JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zaidi, H.
Right arrow Articles by Hasegawa, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zaidi, H.
Right arrow Articles by Hasegawa, B.
Journal of Nuclear Medicine Vol. 44 No. 2 291-315
© 2003 by Society of Nuclear Medicine


Special Contributions

Determination of the Attenuation Map in Emission Tomography

Habib Zaidi, PhD1 and Bruce Hasegawa, PhD2

1 Division of Nuclear Medicine, Geneva University Hospital, Geneva, Switzerland
2 Department of Radiology, University of California, San Francisco, San Francisco, California

Reliable attenuation correction methods for quantitative emission CT (ECT) require accurate delineation of the body contour and often necessitate knowledge of internal anatomic structure. Two broad classes of methods have been used to calculate the attenuation map: transmissionless and transmission-based attenuation correction techniques. Whereas calculated attenuation correction belonging to the first class of methods is appropriate for brain studies, more adequate methods must be performed in clinical applications, where the attenuation coefficient distribution is not known a priori, and for areas of inhomogeneous attenuation such as the chest. Measured attenuation correction overcomes this problem and uses different approaches to determine this map, including transmission scanning, segmented magnetic resonance images, or appropriately scaled CT scans acquired either independently on separate or simultaneously on multimodality imaging systems. Combination of data acquired from different imagers suffers from the usual problems of working with multimodality images—namely, accurate coregistration from the different modalities and assignment of attenuation coefficients. A current trend in ECT is to use transmission scanning to reconstruct the attenuation map. Combined ECT/CT imaging is an interesting approach; however, it considerably complicates both the scanner design and the data acquisition and processing protocols. Moreover, the cost of such systems may be prohibitive for small nuclear medicine departments. A dramatic simplification could be made if the attenuation map could be obtained directly from the emission projections, without the use of a transmission scan. This is being investigated either using a statistical model of emission data or applying the consistency conditions that allow one to identify the operator of the problem and, thus, to reconstruct the attenuation map. This article presents the physical and methodologic basis of attenuation correction and summarizes recent developments in algorithms used to compute the attenuation map in ECT. Other potential applications are also discussed.

Key Words: SPECT • PET • attenuation map • attenuation correction




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
R. Accorsi
Brain Single-Photon Emission CT Physics Principles
AJNR Am. J. Neuroradiol., August 1, 2008; 29(7): 1247 - 1256.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
J. A. Patton and T. G. Turkington
SPECT/CT Physical Principles and Attenuation Correction
J. Nucl. Med. Technol., March 1, 2008; 36(1): 1 - 10.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
R. A.H. Cook, G. Carnes, T.-Y. Lee, and R. G. Wells
Respiration-Averaged CT for Attenuation Correction in Canine Cardiac PET/CT
J. Nucl. Med., May 1, 2007; 48(5): 811 - 818.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. T. Madsen
Recent Advances in SPECT Imaging
J. Nucl. Med., April 1, 2007; 48(4): 661 - 673.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
E. Fricke, H. Fricke, R. Weise, A. Kammeier, R. Hagedorn, N. Lotz, O. Lindner, D. Tschoepe, and W. Burchert
Attenuation Correction of Myocardial SPECT Perfusion Images with Low-Dose CT: Evaluation of the Method by Comparison with Perfusion PET
J. Nucl. Med., May 1, 2005; 46(5): 736 - 744.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
H. Fricke, E. Fricke, R. Weise, A. Kammeier, O. Lindner, and W. Burchert
A Method to Remove Artifacts in Attenuation-Corrected Myocardial Perfusion SPECT Introduced by Misalignment Between Emission Scan and CT-Derived Attenuation Maps
J. Nucl. Med., October 1, 2004; 45(10): 1619 - 1625.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2003 by the Society of Nuclear Medicine.