JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Osman, M. M.
Right arrow Articles by Wahl, R. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Osman, M. M.
Right arrow Articles by Wahl, R. L.
Journal of Nuclear Medicine Vol. 44 No. 2 240-243
© 2003 by Society of Nuclear Medicine


Brief Communications

Clinically Significant Inaccurate Localization of Lesions with PET/CT: Frequency in 300 Patients

Medhat M. Osman, MD, PhD1, Christian Cohade, MD2, Yuji Nakamoto, MD, PhD2, Laura T. Marshall, BS2, Jeff P. Leal, BA2 and Richard L. Wahl, MD2

1 Division of Nuclear Medicine, Department of Internal Medicine, School of Medicine, St. Louis University, St. Louis, Missouri
2 Division of Nuclear Medicine, Department of Radiology, School of Medicine, The Johns Hopkins University, Baltimore, Maryland

ABSTRACT

This study evaluated lesion mislocalization between PET and CT on PET/CT studies when CT instead of germanium is used for attenuation correction (AC). Methods: PET/CT scans were obtained for 300 clinical patients. Both CT and germanium scans were used to correct PET emission data. Cases were noted of suspected inaccurate localization of lesions on any of the 5 sets of images (PET using germanium AC [GeAC] fused and not fused with CT, PET using CT AC fused and not fused with CT, and PET with no AC [NAC]). Independent CT or MRI was used to determine true lesion locations. Results: Six of 300 patients (2%) had lesion mislocalization when CT was used for AC or fusion. True liver dome lesions were mislocalized to the right lung base on PET/CT, likely because of a respiratory motion difference between PET and CT. No mislocalization was present on NAC PET or non-CT-fused GeAC PET images. Conclusion: Serious lesion mislocalization on PET/CT studies may occur, albeit very infrequently, when CT is used for either AC or fusion.

Key Words: PET/CT • image fusion • artifact • respiratory motion




This article has been cited by other articles:


Home page
JNMHome page
D. W. Townsend
Dual-Modality Imaging: Combining Anatomy and Function
J. Nucl. Med., June 1, 2008; 49(6): 938 - 955.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
B. J. Pichler, H. F. Wehrl, and M. S. Judenhofer
Latest Advances in Molecular Imaging Instrumentation
J. Nucl. Med., June 1, 2008; 49(Suppl_2): 5S - 23S.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Suga, Y. Kawakami, H. Iwanaga, O. Tokuda, and N. Matsunaga
Automated Breath-Hold Perfusion SPECT/CT Fusion Images of the Lungs
Am. J. Roentgenol., August 1, 2007; 189(2): 455 - 463.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
W. V. Vogel, J. A. van Dalen, B. Wiering, H. Huisman, F. H.M. Corstens, T. J.M. Ruers, and W. J.G. Oyen
Evaluation of Image Registration in PET/CT of the Liver and Recommendations for Optimized Imaging
J. Nucl. Med., June 1, 2007; 48(6): 910 - 919.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
G. S.P. Meirelles, Y. E. Erdi, S. A. Nehmeh, O. D. Squire, S. M. Larson, J. L. Humm, and H. Schoder
Deep-Inspiration Breath-Hold PET/CT: Clinical Findings with a New Technique for Detection and Characterization of Thoracic Lesions
J. Nucl. Med., May 1, 2007; 48(5): 712 - 719.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. Martinez-Moller, M. Souvatzoglou, N. Navab, M. Schwaiger, and S. G. Nekolla
Artifacts from Misaligned CT in Cardiac Perfusion PET/CT Studies: Frequency, Effects, and Potential Solutions
J. Nucl. Med., February 1, 2007; 48(2): 188 - 193.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. M. Blodgett, C. C. Meltzer, and D. W. Townsend
PET/CT: Form and Function
Radiology, February 1, 2007; 242(2): 360 - 385.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. Brechtel and T. Beyer
Reply: Adequate Evaluation of Image Registration in Hybrid PET/CT.
J. Nucl. Med., September 1, 2006; 47(9): 1557 - 1558.
[Full Text] [PDF]


