Reliable attenuation correction methods for quantitative emission CT (ECT) require accurate delineation of the body contour and often necessitate knowledge of internal anatomic structure. Two broad classes of methods have been used to calculate the attenuation map: transmissionless and transmission-based attenuation correction techniques. Whereas calculated attenuation correction belonging to the first class of methods is appropriate for brain studies, more adequate methods must be performed in clinical applications, where the attenuation coefficient distribution is not known a priori, and for areas of inhomogeneous attenuation such as the chest. Measured attenuation correction overcomes this problem and uses different approaches to determine this map, including transmission scanning, segmented magnetic resonance images, or appropriately scaled CT scans acquired either independently on separate or simultaneously on multimodality imaging systems. Combination of data acquired from different imagers suffers from the usual problems of working with multimodality imagesnamely, accurate coregistration from the different modalities and assignment of attenuation coefficients. A current trend in ECT is to use transmission scanning to reconstruct the attenuation map. Combined ECT/CT imaging is an interesting approach; however, it considerably complicates both the scanner design and the data acquisition and processing protocols. Moreover, the cost of such systems may be prohibitive for small nuclear medicine departments. A dramatic simplification could be made if the attenuation map could be obtained directly from the emission projections, without the use of a transmission scan. This is being investigated either using a statistical model of emission data or applying the consistency conditions that allow one to identify the operator of the problem and, thus, to reconstruct the attenuation map. This article presents the physical and methodologic basis of attenuation correction and summarizes recent developments in algorithms used to compute the attenuation map in ECT. Other potential applications are also discussed.
Key Words: SPECT PET attenuation map attenuation correction
This article has been cited by other articles:
![]() |
R. Accorsi Brain Single-Photon Emission CT Physics Principles AJNR Am. J. Neuroradiol., August 1, 2008; 29(7): 1247 - 1256. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Patton and T. G. Turkington SPECT/CT Physical Principles and Attenuation Correction J. Nucl. Med. Technol., March 1, 2008; 36(1): 1 - 10. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. A.H. Cook, G. Carnes, T.-Y. Lee, and R. G. Wells Respiration-Averaged CT for Attenuation Correction in Canine Cardiac PET/CT J. Nucl. Med., May 1, 2007; 48(5): 811 - 818. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. T. Madsen Recent Advances in SPECT Imaging J. Nucl. Med., April 1, 2007; 48(4): 661 - 673. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Fricke, H. Fricke, R. Weise, A. Kammeier, R. Hagedorn, N. Lotz, O. Lindner, D. Tschoepe, and W. Burchert Attenuation Correction of Myocardial SPECT Perfusion Images with Low-Dose CT: Evaluation of the Method by Comparison with Perfusion PET J. Nucl. Med., May 1, 2005; 46(5): 736 - 744. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Fricke, E. Fricke, R. Weise, A. Kammeier, O. Lindner, and W. Burchert A Method to Remove Artifacts in Attenuation-Corrected Myocardial Perfusion SPECT Introduced by Misalignment Between Emission Scan and CT-Derived Attenuation Maps J. Nucl. Med., October 1, 2004; 45(10): 1619 - 1625. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | RSS | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |