burden with other agents such as 123I-FPCIT, 18F-fluorodopa, and 18F-FDG. Methods: Dynamic PET scans of the urinary bladder were obtained in 6 subjects; 2 subjects had brain scans and 5 subjects had scans of the thorax or abdomen. Regions of interest were placed over composite images of each organ for which activity was visualized to generate time–activity curves. Doses were calculated from residence times using the MIRDOSE3 program. Results: The critical organ for dosimetry is the urinary bladder wall with a dose of 0.0586 ± 0.0164 mGy/MBq. The dose comes primarily (97.2%) from activity in the urinary bladder contents. The dose is lower than any of the other agents used commonly in PET to assess dopaminergic function. The effective dose equivalent (0.0120 mGy/MBq) is also lower than comparable compounds. Conclusion: 18F-FPCIT has favorable dosimetry when compared with other agents used to study dopaminergic function. Doses as high as 853 MBq (23 mCi) may be given to adult patients and remain within accepted guidelines.

Key Words: N-(3-fluoropropyl)-2ß-carbomethoxy-3ß-(4-iodophenyl)nortropane • dosimetry • PET • dopamine transporter




This article has been cited by other articles:


Home page
JNMHome page
K. Van Laere, M. Koole, S. M. Sanabria Bohorquez, K. Goffin, I. Guenther, M. J. Belanger, J. Cote, P. Rothenberg, I. De Lepeleire, I. D. Grachev, et al.
Whole-Body Biodistribution and Radiation Dosimetry of the Human Cannabinoid Type-1 Receptor Ligand 18F-MK-9470 in Healthy Subjects
J. Nucl. Med., March 1, 2008; 49(3): 439 - 445.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2003 by the Society of Nuclear Medicine.