Home page
RadioGraphicsHome page
M. A. Blake, A. Singh, B. N. Setty, J. Slattery, M. Kalra, M. M. Maher, D. V. Sahani, A. J. Fischman, and P. R. Mueller
Pearls and Pitfalls in Interpretation of Abdominal and Pelvic PET-CT
RadioGraphics, September 1, 2006; 26(5): 1335 - 1353.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
D. Delbeke, R. E. Coleman, M. J. Guiberteau, M. L. Brown, H. D. Royal, B. A. Siegel, D. W. Townsend, L. L. Berland, J. A. Parker, G. Zubal, et al.
Procedure Guideline for SPECT/CT Imaging 1.0
J. Nucl. Med., July 1, 2006; 47(7): 1227 - 1234.
[Full Text] [PDF]


Home page
JNMHome page
D. Delbeke, R. E. Coleman, M. J. Guiberteau, M. L. Brown, H. D. Royal, B. A. Siegel, D. W. Townsend, L. L. Berland, J. A. Parker, K. Hubner, et al.
Procedure Guideline for Tumor Imaging with 18F-FDG PET/CT 1.0
J. Nucl. Med., May 1, 2006; 47(5): 885 - 895.
[Full Text] [PDF]


Home page
JNMHome page
T. Pan, O. Mawlawi, S. A. Nehmeh, Y. E. Erdi, D. Luo, H. H. Liu, R. Castillo, R. Mohan, Z. Liao, and H.A. Macapinlac
Attenuation Correction of PET Images with Respiration-Averaged CT Images in PET/CT
J. Nucl. Med., September 1, 2005; 46(9): 1481 - 1487.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
R. E. Coleman, D. Delbeke, M. J. Guiberteau, P. S. Conti, H. D. Royal, J. C. Weinreb, B. A. Siegel, M. F. Federle, D. W. Townsend, and L. L. Berland
Concurrent PET/CT with an Integrated Imaging System: Intersociety Dialogue from the Joint Working Group of the American College of Radiology, the Society of Nuclear Medicine, and the Society of Computed Body Tomography and Magnetic Resonance
J. Nucl. Med., July 1, 2005; 46(7): 1225 - 1239.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. F. Branstetter IV, T. M. Blodgett, L. A. Zimmer, C. H. Snyderman, J. T. Johnson, S. Raman, and C. C. Meltzer
Head and Neck Malignancy: Is PET/CT More Accurate than PET or CT Alone?
Radiology, May 1, 2005; 235(2): 580 - 586.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. M. Blodgett, B. Casagranda, D. W. Townsend, and C. C. Meltzer
Issues, Controversies, and Clinical Utility of Combined PET/CT Imaging: What Is the Interpreting Physician Facing?
Am. J. Roentgenol., May 1, 2005; 184(5_supp): S138 - S145.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
L. Boucher, S. Rodrigue, R. Lecomte, and F. Benard
Respiratory Gating for 3-Dimensional PET of the Thorax: Feasibility and Initial Results
J. Nucl. Med., February 1, 2004; 45(2): 214 - 219.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
C. T. Thomas, P. T. Bradshaw, B. H. Pollock, J. E. Montie, J. M.G. Taylor, H. D. Thames, P. W. McLaughlin, D. A. DeBiose, D. H. Hussey, and R. L. Wahl
In Reply:
J. Clin. Oncol., January 15, 2004; 22(2): 380 - 381.
[Full Text] [PDF]


Home page
JNMHome page
R. S. Hattner
Ahem, Blame the Daughter!
J. Nucl. Med., January 1, 2004; 45(1): 153 - 153.
[Full Text] [PDF]


Home page
JNMHome page
D. W. Townsend, J. P.J. Carney, J. T. Yap, and N. C. Hall
PET/CT Today and Tomorrow
J. Nucl. Med., January 1, 2004; 45(90010): 4S - 14.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
W. V. Vogel, W. J.G. Oyen, J. O. Barentsz, J. H.A.M. Kaanders, and F. H.M. Corstens
PET/CT: Panacea, Redundancy, or Something in Between?
J. Nucl. Med., January 1, 2004; 45(90010): 15S - 24.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
R. L. Wahl
Why Nearly All PET of Abdominal and Pelvic Cancers Will Be Performed as PET/CT
J. Nucl. Med., January 1, 2004; 45(90010): 82S - 95.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
G. Antoch, F. M. Vogt, L. S. Freudenberg, F. Nazaradeh, S. C. Goehde, J. Barkhausen, G. Dahmen, A. Bockisch, J. F. Debatin, and S. G. Ruehm
Whole-Body Dual-Modality PET/CT and Whole-Body MRI for Tumor Staging in Oncology
JAMA, December 24, 2003; 290(24): 3199 - 3206.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2003 by the Society of Nuclear Medicine.